Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.7 LAccepted-AOC VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹69.2 L+₹4.3 L (6.59%)Rejected-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L2 | Rejected-AOC Rejected |
Tender Value
₹69.9 L
EMD Value
₹1.3 L
Closing Date
25 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JHANSI
HQ CWE JHANSI
PREVENTIVE REPARI/REPLACEMENT WORK OF 33 KV ISOLATORS, CALIBERATION OF 33/11 KV BREAKERS, HT CONTROL DEVICE, 33/11 KV TRANSFORMERS, CABLES AND CONNECTED ITEMS AT 33 KV MRS AND CONNECTED AREA OF BABINA CANTT UNDER GE BABINA
2021_MES_468629_1
CWE/JHA/BAB/TOKEN/59 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BABINA
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE BABINA
₹1.3 L
Yes
18 Oct 2021
17 Aug 2021
30 Sept 2021
17 Aug 2021
25 Sept 2021
13 Sept 2021
60 days
Amount
Servicing & Repairs to air-break switch /solator off load, rotating type, 33 KV, of 600 Amps capacity , with proper alignment of isolator rotating blades with fixed contact jaws, arcing horns, applying petrolium jelly to moving mechanism, cleaning and lubricating to isolator control assembly, tightening all nuts/bolts of isolator assembly and clamps of jumpers etc, repairing to isolator control assembly and making in proper serviceable condition for smooth functioning, testing and commissioning on load complete all as specified and directed.
Supply & fix in repairs male /mooving contact / rotating blade of HDE copper silver plated of air brake off load isolator switch rotating type 33 KV, of 600 Amps capacity with all fixing nuts bolts etc omplete all as specified and directed. Make Kurgg/Pactil / Jaipuria/BHEL
Supply & fix in repairs fixed female contact made of HDE copper silver plated of air brake off load isolator switch rotating type 33 KV, of 600 Amps capacity with all fixing nuts bolts etc omplete all as specified and directed.
Supplying, laying, jointing and testing in replacement HT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, 33000 volts grade, (earthed) cross sectional area 150 sqmm 3 core as per IS 7098 Pt-II omplete all as specified and directed. Make - KEI/Polycab/Universal/Havells/Asian/CCI
S&F in replacement of outdoor type cable jointing kit for 33 KV (earthed) grade cable heat shrinkable type complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 150/185 sqmm complete all as specified and as directed. Make :- Denson/Raychem/M-seal
Supply, installation, testing and commissioning in replacement of air brake off load isolator horizontal type switch rotating type manually operated highest system voltage 36 KV rated current 600 Amps triple pole ,each pole consist of insulating pedestals 03Nos. on galvanized steel base as per BSS/IS including rotating blade of HDE copper and fixed contacts of same material , spring loaded arcing horns of adequate section to brake magnetizing current of transformer , inulation level 36/70/170 KVp operation from ground level and operating handle for operation complete with both Off and On positions including provision of mechanical locking arrangement omplete all as specified and directed. Makes GR Power Switch Ltd/ PACTIL /Siemens/jaipuria brothers
Supply, installation, commissioning and testing in replacement of 33 KV Current Transformer /CT`s conforms to IS 3156/1992 outdoor type single pole oil immersed and self cooled type of 25 KA/Sec having range 50/5+5 or ratio 100/5+5 suitable for metering and protection equipment installed on control panels including connection of control cables in control panels, terminals block and fixing on bus bar section with suitable size MS channels and angles pedestals and first core class of accuracy 0.5 burden 15 VA, second core class of accuracy 5P 10 burden 15 VA and third core as per site requirement omplete all as specified and directed. Make : Kapco/Jyoti/AE/CG or as per existing design approved by GE
Supply , installation commissioning and testing in replacement Potential Transformer (PT) of 33 KV/110 V outdoor type single pole , oil cooled type suitable for metering equipment installed on control panels including control cables as per site requirement upto control panels terminal block and fixing on bus bar section with suitable size channel and angles pedestals and first core class of accuracy 0.5 burden 50 VA, second winding class of accuracy 3P burden 50 VA. complete all as specified and directed. Make Kapco/Jyoti/AE/CG/ or as per existing design approved by GE all as specified and directed.
Supply, installation, testing and commissioning of lightening arrester SMX type complete with all fittings transmission class , 36 KV 10 KA 50 Hz suitable for system voltage 33/36 KV complete all as specified and directed. Make : Oblum/ ELPRO/ Pactil/ AREVA/ Crompton Greaves/Jaipuria
Disconnecting H.T supply and and servicing of 33 KV line Vaccum circuit breaker (Make-Crompton Greaves/ or other existing on site) of capacity 630/800 Amps and rating 36 KV by cleaning , decarbonising the moving contact points , cleaning with CRC , checking proper operation of moving parts, removing foreign /dust particles from spout gear mechanism and moving parts, repair to motor charge spring mechanism, checking of DC supply wiring , parts tightening all nuts and bolts of components, lubricating moving parts with petrolium jelly in the breaker as directed and testing complete and keeping it on load.
M & L for carry out servicing of transformer of capacity 5MVA , 33/11 KV ratio and carrying out preventive maintenance, technical inspection and testing of with a high skilled mechanic/specialist electric HT line complete as and when directed by Engr-in-Charge. Note :- (a) Checking of winding temperature & oil temperature. In case of unsatisfactory condition shut down the transformer and investigate if either is persistently higher than normal. (b) Checking of oil level and examine transformer for leaks. (If low top up with dry oil, which shall be measured & paid separately). (c) Checking of Dehydrating breather of silica gel (Replacement silica gel if required will be measured & paid separately) (d) Checking and cleaning of primary & secondary bushing from dirt and oil. (e) Checking of oil dielectric strength and presence of water moisture. (f) Checking, cleaning & testing of relays, alarm signal & contacts, fuses, circuits, their operation including change in setting, if necessary complete (g) Checking & testing of earth resistance. (h) Checking & testing of insulation resistance of windings (j) Checking of cable box. (k) Checking & tightening of bolts/nuts and other loose metallic parts. (l) Taking expert opinion in case of abnormal noise, abnormal temperature, electrical faults, alarm signal through Buchholz Relay etc.(l) Painting of the transformer (m) Checking leakges from entire transformer and replacement of packing (n) All testing tools, equipments and other T & P required for technical inspection shall be provided by the contractor.
M & L for disconnecting & taking out old/defective Current Transformer from 11 KV VCB panel, indoor, resin cast epoxy type of 18.4 KA/Sec having ratio 100/5+5 Amps or 60/5+5A or 30/5+5A suitable for metering and protection equipment installed on control panels including connection with control cables as per site requirement upto control panels terminals block and fixing on bus bar section having class of accuracy 5P 10 burden 15 VA complete all as specified and directed. Make : Kapco/Jyoti/CG or as per site requirementMake :- L&T /Crompton/ABB/Siemens/Jyothi
M & L for disconnecting & taking out old/defective PT from 11 KV VCB panel, S & F installation & testing of PT, indoor, comprising of three limbs single phase resin cast PTs of 11KV/110 Voltage ratio, 50 Hz type 200VA class-I accuracy suitable for protection & metering incl making suitable arrangement for fixing in existing VCB panel and connection complete all as specified and directed. Make :- L&T /Crompton/ABB/Siemens/Jyothi
Supply & fix in replacement digital four pole non directional microprocessor based 3 over current + 1 Earth fault with instantaneous trip relay with high set , Aux. supply 20-110 volt DC and setting of time delay, overload and earth fault model MC 61C of complete all as specified and directed. Make L&T or equivalent models of ABB/Siemens / Ashida /CG complete with all connection and testing on load including fabrication works to HT panel for fixing of new relay and wiring connection as directed and specified
M&L for disconnecting power supply from HT VCB /HT panels of capacity 11 KV for repair works , taking out trolly unit & complete servicing of the VCB through decarbonising , cleaning the male /female isolating contacts, lubricating moving part , cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, tightening all nuts and bolts of entire trolley , checking proper operation of trolly , inserting trolley inside and testing on load complete all as specified and directed . Make of HT VCB/RMU /OCB are Crompton/ABB/L&T/C&S /Jyothi/ABB
M&L for servicing ,calibration of all type control relays such as digital earth fault/over current relay , IDMT relay , master trip relay other Aux relays , etc fixed on 11 KV VCB/OCB/RMU for over current and earth fault settings with all respects and making all tripping setting, time delay setting , for smooth functioning of all controls of HT panel including servicing of CTs , PTs , testing with primary injection test kit for load settings and timings of relays , setting tripping and closing of VCB/RMU/ SF-6 breakers complete all as specified and directed . Make of HT VCB/RMU /OCB are Crompton/ABB/&T/C&S /Jyothi
S & F in replacement of vacuum interrupter , suitable for 11 KV HT V.C.B 11 KV 630 /800 Amps capacity cat No. 520/SP complete all as specified and directed. Make Crompton/ABB/L&T/C&S /Jyothi or as per existing design approved by GE all as specified and directed.
S & F in replacement fixed contact block of V.C.B 11 KV 630/800 Amps capacity cat No. 522/SP complete all as specified and directed. Make Crompton/ABB/&T/C&S /Jyothi or as per existing design approved by GE all as specified and directed.
S & F in replacement moving contact block of V.C.B 11 KV 630 /800 Amps capacity cat No. 524/SP complete all as specified and directed. Make Crompton/ABB/&T/C&S /Jyothi or as per existing design approved by GE
S & F in replacement motor & gear assembly 220 Volt AC motorised mechanism of V.C.B 11 KV 630/800 Amps capacity including testing & puting on load cat No. 537/SP complete all as specified and directed. Make Crompton/ABB/&T/C&S /Jyothi or as per existing design approved by GE all as specified and directed.
S & F in replacement closing coil assembly 24/ 110 volts DC for HTV.C.B 11 KV 630/800 Amps capacity cat No. 594/SP complete all as specified and directed. Make Crompton/ABB/&T/C&S /Jyothi or as per existing design approved by GE all as specified and directed.
S & F in replacement tripping coil assembly 24 / 110 volts DC for HT V.C.B 11 KV 630/800 Amps capacity cat No. 599/SP Make Crompton/ABB/&T/C&S /Jyothi or as per existing design approved by GE all as specified and directed.
S & F in replacement auxillary switch (6 No + 6NC) for HT V.C.B 11 KV 630/800 Amps capacity cat No. 562/SP complete all as specified and directed. Make : Crompton/ABB/&T/C&S /Jyothi or as per existing design approved by GE
S & F in replacement contact plug 630/800 Amps for HT V.C.B 11 KV 630/800 Amps capacity cat No. 580/SP complete all as specified and directed. Make Crompton/ABB/&T/C&S /Jyothi or as per existing design approved by GE
S & F in replacement big cam with main shaft for HT V.C.B 11 KV 630/800 Amps capacity cat No. 568/SP complete all as specified and directed. Make : Crompton/ABB/&T/C&S /Jyothi or as per existing design approved by GE
S & F in replacement of 11 KV Silicon polymeric composite Disc insulator B&S type incl galvanised mild steel strap 38 mm X 5 mm, insulator bolts 20 mm dia with suitable washers and nut, suitable for working pressure upto 12 KV as per IS 731/1971 or latest amendment complete all as specified and directed Make :- BHEL/JAYSHREE/AREVA/ABB/PACTIL.
S & F in replacement of 11 kv silicon polymeric pin insulator, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut,11000 volt grade suitable for working pressure 12 KV as per IS 731/1971 or latest amendment complete all as specified and directed . Make :- BHEL/JAYSHREE/AREVA/ABB/PACTIL.
M&L for switch air break gang operated triple pole , mechanically operated mounted on HT insulators (12 insulator type) and MS steel frame with operating mechanism worked from ground level including 32 mmm bore GI medium grade pipe operating rod and operating handle with 11 KV insulation for current rating up to 200 amps 11000 volts with locking arrangement, MS clamps, nuts, bolts and washers etc also incl drop out expulsion type fuse, single pole up to 25 Amps, 11000 volts fuse barrels, incl two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and as directed. Make - Jaipuria Brothers/Pactil/BHEL
S & F and replacement of cross arms, bracing, supports clamps and back plates fabricated from structural steel sections incl nuts & bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed
M&L in replacement of aluminium conductor, steel reinforced (ACSR) of any size/description on LT poles/lines incl stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc incl connecting, commissioning and testing complete all as specified & directed.
M&L for laying 40 mm graded stone aggregate in substations insuch a way that after removing of unwanted grass from substations and then levelling at zero level and laying of stone dust of 75 mm thick at an initial layer and then laying of 40 mm gaded stone aggregate 75 mm thick over the stone dust. The quoted rate also includes cleaning and levelling and filling of sub station before laying aggregate complete all as specified and directed.
Disconnection of faulty HT 11 KV cable of any size from both ends, testing of cables with HT megger or high voltage DC testing mechine and locating the fault in the cable by arranging fault locating Machine (FLC) to pin point at the exact position of fault including the cost for transporting machine at various locations with T&P, manpower and standby power supply for testing of cable all as specified ( Cost also incudes for providing transportation of fault locating machine at different sites as per requirement).
Disconnection of faulty LT 1100 volt cable of any size from both ends, testing of cables with HT/LT megger or high voltage DC testing mechine and locating the fault in the cable by arranging fault locating Machine (FLC) to pin point at the exact position of fault including the cost for transporting machine at various locations with T&P, manpower and standby power supply for testing of cable all as specified ( Cost also incudes for providing transportation of fault locating machine at different sites as per requirement).
Note for item No 32,33 : - The contractor will be initmated on phone followed in writing for faults in HT/LT UG cables. Contractor has to attend site and arrange to bring FLC machine on site within 48 hrs to locate the fault. If the contractor failing to bring the FLC machine for location of fault a penalty of Rs 3000- per cable per day will be charged from his dues.
Supplying, laying, jointing & commissioning in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, (Earthed) cross sectional area 95 sqmm 3 core as per IS 7098 Pt-II ccomplete all as specified and directed. Make - KEI/Polycab/Universal/Havells/Asian/CCI
Description all as per item no 35 here before but of size 120 Sqmm 3 core complete all as specified and directed. Make - KEI/Polycab/Universal/Havells/Asian/CCI
Description all as per item no 35 here before but of size 185 Sqmm 3 core complete all as specified and directed. Make - KEI/Polycab/Universal/Havells/Asian/CCI
S&F of cable jointing Kit 11 KV (earthed) grade cable for outdoor type termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and as directed. Make - M- seal/Denson/3M-Birla/Raychem
Description all as per item no 38 of here above but of size 120 sqmm 3 core complete all as specified and directed. Make - M- seal/Denson/3M-Birla/Raychem
Description all as per item no 38 of here above but of size 185 sqmm 3 core complete all as specified and directed. Make - M- seal/Denson/3M-Birla/Raychem
S&F of cable jointing Kit 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 to 120 sqmm complete all as specified and as directed. Make - M- seal/Denson/3M-Birla
All as per item No 41 of here above but of size 120/185 sqmm 3 core complete all as specified and directed. Make - M- seal/Denson/3M-Birla
Supply and filling Transformer oil confirming to IS-335 (as in toping up or replacement) of 50 KV breaking capacity complete all as specified and as directed. Note :- The work will be carried at different locations in cantt area. Neceaary transport arrangement for shifting machine from one place to another to be arranged by contractor and cost of same to be included in unit rate.Contractor will bring new oil in sealed container and cost of same will included in unit rate.
Comprehensive/preventive maintenance for smooth functioning of step down transformer indoor/outdoor type of capacity 63 KVA to 630 KVA with off load tapchanger 11 KV/433 volts grade by performing the following works :-
(i) The company technician from reputed company of transformer repairing/manufacturing will visit the installation bimonthly to ensure the smooth functioning of transformer and will provide preventivemaintenance/servicing as and when required. (ii) The technician should be from reputed company of transformer repairing company duly qualifiedandconversent with functioning of transformers (iii) The technician will check the following points:- (a) Checking of minium and maximum peak load, voltage, current on each phase LT and HT side. (b) Checking of temprature of winding and oil in conservator and transformer. (c) Checking of tightness of all gasket joints including HT & LT cable boxes and checking any leakage of oil. (d) Checking HT and LT endjoints at tgransformerend heating, sparking or carbon deposit and loose connections (e) Checking of connections of marshelling box if installed on transformer and checkingof functioning of buchholz relay. (f) Testing of dielectric strength of transformer oil after every 3 months intervel and submit test report. (g) Examination of cracks & loose connections on bushings & terminals (h) Checking of proper working of all indicators/meters/guages. (j) Testing of earth results after every 3 months interval and submit test report. (k) All test report/check list for each transformer will be initated by contractor as directed. The cost of stationary/test sheets/registerof records deems to be included in unit rate..
Supply, erection and connection new Pre- streessed concrete HT poles 152 mm x 152 mm at top and 152 mm x 260 mm at bottom, class 9, 11.0 mtrs long including making alternate white and red strips 30 cms height (05 Nos strips) numbering the poles by 2" height letters complete all as specified and directed. Make :- Hindustan pressed concrete, Faridabad/M/s Indian PCC poles/M/s concrete Udyog, Jhansi
Supply, erecting and fixing in true vertical position, steel tubular swaged LT pole (410 SP-31) 9.0 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with two coats of aluminium paint over one coat of red oxide primer and incl taking down existing old unserviceable poles complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete all as specified and directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately. (a) PS Steel Tubes Pvt Ltd (b) India Electrical Poles.(c) United Engineers Kanpur(d) National tubing Co. Kanpur e) BCW Kanpur
Disconnecting electric outdoor/indoor transformer capacity from 63 KVA to 160 KVA from HT/LT terminals and lowering down/getting out from 2/4/6 pole structure/plinth or inside sub station for major repairing/minor repair.Note:- Cost of T&P and labour required for the work to be included in the rate quoted.
All as per item No 47 here before but of capacity 200 KVA to 315 KVA complete all as specified and directed.
Description all as per item no 47 here before but of capacity 400 KVA to 630 KVA
Draining out complete transformer oil from transformer of from 63 KVA to 160 KVA capacity at site which found major repair and storing the oil in suitable container (container to be provided by the contractor to keep aside for re-use (after repair) and lifting of core assembly by opening of top cover and other items for inspection/examination by GE/AGE E/M and lowering/fixing of core assembly in its original position after inspection to make it ready for transportation to carry out repair work in workshop
All as per item no 50 here before but of capacity 200 KVA to 315 KVA complete all as specified and directed.
All as per item no 50 here before but of capacity 400 KVA to 630 KVA complete all as specified and directed.
M&L for transportation of unserviceable transformer of capacity from 63 KVA to 315 KVA (with help of vehicle and hydra crane) to workshop and return back for installation it on original position/location after repairing from workshop complete all as specified and directed. (Rate is deemed to be inclusive of transportation, T&P and man power)
All as per item no 53 here before but of capacity 400 KVA to 630 KVA complete all as specified and directed.
Description same all as per item No 53 here-in-before but shifting of serviceable transformer (with help of vehicle and hydra crane) upto 630 KVA from MES store Yard/Sub Stn(indoor/outdoor) for installation in place of unserviceable transformer and back after replacing with repaired transformer all as specified and directed
M&L for Opening of top cover by unscrewing nut, bolts & washers etc and taking out core assembly from tank by disconnecting from tap changer HT & LT side bushing stud to outside by dismantling the channel and disconnecting star delta connection of transformer having capacity from 63 KVA to 160 KVA.
All as per item no 56 here before but of capacity 200 KVA to 315 KVA complete all as specified and directed.
All as per item no 56 here before but of capacity 400 KVA to 630 KVA complete all as specified and directed.
M&L for Removing the lamination in proper manner carefully for taking out serviceable/ unserviceable HT/LT coils from the limbs of capacity from 63 KVA to 160 KVA transformer complete all as specified and directed.
All as per item no 59 here before but of capacity 200 KVA to 315 KVA complete all as specified and directed.
All as per item no 59 here before but of capacity 400 KVA to 630 KVA complete all as specified and directed.
M& L in repairs for rewinding of HT coils with copper wire DPC/super enameled high quality matching with existing gauge and impedence including requisite insulating paper/material in each layer of winding after taking down old existing winding of HT leg coils complete all as specified and directed.
All as per item No 62 here-in-before but LT coils with copper strips complete all as specified and directed..
Note : For srl item No 59 to 63 The rate quoted against these items is inclusive necessary provision and cost of all types of insulating materials and heating/ varnishing etc.
M& L for Inserting of HT/LT coils on limbs rewinded here in before/old after cleaning of lamination in proper way and also after insulating the limbs with requisite insulating materials on limbs in between limbs/coils upto 63 KVA to 160 KVA capacity transformer complete all as specified and directed.
All as per item no 65 here before but of capacity 200 KVA to 315 KVA complete all as specified and directed.
All as per item no 65 here before but of capacity 400 KVA to 630 KVA complete all as specified and directed.
M& L for Re-arranging the top lamination over coils in proper manner including fixing of channel soldering in between coils as necessary and brazing of star delta connection with tap changer from 63 KVA to 160 KVA capacity transformer complete all as specified and directed.
All as per item no 68 here before but of capacity 200 KVA to 315 KVA complete all as specified and directed.
All as per item no 68 here before but of capacity 400 KVA to 630 KVA complete all as specified and directed.
M& L for Baking the core assembly in the oven duly varnishing the coil to improve IR value and to eliminate moisture content from 63 KVA to 160 KVA capacity transformer complete all as specified and directed.
All as per item no 71 here before but of capacity 200 KVA to 315 KVA complete all as specified and directed.
All as per item no 71 here before but of capacity 400 KVA to 630 KVA complete all as specified and directed.
M& L for Inserting the core assembly after baking in the tank (before inserting tank to be cleaned by removing all deposit sludge etc including drying) and making connection with HT/LT bushing studs and closing the tank top cover by fixing of suitable size of nut, bolts and washers for transformer of capacity 63 to 630 KVA (Top cover gasket will be measured and paid separately). Note :- (i) Repairing of transformer have to be completed within 15 days duration. If the contractor has fails to repair the transformer with in 15 days contractor has to provide another same capacity of transformer without extracost. (ii) In case the defective/unserviceable transformer not repaired & installed on site with in specified period of 15 days from the date of handing over to contractor, a penal recovery @ 5000/- per day will be charged from his dues.
Supply and fixing in renewal of porcelain transformer bushing on LT 1.1 KV side including brass stems conical bush and gasket for indoor/outdoor transformer of the following capacity :-
Capacity 63 KVA to 315 KVA.
Capacity 400 KVA to 630 KVA.
Supply and fixing in renewal of porcelain transformer bushing HT 11 KV including brass set stems conical bush and gasket for indoor/outdoor transformer of following capacity complete all as specified and directed.
Capacity 63 KVA to 315 KVA.
Capacity 400 KVA to 630 KVA.
S&F in renewal of silica get breather assembly with vent pipe and new silica gel for indoor/outdoor transformer of the following capacity :-
Capacity 63 KVA to 315 KVA.
Capacity 400 KVA to 630 KVA
Supply and changing Silica gel from breather after heating till requisite/desired colour is achieved complete all as specified and directed.
ON load centrifuging and dehydration including filtration and cleanning of transformer oil by dehydration machine electric operated without any shutdown of transformer including testing oil sample before and after dehydration and dehydration and filtration oil complete all as specified and directed. Note :- (i). Dielectric strength of oil after dehydartion shall be more than 45 KV at 2.5 mm gap on load (ii) Transformer oil required for top up shall be measured and paid separately. (iii) Contractor have to arrange the dehydration machine and testing kit from his own resources without any extra cost. (iv) The work will be carried at different locations in cantt area. Neceaary transport arrangement for shifting machine from one place to another to be arranged by contractor and cost of same to be included in unit rate.
M&L for spray painting of transformers located at various locations in Babina Cantt with two coats of synthetic enamel paint first quality of approved colour/shade after preparation of old painted surface to entire satisfaction of Engr-in-charge incl writing SM and MES Nos for the capacity of transformer from 63 KVA to 200 KVA complete all as specified and as directed. Note :- The work will be carried at different locations in cantt area. Neceaary transport arrangement for shifting machine from one place to another to be arranged by contractor and cost of same to be included in unit rate.
All as per srl item No 80 here in before but for the capacity of transformer 250 to 630 KVA capacity complete all as specified and directed.
Supply,laying and testing in replacement of cable XLPE insulated,screened,PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 V grade with multi stranded aluminium conductor of size 70 sqmm 3.5 core as per IS 7092 Pt-I complete all as specified and as directed. Make :- KEI/Polycab/Universal/Havells/Asian/CCI
All as per item No 82 here in above but of size 25 sqmm 4 core complete all as specified and directed.
All as per item No 82 here in above but of size 16 sqmm 4 core complete all as specified and directed.
All as per item No 82 here in above but of size 25 sqmm 2 core complete all as specified and directed.
All as per item No 82 here in above but of size 16 sqmm 2 core complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 3.0 mtr deep below GL with top edge of the plate not less than 2.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to earth lead of GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth lead connected to equipments and watering pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and testing of earthing complete and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 . Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. 2. Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit . 3. On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 2 ohms.
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 3.0 mtr deep below GL with top edge of the plate not less than 2.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth lead connected to equipments and watering pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and testing of earthing complete and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 . Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. 2. Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit . 3. On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 2 ohms.
M&L earthing complete with copper earth plate electrode 600mm x 600mmx3.15mm thick,thick burried directly in ground vertically to a depth not less than 3.0 mtr deep below GL with top edge of the plate not less than 2.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to earth lead of copper strip 20 x 3.15 mm by means of bolts, nuts, check nuts and washers of GI or steel and thimbles and other end of the earth wire connected to DB and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 and also including making test point for testing of earthing made out of gun metal or phosphorous bronge size 75x75x25 mm complete all as specified and directed. Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.2. Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate. 3. On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values. Note:- Earthing test will be carried out and if desired result item not achieved the earthing will be redone to achieve desired result without any extra payment.
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for pole / cable / foundation etc incl getting out in soft /loose soil complete all as specified and directed.
Excavation in trenches in any type of soil not exc 1.5 mtrs wide and exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed.
Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick after cable are laid and tested complete all as specified and directed.
Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directed at a level not exc.1.5 mtr above the ground level complete all as specified & directed.
M&L for PCC cable cover class HV type 1 flat size 300 mm x 180 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed.
M&L for PCC cable cover class LV type 1 flat size 250 mm x 150 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed.
M&L for fine and clean sand (river sand) free from sharp materials in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning.
M&L for steel tubing galvanised, light grade ISI marked, complete with fittings laid in trenches/fixed along with poles etc as protection to cables of size 80 mm dia bore complete all as specified and directed.
M & L for road cutting incl excavation in trenches for laying HT UG cable in pipe not exc 45 cm wide and n.exc 60 cm depth or as per site requirement for laying of GI pipe 100 mm dia light grade & making good the disturbed surfaces with cement concrete (1:3:6) type C-1 and top surface neatly finished as per existing to match with the existing complete all as specified and directed. Note :- 80 mm GI pipe (light grade) will be paid and measured under separate item . The cut /excavated surface will be repaired on same day with PCC failing which a penality of Rs 500 per day will be recovered from contractor dues.
M&L for cleaning of electric substation/installations including cutting/removing of grass, bushes and trimming of branches of trees inside the premises and also roemoving from the substation premises complete all as specified and as directed. If the contractor has fails to clean the substation after intimation throgh telephonically and followed through letter with in 48 hours a penality of Rs 10/sqm per day will be charged from his dues.
M&L for cutting of tree branches upto 3 mtr away from the over head line including removing and disposal of cut branches outside the Cantt land complete all as directed. The Span of OHelectric line will be 40 - 50 mtr. Necessary T&P, man power and transport will be arranged by contractor without any extra cost. Necessary electric line shut down must be taken before trimming/cutting tree branches by contractor. Any lapse/incident happened due to negligence resulting loss to man and material will be responsibility of contractor & no any claim in this regard will be admissible to the dept. If the contractor fails to clean the area of line after intimation throgh telephonically and followed through letter with in 48 hours a penality of Rs 200 per span per day will be charged from his dues.
S&F for replacement & testing commissioning of outdoor type bus bar cubical panel board made of 3 mm CRCA MS sheet outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 300 Amp capacity colour coded heat shrinkable sleaves and mounted on DMC/Epoxy insulator with MCCB 4 pole of Capacity 200 Amp 25 KA (Ics =Icu=100%) including one coat of redoxide powder coated finish , mounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, complete all as specified and directed. Make - Maclayers/shalabh/Universal switch gear
M&L for shifting of transformer from 4 pole/2 pole structure to PCC platform and construction of platform for the transformer of size 2m x 2m with the following (a) PCC (1:4:8) type D-2 with 40mm grade crushed stone aggregate 15cm thick in foundation (b) Brick work in CM 1:6 with sub class 'B' old size bricks (230mm thick walls) in periphery platform (c) 100mm thick RCC flooring (1:3:6) type C-1 using 20mm graded stone aggregate on top reinforced 12mm dia MS bar 100mm c/c including use and waste of form work. (d) Rendering 15mm thick in CM (1:6) on exposed surfaces (e) The platform shall be such that its height 1.5 mtr above the nearest road level and 45 cm below ground complete all as specified and directed. Note : Cost of construction of PCC foundation included in the quoted rate.
M&L for plastering in CM (1:4), 10 mm thick in repairs on fair faces of brick work or concrete surface/cable duct/floor complete all as specified and directed.
M&L for PCC work using 20mm graded stone aggregate 1:3:6 type C1 for cable duct/ foundation/ mass filling complete all as specified and as directed.
Supply and fixing of GI strip 32 x 6 mm fixed in ducts / on wall / in trenches / floors etc for earthing complete fixed to equipment / test point / earth electrode complete all as specified and directed
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius built in CM (1:4) as in foundation of equipment, platform, ramp, supporting pillars of pipes, protection wall of sub station incl demolistion of existing brick work built in cement mortar complete all as specified and directed.
Supply, erecting and fixing in replacement of true vertical position, steel tubular swaged pole (410 SP-55), 11 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.). The quoted rate includes cost for shifting of existing Cross arms, bracing, ACSR conductors insulators, GI wire from eisting pole to new poles complete all as specified and directed. Note :- Excavation including earth work and PCC foundation will be measured and paid separately. Make :- (a) PS Steel Tubes Pvt Ltd (b) India Electrical Poles.(c) United Engineers Kanpur(d) National tubing Co. Kanpure) BCW Kanpur
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling for erection of pole and mass concrete for poles complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling for erection of pole/fncing post/stay and mass concrete including form work for poles complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including form work for poles complete all as specified and directed.
Supply, erecting and fixing in replacement of true vertical position, prestressed concrete pole 9.0 mtr long 102 mm x 172 mm at top and 152 mmx 279 mm at bottom class 10 (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size) including taking down of old unserviceble pole & shifting of cross arms ACR conductor , GI wire, insulator, street light brackets etc complete all as specified and directed. Note :- Excavation incl earth work and PCC foundation will be measured and paid separately. The old unserviceable pole obtained from dismanting shall be remove by the contractor form cantt area/MOD. If the contractor has not removed the dismantled item a penality of Rs.500.00 per pole will be charged from the contractor as a penality. Make : Hindustan Pressed concrete Faridabad / M/s Indian PCC poles / M/s Concrete Ugyog Jhansi.
M& L for MS fabrication work made out of structural steel sections as in frame work including MS angles/flats/plain sheets of appropriate guage, cut to size and made to appropriate shape suitable for transformer shead/gates/ base frame of eqpt/frame work of substn/ frame for fixing lights including nut bolts and washers in any size, welding bracing work and bending cold or hot drilling holes for bolts in any shape or size as required including one coat of primer and two coats of synthetic enamel paint to the entire steel surface including taking down of the existing for modifying as per requirment at site all are as specified and directed.
M & L for Stay assembly complete with accessories as shown in electrical plate No. 1 of 20 mm dia of stay rod, 180 cm long etc complete all as specified and directed. (for HT poles)
Supply and fix loop type insulator vitreous procelain, white , brown or green, large size with overall dimensions 140mm, clearence of hole 25.5mm dia ball and socket type brown, white or green single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts grade etc complete all as specified and directed.
Supply and fix galvanised stay strand, 7/4 mm complete all as specified and directed.
S & F incl stringing GI continuous GI earth wire of size 4 mm / 3.15 mm dia on HT/LT poles as in cradle guards / earth wires, binding including taking down complete all as specified and directed.
S & F of cable path indicator made up of precast RCC (1:2:4) type B-0 (TMT bars 6 mm dia) using 12.5 mm graded stone aggregate of size 650X400 X 40 mm duly enamel paint red/brown colour and marked as HT/LT cable as directed and installed at 400 mm above and 250 mm below ground level complete all as specified and directed. Note - Cost of earth work & PCC included in the quoted rate.
M/S SHIVA TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .