Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.5 LAccepted-AOC SENTHARAPPATTY PO GANGAVALLI TK SALEM DISTRICT | SALEM | TAMIL NADU | 621011 | 1 | Accepted-AOC Work Order | |
| 2 | 2₹7.5 L+₹418.11 (0.06%)Rejected-Finance | 2 | Rejected-Finance Rejected |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
21 Aug 2024, 3:00 pmClosed
EXECUTIVE OFFICER
9, Attur Main Road, Veeraganur Post, Gangavalli Tk, Salem Dt.
Providing Bore Well With Mini Power Pump At Ward No 6 in Veeraganur Town Panchayat Salem District.
2024_DTP_474052_1
186/2024
Open Tender
Civil Works - Water Works
Works
45 days
VEERAGANUR TOWN PANCHAYAT
IV
2 documents required · 2 mandatory
₹0
₹18,000
Yes
VEERAGANUR TOWN PANCHAYAT
30 Aug 2024
17 Aug 2024
21 Aug 2024
17 Aug 2024
21 Aug 2024
17 Aug 2024
19 Aug 2024
Amount
Geophysical Investigation charges including preparation of geophysical report as per TWAD Board type circular including all cost of transportation and handling charges etc.,complete
Drilling 150 mm Dia bore well in Hard rock areas anywhere in the state inculding transportation to site of work in hardrock areas inculding labour charges for insertion of MS casing pipe and flushing of borewell and for minutes. ( As per MD TWAD Board Chennai Letter No : F.251112/Drilling rate/A[4]/COM/2021, Dated:27/4/2022 )
Supply and delivery of 150mm OD 6KSC PVC casing pipe for bore well with best approved quality conforming to ISS including all cost and convayance of material to site and labour charges for errection of pipe to the borewell etc., complete.
Labour Charges for in inserting 150mm Dia PVC casing pipes assemble (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with cement paste etc., complete supply and packing the annular space with pebbles of size and quality as approved by the executive engineers of TWAD Board
Supplying and fixing in position of the following PVC / G.I pipes and specials best approved quality conforming to ISS and providing leak proof joint with PVC adhesive etc., complete complying with standard specification.
Submersible motor 75 LPM x 225m Head
10.00 Hp Pannel Board
4.00 sqmm 3core copper cable
50mm UPVC Pipe
40mm G.I "B" Class pipe
40mm G.I Heavy coupling
50mm Gun Metal Gate Valve
63mm PVC 6kg pipe
65mm GI Pipe
Kisok box
160mm PVC Borewell Dummy
Borewell pipe MS Clamp
50mm PVC Pipe
50mm PVC Elbow
50mm PVC Tee
25mm GI Pipe
25mm GI Tap
50mm Gate Valve
Earthwork excavation in all soils and sub soils except hard rock not requiring blasting with initial lead and lift including re-filling the sides of foundation in layer of 15 cm thick watering , ramming ,depositing the surplus earth in the premises as directed by departmental officers etc., complete as per standard specification. as per SS 20 B TNDSS NO: 23&24VI (S2), VII 9,10
Plain cement concrete 1:4:8 mix ( One Part of Cement,Four Part of Sand and Eight Part of aggregates) using 40 mm ISS HBG metal including cost and conveyance of all materials to work site and all labour charges for mixing, laying,consolidating and curing etc complete as per the standard specifications. TNDSS NO: 28 V, VI (S2) V,VI (S5A) VII
Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9" X 43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT
Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Providing granolithic floor finish of 25mm thickness with plain cement concrete 1:2:4 (One Cement, Two crushed sand (M-Sand) and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers)
Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,
Lowering PVC rigid/ HDPE pipes and specials to trench and laying to proper grade and alignment jointing with PVC couplers with cement paste and testing to the required pressure including conveyance of water for filling during testing etc.,Complete
Borewell to HDPE Tank
Refilling with excavated earth after laying the pipes into the trenches well rammed and compacted the surplus earth over the pipeline trench including leveling the site complete complying with standard specifications including all labour charges etc., Complete as per Standard Specifications.
Supply and run of 4 x 6 sq.mm.(56Nos/0.3mm.Dia) PVC insulated single core unsheathed copper conductor cable of 1100 V on 7/20 G.I. bearer wire for service connection mains (SD 68)
Supply and Run of 4 x 4 sq.mm(84/0.3) PVC insulated Sc unsheathed Cu.Conductor of 1100V grade in 25mm dia G.I pipe ("B"class) suitable bend at both ends with necessary angle iron up right and end supports for mains.SD-73)
Supply and Fixing of Nylon Rope for Borewell
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable withproper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.
R MURUGESAN (BID ID -1114258)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .