| 1 | L1₹24.9 LAccepted-AOC BOOTH NO 15 SHOPPING COMPLEX URBAN ESTATE PHASE II JALANDHAR CITY PIN 144022 | JALANDHAR | PUNJAB | 144022 | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.7 L+₹80,338.40 (3.23%)Rejected-Finance 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | L2 | Rejected-Finance L2 | |
| 3 | L3₹27.4 L+₹2.5 L (9.98%)Rejected-Finance 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | JALANDHAR | PUNJAB | 144001 | L3 | Rejected-Finance L3 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
CERTAIN REPAIRS TO FAFA THIMAIYYA FAFA NALWA MES COLONY GANGA ROAD INCL MAP NALWA ROAD UNDER AGE B/R-II OF GE (EAST) JALANDHAR CANTT
2024_MES_661526_1
GE/JULL/ET-12/2024-25
Open Tender
Civil Works
Item Rate
273 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹50,000
Yes
15 Oct 2024
23 Jul 2024
25 Sept 2024
23 Jul 2024
17 Sept 2024
7 Aug 2024
Amount
Taking down cement plaster of any description thickness including raking out joints hacking for key scrubbing down with water, complete all as directed.
M&L for 15 mm thick cement mortar 1:6 on brick or concrete surface finished even and smooth without using extra cement, complete all as specified and as directed.
M&L for preparing new plastered surfaces of walls by applying two coats of oil bound distemper over a coat of primer and one coat of birla white putty 2mm in two layers complete all as specified.
M&L for 15mm thick cement plaster on brick or concrete surfaces in cement mortar (1:4) mixed with integral water proofing compound in the proportion recommended by manufacturer, surfaces finished fair and even complete all as specified and as directed. (WPC shall be measured and paid separately under appropriate item of this BOQ).
M&L for preparation of new surfaces of walls including cornices, plasters etc (Plastered or unplastered surfaces) and applying two coats of cement base paint, complete all as specified and as directed
Supply only integral water proofing compound (ISI Marked) all as specified and as directed.
M&L for plastering 5mm thick in cement mortar (1:3) finished even and smooth without using extra cement as on ceiling complete all as specified and as directed
M&L for three coats of white wash on newly plastered surfaces of ceiling, including preparation of surfaces, complete all as specified and as directed.
M&L for preparation of old surfaces of walls including cornices, plasters etc (Plastered or unplastered surfaces) and applying one coats of cement base paint, complete all as specified and as directed
M&L for preparation of old decorated surfaces of walls, washing rubbing down and stooping of distempered and painted surfaces and applying one coat of oil bound distemper, complete all as specified and as directed
M&L for one coat of white wash over old plastered surfaces of ceiling including preparation of surface complete all as specified
M&L for hacking out old broken glass (any thickness, size quality or description) from wooden or steel frame glazed with putty or fixed with beads, complete all as specified and as directed
S&F sheet glass ordinary quality 3.0 mm thick in square not exc 0.50 Sqm each pane glazing with oil putty, clip in metal frame and wooden beading in wooden frame, complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing) and disposal of rubbish outside MD land complete all as directed.
M&L for non-skid ceramic coloured tiles (premium quality) 7 to 8mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors set and jointed in neat cement slurry and pointed in while or coloured cement to match over and including 15mm thick bedding layer in CM 1:6 complete all as specified and as directed. Make :- Somani/ Kajari/ Johnson.
M&L for non-skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors set and jointed in neat cement slurry and pointed in while or coloured cement to match over and including 15mm thick bedding layer CM 1:6 complete all as specified and as directed. Make :- Somani/ Kajari/ Johnson.
Ditto all as per srl item No. 16.00 above but in skirting and 10mm thick rendering as backing coat of CM 1:4 complete all as specified and as directed.
M&L for 25mm thick cement concrete (1:2:4) type B-1 (12.5 mm graded crushed stone aggregate) to receive the top layer of tiles, complete all as specified and as directed
M&L for coloured glazed tiles of size 450x 350x7 mm thick fixed with neat cement slurry in vertical surface to wall pointing in white/coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and as directed. Make:- Somani/Kajaria/Johnson.
S&F 18 to 20mm thick granite (of any type) tiles machine cut , in skirting/dado laid over cement screed 10 mm thick in CM 1:4 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing and dismentling of existing granite complete all as specified and as directed.
Demolition of reinforced cement concrete in ground floors and paving n.exc 15 cm thickness (reinforcement to cut as required to facilitate demolition)complete all as specified and as directed
M&L for reinforced cement concrete (1:2:4) type B-1 (20 mm graded aggregate) slab supported on wall, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed
M&L for TMT bars MS 10 mm and over dia and cut to length, bent to shape required including cranking bending spirally for hooping for clos hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed
M&L for form work to soffits of suspended slabs such roof slabs, floor slabs, shelves, landings and similar work, not exceeding 200mm thick (horizontal or slopping) rough finished surfaces of concrete flat or shelfs etc. complete all as specified and as directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n. exc. 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc. 10cm but n. exc. 20cm wide for rough finished surfaces of concrete, complete all as specified and as directed.
Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area not exc 1.5 Sqm each all as specified.
All as per srl item No. 26.00 above, but area exc 1.5 Sqm and not exc 4 Sqm each complete.
Taking down shutters of any description exc 1 Sqm and not exc 2 Sqm each complete all as specified and as directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, hold fast rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete all as specified and as directed.
S & F pressed steel frames 125x60mm as per IS for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including PCC 1:5:10, type B0 (20mm aggregate) filling in steel frame complete all as specified
All as above but 105x60mm size complete all as specified and directed.
S&F for 35mm thickness of factory made flush shutter solid core construction with block board core & ply wood face panels, commercial type on both side including 40 x 6 thick 2nd class Hard wood lipping on edge, complete all as specified and as directed.
S&F glazed and skelton shutters of IInd class hard wood, factory made 35mm thick open rebated and prepared to receive glass, gauge etc (without sash bars) edging of framing plain, chamfered or rounded with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I, Section 8, Clause 8.24(a) complete all as specified and as directed
S&F steel window 1.25 mm thick Box type (Primer coated) ERW hollow P section of size 60 mm x 25 mm single rebated comprises glazed and gauzed skelton shutter EWR sec 50 mm x 20 mm and 1 mm thick and two openable leaf consisting two Nos sash bar of T- section 20 mm x 3 mm complete welded to frame with one vertical mullion of EWRR box type T- section of size 60 mm x 25 mm and 1.25 mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B-1 four Nos for each window including following fittings welded to failed shutters:- (a) Hold fasts 150 mm long of 12 mm x 3 mm made to shape-04 nos per window. (b) Handle of Z sec 20 mm x 25 mm, 100 mm long-1 Nos of leaf (c) MS tower bolt 150 mm long 02 Nos per leaf. (d) Z sec 20 mm x 25 mm , 100 long of hollow square 15 mm x 20 mm x 63 mm welded to hinges – 01 Nos per leaf (f) MS pintal hinges of size 75mm x 12 mm -02 Nos per lear (g) Fabrication and fixing arrangement as per drawing No CEJZ/TD -06/07. Note:- Glass, wire mesh and painting shall be measured and paid separately under appropriate items.
Ditto as per item No 34 above, but in ventilators complete all as specified and as directed.
S & F framed work such as grills, gratings, etc .with ends of bars shouldered and/ or riveted , or forget into spikes ; framed guard bars barallel iron doors and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for 3.00 mm thick glass sheet, ordinary quality and glazing with oil putty in square n. exc 0.5 sq. m in each panen complete all as specified and as directed.
M&L for 3.00 mm thick figured glass, pin head type and glazing with oil putty in squares not exc. 0.5 sqm in each pane complete all as specified and as directed.
S & F in repair factory made built-in steel cup board with pressed steel frame and pressed steel shutter 1.00mm thick fixed to masonry wall by hold fasts, made out of 25x3mm flat iron including MS hanging rod of 20mm dia with brackets fixed on inner side of cupboard, provn of MS peg set 3 pegs fixed on inner side of shutter and 1.00mm thick black sheet 3 Nos shelves as shown in Drg including spray painting with two coats of synthetic enamel paint over one coat of red oxide primer all around on steel surfaces of frame and shutter and fixing in PCC (1:2:4) all as directed and shown on Drg No CEJZ / TD-1104/08 Sheet 1/2 to 2/2, including dismantling of shelves/shutter etc complete all as specified and as directed.
S & F Hasp & Staple aluminium 100 mm , including bolt to hinge plate and fixed with screws with Cup Board shutter, All as Specified
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. Tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixing in the frame at the site as per specification & drawing
S&F PVC solid door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing complete.
S&F floor door stopper 140mm of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor all as specified and as directed by Engineer-in-Charge
S&F galvanized mild steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tinned tacks complete all as specified and as directed.
S&F in repair galvanized mild steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tinned tacks complete all as specified and as directed.
S&F 250mm long mild steel sliding door bolts stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified.
S&F 100mm size butt hinges medium weight cold rolled mild steel all as specified
S&F100mm size stainless steel butt hinges for fixing to PVC doors all as specified.
S&F 200mm long mild steel tower bolt stove enamelled black with bright bolt all as specified.
S&F 150 mm mild steel pressed handles oval type, stove enamelled black complete all as specified.
M&L for preparation of new wood surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed
M&L preparation of new or previously untreated steel surfaces of any description, n. exc. 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed.
S&F aluminium anodised tower bolts 200 mm size fixed with machine screws complete all as specified and as directed.
S&F aluminium anodised Bow Handles 150 mm size fixed with machine screws complete.
S&F mild steel 300mm ordinary rat tail rod pattern springs including roller and roller plate welded to steel frame/ screwed to wooden frame, complete all as specified and as directed.
M&L Galvanised iron water tubing 15 mm bore, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc including taking down the existing tubing complete all as specified and as directed.
Ditto all as per srl item No. 56.00 above but for 20mm bore tube complete.
S&F in repair Stop valve (ISI Marked), 15 mm cast copper alloy chromium plated fancy type with long shank & cup (concealed type) with capstan heads, screwed down, high pressure, with crutch or butterfly handle screwed for 15mm bore iron, complete all as specified and as directed.
S&F in repair 15mm angle stop valves (ISI Marked), cast copper alloy, chromium plated, screwed down, high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and, complete all as specified and as directed.
S&F in repair Bib tap chromium plated, cast copper alloy suitable for 15mm bore iron pipe with long body fancy type, complete all as specified and as directed. Make:-Jaquar/Cera/ESS - ESS.
S&F squatting pan WC Orissa pattern size 580 x 440 mm white with integral foot rest with P or S trap including provn of lime concrete bedding including breaking up existing damaged WC seat and connecting flush pipe etc and make good to floor complete all as specified and as directed Make:- Hindware/ Parryware/ Cera.
S&F in repairs Vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern) including seat cover and flushing pipe for pedestal pipe etc. complete all as specified and as directed. Make:- Hindware/ Parryware/ Cera.
S&F in repair seat cover for water closet pedestal pattern (ISI Marked) all as specified and as directed.
S&F in repair PVC valveless, syphonic action type flushing cistern low level white with inlet ball valve float and handle, 10 ltr capacity including brackets complete all as specified and as directed. Make:- Hindware/ Parryware/ Cera.
S&F in repair PVC connection fiber, reinforced 45cm long with brass check nut and PVC washers at both ends complete complete all as specified and as directed.
S&F in repair health faucet (ABS body)mild steel chromium plated suitable for 15mmdia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. Make:- Jaquar/ESS - ESS/ Cera.
S&F in repair Soap dish stainless steel chromium plated fixed with brass screws and rawl plug complete all as specified .
S&F in repair acrylic corner set of 3 pieces (Size - 11", 9" & 7" and minimum thickness 5mm) as per sample approved by Engineer-in-charge all as specified and as directed
S&F in repair 500 ltr UV protected antimicrobial (white) rotational moulded polythylene water storage tank triple layer in white colour (Cylindrical vertical with closed top) hosted and fixed in position with 20mm ball valve high pressure, PTMT with polythene float and fly nut including dismantling of existing tank of any description complete all as specified. Make:- Sintex(pure)/ Polycon/ Sheetal.
S&F in repair 20mm for ball valve high pressure, PTMT with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed in repair complete all as specified and as directed
S&F in repair Pillar tap (Swan Neck), cast copper alloy, with capstan heads, 15mm bore dia of pipe chromium platted screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed. Make:- Jaquar/ Cera/ ESS - ESS.
S&F in repair brass chromium plated shower rose of 125mm size, with or without swivel joints including fixing to steel pipe (min size 300 mm) or union complete all as specified and as directed. Make:-:- Jaquar/Cera/ESS - ESS.
S&F in repairs Vitreous china wash hand basin , white, flat back 550x400mm including one number brass CP waste coupling ,32mm dia , PVC waste pipe with connector , brackets 2 nos including cutting for and pinning in ends of brackets complete all as specified. Make:- Parrryware /Cera/ Hindware.
S&F in repairs sinks with drainage board made of stainless steel 1 mm thick kitchen with plugs, washers, waste coupling and waste pipe, over all size 915 mm x 460 mm bowl size 410 mm x 330 x 160 mm including bedding in CM on dwarf wall or incl fitting contilever brackets and conection union to pipe complete. Make :- Nirali/ Jayna/ Bluestar.
M&L for mild steel pipe 25 mm dia curtain rod with PVC coating fixed in the MS hooks, and finials/side brackets (both side), shade fixed in repair all as specified.
M&L for PVC (SWR) floor trap with grating including jointing to waste pipe fixed with solvent cement (diameter of outlet in 75mm) including taking out damaged floor trap in any type and position complete all as specified and as directed
Cleaning of floor trap and applying of cement around the floor trap with sealant compound for arresting the seepage at any circumstances (Kitchen, Bathroom and Toilet) all as specified and as directed by Engineer-in-Charge. Make:- WACKER SILICONES (GP Silicone Sealant)
S&F in repair flexible PVC Waste pipe of approved quality 32 bore, 75 cm long with one end socketed fixed to waste coupling, compete all as specified and as directed
S&F PVC (SWR) pipes 110 mm dia with single socketed in any length with rubber ring joints fixed on brick walls or laid in trenches with PCC 1:4:8 complete houching with bedding including demolition and braking up existing pipes with fittings complete all as specified and as directed.
Ditto all as per srl item No. 80.00 above but 75 mm dia
S&F PVC (SWR) bends 110 mm with access door complete all as specified and as directed.
Ditto all as per srl item No. 82.00 here-in-before but 75 mm with access door
S&F for 110mm PVC (SWR) vent cowl complete all as specified and as directed.
S&F Brass chromium plated tubular towel rail 20mm dia , D type, 60cm long between flanges in repairs complete all as specified and as directed. Make:- Jaquar/ Cera/ Gem.
S&F in repair CP grating 125mm dia with centre hole all as specified and as directed by Engineer-in-Charge
Demolition of brick work as in walls/parapet wall,s removing grass fungus weed, roots of trees completely, grown on roof/wall surfaces, complete all as specified and as directed.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) complete all as specified and as directed.
All as per srl item No. 88.00 above, but except bricks
Demolition of brick tiles incl creed backing single layer as in roof covering complete all as directed.
Demolition of mud in roofs any thickness including plastering and leeping (whether full thickness removed or only a part thereof) all as directed.
M&L for PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in benching, roof padding, roof kerbs or mud stops, coping etc rounded or chamfered on edges complete all as specified and as directed
M&L for 10mm thick cement plaster in cement mortar (1:3) mixed with integral water proofing compound in the proportion recommended by manufacturer, on concrete roof surfaces finished even and fair, including cleaning the roof top by scraping down with water etc all as specified and as directed by Engineer-in-Charge (WPC shall be measured and paid separately under appropriate item of this BOQ).
Cleaning the surface and made free of dirt, foreign particle, laitance followed by grinding all all protrusion to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expiation contraction. Cutting the grooves with suitable cutter machine in V-groove filled with repairs mortar/ microconcrate/ general purpose grout as recommended proportionally as per recommendation of manufacture. Making of Gollas at all the corners with polymer modified mortar (1:4) cement sand with 3.5% acylic of cement weight complete all as specified and as directed.
Supply and applying high build elastomeric waterproofing coating based on pure hydrophobic polyurethane cold applied of spray/brush applied, membrane with an elongation of 280% and tensile strength of 2.7N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88% solid content. The system includes final base preparation, epoxy primer 1:1 (Resin; harder) application with 100% water dilution and Pure polyurethane application in 2 coats with a total min consumption of 1.25 kg per Sqm. Application should be done with Graco sprayer by a company authorised applicator” complete all as specified and as directed
M&L for Brushing neat cement slurry with 3 kg of cement per sq. meter on surface of complete, complete all as specified and as directed.
M & L for applying Bitumen Primer shall be applied on plastered surface of roofs at the rate of 0.40 Kg/Sqm of Surface area of roof for use in water proofing and dump proofing treatment complete all as specified and as directed.
M&L Painting the roof surface with a coat of hot blown paving industrial bitumen 85/25 as a bonding material in two coats one on primed surface & 2nd on APP based polymeric membrane at the rate of 1.20 kg/sqm all as specified.
M&L for APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3mm thick rainforced with five layer polyster non wove fabric ( wt. Not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified
M&L for 40 mm thick brick tiles with 15 mm thick bedding layer of CM 1:3 laid on 2nd bitumen coated surface and joints grouted flush mortar 1:3 mixed with 5% of crude oil by weight of cement, complete all as specified and as directed.
Ditto all as per Item No 100 above, but except brick tiles, complete all as specified and as directed.
M&L Cutting out cracks to V-section in existing RCC roof slabs or terracing , cleaning out & filling solidly with a hot mixture of bitumen and clean dry sand 1:1 ( by weight) all as specified
M&L for repairing of R.C.C projections, chajjias, roofs, facia and ceiling etc by necessary preparation. Scarping, cutting, chiselling derusting and cleaning exposed reinforcement, surfaces of damaged, loose R.C.C surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregates and reinforcement with welded mesh of weight exc 2 kg per sqm but n.exc 3kg/sqm (if reqd) with or without facia and finished with cement and sand mortar (1:3) using coarse sand necessary form work and applying two coats of finishes to match with the existing surfaces in at any height complete all as specified and as directed by Engineer-in-Charge
M&L for flush pointing in cement mortar 1:3 on brick tiles laid flat including racking out joints/ pointing, hacking for key, scrubbing down with water complete all as specified
M &L for Water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WCs etc shall be as under:- (i) Application of Two component acrylic modified cementitious coating (aa) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coating and achieve a gripping profile that is clean, dry and free from laitance and dry other form of surface contamination. The installation instructions in manufacture's published literature should be strictly complied with, including but not limited to the following:- (bb) Chipping out any visible cracks in "V-Groove" pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/Dr Fixit 302 SBR latex/ Perma latex SBR/FOSROC Nitabond SBR latex/Asian paint latex as required. Final cleaning of surface with power grinder, wire brush, hair brush & vacuum pressure if required. (cc) Dampen all surfaces immediately ahed of application of Acrylic modified Cementitious coating of sika Top Seal-107/Brush Bond FOSROC/Dr Fixit/STP/CICO.
(dd) Whilst the surface is still damp from saturation (S.S.D), apply one coat of Acrylic modified cementitious coating of SIKA Top Seal-107 /Brush Bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturer's instructions. (ee) Apply glass fabric sheet of SIKA Fab 1/FOSROC/Dr Fixit/STP whilst the first coat is wet. (ff) Once touch dry, apply second coat of Acrylic modified cementitious coating of SIKA Top Seal -107 /Brush Bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturer's instructions on the entire area. (gg) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direction right angle to the previous coat. (hh) The waterproofing coating should be taken to a height minimum 300mm above the finished floor level on the vertical surfaces three sides including dismantiling of existing tiles. (hh) The waterproofing coating should be taken to a height minimum 300mm above the finished floor level on the vertical surfaces three sides including dismantiling of existing tiles. (kk) A protection plaster 12-15mm thick) in CM 1:3 admixed with appropriate integral water proofing compound has to be applied on the walls. Admixture: SIKA Plastocrete Plus/FOSROC/DR
Fixit/STP/CICO conforming to IS 2645. Providing and applying a protection screed of 50mm thick 1:4, cement sand mortar admixed with SIKA Plastocrete over the applied water proofing coating on horizontal surfaces. Admixture: SIKA Plastocrete Plus/FOSROC/DR Fixit/STP/CICO conforming to IS 2645. (ll) All the corners and joints should be pretreated with an elastic waterproofing sealing tape with a woven bonding mesh on each surface and an elastic expansions zone in the centre of Make SIKA Seal Tape/FOSROC/Dr Fixit/STP.
(mm) The membrane has to be protected in accordance with the manufacturer's recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer's recommendations. (nn)Waterproofing treatment has to be carried out through applicators authorised by the respective manufacturer's and approved by GE. (nn)Waterproofing treatment has to be carried out through applicators authorised by the respective manufacturer's and approved by GE. (ii) All the joints of pipes and traps within the sunken portion shall be sealed properly by epoxy sealent. (iii) All CI traps in sunken slab to be enclosed with PCC 1:1.5:3 (Min 15cm) all around. (iv) The sunken portion shall be filled with PCC 1:5:10 type E-2 (using 40mm stone aggregate) complete all as specified. (v) Providing drainage spout pipe GI pipe 40mm dia bore light grade upto outside of outer wall ( Approx 450mm to 600 mm long ) including cutting to existing wall and making good the disturbed surface complete all as specified and as directed. (vi) Providing 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in flooring for laying floor finish all as specified.
Note:-Item No 25 (iv) ,(v) &(vi) shall be measured and paid seprately.
M & L Cement concrete 1:5:10 type E-2 (using 40mm stone aggregate) as in sunken flooring complete all as specified and as directed.
S & F drainage spout pipe GI pipe 40mm dia light grade upto outside of outer wall (Approx 450mm to 600 mm long ) including cutting to existing wall and making good the disturbed surface complete all as specified and as directed.
M & L 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in flooring for laying floor finish, complete all as specified.
Demolition of cement concrete in ground floors and paving n. exc 15 cm thickness (below or above the ground level) complete all as directed.
M&L for cement concrete type D-2, 1:4:8 (40mm graded aggregate) 75mm thick as in sub base of flooring, complete all as specified and as directed.
M&L for 75mm PCC 1:3:6 type C1 {using 20mm graded crushed stone aggregate) as in plinth protection and path finishing the surfaces even and smooth with using extra cement with joint/panel filled grade 'A' bitumen compound complete all as specified and as directed.
M&L for chequered cement concrete tiles 30cm x 30cm x 18 to 20 mm thick set with grey cement and pigments jointed and pointed in neat coloured cement slurry in floors over and including 15 mm thick cement screed bed in cement mortar (1:6) including demolition of old tiles/concrete floor, all as specified and as directed
M&L for laying 60mm thick machine pressed precast concrete interlocking paver block and shape and size conforming to IS-15658-2006 of M-35 grade with grey cement and pigment including demolition of old paver blocks complete all as specified and as directed. Note : The sample shall be got approved from the GE before build procurement and lots shall be got tested independently by the GE
M&L for 25mm sand cushion, filling 30mm under floors or in foundations including watering and consolidation complete all as specified and as directed
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in sides of rounded or chamfered on edges of interlocking/ chequered tiles, bed block concrete, complete all as specified and as directed
M&L for chromium plated peg set of 5(PTMT), fixed with screws and plugging to rear side of door shutter in bath, complete all as specified and as directed.
Grubbing/ uprooting of trees,grass,bushes etc from brick wall/roof tiles or any surfaces of bldg including dismantling the requried brick work /rooftiles/mud concrete etc for uprooting the vegetation etc and make good the same to match existing surfaces with same material or concrete 1:2:4 type B-1 after pouring the chemical (which destroy the growth of vegetation to place where vegetation removed).The rate shall include for scaffolding or any other arrangment required during this process upto 10 mtr height complete all as specified
Cleaning of over head tank of any description and any capacity descaling, washing complete with soap solution and removing vegetation around the over head tank/plate form including opening and reconnecting with GI tubing and writing month of cleaning with stencil having 3 inch height as site requirement complete all as directed by Engineer-in-Charge
S&F for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;
S & F in repairs 20mm dia curtain rails, Stainless steel , chromium plated fixing in cup board with brackets, stops, rollers etc, all as specified
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails, post etc and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250 Quaity 'A' , including dismantling complete all as specified and as directed.
S&F stainless steel plate rack of superior quality size 2400mm 3600mm with not less than 8 kg complete all as specified and as directed. Make:- Nirali/Jayna/ Bluestar.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed.
M&L for 6mm thick asbestos cement fiber, corrugated or semi-corrugated sheets fixed with L-type or J-type or cranked hook bolts in roofs, walls etc all as specified.
Ditto all asper item No. 124 above but except sheets
M&L for Asbestos cement 6mm thick serrated ridge for corrugated or semi corrugated sheets fixed with L-type or J-type or cranked hook bolts in roofs, walls etc fixed in repairs, complete all as specified.
S & F Pre- painted galvatume aluminum zinc coating AZ 150, GI based corrugated steel sheet 0.45mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F Pre-painted Galvalume Aluminum Zinc Coating AZ 150, GI based Plain Steel Sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete as directed.
M&L pre cast RCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in Manhole cover slab set in CM 1:4, complete all as specified and as directed.
S&F TMT bars 8mm dia cut to length bent to shape required including binding with mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed
S&F for Providing precast cement concrete louvres and jallies, 25mm thick (measured solid), PCC 1:2:4, Type B0 (12.5mm graded aggregate) including all mouldings with frame Set in CM 1:4, complete all as specified and as directed.
S&F in repair stainless steel kitchen rack of size 750 x 800 x 200mm (thickness of sheet not less than 0.63mm) with mild steel brackets and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. Make:- Nirali/Jayna/ Bluestar.
NATIONAL BUILDERS (BID ID -3080670)
S S CONSTRUCTION (BID ID -3092179)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .