Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-Finance 2 4 J S TOWER G 4 BLOCK A AVVAIYAR STREET MEENAMBAKAM CHENNAI 600 027 | KANCHIPURAM | TAMIL NADU | 600027 | L1 | Accepted-Finance L1 | |
| 2 | L2₹4.9 L+₹6,006.20 (1.25%)Accepted-Finance NO 13 43 ANNAMALAI NAGAR 3RD STREET WEST MAMBALAM CHENNAI 600 033 | CHENNAI | CHENNAI | TAMIL NADU | 600033 | L2 | Accepted-Finance L2 | |
| 3 | L3₹5.3 L+₹51,577.80 (10.7%)Accepted-Finance | L3 | Accepted-Finance L3 | |
| 4 | L4₹5.4 L+₹57,289 (11.9%)Accepted-Finance | L4 | Accepted-Finance L4 |
Tender Value
Refer Docs
Closing Date
20 Feb 2024, 9:00 amClosed
Principal
GPTC SEVVAPET
Supply of EEE Lab Items
2024_DoTE_425008_1
202/B3/2024EEELAB Items
Limited
Laboratory and scientific equipment
Supply
10 days
Sevvapet
Refer to PDF
2 documents required · 2 mandatory
₹0
Exempted
22 Feb 2024
14 Feb 2024
21 Feb 2024
14 Feb 2024
20 Feb 2024
14 Feb 2024
14 Feb 2024 - 20 Feb 2024
EEE DEPARMENT EQUIPMENTS ITEMS
Two speed Pole changing circuit with motor - 2 nos. of 3 phase 16A Main Contactors - 3 phase input, Fuses - Speed 1, Speed 2 and Stop Push Switches - Provision to connect two different pole 3 phase windings Screen Printed Board, MS tube stands, Acrylic back cover
AC Contactor 230V/440V, 16A
Push Button with NO/NC Elements
Proximity switch
Programmable Logic Controller Kit With digital inputs and outputs Model and software - PLC Systems with and software: Micro810 Controller with 8 digital inputs and 4 digital outputs - 8 Digital input switches and 4 Digital outputs with LED indication. - 24V operated, built-in power supply, additional 5V, 1A Power Supply - 4 NO contacts of the relays connected at outputs of the PLC and a buzzer - Computer connectivity to download the program using USB Port with cable - Professional Programming Component Connect Workbench - Windows 7 Environment - To write Simple Ladder logic and test using digital inputs and outputs - To write Simple Ladder logic and test using timer, counter, branching and subroutines I3 processor based system with Windows 8 OS is to be provided by the institute for using this PLC
Working module for wire and test the control for jogging in 3 HP cage motor - 1 no. 3 phase 16 A Contactor, 1 no. of Control relay - 3 Phase input proper termination - Stop, Start and Jog Push Buttons, Fuses and Power Terminations - Control wiring termination - Wooden casing
Thermal overload relay timing characteristics - one no. 3 phase, 16A Main Contactor - one no. 2-4.5A Overload relay - Provision to connect 3 phase load externally - (The Institute should provide the Load) - 3 phase input, Fuses Wooden casing
Control circuit for Semi automatic Star Delta Starter suitable for 5 HP - 3 nos. of 440V, 16 A Contactors Main / Star / Delta - Start / Stop / Push Button Switches - Switch for manual delay operation (semi automatic) Control wiring termination, Powder Coated MS Stands, Acrylic back cover
Control circuit for automatic Star Delta Starter suitable for 5 HP - 3 nos. of 440V, 16 A Contactors Main / Star / Delta - 1 no. AC Timer (for automatic operation) - Start / Stop / Push Button Switches - Switch for manual delay operation (semi automatic) Control wiring termination, Powder Coated MS Stands, Acrylic back cover
Dynamic braking control of AC Motor suitable for 3 - One 3 phase, 440V, 16 Amps Main Contactor - One 230V DC, 12A Contactor for connecting DC Supply - AC Timer, Rectifier for DC Power Supply, Variac to be connected externally On/Off Push Switches
Two speed Pole changing circuit - 2 nos. of 3 phase 16A Main Contactors - 3 phase input, Fuses - Speed 1, Speed 2 and Stop Push Switches - Provision to connect two different pole 3 phase windings Screen Printed Board, MS tube stands, Acrylic back cover
Wire and test the control circuit for forward and reverse operation - 2 nos. of 3 phase 16A Main Contactors - 3 phase input, Fuses - Speed 1, Speed 2 and Stop Push Switches - Provision to connect two different pole 3 phase windings Screen Printed Board, MS tube stands, Acrylic back cover
Automatic Rotor Resistance Starter using PLC Automatic Rotor Resistance Starter using PLC - To be used with PLC and 5HP 3 phase Rotor Resistance Induction Motor - Start and Stop Switches - 4 nos. of 3 phase 16A Contactors - Inputs to PLC and outputs from PLC - Provision to wire external resistances in the rotor circuit - Institute has to provide 9 external resistances to be connected in the rotor circuit Provision to wire control and power wiring - Screen Printed Board, MS tube stands, Acrylic back cover b. Starting resistance 25 Ohms, 9 nos. ( in 3 Rheostat form) - To be connected to the rotor winding of the slip ring motor - To be shorted in 3 stages at the time of starting
Single Phase Preventer using PLC - 1 no. 3 phase 16A Main Contactor - 3 transformers and associated circuits as input to the PLC - PLC output as control output - 3 switches to test the phase failure - Proper termination for 3 HP cage motor Wooden casing
PLC based Star Delta Starter suitable for 5 HP Motor - 3 nos. of 16A, 3 phase Contactors, - Start and Stop Push Buttons, Fuses and Power wiring termination Control wiring termination, Powder Coated MS Stands, Acrylic back cover
Automatic Rotor Resistance Starter - 5HP 3 phase Rotor Resistance Induction Motor - Start and Stop Switches - 4 nos. of 3 phase 16A Contactors - Inputs to PLC and outputs from PLC - Provision to wire external resistances in the rotor circuit - Institute has to provide 9 external resistances to be connected in the rotor circuit Provision to wire control and power wiring Screen Printed Board, MS tube stands, Acrylic back cover
Lift working model - 3 floors (Ground plus two floors) sheet metal model - Floor request switches and Floor sensing switches – 6 inputs to PLC - Cabin – stepper motor with controller/geared DC motor with forward and reverse control Proper termination to wire inputs and outputs to PLC
Water Level controller working model - Level sensors as input to the PLC - Water tap as output from the PLC - Water Pump motor control using outputs of the PLC - Water Tank with sump and Overhead tank model - 2 Levels sensor switches and 12 V Pump - 24 V Solenoid valve to drain water, 12 V and 24V Power Supply Foot valve arrangement to take the water from the sump
Conveyor working model - Sloped conveyor with shawl sheet metal model - Proximity sensor to sense the shawl - input to PLC - Start, Stop Push switches and FWD / REV toggle switch, Buzzer output to give alarm Conveyor belt with geared DC Motor drive
PLC control circuit for jogging and forward – reverse operation - 2 nos. of 3 phase 16A Main Contactors - 3 phase input, Fuses - Stop, Start Fwd, Jog Fwd, Start Rev, Jog Rev Push Switches - Inputs for PLC, Control from outputs of PLC - Proper termination for 3 HP cage motor Screen Printed Board, MS tube stands, Acrylic back cover
JAYAM ELECTRONICS
SYSTEMS
KUTTY ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .