| 1 | L1₹6.6 LAccepted-AOC STREET NO 10 MALLOMAZRA ROAD BHAKHRA ENCLAVE PATIALA PB | PATIALA | PUNJAB | 140401 | L1 | Accepted-AOC Being Lowest bidder | |
| 2 | L2₹7.3 L+₹16,702 (2.36%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹8.1 L+₹99,548 (14.0%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹9.0 L+₹1.9 L (27.0%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹9.1 L+₹2.0 L (28.1%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
9 Aug 2021, 6:00 pmClosed
Sh Himanshu
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2021_MES_459061_1
GE(S)/PAT-18/S/2021-22
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Sangrur
Refer tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (S) Patiala
₹36,000
Yes
19 Aug 2021
12 Jul 2021
11 Aug 2021
12 Jul 2021
9 Aug 2021
26 Jul 2021
12 Jul 2021 - 19 Jul 2021
Amount
Taking down carefully copper/ aluminium point wiring (light fan socket or power) complete along with fittings such as switches, ceiling roses, Pendants, regulators, Tube fittings and other fittings/conduit from surface /wall . Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location. (Note :- Serviceable fitting / fixtures will be reused in the work as directed by Engineer- in-Charge)
Taking down un-serviceable main switch, DB’s, DB for MCB etc of any type and any capacity including making good the disturbed surface and matching the colour of wall with the existing colour wash / paint / distemper wherever required (as per the existing ) all as directed by Engineer-in-Charge.
Taking down ceiling fan of any descriptions, servicing and repairs of fans as required, fixing back, connecting and testing the fan for its satisfactory function all as directed by Engineer-in-Charge.
Taking down exhasust fan of any descriptions, servcing and repairs of fans as required, fixing back, connecting and testing the fan for its satisfactory function all as directed by Engineer-in-Charge.
Taking down elect water heater of any descriptions, servcing and repairs of geyser as required, fixing back, connecting and testing the geyser for its satisfactory function all as directed by Engineer-in-Charge.
M & L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit of suitable size (not less than 20 mm) on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified, for the following :-
(a) One light/fan point controlled by one 1-way switch
(b) One light point controlled by two 2-way switch
(c) One 3/5 pin socket outlet, 5 Amp on independent board
(d) One 3/5 pin socket outlet, 5 Amp on same board
(e) One bell /buzzer point controlled by one push button on independent board
M&L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified and directed by Engineer in Charge.
Dismantling/Taking down existing unserviceable sub main wiring from batten / conduit of any size all as directed. Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location.
M &L for sub main surface wiring with PVC insulated unsheathed copper conductor cable of size 6 Sqmm single core through concealed rigid nonmetallic PVC conduit of suitable size (Not less than 25 mm dia) in wall and surface of ceiling including 6 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly including making good the disturbed potion of wall. (Note :- Two run of 6 Sqmm copper cable one run of 6 Sqmm copper cable and PVC conduit will be measured as a single length)
Switch Modular type, 6 Amp, 240 Volts , one way complete all as specified.
Switch Modular type, 6 Amp, 240 Volts , Two way complete all as specified.
Switch Modular type, 16 Amp,240 Volts , one way complete all as specified.
Socket outlet, Modular type, 6 Amp complete all as specified.
Socket outlet, Modular type, 6 &16 Amp complete all as specified.
Bell Push, Modular type, 6 Amp complete all as specified.
Fan regulator, modular type electronic step type complete all as specified.
S&F ceiling rose surface bakelite two to three terminal 65x50 mm.
S&F in replacement Tube light fittings LED type 1x20 Watt 4 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable all as specified & directed.
S&F in replacement Tube light fittings LED type 1X10 Watt, 2 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable all as specified & directed.
Supply & fix LED bulk head ,10 W complete all as specified & directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as directed.
S&F LED Bulb 9 watt 230 volt retrofit type complete all as directed.
S&F in bell ding dong operating on AC 230 volt single phase.
S&F MCB DB SPN 4 Way with acrylic double door complete all as specified and directed.
S&F MCB DB SPN 8 Way with acrylic double door complete all as specified and directed.
S&F including flushing in wall MCB distribution board vertical TPN 4 way 415 Volts AC double door type sheet steel phosphotised powder painted with bus bar neutral earth bar including provision of MCB TPN, FP 100 Amp conforing to IP 43 as incomer all as complete specified and directed.
S&F MCCB 4 pole 63 Amp 415 volt with breaking capacity of 16 KA complete all as specified and direceted.
S&F MCCB 4 pole 100 Amp 415 volt with breaking capacity of 16 KA complete all as specified and direceted.
S&F MCB SPN 240V 40 Amps C series 10 KA complete all as specified and direceted.
S&F MCB SP 240V 6 to 32 Amps C series 10 KA complete all as specified and direceted.
Taking Down the KWH meter along with wooden board/DB after removing all electrical connection complete all as directed by Engineer in Charge.
Refixing & connecting the same or new serviceable KWH energy meter after wiring complete all as directed by Engineer in Charge.
S&F Sheet metal enclosure factory made of size 20cm x 25cm x 12.5 cm deep box made out of 2mm thick ms sheet with double door with locking arrangement , epoxy power coated holes drilled for cable entries suitable for accomodating electric energy meter including brick/cement works as per site requirement includiing flushing the box in walll and making good the disturbed portion of wall /surface complete all as specified & directed bby Engr in charge.
Taking down old U/S LT UG cable of any size from trenches/ pipe/ floor/ walls complete all as specified.
Supply laying jointing aluminium service cable 10 sqmm 2 core fixing on wall/ducts etc including necessary fixing arrangement such as cable lugs glands etc complete after removing/ taking out extg unsv cable to the entire satisfaction of Engr in Charge.
Supply laying jointing cable XLPE insulated PVC shetahted strip wire armoured 1100 volt 4 core 25 sqmm multi stranded aluminium conductor laid in trenches/ wall/ ducts etc including necessary fixing arrangement such as cable lugs glands etc complete after removing/ taking out extg unsv cable to the entire satisfaction of Engr in Charge.
Excavation in trenches n.exc 1.5 mtr deep and n.exc 1.5 mtr wide getting out in soft/losse soil.
Returning filling in including spreading leveling, watering and well ramming in layers
Removing excavated soil to a distance not exc. 50 mtr and depositing where directed
Supply and spreading dry sand in trenches for cushioning of cable
Taking out Bricks from trenches complete all as specified & directed
Laying only old serviceable bricks obtained from item Sl no 46 above
Supply and laying well brunt bricks sub class ‘B’ old size for cable protection.
S&F GI Tube light grade 40 mm dia as in cable protection pipe complete all as specified & directed by Engr in charge.
M & L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2 mtr deep below ground level with top edge of the plate not less than 1.4 mtr below normal ground level , connected earth wire 4 sqmm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit in PCC(1:3:6) type C-1 cast iron frame 50mm thick pre cast RCC(1: 1 1/2:3) nominal mix cover slab reinforced with 8 mm dia mild steel deformed bar 15cc and suitable handle of 10 mm Dia round bar including necesary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc 50m and funnel with watering pipe wire mesh copper lugs etc GI protection pipe of size 15 mm bore including testing complete all as specified & directed by Engr in Charge.
S&F Modular white cover plate with frame 1 module complete all as specified & directed by Engr in Charge.
S&F Modular white cover plate with frame 2 module complete all as specified & directed by Engr in Charge.
S&F Modular white cover plate with frame 3 module complete all as specified & directed by Engr in Charge.
S&F Modular white cover plate with frame 4 module complete all as specified & directed by Engr in Charge.
S&F Modular white cover plate with frame 8 module complete all as specified & directed by Engr in Charge.
S&F Modular metal flush box 1,2 module complete all as specified & directed by Engr in Charge.
S&F Modular metal flush box 3 module complete all as specified & directed by Engr in Charge.
S&F Modular metal flush box 4 module complete all as specified & directed by Engr in Charge.
S&F Modular metal flush box 8 module complete all as specified & directed by Engr in Charge.
S&F Modular white blank plate complete all as specified & directed by Engr in Charge.
R D Bansal
R N Enterprises
NARINDER KUMAR SONS
m/s s.n. builders
M/s SHIVA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .