| Sl No | Description | Qty | Unit | Ganpati Infrapower Private Limited. L2 | SMARU TECH LLP L1 |
|---|---|---|---|---|---|
| 1.00Spare Parts for Capacitor Bank 1.98 MVAR/3.96 MVAR | |||||
| 1.01 | Capacitor Cell 132 KVAR 7.3 KV | 60 | NOS | 55,724.44 ₹39,45,290.37 | 51,177 ₹36,23,331.6 Lowest |
| 1.02 | Capacitor Cell 264 KVAR 7.3 KV | 60 | NOS | 76,410.55 ₹54,09,866.94 | 70,175 ₹49,68,390 Lowest |
| 1.03 | Capacitor Cell 396 KVAR 7.3 KV | 30 | NOS | 1,06,708 ₹37,77,463.2 | 99,138.2 ₹35,09,492.28 Lowest |
| 1.04 | Reactor 0.25 KVAR | 10 | Nos | 29,320.31 ₹3,45,979.66 | 26,927.6 ₹3,17,745.68 Lowest |
| 1.05 | Reactor 0.5 KVAR | 10 | Nos | 33,536.8 ₹3,95,734.24 | 28,795.2 ₹3,39,783.36 Lowest |
| 1.06 | Reactor 0.8 KVAR | 10 | Nos | 34,932.45 ₹4,12,202.91 | 31,654 ₹3,73,517.2 Lowest |
| 1.07 | Surge Capacitor | 12 | NOS | 52,876.08 ₹7,48,725.29 | 47,913.6 ₹6,78,456.58 Lowest |
| 1.08 | Vaccum Contactor (for CRCA Panel), 12 KV 400 Amp. | 36 | NOS | 1,91,580 ₹81,38,318.4 | 1,75,000 ₹74,34,000 Lowest |
| 1.09 | 9 KV, 10 KA class II Lightning Arrestor | 120 | NOS | 10,042.5 ₹14,22,018 | 9,100 ₹12,88,560 Lowest |
Tender Value
Refer Docs
EMD Value
₹11.4 L
Closing Date
2 Jun 2025, 5:00 pmClosed
SE (MM-II)
PuVVNL VARANASI
Maintenance work of capacitor bank installed at power substations under PuVVNL Varanasi for 03 Years (On Turnkey Basis)
2025_PVVNV_1041708_1
EAV-03/2025-26
Open Tender
Electrical Works
Lump-sum
1095 days
Varanasi
as per td
3 documents required · 3 mandatory
₹11,800
Yes
Administrative Officer for Managing Director
₹11.4 L
Yes
9 Jul 2025
22 May 2025
3 Jun 2025
22 May 2025
2 Jun 2025
22 May 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Spare Parts for Capacitor Bank 1.98 MVAR/3.96 MVAR | |||||
| 1.01 | Capacitor Cell 132 KVAR 7.3 KV | 60 | NOS | - | - |
| 1.02 | Capacitor Cell 264 KVAR 7.3 KV | 60 | NOS | - | - |
| 1.03 | Capacitor Cell 396 KVAR 7.3 KV | 30 | NOS | - | - |
| 1.04 | Reactor 0.25 KVAR | 10 | Nos | - | - |
| 1.05 | Reactor 0.5 KVAR | 10 | Nos | - | - |
| 1.06 | Reactor 0.8 KVAR | 10 | Nos | - | - |
| 1.07 | Surge Capacitor | 12 | NOS | - | - |
| 1.08 | Vaccum Contactor (for CRCA Panel), 12 KV 400 Amp. | 36 | NOS | - | - |
| 1.09 | 9 KV, 10 KA class II Lightning Arrestor | 120 | NOS | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tenderdocument.rar
Tender Documents • 1.16 MB
BOQ.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .