Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 829 A OPPSITE DOGRA GROWND GANDHI NAGAR JAMMU JAMMU KASHMIR JAMMU JAMMU AND KASHMIR 180004 | JAMMU | JAMMU AND KASHMIR | 180004 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance FLAT 987 GROUND FLOOR POCKET 3 SECTOR 19 DWARKA DWARKA SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹88.6 L
Closing Date
27 Sept 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2021_PWDJK_139603_1
e-NIT No.EDJ/104 of 2021-22 Dated 15-09-2021
Open Tender
Electrical Works
Item Rate
Billawar District Kathua
please refer to NIT
3 documents required · 3 mandatory
₹0
Exempted
4 Oct 2021
15 Sept 2021
28 Sept 2021
16 Sept 2021
27 Sept 2021
16 Sept 2021
120 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group B)
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 10 sq.mm +2 X 6 sq.mm earth wire
4 x 16 sq.mm +2 X 6 sq.mm earth wire
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Telephone socket outlet
TV antenna socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 pair
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Supplying and fixing of suitable size GI box with modular plate and cover including, providing and fixing of 2 Nos. 5/6 amp switch and socket.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing of following rating 240/415 Volt's "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning. (Above 32 Amp.).
TPN 40 Amp.
TPN 63 Amp
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB /Isolator)
8 way (4 + 24), Double door
Supplying and fixing of 20/22 watt LED 4 feet tube light fitting/fixture Aluminium housing.
Supplying & fixing Recess/surface mounted LED Luminarie with full diffuser (size 600mm x 600 mm).
Supplying and fixing of 20W 1600 Lumens Surface mounted LED fixture (Down Lighter) (circular/square)
Supply of Wall / Ceiling Fans 230V 50Hz celing fan with double ball bearing with low power consumption of following sweeps:
1200mm Ceiling Fan with rod upto 2'-0'
Supply of following sizes of heavy duty exhaust fan
300mm Sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
6 way , Double door
Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.
Providing and fixing of 25mm x 3 mm copper strip on surface or in rescess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover.
Providing and fixing of 25mm x 3 mm GI strip on surface or in rescess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Fabrication, supplying, installation testing and commissioning of main pannel made out of 2mm thick M.S. sheet, floor mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors duly painted, with provision for fixing of 1 no incomer FP MCCB, change over switch including providing & fixing of 300 Amp 3 Phase Aluminum bus bar 2 set and Digital Meter devices and MCB strip for housing MCB's including connection etc. as required. i. 5 x 4 x 1 x 25 = 25 CFT. (Main Panel 25 CFT.) ii. 3 x 4 x 1 x 25 = 15 Cft. (Sub Main Panel 2 Nos. 30 Cft)
Providing and fixing following rating and breaking capacity MCCB FP in existing cubical panel board including drilling of holes in cubical panel and making connections etc. as required.
100 A,36 KA,FPMCCB
200 A,36KA,FPMCCB
400 A, 50 KA FPMCCB
Change Over Switch 200 A Front operated.
Aluminium Bus Bar 200 Amp.
Aluminium Bus Bar 300 Amp.
Aluminium Bus Bar 400 Amp.
Aluminium Bus Bar 1000 Amp.
Supplying and fixing of 1.1 KV PVC insulated and PVC sheathed XLPE Power Cable of following sizes on surface/surface cable tray etc. as required including carriage upto site of work.
70 Sq.mm 3.5 core armored.
95 Sq.mm 3.5 core armored.
150 Sq.mm 3.5 core armored.
400 Sq.mm 3.5 core armored.
Supply, Installation of ABC type Fire extinguishers 6kg , wall mounted.
Electric Shock Treatment chart ( larger size) with aluminium frame and glass on front or laminated as approved.
Supply and laying of Fire Retardant 2.5mm Insulation Mat of Class B 11kV class manufactured as per IS 15652:2006 duly tested by CPRI. Test certificate to be provided by the manufacturer/contractor.Dimension of mat shall be 1000mmx2000mm each
Supply, Installation, Testing and commissioning of Fire Detection system consisting of the following components :
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing and commissioning of Analog Addressable type Active/ Passive Repeater Fire Alarm panel with Backlit LCD Display, having Controls For Reset, Mute, AcceptSilence alarms and Self Test Conforming to BS5839 Standards and Duly approved by EN54/LPCB
Supply, installation, testing and commissioning of 82.5 KVA capacity silent DG set comprising of stationary type, Liquid Cooled, turbocharged after cooled developing suitable BHP under NTP condition of BS:5514/ISO3046 & ISO 8528 and alternator brushless, self excited self regulated conforming to BS 5000/IS 4722 suitable for continuous operation, generating 82.5 KVA at 1500 RPM, 415 volts, 0.8 power factor 50HZ, 3 phase. The set shall have Microprocessor/relay based AMF control panel. The Engine and Alternator would be duly aligned and coupled with each other on the common MS fabricated base frame. The sound attenuating system of Silent DG Set shall conform to latest MOEF/CPCB II norms amended upto date, of noise level upto 75db at 1 meter distance. The set shall also have inbuilt fuel tank, fully filled with Diesel, and Batteries. Installation & commissioning of Silent DG Set at site, shall include handling, installation of DG Set on the Cement Concrete Platform, , and Earthing for DG set and Panel as per relevant IS specifications. The job including constructuion of Cement Concrete Platform.
Supply, Installation Testing and commisisoning of 20 kVA UPF ( 3Ph-3Ph ) redundant true online UPS with SMF batteries providing VAH =15120 ( 42AH , 30 Nos) against a time backup of 30 Minutes. UPS shall be supplied with 20KVA Galvanic Isolation transformer (3 Phase in - 3 Phase out). The 20 kVA UPS modules shall be redundant without disruption of supply from other working modules. UPS shall have inbuilt protections against short circuit, undervoltage, overvoltage, surge protection, loss of neutral.
Full HD 2 MP 1080P D&N IR Dome/Bullet Camera Make:- Bosch, Pelco, Samsung, Sony, Honeywell, AXIS
Full HD 5 MP 1080P D&N IR Dome/Bullet Camera Make:- Bosch, Pelco, Samsung, Sony, Honeywell, AXIS
Supply Installation Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. Make: Finolex/Polycab/Havells
Supply, Installation, Testing and comissioning of 8 port Layer ‑2 managable Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/Juniper/Alcatel
6 TB surveillance Hard disk storage device.
Micro SD/SDHC Card 128 GB
Supply and erection of PVC pipe 25mm dia ISI marked ( Medium ) surface duly clamped/ recessed in wall / ceiling etc. Make: Ravindra, Polypack, AKG
1 mtr. Cat 6 Networking patch cord cable.
Supply Installation Testing & Commissioning of 6U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements. Makes: Valrack/Comrack/Hcl
Supply,installation,testing and commissioning of 3.0 KVA rating online Double conversion IGBT True Online Uniterrupted power supply alongwith battery back up of 4 hours suitable for single phas 90-240 input andoutput220 volt .UPS shall have inbuilt galvanic isolation transformer,automatic and manual bypass system . UPS shall be supplied with SMF batteries,Mounting rack for batteries,internal cabling/busbar for banking of batteries between UPS to Battery bank.UPS shall have inbuilt protections againest short circuit,undervoltage,overvoltage,surge protection,loss of neutral . Makes:-Mitsubishi/Numeric/APC/emerson. Rating 3.0 KVA
Supply Installation Testing & Commissioning of 42" LED Monitor, Full HD, HDMI Port, Component Video Inputs, Digital Audio Out, Make: Sony/Samsung
Supplying ,installation testing and commissioning of 32 Channel Network Video Recorder (NVR).
Supply Installation Testing & Commissioning of STP Cat 6 UTP Cable Armoured, Transmission frequency of 250 MHz (Minimum),cable Should be 4 pair and Cable should be Fire Retardant. Make: R&M/Systimax/Seimon
Supply Installation testing and Comissioning of 10 mtr HDMI cable Make : Kramer/Key-digital/Extron
Supply Installation testing and Comissioning of AVR of rating 3KVA complete with isolation transformer.
Supply Installation testing and Comissioning of Surge Protector.
Design, manufacture and supply of indoor type of three phase 415 volt LT unbalanced 400 Kva servo controlled automatic voltage stabilizer copper wound oil cooled type designed for input voltage 260 V to 450 V phase to phase and output voltage 415 V ± 1% phase to phase and 230 volt ± 1% phase to neutral and frequency 50 HZ +/- 3%. The no load current shall not be more than 5% of the rated output current. The stabilizer shall be totally powder coated from outside to have aesthetic outlook and inside of tank should be zinc chromate painted. Panel should be screen-printed. The unit shall be housed in sheet steel of 14 gauge thickness having wheels with sturdy construction to withstand the rigorous shifting movement, repair works and handling. The unit shall be supplied with first filling of fresh filtered transformer oil having dielectric strength and shall be suitable for unbalanced input voltage and unbalanced output load complete with Comprehensive Warranty for 2 years.
SHOWKAT HUSSAIN NAJAR
M/S CHANDI MAA
S.R SALES CORPORATION
aecom engineering pvt.ltd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .