Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹1.7 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹1.7 Cr+₹1.3 L (0.80%)Rejected-Finance 2ND FLOOR 9 EZRA STREET KOLKATA WEST BENGAL 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹1.7 Cr+₹1.3 L (0.80%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹1.8 Cr+₹9.3 L (5.52%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹1.8 Cr+₹9.3 L (5.52%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹1.9 Cr+₹22.4 L (13.3%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹1.9 Cr+₹22.4 L (13.3%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹1.9 Cr+₹25.2 L (14.9%)Rejected-Finance HENGRABAI LICHUBAGAN BYE LANE 2 HOUSE NO 2 GUWAHATI 781036 ASSAM | KAMRUP METRO | ASSAM | 781036 | ₹1.9 Cr+₹25.2 L (14.9%) | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | S and B Electricals L5 | PURBANCHAL BUILDERS L3 | surendra infrastructure pvt ltd L2 | GEPS PROJECTS L4 | OM SAI POWER SYSTEMS L7 | SAGGI ELECTRIC COMPANY L1 | DURGAI ELECTRICALS L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for fabrication and installation of 33 KV bracing support to mount electrical equipments of Sub Stn and Grid Structure/Tower for stringing of 33 KV over head Bus /ACSR Conductor to form a bus bar inside Sub Station with Hot dip Galvanised Lattice type Steel Structure, main structural members and bracings system, supports, clamps & back plates etc. of any size, any design fabricated from structural steel sections including GI nuts, bolts, washers welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed, complete all as specified and as directed.
Note : Civil work for foundation for Tower/Bracing Support is included under qoted rate of this item. | 40 | Qtl | 20,000 ₹8,00,000 | 32,999 ₹13,19,960 | 13,850 ₹5,54,000 Lowest | 60,000 ₹24,00,000 | 21,000 ₹8,40,000 | 18,150 ₹7,26,000 | 18,850 ₹7,54,000 |
| 2.00 | Supply, fixing, testing and commissioning Air Break Isolating rotating type switch of rating 400 Amps outdoor horizontal mounting type suitable for manual operation from ground level, tripple pole, double break consisting hot dip galvanised steel channel base having 3x2 Nos 33 KV post top insulator per phase complete with copper contact element, MS flat, copper blade, bearing assembly etc. and suitable size of GI pipe as down rod lever between coupling bar and operation handle with locking arrangement at both "ON" and "OFF" position suitable for 33 KV system having earth link system comprising earth switch indicator and auxilary switch, complete all as specified and as directed. | 1 | Each Set | 75,000 ₹75,000 | 79,999 ₹79,999 | 82,500 ₹82,500 | 1,50,000 ₹1,50,000 | 80,000 ₹80,000 | 57,750 ₹57,750 Lowest | 70,000 ₹70,000 |
| 3.00 | Supply, fixing,testing and commissioning Air Break Isolating rotating type switch of rating 200 Amps outdoor horizontal mounting type suitable for manual operation from ground level, tripple pole, double break consisting hot dip galvanised steel channel base having 3x2 Nos 33 KV post top insulator per phase complete with copper contact element, MS flat, copper blade, bearing assembly etc and suitable size of GI pipe as down rod lever between coupling bar and operation handle with locking arrangement at both "ON" and "OFF" position suitable for 33 KV system, complete all as specified and as directed. | 2 | Each Set | 70,000 ₹1,40,000 | 6,999 ₹13,998 Lowest | 79,950 ₹1,59,900 | 1,50,000 ₹3,00,000 | 85,000 ₹1,70,000 | 57,750 ₹1,15,500 | 80,000 ₹1,60,000 |
| 4.00 | Supply, installation, testing and commissioning Outdoor Type Porcelain Clad , Structure mounted Outdoor VCB (Vaccum Circuit Breaker) manual and motorised spring charged, 33 KV, 3-Phase, 50 C/S, Rated normal current minimum 400 Amp, Breaking Capacity - 31.5 KA for 3 Sec, Making Capacity- 62.5 KA, Insulation level-36 KV/70 KV/170 KV(P),Min Creepage distance-900 mm, DC Aux voltage-110 Volts, along with single ACSR terminal connector per phase totally enclosed metal clad, manual charged independent spring closed/ spring tripping, trip free operating mechanism with manual closing and tripping push button, mechanical indication viz Breaker closed/open, spring charged/discharged mechanical counter, electrical release coilbreaker operating auxiliary switch with minimum 6 NO+6 NC and spare contacts and motorised mechanism plus manual hand operated mechanism. Circuit breaker shall have an arc protection mechanism for all compartments. The switch gear panel shall be sheet metal enclosure of minimum 2 mm thickness and shall be constructed as dust, weather and vermin proof housing with minimum protection of IP54 as defined in IEC 60529. The Panel shall be electrically operated trip free with mechanical ON/OFF indicators and spring charged motor shunt tripping and closing coil including power pack input supply 230 V & 110 V AC from PT and output of 24V DC. The DC supply shall be from the power pack. The input to the power pack is 110V from PT and 230 V from the main supply. The power pack shall be capable for minimum 3 tripping even input to the power pack is failed. The switch gear shall be conforming to IEC 62271-100 / 200 complete all as per technical specifications given in PS and including of following accessories as specified and directed.
(a) Normal System voltage 33 KV and highest voltage 36 KV.
(b) Rated short circuit breaking current (rms) 31.5 KA and rated short circuit making current (peak) 63 KA.
(c) Master trip and supervision relay.
(d) Rated supply voltage for trip close coil 24 V DC
(e) Minimum number of auxiliary contacts provided 13 | 1 | Each | 5,00,000 ₹5,00,000 | 8,99,999 ₹8,99,999 | 4,17,500 ₹4,17,500 Lowest | 4,80,000 ₹4,80,000 | 11,00,000 ₹11,00,000 | 4,95,000 ₹4,95,000 | 9,77,500 ₹9,77,500 |
| 4.10Srl Item No. 4.00 (Contd...) (f) Spring charging time < 15 Sec (g) Space heater (h) Indicating Lamp (j) Ilumination LED lamp NOTE :- (i) Design / Drawing of the HT VCB showing all components along with the dimensions is to be obtained from the OEM, to get vetted from CWE before placing final order to the manufacturer and cost for the same is deemed to be included in the quoted rates. (ii) Necessary PCC foundation etc. shall be as per the recommendations of OEM and cost of the same is deemed to be included in the quoted rates. (iii) The cost of Primary / Secondary Injection tests, Calibration etc. during commissioning and in the complete defect liability period as and when required is deemed to be included in the quoted rates. (iv) Anything missed out in the technical specifications but technically required for efficient working of the system is deemed to be included in the quoted rates. (v) The quoted rate shall be deemed to be inclusive of the factory inspection to be carried out by authorised rep of Accepting Officer before dispatch and Pre-commissioning Inspection by SEI on ground. | ||||||||||
| 5.00 | Supply, fixing, connecting, testing & commissioning Current transformer (CT) 33 KV, outdoor type, Single Pole and oil cooled of ratio 100-50/5-5 Amps, class 1.0 / 5P10, burden 15 VA with accuracy class 1.0 for metering equipment of VCB, overcurrent and earth fault protection and class 5 P 10 for protection, CTs chamber mounted on and including CT junction box bearing specification as per IS, complete all as specified and as directed. | 1 | Set of Three | 3,50,000 ₹3,50,000 | 3,39,999 ₹3,39,999 | 4,80,000 ₹4,80,000 | 3,60,000 ₹3,60,000 | 2,45,000 ₹2,45,000 Lowest | 3,13,500 ₹3,13,500 | 2,55,000 ₹2,55,000 |
| 6.00 | Supply, fixing, connecting, testing & commissioning Potential transformer of ratio 33 KV/√3/110 V/√3/110V/√3, class of insulation- class A, accuracy class core I - 0.5, core II-3P, 50 Hz outdoor type, single phase PT oil immersed and self cooled type having Burden core I - 100 VA, core II -100 VA , suitable for metering equipment of VCB installed on and including MS channel/angle iron pedestal type bearing specification as per IS, complete all as specified and as directed. | 1 | Set of Three | 4,00,000 ₹4,00,000 | 3,39,999 ₹3,39,999 | 4,85,000 ₹4,85,000 | 3,60,000 ₹3,60,000 | 2,45,000 ₹2,45,000 Lowest | 3,13,500 ₹3,13,500 | 2,50,000 ₹2,50,000 |
| 7.00 | Supply and fix lightning arresters suitable for 33000 Volts expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps, with surge monitor and base type mounted on steel structure, complete all as specified and as directed. | 1 | Set of Three | 30,000 ₹30,000 | 59,999 ₹59,999 | 17,000 ₹17,000 Lowest | 2,40,000 ₹2,40,000 | 30,000 ₹30,000 | 31,350 ₹31,350 | 39,000 ₹39,000 |
| 8.00 | Material and labour for Aluminium Conductor Steel Reinforced (ACSR) conductor of size wolf or nearest suitable size as directed on steel pole/structure for connecting 33 KV equipment / 33 KV distribution system with necessary connection with PG clamp including flat pad, extension terminal and jumpers of suitable size complete on 33 KV over head bus bar, complete all as specified and directed. | 2 | Qtl | 40,000 ₹80,000 | 33,999 ₹67,998 | 49,500 ₹99,000 | 45,000 ₹90,000 | 35,000 ₹70,000 | 21,450 ₹42,900 Lowest | 25,000 ₹50,000 |
| 9.00 | Supply, Installation, testing & commissioning of Step down Power Transformer of capacity 5.0 MVA (5000 KVA) outdoor type 33/11 KV floor/platform mounting, 3 phase, 50 HZ,oil immersed with 'ONAN' type cooling with external cooling tubes/radiators, Delta/star connected, vector group DYN-11 double copper wound with auto mannual type on load tap changer (OLTC) with automatic Voltage Regulator (AVR) in 16 Steps each of 1.25 % /17 positions on HV side to take care of voltage from +5% to -15% to give output on 11 KV secondary side. The transformer should have cable box on LV side, marshalling box having TTB, oil temprature gauge, winding temperature indicator, dehydrating breather with first fill of dehydrating agent, oil upto recommended level including oil conservator tank, explosion vent, rating and terminal marking plate, oil level gauge, oil drain and filter valve, providing independent earthings point and neutral fittings, lugs complete in all respect and all other standard accessories required as per latest IS specification, gauges, bearing specification as per IS-2026 and accessories complete including S&F and commissioning of indoor control panel for OLTC, all as per technical specifications given in PS and all as specified comprising with the followings:-
(i) 01 No cable end box on LV side
(ii) Marshalling box with TTB
(iii) Oil conservator with filter type drain valve and oil level guage.
(iv) Dehydrating breather with first filling of Dehydration agent.
(v) Explosive vent 01 nos.
(vi) Thermometer pocket 01 nos.
(vii) Two Earthing terminal on tank body to facilitate fixing of 32x6 mm strips.
(viii) Removable manual crank handle to operate OLTC 01 nos
(ix) Oil filling cum filter valve with plug 01 nos.
(x) Oil level indicator (flush tube) 01nos.
(xi) Oil draining filter valve with plug 01nos.
(xii) Conservator with oil filling hole 01nos. | 1 | Each Job | 1,10,00,000 ₹1,10,00,000 | 93,99,999 ₹93,99,999 | 92,49,500 ₹92,49,500 | 84,00,000 ₹84,00,000 Lowest | 1,22,00,000 ₹1,22,00,000 | 99,82,500 ₹99,82,500 | 1,16,04,920 ₹1,16,04,920 |
Tender Value
₹2.2 Cr
EMD Value
₹3.0 L
Closing Date
2 Feb 2026, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVN OF STAND BY TRANSFORMER AT AFS PANAGARH
2026_MES_747182_1
88879/B/PAN/E8
Open Tender
Civil Works
Item Rate
180 days
Panagarh
As per tender documents
8 documents required · 8 mandatory
₹2,000
GE (P) (AF) Panagarh
₹3.0 L
Yes
30 Mar 2026
5 Jan 2026
4 Feb 2026
5 Jan 2026
2 Feb 2026
26 Jan 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for fabrication and installation of 33 KV bracing support to mount electrical equipments of Sub Stn and Grid Structure/Tower for stringing of 33 KV over head Bus /ACSR Conductor to form a bus bar inside Sub Station with Hot dip Galvanised Lattice type Steel Structure, main structural members and bracings system, supports, clamps & back plates etc. of any size, any design fabricated from structural steel sections including GI nuts, bolts, washers welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed, complete all as specified and as directed.
Note : Civil work for foundation for Tower/Bracing Support is included under qoted rate of this item. | 40 | Qtl | - | - |
| 2 | Supply, fixing, testing and commissioning Air Break Isolating rotating type switch of rating 400 Amps outdoor horizontal mounting type suitable for manual operation from ground level, tripple pole, double break consisting hot dip galvanised steel channel base having 3x2 Nos 33 KV post top insulator per phase complete with copper contact element, MS flat, copper blade, bearing assembly etc. and suitable size of GI pipe as down rod lever between coupling bar and operation handle with locking arrangement at both "ON" and "OFF" position suitable for 33 KV system having earth link system comprising earth switch indicator and auxilary switch, complete all as specified and as directed. | 1 | Each Set | - | - |
| 3 | Supply, fixing,testing and commissioning Air Break Isolating rotating type switch of rating 200 Amps outdoor horizontal mounting type suitable for manual operation from ground level, tripple pole, double break consisting hot dip galvanised steel channel base having 3x2 Nos 33 KV post top insulator per phase complete with copper contact element, MS flat, copper blade, bearing assembly etc and suitable size of GI pipe as down rod lever between coupling bar and operation handle with locking arrangement at both "ON" and "OFF" position suitable for 33 KV system, complete all as specified and as directed. | 2 | Each Set | - | - |
| 4 | Supply, installation, testing and commissioning Outdoor Type Porcelain Clad , Structure mounted Outdoor VCB (Vaccum Circuit Breaker) manual and motorised spring charged, 33 KV, 3-Phase, 50 C/S, Rated normal current minimum 400 Amp, Breaking Capacity - 31.5 KA for 3 Sec, Making Capacity- 62.5 KA, Insulation level-36 KV/70 KV/170 KV(P),Min Creepage distance-900 mm, DC Aux voltage-110 Volts, along with single ACSR terminal connector per phase totally enclosed metal clad, manual charged independent spring closed/ spring tripping, trip free operating mechanism with manual closing and tripping push button, mechanical indication viz Breaker closed/open, spring charged/discharged mechanical counter, electrical release coilbreaker operating auxiliary switch with minimum 6 NO+6 NC and spare contacts and motorised mechanism plus manual hand operated mechanism. Circuit breaker shall have an arc protection mechanism for all compartments. The switch gear panel shall be sheet metal enclosure of minimum 2 mm thickness and shall be constructed as dust, weather and vermin proof housing with minimum protection of IP54 as defined in IEC 60529. The Panel shall be electrically operated trip free with mechanical ON/OFF indicators and spring charged motor shunt tripping and closing coil including power pack input supply 230 V & 110 V AC from PT and output of 24V DC. The DC supply shall be from the power pack. The input to the power pack is 110V from PT and 230 V from the main supply. The power pack shall be capable for minimum 3 tripping even input to the power pack is failed. The switch gear shall be conforming to IEC 62271-100 / 200 complete all as per technical specifications given in PS and including of following accessories as specified and directed.
(a) Normal System voltage 33 KV and highest voltage 36 KV.
(b) Rated short circuit breaking current (rms) 31.5 KA and rated short circuit making current (peak) 63 KA.
(c) Master trip and supervision relay.
(d) Rated supply voltage for trip close coil 24 V DC
(e) Minimum number of auxiliary contacts provided 13 | 1 | Each | - | - |
| 4.1 | Srl Item No. 4.00 (Contd...)
(f) Spring charging time < 15 Sec
(g) Space heater
(h) Indicating Lamp
(j) Ilumination LED lamp
NOTE :-
(i) Design / Drawing of the HT VCB showing all components along with the dimensions is to be obtained from the OEM, to get vetted from CWE before placing final order to the manufacturer and cost for the same is deemed to be included in the quoted rates.
(ii) Necessary PCC foundation etc. shall be as per the recommendations of OEM and cost of the same is deemed to be included in the quoted rates.
(iii) The cost of Primary / Secondary Injection tests, Calibration etc. during commissioning and in the complete defect liability period as and when required is deemed to be included in the quoted rates.
(iv) Anything missed out in the technical specifications but technically required for efficient working of the system is deemed to be included in the quoted rates.
(v) The quoted rate shall be deemed to be inclusive of the factory inspection to be carried out by authorised rep of Accepting Officer before dispatch and Pre-commissioning Inspection by SEI on ground. | - | - | - | - |
| 5 | Supply, fixing, connecting, testing & commissioning Current transformer (CT) 33 KV, outdoor type, Single Pole and oil cooled of ratio 100-50/5-5 Amps, class 1.0 / 5P10, burden 15 VA with accuracy class 1.0 for metering equipment of VCB, overcurrent and earth fault protection and class 5 P 10 for protection, CTs chamber mounted on and including CT junction box bearing specification as per IS, complete all as specified and as directed. | 1 | Set of Three | - | - |
| 6 | Supply, fixing, connecting, testing & commissioning Potential transformer of ratio 33 KV/√3/110 V/√3/110V/√3, class of insulation- class A, accuracy class core I - 0.5, core II-3P, 50 Hz outdoor type, single phase PT oil immersed and self cooled type having Burden core I - 100 VA, core II -100 VA , suitable for metering equipment of VCB installed on and including MS channel/angle iron pedestal type bearing specification as per IS, complete all as specified and as directed. | 1 | Set of Three | - | - |
| 7 | Supply and fix lightning arresters suitable for 33000 Volts expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps, with surge monitor and base type mounted on steel structure, complete all as specified and as directed. | 1 | Set of Three | - | - |
| 8 | Material and labour for Aluminium Conductor Steel Reinforced (ACSR) conductor of size wolf or nearest suitable size as directed on steel pole/structure for connecting 33 KV equipment / 33 KV distribution system with necessary connection with PG clamp including flat pad, extension terminal and jumpers of suitable size complete on 33 KV over head bus bar, complete all as specified and directed. | 2 | Qtl | - | - |
| 9 | Supply, Installation, testing & commissioning of Step down Power Transformer of capacity 5.0 MVA (5000 KVA) outdoor type 33/11 KV floor/platform mounting, 3 phase, 50 HZ,oil immersed with 'ONAN' type cooling with external cooling tubes/radiators, Delta/star connected, vector group DYN-11 double copper wound with auto mannual type on load tap changer (OLTC) with automatic Voltage Regulator (AVR) in 16 Steps each of 1.25 % /17 positions on HV side to take care of voltage from +5% to -15% to give output on 11 KV secondary side. The transformer should have cable box on LV side, marshalling box having TTB, oil temprature gauge, winding temperature indicator, dehydrating breather with first fill of dehydrating agent, oil upto recommended level including oil conservator tank, explosion vent, rating and terminal marking plate, oil level gauge, oil drain and filter valve, providing independent earthings point and neutral fittings, lugs complete in all respect and all other standard accessories required as per latest IS specification, gauges, bearing specification as per IS-2026 and accessories complete including S&F and commissioning of indoor control panel for OLTC, all as per technical specifications given in PS and all as specified comprising with the followings:-
(i) 01 No cable end box on LV side
(ii) Marshalling box with TTB
(iii) Oil conservator with filter type drain valve and oil level guage.
(iv) Dehydrating breather with first filling of Dehydration agent.
(v) Explosive vent 01 nos.
(vi) Thermometer pocket 01 nos.
(vii) Two Earthing terminal on tank body to facilitate fixing of 32x6 mm strips.
(viii) Removable manual crank handle to operate OLTC 01 nos
(ix) Oil filling cum filter valve with plug 01 nos.
(x) Oil level indicator (flush tube) 01nos.
(xi) Oil draining filter valve with plug 01nos.
(xii) Conservator with oil filling hole 01nos. | 1 | Each Job | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tendernotice_2.pdf
PDF • 0.31 MB
BOQ_836713.xls
BOQ • 0.42 MB
Tender.pdf
Tender Documents • 1.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .