Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC VILLAGE POST PATHOLI AGRA UTTAR PRADESH INDIA | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.6 L+₹4.2 L (22.8%)Rejected-Finance 40 6 UKHARA PO PRATAP PURA AGRA UP 282001 | AGRA | AGRA | UP | 282001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹23.3 L+₹4.9 L (26.5%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹24.0 L+₹5.6 L (30.1%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹24.7 L+₹6.3 L (34.1%)Rejected-Finance 208 L MODEL TOWN LUDHIANA | LUDHIANA | LUDHIANA | PUNJAB | L5 | Rejected-Finance Other than L1 |
Tender Value
₹30.3 L
EMD Value
₹60,620
Closing Date
10 Dec 2021, 6:00 pmClosed
GE EAST AGRA
GE East Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt 282001
SPECIAL REPAIR TO MT SHED BLDG NO T 35, T 38 AND TWO WASHING RAMPS OF 7 PARA UNDER GE EAST AGRA
2021_MES_485213_1
9394/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE EAST AGRA
₹60,620
Yes
28 Dec 2021
30 Oct 2021
14 Dec 2021
30 Oct 2021
10 Dec 2021
13 Nov 2021
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
M& L for PCC 1:2:4 -1 type B2 (using 40mm graded crushed stone aggregate) as in floor, path, (100 mm thick ) finished even and fair complete all as specified and directed.
M& L 20 mm thick Wearproof topping as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner) complete all as specified and directed. Note: Mettalic hardner will be measured and paid seperately under respective items of sch 'A')
Supply only mettallic floor hardner for floor finishes and paving (as approved by GE nito bond EP base resin FOROC) complete all as specified and directed.
Demolition of brick work or stone/ boulder Masonry, built in cement mortar including all quoins, pillars etc.complete all as specified and directed.
M&L Brick work with sub-class `B' bricks old size, straight or curved on plan exceeding 6 Mtr mean radius built in cement mortar 1:6 complete all as specified and as directed.
Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on brick or concrete surface with water proofing compound @ 3% by weight of cement finished fair complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately under respective item of Sch ‘A’.
M&L for 15 mm thick rendering in CM 1:6 on other than fair faces of brick or concrete surface with finished fair and even complete all as specified and directed.
Supply only integral water proofing compound liquid complete all as specified and directed.
M&L for preparation of New plastered surfaces of wall and applying three coat of white wash complete all as specified and directed.
M&L for Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying One coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparation of New steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ complete all as specified and directed.
M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint over one coat of cement primer (self primer) complete all as specified and directed.
M&L for complete removal of existing treatment from walls and applying two coats of oil bound distemper over a coat of Chalk whitening complete all as specified and directed
M&L for complete removal of existing treatment from walls and and applying two coats of cement base paint over a coat of cement primer (self primer) complete all as specified and directed.
M&L for preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whitening complete all as specified and directed.
S&F in repair Steel rolling shutters, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position including dismantling existing shutter as indicated, complete: push pull or Ditto, but gear operated type with bevel gear box and crank handle Extra for including a 4 lever mild steel safety lock, lockable from both inside and outside (areaof wicket door to be only measured) complete all as specified and directed.
Taking up or down 40 to 50mm bore steel tubing and connection complete all as specified and directed.
S&F 40 mm steel water tubing, medium grade, galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
M&L Providing, cement concrete 1:2:4 type B1, using 20mm graded stone aggregate in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly for ramp, rounded for chamfered angles and throating, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete and all as specified and directed.
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FR PVC insulated unsheathed cable with proper colour coding drawn in including PVC concealed conduit not less than 20 mm dia with all accessories and FR PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, including cutting and chasing of wall surface for laying PVC conduit and modular sunken box and connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Make Polycab/Havells/RR Kablel/Grandlay. Note :Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following :- (a) One light point or one fan point controlled by one switch
One 3 pin socket outlet 5 amps on the same board with other switches
One 5 pin socket outlet 5/6 Amps on independent board
All as per item No 24 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FR PVC insulated sheathed cable with FR PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board
Supply and fix switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body all as specified and directed. Make : Havells/Cona/Plaza/Legrand
Supply and fix Switch piano flush button single pole one way 15 amps 230 Volts with polycarbonate body all as specified and directed. Make : Havells/Cona/Plaza/Legrand
Supply and fix socket 5 amps 5 pin flush type, 240 volts. with polycarbonate body. Make : Havells/Cona/Plaza/Legrand
Supply and fix socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body all as specified and directed. Make : Havells/Cona/Plaza/Legrand
Supply and fix stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd, complete all as specified and directed. Make : Havells/Cona/Plaza/Legrand
Supply and fix ceiling rose , PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals all as specified and directed. Make : Havells/Cona/Plaza/Legrand
Supplying and fixing in repair 20 watt LED battan surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly pre-wired upto terminal block, power consumption < 20W, luminaire lumens > 2000 lms, driver efficiency > 85%, power facor > 0.95 THD < 20% as per IEC 61000-3-2, colour temp - 6500 K Surge protection 2.5 KV, 50000 burning hrs (min) as per L 70 criteria, two stages isolated constant current operated driver with range 150 - 270 VAC and safety extra low voltage safe level < 60 VDC as per IEC standard with LM 70 & 80 certification and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.75 Sqmm and fixing arrangements for fixing the light fitting, complete all as specified and directed. Make :- Wipro Model No D532065 or equivalent model/ make of Wipro/CG
Supply and fix Lamp holder/angle holder insulated body with black/white plate for batten fittings complete all as specified and directed. Make : Havells/Cona/Plaza/Legrand
Supply and fix of LED Bulb 7 W, warm white all as specified and directed. Make : Wipro/Philips/CG
Supply & fixing in repair LED security light compact & trendy of 35 watt with aluminium pressure diecast housing, IP 65 protection, luminaire lumens > 3000 lumens/W and in built electronic driver prewire upto terminal block with driver efficiency > 85 %, power factor > 0.95, as per IEC 61000-3-2, colour temp 6500 K Surge protection 3.5 KV, 50000 burning hrs (min) as per L70 Criteria, multi stage constant current operated driver with range 150-270 VAC and safety exra low voltage safe load < 60 VDC as per IEC standards with LM 70 & 80 certification complete all as specified, fixed to pole or wall of buiding with and including suitable Bracket made out of 40 mm dia GI light grade pipe, 1.20 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 50x6 mm to be tightened with suitabe size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 Sqmm including all accessories and fixing arrangements for fixing the light fitting complete all as specified & directed. Make : Wipro Model No D933065of Wipro or equivalent model/ make of Wipro/Bajaj
Supply & fix in repair sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 4 way with IP-43 protection double door complete with appropriate size bus bar and neutral link all as specified and directed. Make : Legrand/Schneider/Havells/Hager
Supply & fix in repair sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-43 protection double door complete with appropriate size bus bar and neutral link all as specified and directed. Make : Legrand/Schneider/Havells/Hager
Supply and fixing in repair MCB SP 5 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning. Make : Legrand/Schneider/Havells/Hager
Supply and fixing in repair MCB SPN 40 to 63 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning. Make : Legrand/Schneider/Havells/Hager
S&F sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x1.5sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 1x1.5 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in PVCl Conduit not less than 20 mm dia including dismantling of old unsv submain wiring complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete.Make Polycab/Havells/RR Kablel/Grandlay
S&F sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x4sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 1x2.5 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in PVCl Conduit not less than 20 mm dia including dismantling of old unsv submain wiring complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete.Make Polycab/Havells/RR Kablel/Grandlay
Materials and labour as in replacement for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Supply and lay in repair/replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 Core, including dismantling of Old Unsv cable Complete all as specified and directed. Make : Havells/Polycab/Grandlay
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks old size locally available best quality laid dry in trenches for protection of underground cable all as specified and directed.
Supply and lay in replacement GI tube light grade 40 size as in cable protection pipe including all fittings complete all as specified and directed. Make Jindal/Prakash/Surya/Bansal
Attar Singh and Sons
Sree Ram Enterprises
Asha Construction
M/s S. K. Construction Co.
SHRI RADHAYSHYAM JHA
Allied Builders
M/S RISHI RAJ AGRAWAL
MNR ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .