COMMANDANT_ELECT/SE
FHQ BSF NEW DELHI
Replacement of Left Out Border Flood Lights along with restructuring of Source BOPs in Area of Responsibility of SHQ BSF Jammu under FTR HQ BSF Jammu SH Replacement of Poles, UG Cable and Flood Lights For Bop S M PUR and Bop Chamliyal of 101 BN BSF
2026_BSF_914849_1
01/SE(ELECT) /NIT/FTR-JMU/ENGG/2025-26
Open Tender
Electrical Works
180 days
IN AOR OF BOP SM PUR AND BOP CHAMLIYAL OF 101 BN
Please refer Tender documents.
16 documents required · 16 mandatory
₹0
₹6.9 L
25 Jun 2026
25 Jun 2026
13 Jul 2026
25 Jun 2026
10 Jul 2026
25 Jun 2026
25 Jun 2026 - 10 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and laying of 3.5 x 185 Sqmm aluminum conductor, PVC insulated, PVC sheathed, armored underground cable of 1.1 kV grade, conforming to IS 7098 standards, through 100 mm (ID) x 120 mm (OD) SN8 DWC HDPE pipe with proper socket coupling. The work includes excavation to a depth of up to 75 cm, laying of the cable with necessary protection, and refilling of the trench, complete in all respects as required. | - | Mtrs | 2,690 | - |
| 2 | Supplying and laying of 3.5 x 95 Sqmm aluminum conductor, PVC insulated, PVC sheathed, armored underground cable of 1.1 kV grade, conforming to IS 7098 standards, through 100 mm (ID) x 120 mm (OD) SN8 DWC HDPE pipe with proper socket coupling. The work includes excavation to a depth of up to 75 cm, laying of the cable with necessary protection, and refilling of the trench, complete in all respects as required. | - | Mtrs | 1,658 | - |
| 3 | Supplying and laying of 3.5 x 25 Sqmm aluminum conductor, PVC insulated, PVC sheathed, armored underground cable of 1.1 kV grade, conforming to IS 7098 standards, through 63 mm (ID) x 77 mm (OD) DWC HDPE pipe with proper socket coupling. The work includes excavation to a depth of up to 75 cm, laying of the cable with necessary protection, and refilling of the trench, complete in all respects as required. | - | Mtrs | 776 | - |
| 4 | Supplying and making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
i)3.5 x 185 Sqmm (57 mm) | - | Set | 0.4 | - |
| 5 | Supplying and making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
ii)3.5 x 95 Sqmm (45 mm) | - | Set | 0.4 | - |
| 6 | Supplying and making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
iii)3.5 x 25 Sqmm (28 mm) | - | Set | 0.4 | - |
| 7 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron,60 cm long and fixing the same in ground as required | - | Each | 0.2 | - |
| 8 | SITC of cubical canopy type out door hut type Junction box from 3 mm thick CRCA sheet having size 500 mm (L) x 350mm (D) x 500mm (H) fabricated with CRCA sheet 3 mm thick mounted on 04 Nos 50 mm x 50 mm x 6 mm thick angle iron frame, erected in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation & refilling,hinged front & back doors with locking arrangements,,cable tray with provision of fixing of glands at hte bottom,antirust design, air ventilation grooves, water drop proofing arrangement ,insluators,earthing studs,nuts bolts etc.as required including connections,painting with primer & finish paint with synthetic enamel paintwith 04 nos aluminium bus bar strip suitable for 200 A,415 V capacity with suitable insulated support for AL bus bar complete as required. | - | Nos | 7,658 | - |
| 9 | Supplying, installation, testing and commissioning of outdoor hut type feeder pillar suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 3 mm thick CRCA sheet, double door type with inbuilt locking arrangement, 3 mm pasivated gland plate, depth not less than 350 mm and all connection (incoming and outcoming) will be taken out in cable alley. The panel shall be cleaning, processing and finishing with 7 tank process for powder coating in approved shade and supplied with suitable pedestal of 50 mm x 50 mm x 6 mm angle iron frame with 800 mm 6 Nos long legs, 200 Amp 4 nos high conductivity aluminium bus bar with DMC/SMC support, earth bus as the same size as the phase bus running across the length of the panel, solid connection from main bus bar to switchgear, control wiring with 1.5 sqmm FRLSH insulated multi stranded copper conductor with cable alley, including providing and fixing following switchgear, fixing LED phase indicator and following accessories etc complete as required. The panel shall be mounted on suitable cement concrete foundation 30 cm below the ground level and 30 cm above the ground level. The panel should not less than 1150 mm x 1850 mm x 450 mm as CPRI approved. Note:- (i) Panel size indicated is nominal. The actual size shall be as per the drawing approved by the Deptt.
Incomer
i) MCCB 04 Pole 200 Amp 35/36 Ka , L frame, adjustable thermal and adjustable magnetic setting, - 02 nos with spreader terminals
ii) MFM 4410 LCD Meter CL 1.0 WC441010OOOO 9425 - 2 No.
iii) SPD Type 2, 40KA, 3P + N AUSP023PN40 - 1 No
iv) Residual Current Circuit Breaker (Model No - BG406330, 4 Pole, 63 Amp and Sensitivity 300 mA, - 2 Nov) CTs 200/5A, CL-1, 15 VA, Cast Resin for metering - 3 Nos.
vi) LED Phase Indicating Lamps - 1 Set of 03 Nos.
Outgoings
i) MCCB 04 Pole 125 Amp Fixed type 25 Ka breaking cap. 04 nos
ii) MCCB 04 Pole 63 Amp Fixed type 16 Ka breaking cap. 02nos | - | Set | 2,42,991 | - |
| 10 | Supplying, installation, testing and commissioning of outdoor hut type feeder pillar suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 8 mm thick CRCA sheet, double door type with inbuilt locking arrangement, 3 mm pasivated gland plate, depth not less than 300 mm and all connection (incoming and outcoming) will be taken out in cable alley. The panel shall be cleaning, processing and finishing with 7 tank process for powder coating in approved shade and supplied with suitable pedestal of 50mm x 50 mm x 6 mm angle iron frame with 4 Nos 800 mm long legs, 200 Amp 4 nos high conductivity aluminium bus bar with DMC/SMC support, earth bus as the same size as the phase bus running across the length of the panel, solid connection from main bus bar to switchgear, control wiring with 1.5 sqmm FRLSH insulated multi stranded copper conductor with cable alley, including providing and fixing following switchgear, fixing LED phase indicator and following accessories etc complete as required. The panel shall be mounted on suitable cement concrete foundation 30 cm below the ground level and 30 cm above the ground level. The panel should not less than 1025 mm x 1250 mm x 450 mm as CPRI approved.
Note:- (i) Panel size indicated is nominal. The actual size shall be as per the drawing approved by the Department.
Incomer
i) MCCB 04 Pole 125 Amp 25 Ka , L frame, adjustable thermal and adjustable magnetic setting, = 02 nos with spreader terminals
ii) MFM 4410 LED Meter CL 1.0 WC441010OOOO 9425 - 1 No.
iii) Residual Current Circuit Breaker (Model No - BG406330, 4 Pole, 63 Amp and Sensitivity 300 mA, - 2 No
iv) LED Phase Indicating Lamps - 1 Set of 03 Nos.
Outgoings
i) MCCB 04 Pole 63 Amp Fixed type 16 Ka breaking cap. = 03 nos with spreader terminals | - | Set | 1,08,408 | - |