Col Pawan Kumar, CWE
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
PROVN OF LIFT FOR PANCHJANYA AUDITORIUM UNDER GE DRONACHAL
2026_MES_775537_2
84283/E8
Open Tender
Civil Works
Item Rate
180 days
Dronachal
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Yes
GE Dronachal
₹49,840
Yes
27 Oct 2026
27 Oct 2026
11 Nov 2026
27 Oct 2026
9 Nov 2026
4 Nov 2026
27 Oct 2026 - 4 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3½ core complete all as specified and directed. | 200 | RM | - | - |
| 2 | Supply, installation, testing and commissioning of 4-Way TPN Distribution Board (DB) double door, wall-mounted, dust and vermin proof, fabricated from CRCA sheet steel, powder coated, complete with copper busbar, neutral link, and earth bar, suitable for 415V, 3-phase, 4-wire system; comprising one 32 Amp TPN MCB as incomer with adjustable thermal-magnetic protection and adequate breaking capacity, and 04 Nos. 16 Amp SP MCBs as outgoing feeders with C-curve tripping characteristics; including all internal wiring with FRLS copper conductors, interconnections, gland plate, cable glands, lugs, ferruling, proper labeling, earthing of DB body, and all accessories required for safe operation. The DB shall be installed at site, properly aligned and fixed, tested for insulation and functionality, and commissioned complete in all respects as per site requirements and directions of Engineer-in-Charge | 1 | Each | - | - |
| 3 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 3 core complete all as specified and directed. | 20 | RM | - | - |
| 4 | Supply, installation, testing and commissioning of 10 kVA single-phase servo voltage stabilizer suitable for Nibav Series IV Max Home Lift operation, having input voltage range of 170–270 V and output voltage stabilized at 230 V ±1%, air-cooled type with copper-wound transformer, high efficiency, and fast correction rate; complete with digital display for input/output voltage, overload protection, short circuit protection, surge protection, and time delay system. The stabilizer shall be wall/floor mounted as required and connected through suitable 32 Amp input/output MCB/isolator, including all necessary internal wiring, earthing, cable terminations, lugs, glands, and accessories. The work includes proper fixing, testing under load conditions, and commissioning to ensure smooth and safe operation of the lift system, complete in all respects as per site requirements and as directed by Engineer-in-Charge | 1 | Each | - | - |
| 5 | The work comprises supply, delivery, unloading, installation, testing and commissioning of one Nibav Series IV Max Home Lift or equivalent complete with prefabricated cylindrical structure, passenger cabin, vacuum drive system, integrated control panel, landing doors at required levels, safety interlocks, emergency alarm system, battery backup for lowering, all standard accessories and fittings as per manufacturer specifications; including transportation to site, handling, positioning, assembly, alignment, fixing and anchoring of the lift system, trial runs, performance testing, final commissioning and handover complete in all respects; the work also includes manufacturer warranty for motor, vacuum seal and complete lift system as per OEM terms and conditions, and shall be executed strictly in accordance with OEM guidelines and applicable standards. (NOTE : The make of lift shall got be approved by GE before commencement of work within 30 days of acceptance of contract. If command make approved not available then lowest bidder shall provide the make with satisfactory performance in last 1 year minimum under renowned public/private entities) | 1 | Job | - | - |
| 6 | Excavation or road cutting in trenches not exc 1.5m wide and not exc 1.5M depth for laying of cable, getting out including forming bottom surface to required level and gradient in hard/dense soil complete all as specified and directed. | 30.38 | Cum | - | - |
| 7 | M&L for Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard/dense soil. complete all as specified and directed. | 18.03 | Cum | - | - |
| 8 | Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed. | 12.34 | Cum | - | - |
| 9 | Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed. | 12.15 | Cum | - | - |
| 10 | M & L Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all as specified and directed. | 1.2 | Per 1000 No | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
BOQ_892778.xls
BOQ • 0.24 MB
84283TenderDocuments.pdf
Tender Documents • 1.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .