Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.7 LAccepted-AOC 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | 1 | Accepted-AOC L1 Bidder | |
| 2 | 2₹38.5 L+₹5.8 L (17.7%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | 2 | Rejected-Finance Not L1 Bidder | |
| 3 | 3₹38.9 L+₹6.2 L (18.9%)Rejected-Finance 14 4A KALI PRASAD C HAKRABORTY ST CAL KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | 3 | Rejected-Finance Not L1 Bidder | |
| 4 | 4₹39.1 L+₹6.4 L (19.6%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | 4 | Rejected-Finance Not L1 Bidder | |
| 5 | 5₹39.5 L+₹6.8 L (20.9%)Rejected-Finance 15 JOGENDRA NATH GHOSAL ROAD P S BELGARIA KOLKATA 700 057 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700057 | 5 | Rejected-Finance Not L1 Bidder |
Tender Value
₹29.8 L
EMD Value
₹59,600
Closing Date
1 Oct 2021, 6:00 pmClosed
GE NORTH KOLKATA
GE NORTH KOLKATA 46 BT ROAD KOLKATA 50
REPAIR MAINTAINANCE AND REPLACEMENT OF ALL WORN OUT JUNCTION BOXES BUSBAR JUNCTION ELECTRIC FEELDER PILLARS CONNECTED CABLES SWITCHGEARS SERVICE CABLE AND CONNECTED ITEMS FOR PHASE WISE EQUAL DISTRIBUTION OF ELECTRICAL LOAD AT VARIOUS LOCATIONS I
2021_MES_470916_1
8082/21-22/GE/N/KOL/E8 OF 2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
KOLKATA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH KOLKATA
₹59,600
Yes
27 Oct 2021
26 Aug 2021
4 Oct 2021
27 Aug 2021
1 Oct 2021
25 Sept 2021
Amount
Excavation in trenches not exceeding 1.5 m width or n exc 10 sqm on plan and n.exe 1.5 m in depth for taking out/laying of cable,foundation etc and getting out in soft/loose soil complete all as specified and as directed.
Returning and filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft / loose soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtrs and depositing where directed including spreading, leveling at a level not exceeding 1.5 mtr from the starting point complete all as specified and as directed
Supply, Laying,connecting,testing and commissioning of XLPE insulated and PVC sheathed ,armoured heavy duty UG cable with stranded alluminium conductors 120 sqmm x 3.5core,1100 Volt grade, laid in trenches through pipe in road crossing, and the like, ,compleate all as specified and as directed including taking down old unserviceable one. Note :- (i) Pipe and bricks for cable protection and sand cushioning shall be measured and paid separately as per site . Make Polycab / Finolex / Havells / / KEI / HPL / Mescab / Standard / RR Kabel/ Dynamic cable.
All as per item No. 4 here-in before but for cable of size 95 sqmm x 3.5 core.
All as per item No. 4 here-in before but for cable of size 70 sqmm x 3.5 core.
All as per item No. 4 here-in before but for cable of size 50 sqmm x 3.5 core.
All as per item No. 4 here-in before but for cable of size 35 sqmm x 3.5 core.
All as per item No. 4 here-in before but for cable of size 25.0 sqmm x 3.5 core.
All as per item No. 4 here-in before but for cable of size 16.0 sqmm x 4 core.
All as per item No. 4 here-in before but for cable of size 10.0 sqmm x 2.0 core.
Supply, Laying,connecting,testing and commissioning of XLPE insulated and PVC sheathed ,armoured heavy duty UG cable with stranded alluminium conductors 120 sqmm x 3.5core,1100 Volt grade, laid on surface / wall / roof / pole / through pipe ,compleate all as specified and as directed including taking down old unserviceable one. Note :- (i) Pipe and bricks for cable protection and sand cushioning shall be measured and paid separately as per site . Make Polycab / Finolex / Havells / / KEI / HPL / Mescab / Standard / RR Kabel / Dynamic cable.
All as per item No. 12 here-in before but for cable of size 95 sqmm x 3.5 core.
All as per item No. 12 here-in before but for cable of size 70 sqmm x 3.5 core.
All as per item No. 12 here-in before but for cable of size 50 sqmm x 3.5 core.
All as per item No. 12 here-in before but for cable of size 35 sqmm x 3.5 core.
All as per item No.12 here-in before but for cable of size 25.0 sqmm x 3.5 core.
All as per item No. 12 here-in before but for cable of size 16.0 sqmm x 4 core.
All as per item No.12 here-in before but for cable of size 10.0 sqmm x 2.0 core.
Material and labour for sand cushioning with clean dry sand in trenches for cable protection complete all as specified and as directed. Note:- Punned depth shall only be measured and paid.
Supply and lay sub class 'B' bricks dry in trenches for cable protection laid with its longitudinal axis perpendicular to the cable axis complete all as specified and as directed.
All as per item No. 21 above but laying only(serviceable bricks obtained from item No. 04 to 11 shall be re-used)
Supply and lay GI pipe 80 mm bore (dia) light grade in trenchescrossing for protection of cable with necessary fittings as required complete all as specified and as directed. Make:- Prakash / Utkarsh Tubes Ltd / Jindal / Zenith / Bansal / Nezone / M/S BST Infratech Ltd.
All as per item No 15 but size 50 mm bore.
All as per item No 15 but size 25 mm bore.
Supply and lay GI pipe 80 mm bore (dia) light grade in trenches/road/surface/pole/wall crossing for protection of cable with necessary fittings as required complete all as specified and as directed. Make:- Prakash / Utkarsh Tubes Ltd / Jindal / Zenith / Bansal / Nezone / M/S BST Infratech Ltd. Note:- Clamps shall be measured and paid separately
All as per item No 26 but size 50 mm bore.
All as per item No 26 but size 25 mm bore.
Cutting hard standing / road for laying of cable / protection pipe not exceeding 30cm wide and not exceeding 30cm deep and making good after laying pipe/cable etc with PCC 1:3:6 Type C2 matching with existing road complete all as specified and as directed
Material and labour for PCC (1:2:4) type B-1 (using 20mm graded aggregate) for coping of poles upto 30cm above ground including necessary form work, and finishing the surfaces even and smooth without using extra cement including demolition of damaged PCC coping complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C-2 with 40mm graded aggregated for foundation of electric pole, bus bar and panel board etc including necessary form work and demolition complete all as specified and as directed
Supply and fix in replacement MCB double pole/SPN 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified as directed. Make : Havells / L&T / Indoasian / HPL / Standard / C&S / Legrand.
All as per item No - 32 here in above but for 40 Amps.
All as per item No - 32 here in above but for 63 Amps.
Supply and fixing in replacement MCB single pole 6 to 32 amps, 240 volts, with all incoming / outgoing connections with proper size of aluminium lugs to including taking down old unserviceable MCB complete all as specified and as directed Note:(i) Cost of alluminium lugs shall be included in the unit rate. Makke:- Havells / L&T / Indoasian / HPL / Standard / C&S / Legrand.
Supply and fixing LED building security light fitting 25 watt energy saving versatile pressure die-cast aluminium IP65 building security luminaire complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ complete including taking down old unserceable light fitting all as specified and directed. Make:Havell's Cat Part No: LHEWDRP7PN1W025/ Century Cat No SPSP025C0918/ Jaguar Cat No. LPCRSRT25WXC or equivallent model ln C&S / HPL / Bajaj / Orient / Simoco.
Materials & labour for painting to Steel Tubular poles ( including bracket for light fitting) from the ground level with one coat black bituminous paint up to a height of 1.20 m and balance portion up to top with one coat of aluminium paint, first quality, including preparation of old painted surfaces with one border line of 20 mm wide with blue synthetic enamel paint in between black bituminous and aluminium paint and writing pole Nos in letters and figures 20 mm size complete all as specified and as directed for 9.0 mtr long pole. Make of paint:- asian / Berger / Jenson & Nicholson / Shalimar.
Supply, install,testing and commissioning factory made, Powder coated, vermine proof, weather proof, dust proof,out door type LT junction box of size not less than 75cm x 60 cm x 30cm (H x Lx B), Conforming to the norms of CPRI, with 04 Nos alluminium bus bar of capacity 400 Amps fabricated with 03mm thick MS sheet and 40mm x 40mm x 05mm angle iron frame and incoming / outgoing cable holes at the bottom. The panel shall be embedded with 40mm x 5mm MS angle iron frame and 45cm above the normal ground level complete with PCC foundation 1:2:4 type B1 complete including taking out old unserviceable one , .The panel board shall comprise of following items all as specified and as directed by Engr-In-Charge ( Note : PCC foundation work shall be included in unit rate) (i) Changeover Switch of 250 Amp ,415 V ,Cat No.IHCNFO0250 of Havell's/ C&S Cat No. CSCS250NM4CO or equivallent in Legrand or Indoasian / L&T / Standard. - 01 Nos (ii)Bus Bar of 400 Amp rating - 04 Nos (iii)Phase indicator (RYB ) lamps LED type . -01 set
Supply and fix Hot pressed moulded SMC junction box of 300mmx150mmx170mm to be fixed to pole with provision of aluminium bus bar rated 150Amp of size 25x6 mm and one number SP MCB 10 Amp 'C' Series, 230 Volt inside the box fixed including taking down old unserviceable junction box complete all as specified and as directed. (Make-: Model-JB- MI0100 of Hensel/ Rittal/Emitter/GSJB 3020 of Sintex.
Supply and fix sheet metal enclosure /TPN DBs (Double door) 4 way with 200 amps rated busbar suitable for MCB including taking down old unserviceable enclosure one complete all as specified as directed. Make: Havells / Indoasian /L & T / C&S / HPL/Standard / Legrand.
Supply and fix sheet metal enclosure single pole & neutral for DBs (Double door) 4 way with 200 amps rated busbar including taking down old unserviceable enclosure one complete all as specified as directed. Make: Havells / Indoasian /L & T / C&S / HPL/Standard / Legrand.
All as per item No 3 here in above but for 8 way SPN DB. Make: Havells / Indoasian /L & T / C&S / HPL/Standard / Legrand.
All as per item No 3 here in above but for 12 way SPN DB. Make: Havells / Indoasian /L & T / C&S / HPL/Standard / Legrand.
Supply and fix in replacement MCB triple pole & neutral 63 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified as directed. Make: Havells / Indoasian /L & T / C&S / HPL/Standard / Legrand.
Supply and fix in replacement MCB triple pole & neutral 40 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified as directed. Make: Havells / Indoasian /L & T / C&S / HPL/Standard / Legrand.
Supplying, fixing, connection and testing MCCB, 4 pole, 63 Amp capacity, 16/18 KA rupturing capacity, AC 415 volts with fixed thermal and magnetic settings including taking down old unserviceable MCCB complete all as specified and directed.. (Make: Havells / Indoasian /L & T / C&S / HPL/Standard / Legrand.
Supplying, fixing, connection and testing MCCB, 4 pole, 100 Amp capacity, 16/18 KA rupturing capacity, AC 415 volts with fixed thermal and magnetic settings including taking down old unserviceable MCCB complete all as specified and directed.. Make:- Havells / Indoasian /L & T / C&S / HPL/Standard / Legrand.
Supplying, fixing in replacement , connection and testing MCCB, 4 pole, 200 Amp capacity, 36 KA rupturing capacity AC 415 volts with fixed TM range including taking down old unserviceable MCCB complete all as specified and directed Make:Havells cat no.IHLLSEBF0200/ INDOASIAN Cat part No 830116/L&T/C&S / HPL / Standard/ legrand.
Supply and fixing in replacement LED post top lantern with post top made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP 65 protection including 35/40 Watt LED lamp with all accessories and fixing in existing post including taking out old unserviceable/broken light fittings complete all as specified and as directed. Make: HAVELLS Cat Part No: RUBYPT35WLED757PSYMTOPC/ / Century Cat No. APBY040C0875 or equivallent of Jaguar/ Philips / HPL / Bajaj / Orient / Simoco.
Materials & labour for earthing complete with galvanized earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth lead wire 4.0 mm of by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe(light grade), alternate layers of charcoal and salt, including 20 mm bore GI tubing for watering to earth electrode, earth lead connected to test point/ distribution panel /feeder pillar etc as directed including necessary earth work, concrete pit with PCC (1:3:6) type C1, pre cast RCC(1:1:5:3) type A1 cover slab duly reinforced with 8 mm dia TMT bar 150mm c/c both way and two numbers lifting handle made of TMT bar and set in cement mortar (1:4), funnel, wire mesh, all as shown in electrical plate No 5 of SSR part-1 and testing on completion including taking out old earthing complete.
All as per item No 52 here-in-before but connected to GI strip of size 32x6 mm earthing lead in lieu of 4.00 mm dia wire and protected by and including 40 mm dia GI pipe .
Supply and fix GI wire of 4mm dia as earth continuity conductor including taking down old unserviceable earth wire compleate all as specified and as directed.
Supply and fix galvanised iron pipe in 15 mm bore, light grade for protection of GI Wire, laid in floor/road crossing, fixing to pole with MS clamp,nut, bolt etc including taking down old unserviceable one complete all as directed. Make:- Prakash / Utkarsh Tubes Ltd / Jindal / Zenith / Bansal / Nezone / M/S BST Infratech Ltd. Note:- MS clamps shall be measured and paid seperatly .
Supply and fix in replacement of old unserviceable changeover switches of capacity 200 A and 4 pole complete all as directed and specified. Make:Cat No:IHCNFE0200 of Havell's or Indoasian cat No. ITAS0200 or Legrand/C&S / HPL / Standard / L&T).
Supply and fix in replacement of old unserviceable changeover switches of capacity 100 A and 4 pole complete all as directed and specified. Make:Cat No:IHCNFE0100 of Havell's or Indoasian cat No. ITAS0100 or Legrand / C&S / HPL / L&T / Standard).
Supply and fix in replacement of old unserviceable changeover switches of capacity 63 A and 4 pole complete all as directed and specified. Make:Cat No:IHCNFE063 of Havell's or Indoasian cat No. ITAS0063 or Legrand/C&S / HPL / L&T / Standard)).
Supply and fix 4 way vertical type TPN DB in double door suitable for triple pole MCCB as incomer but without MCB including making good of damaged surface/wall including re-connection with existing earth wire to DB including taking out old unserviceable DB all as specified and as directed. Make: Havells Cat No. DHDLVDRWGOFO04/ equivallent model of L&T/ Indoasian / C&S / HPL / Standard) )
Supply and fix in replacement of old unserviceable aluminium busbar chamber/Junction box of capacity 32 A and 4 pole complete all as directed and specified. Make: Havells / L&T/ Indoasian / HPL / Standard / C&S
Supply and fix in replacement of old unserviceable aluminium busbar chamber/Junction box of capacity 63 A and 4 pole complete all as directed and specified. Make: Havells / L&T/ Indoasian / HPL / Standard / C&S
Supply and fix in replacement of old unserviceable aluminium busbar chamber/Junction box of capacity 100 A and 4 pole complete all as directed and specified. Make: Havells / L&T/ Indoasian / HPL / Standard / C&S
Supply and fix in replacement of old unserviceable aluminium busbar chamber/Junction box of capacity 200 A and 4 pole complete all as directed and specified. Make: Havells / L&T/ Indoasian / HPL / Standard / C&S
M/L for MS clamps, made out of FI, of adequate size and thickness, bend to shape as requited, drilling, bolting, etc complete, for fixing as in gi pipe, cables and the like, including preparing new steel and iron surfaces and applying two coats of synthetic enamel paint over a coat of primer, etc complete.
All as per item No. 04 here-in before but cable of size 2 core 16 sqmm.
Drilling/ Boring of Road for laying of UG Cable/ Protection pipe of various sizes not exceeding 50 cm in depth complete all as specified and as dircted.
supply and fix straight hot shrink cable joint kit for LT ug cable of size 50 sqmm 3.5 core including excavatin of earth at undergruond cable fault position and making good surface at the fault position complete all as specified and as directed
supply and fix straight hot shrink cable joint kit for LT ug cable of size 35/25/16 sqmm 3.5/4 core including excavatin of earth at undergruond cable fault position and making good surface at the fault position complete all as specified and as directed. Make fpr item Nos. 68 & 69:- Rachem / Denson / 3M
Material and labour for sub-main wiring (surface type) with two run of PVC insulated, unsheathed, single core, multistranded copper conductors of size 6.0 Sq mm and one run of 6.0 Sqmm copper conductor as continuity earth wire, drawn through and including PVC casing caping including taking down old sub main wiring with casing caping all as specified and as directed. Note:Three run of 6.0sqmm copper conductor+One run run Cassing-N-capping shall measured as one unit i.e RM
Material and labour for sub-main wiring (Surface type) with two run of PVC insulated, unsheathed, single core, multistranded copper conductors of size 4.0 Sq mm and one run of 4.0 Sqmm copper conductor as continuity earth wire, drawn through and including PVC casing capping of adequate size with fittings and accessories as required at site and taking down old sub main wiring with casing caping complete all as specified and as directed. Note:- (i):Three run of 4.0sqmm copper conductor+One run PVC casing capping shall measured as one unit i.e RM. Make for item Nos. 69 & 70:- Cable:- Polycab / Finolex / Havells / / KEI / HPL / Mescab / Standard / RR Kabel. Casing - N- Caping:- Plaza / Presto Plast / Precision / M/S AGK Industries.
Supply and fix of 4 way vertical type TPN DB in double door suitable for four pole MCCB as incomer including make good of damaged surface/wall including re-connection with existing earth wire to DB incuding taking out the old unserviceable one complete all as specified and as directed.Note:- MCCB shall be measured and paid seperatly. Make: Havells Cat No. DHDLVDRWGOFO04/ LTVD04N of L&T/ INDOASIAN Cat No. 811870.
Supply and fix MCCB four pole 63 amps, 240 volts, 16 KA, with all incoming / outgoing connections suitable for fix 4 way vertical type TPN DB in double door twith proper size of aluminium lugs complete all as specified as directed Make: Havells Cat No. IHLGNF0063 / INDOASIAN Cat No. 830006/ equivalent in C&S / HPL / L&T / Standard / Legrand.
Supply and fix MCB triple pole & neutral 63 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections suitable for 4 way type TPN DB in double door (itrm no 36) with proper size of aluminium lugs complete all as specified as directed . Make Havells Cat No. DHMGCTNF063/ INDOASIAN Cat No. 811220/ equivalent in C&S / HPL / L&T / Standard / Legrand.
Supply and fix in repair, MCB triple pole & neutral 63 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections suitable for 4 way type TPN DB in double door (itrm no 36) twith proper size of aluminium lugs complete all as specified as directed . Make Havells Cat No. DHMGCTNF063/ INDOASIAN Cat No. 811220/ quivalent in C&S / HPL / L&T / Standard / Legrand.
Supply and fix MCB single pole & neutral 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified as directed
Supply and fix MCB single pole 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified as directed. Note for item Nos. 75 & 76:(i) Cost of alluminium lugs shall be included in the unit rate. Make for item Nos. 75 & 76 : Havells / L&T / Indoasian / HPL / Standard / C&S / Legrand.
Supplying, fixing, connection and testing MCCB, 4 pole, 100 Amp capacity, 16/18/25 KA rupturing capacity, AC 415 volts with fixed thermal and magnetic settings including taking down old unserviceable MCCB complete all as specified and directed.. (Make: Havells Cat part No IHLGNF 0100 / L&TCat part No CM 9051800 KO / C&S Cat Part No- CSC2N4 100)
Supplying, fixing, connection and testing MCCB, 4 pole, 200 Amp capacity, 16/18/25 KA rupturing capacity, AC 415 volts with fixed thermal and magnetic settings including taking down old unserviceable MCCB complete all as specified and directed.. (Make: Havells cat no.IHLLSEBF0200/ INDOASIAN Cat part No 830116 / C&S Cat Part No- CSC4S4 200)
All as per item No.78 above but 320/ 315 Amp and rupturing capacity 36 KA. (Make:Havells cat no.IHLLSEBF0320/ INDOASIAN Cat part No 830175/C&S ).
Servicing, commissioning and testing of LT panel including replacement of burnt out lugs, scraping the bus bar chamber with ewary paper, cleaning the bus bar panel with CTC, remove the burnt out electrical wiring and replacement of bolt, nuts, washer and new wiring for metering eqpt, phase sequence RYB with bus bar insulation tapes, heating with blower, reconnecting, testing and commissioning. Note:- Cost of Nuts, bolts, washers, insulation tapes, wiring & other connecting items shall be included in unit rate.
M/S H.P Singha
ROY CONSTRUCTION
BHASKAR SUPPLY AGENCY
RBS Builders
Shree Mahabir Builders
NANDYENTERPRISES
The Planters Engineering Corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .