Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC A T ROAD HAIBORGAON HOUSE NO NIL CITY NAGAON P O HAIBORGAON P S NAGAON SADAR DISTRICT NAGAON PIN 782001 | NAGAON | ASSAM | 782001 | ₹1.0 Cr | L1 | Accepted-AOC work is awarded to L1 bidder |
| 2 | L2₹1.0 Cr+₹15,129.64 (0.15%)Rejected-Finance HAIBORGAON CITY TOWN NAGAON P O HAIBORGAON P S NAGAON PIN 782002 DISTRICT NAGAON ASSAM | NAGAON | ASSAM | 782002 | ₹1.0 Cr+₹15,129.64 (0.15%) | L2 | Rejected-Finance work is allotted to L1 bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| Sl No | Description | Qty | Unit | Rishabh Jain L2 | PARDEEP KUMAR JAIN L1 |
|---|---|---|---|---|---|
| 1.00Construction of RCC Covered Drain cum footpath | |||||
| 2.00 | Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out,
construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material | 1,162.06 | CUM | 150 ₹1,74,308.55 | 134.47 ₹1,56,261.8 Lowest |
| 3.00 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803,1202 & 1203
P.C.C Grade M 10
Nominal mix 1:3:6 | 63.1 | CUM | 6,000 ₹3,78,600 | 5,905.4 ₹3,72,630.74 Lowest |
| 4.00 | Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications.
Base Slab & Vertical Wall
12 mm dia main bar @ 125mm c/c
8 mm dia binder @ 150mm c/c | 22.18 | MT | 68,000 ₹15,08,240 | 67,687 ₹15,01,297.66 Lowest |
| 5.00 | Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in Super-structure complete as per drawing and technical specifications.
Slab
12mm dia main bar bottom & Top Jali 150mm c/c
10mm dia binder 150mm c/c | 14.96 | MT | 74,382 ₹11,12,754.72 Lowest | 74,382 ₹11,12,754.72 Lowest |
| 6.00 | Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. Without plasticiser. RCC Grade M25
Base Slab
Wall | 322.65 | CUM | 8,360.9 ₹26,97,644.39 Lowest | 8,360.9 ₹26,97,644.39 Lowest |
| 7.00 | Plain/Reinforced cement concrete, in super structure complete as per drawing and technical specification and steel shuttering formwork. Without plasticiser. RCC Grade M30
Top Slab | 107.55 | CUM | 9,190.4 ₹9,88,427.52 Lowest | 9,190.4 ₹9,88,427.52 Lowest |
| 8.00 | Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending
through the full width of the structure with slope of 1V :20H towards drawing face including fixing of Grating Plate Complete as per drawing and Technical specification. | 478 | EACH | 216.58 ₹1,03,525.24 Lowest | 216.58 ₹1,03,525.24 Lowest |
| 9.00 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 | 316.68 | CUM | 1,919.5 ₹6,07,867.26 Lowest | 1,919.5 ₹6,07,867.26 Lowest |
| 10.00Construction of RCC Covered Connecting Drain (Cross Drain) | |||||
Tender Value
₹1.0 Cr
EMD Value
₹2.1 L
Closing Date
20 Jan 2026, 2:00 pmClosed
Executive Officer
Nagaoan Municipal Board, Nagaon
Construction of RCC Covered Drain cum footpath from Ch.0.00 m to Ch.500.00 m including re-construction of RCC Box Culvert No.1/1 and 1/2 on Bidya Baruah Road and construction of New RCC Box Culvert on MG road
2025_UDD_49736_1
NMB.VII38APARTII/2025-26/302
Open Tender
Civil Works
Item Rate
180 days
Nagaon
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,079
Yes
₹2.1 L
Yes
21 Feb 2026
30 Dec 2025
20 Jan 2026
30 Dec 2025
20 Jan 2026
30 Dec 2025
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803,1202 & 1203 P.C.C Grade M 10 Nominal mix 1:3:6
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications. Base Slab & Vertical Wall 12 mm dia main bar @ 125mm c/c 8 mm dia binder @ 150mm c/c
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in Super-structure complete as per drawing and technical specifications. Slab 12mm dia main bar bottom & Top Jali 150mm c/c 10mm dia binder 150mm c/c
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. Without plasticiser. RCC Grade M25 Base Slab Wall
Plain/Reinforced cement concrete, in super structure complete as per drawing and technical specification and steel shuttering formwork. Without plasticiser. RCC Grade M30 Top Slab
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face including fixing of Grating Plate Complete as per drawing and Technical specification.
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803,1202 & 1203 P.C.C Grade M 10 Nominal mix 1:3:6
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications Base Slab & Vertical Wall 12 mm dia @ 125mm c/c (Outer) 12 mm dia @ 125mm c/c (Inner) 10 mm dia binder @ 150mm c/c
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in Super-structure complete as per drawing and technical specifications Slab 16mm dia main bar bottom Jali 150mm c/c 12mm dia main bar Top Jali 150mm c/c 10mm dia binder 150mm c/c
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. Without plasticiser. RCC Grade M25 Base Slab Wall
Plain/Reinforced cement concrete, in super structure complete as per drawing and technical specification and steel shuttering formwork. Without plasticiser. RCC Grade M30 Top Slab
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803,1202 & 1203 P.C.C Grade M 10 Nominal mix 1:3:6
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications Base Slab & Vertical Wall 16 mm dia @ 125mm c/c (Outer) 16 mm dia @ 125mm c/c (Inner) 10 mm dia binder @ 150mm c/c Slab 16mm dia main bar bottom Jali 125mm c/c 16mm dia main bar Top Jali 125mm c/c 10mm dia binder 150mm c/c
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. Without plasticiser. RCC Grade M25 Base Slab Wall
Plain/Reinforced cement concrete, in super structure complete as per drawing and technical specification and steel shuttering formwork. Without plasticiser. RCC Grade M30 Top Slab
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
Dismantling of existing structure like culverts, bridges, retaining walls and other structures comprising of masonary, cement concrete, wood work, steel work including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lead and lift up to 1000m. B) Brick masonary structures in cement mortar
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary Soil A.Manual Means (Without dewatering) (I) Up to 3.0m depth
Providing concrete for Plain/reinforced concrete in open foundations complete as per drawing and Technical specifications Clause 802, 803, 1202 & 1203 (A) with Crushed Stone, (I) . Ordinary Soil A.Manual Means (Without dewatering) (I) Up to 3.0m depth
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork(I) RCC Grade M25, Nominal Mix. Raft RCC Kerb Box Walls Slab Haunches End Pillars
Supplying, fitting and placing HYSD bar reinforcement in Superstructure complete as per drawing and technical specifications clauses 1002,1010 and 1202
Providing & laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 A. With crushed stone Slab (Wearing Coat)
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary Soil A.Manual Means (Without dewatering) (I) Up to 3.0m depth
Providing concrete for Plain/reinforced concrete in open foundations complete as per drawing and Technical specifications Clause 802, 803, 1202 & 1203 (A) with Crushed Stone, (I) . Ordinary Soil A.Manual Means (Without dewatering) (I) Up to 3.0m depth
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork(I) RCC Grade M25, Nominal Mix. Raft RCC Kerb Box Walls Slab Haunches End Pillars
Supplying, fitting and placing HYSD bar reinforcement in Superstructure complete as per drawing and technical specifications clauses 1002,1010 and 1202
Providing & laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 A. With crushed stone Slab (Wearing Coat)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.93 MB
SBD.pdf
Tender Documents • 9.02 MB
FOB2.pdf
Tender Documents • 0.70 MB
BOQ_79084.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .