SE EM Circle PWD Kanpur
SE EM Circle PWD Kanpur
Janpad Nayalaya Kanpur Nagar me Fire Alarm Awam Fire Fighting System Repairing Tatha Fire Extinguisher ki Re-filling ka Karay.
2026_CEEMP_1113201_1
98C/4C-EMC/2025-26 dated 21.01.2026
Open Tender
Electrical Works
60 days
Kanpur Nagar
3 documents required · 3 mandatory
₹766
EE EM Division PWD Kanpur
₹93,000
EE EM Division PWD Kanpur
23 Feb 2026
6 Feb 2026
17 Feb 2026
6 Feb 2026
17 Feb 2026
6 Feb 2026
10 Feb 2026
Repairing/Servicing of landing/hydrant valve 63 mm dia. outlet with the replacement of Female Adopter, Plunger, rubber, Washer, rubber gasket, nut bolt etc. Complete as required.
Repairing/Servicing of hose reel drum with changing of 30 mtr. long rubber pipe and shut off nozzle 25mm dia.
Cleaning and repairing of pump room & underground water tank with water proffing of UG Tank.
Painting of all existing pipe lines, boxes, pump house equipment with the two coat ISI Red Paint and primer etc.
Repairing/Servicing of of 10 Zone Fire Alarm main control panel Microprocessor based with Public Address System. complete in all respect.
Repairing/Servicing of of 6 Zone Local Fire alarm control panel. Complete labour and T&P.
Repairing/Servicing of for Manual Call point Break Glass type housed in MS sheet, including connection.
Repairing/Servicing of Electronic LMT Hooter, housed in MS housing suitable for wall mounting/ceiling, including making connection.
Repairing/Servicing of Responsce indicator pul stanting type suitable for including connection. Complete in all respect.
Repairing/Servicing of Smoke Detector as per specifaction including making connections with wire.
Repairing/Servicing of Heat Detector ROR Type as per specification including making connection with wire.
Refilling of ABC Type 4 Kg Capacity Fire Extinguisher. All complete as per direction of E/ic.
Refilling of Co2 Type 4.5 Kg Capacity Fire Extinguisher. All complete as per direction of Engineer in Charge.
SITC of shut off nozzle complete in all respect.
SITC of RRL Hose PIPE 63 mm dia x 15 m long complete with GM/SS coupling conforming to IS: 636.
SITC of SS Branch Pipe & Nozzle IS: 903.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
SITC of lionization Smoke Detector as per specifaction.
SITC of Heat Detector ROR Type as per specification
Providing and fixing in position the industrial type pressure gauge complete as required
Total
Note :- G.S.T. @ 18% Extra
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.18 MB
BOQ_2060010.xls
BOQ • 0.32 MB
T1.pdf
Tender Documents • 1.35 MB
Download all tender documents and submit your bid