Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC ROOM NO D 297 PART III GANESH MURTI NAGAR CUFF PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC Lowest Amount | |
| 2 | L2₹32.2 L+₹2.2 L (7.31%)Rejected-Finance NOT AVAILABLE | L2 | Rejected-Finance Not Reasonable | |
| 3 | L3₹33.4 L+₹3.5 L (11.6%)Rejected-Finance | L3 | Rejected-Finance Not Reasonable | |
| 4 | L4₹37.0 L+₹7.0 L (23.4%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Not Reasonable |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
18 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col N P Singh
GE(WEST) COLABA, MUMBAI
PROVN OF 01 X SHED 12 X14 FT AND 01 ROOM 12 X 14 FT IN TRG AREA AT GRN MAG, SPECIAL REPAIRS TO SEWAGE LINE IN AREA I AND IV IN THE AOR OF AGE BR (W), ADDN / ALTN OF ROOF OF BLDG NO P 27/1 AND CERTAIN REVENUE WORK UNDER GE (W) COLABA, MUMBAI
2021_MES_470060_1
8579/E8
Open Tender
Civil Works
Item Rate
180 days
GE(WEST) COLABA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE(WEST) COLABA
₹86,000
Yes
12 Oct 2021
25 Aug 2021
20 Sept 2021
25 Aug 2021
18 Sept 2021
3 Sept 2021
60 days
Amount
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan and getting out in hard/dense soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth in soft/loose soil for laying cable/GI pipe and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified & directed.
Removing excavated material not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Removing excavated material exceeding 1.5Km but not exceeding 35Km and deposting where directed (usually 25Km from MD land) complete all as specified and directed.
Material and labour for PCC 1:4:8 (Type D2) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Supply and fixing Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of mangalore pattern design any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall / covering of ridge, fixed with self tapping screws complete all as specified and directed.
Supply and fixing of joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lenghts i.e. within 20mm of the length indicated) for purlins & rafters and all other similar works conforming to Fe 410-W (Gde-E-250) quality-A complete all as specified and directed.
Material and labour for preparation of new or previously untreated surfaces and applying two coats of synthetic enamel paint over a coat of primer red oxide, zinc chrome complete all as specified and directed.
Material and labour for brickwork with subclass `B' bricks, straight or curved on plan exceeding 6.00 mtr mean radius, built in cement mortar (1:6) complete all as specified and directed.
Supply and fixing of Factory made 35 mm thick 2nd hard wood plain framed panelled shutters(any panel) with lock rail and panel of 9mm thick B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS :1003(Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
Supply and fixing for 2nd class hard wood plain solid straight chowkhat and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joint complete all as specified and directed.
Supply and fixing 30 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
Material and labour for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 20 mm thick in cement plaster screed bed in CM (1:6) complete all as specified and directed.
Supply and fixing sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with rubber beading in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
Material and labour for PCC (1:3:6) type C1(20 mm graded aggregate) as in bed blocks for hold fast and all other similar works including necesssary formwork complete all as specified and directed.
Supply and fixing mild steel flat iron as in hold fast clamps and all other similar works conforming to Fe 290. Gde -E-165 complete all as specified and directed.
Supply and fixing butt hinges, extruded aluminium, with mild steel hinge pin, bright polished and fixed, type 75 mm size C21 complete all as specified and directed.
Supply and fixing 150 mm long aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
Supply and fixing aluminium anodised 150 mm barrel tower bolts of extruded section complete all as specified and directed.
Supply and fixing 200 mm length aluminium anodised barrel tower bolt extruded section complete all as specified and directed.
Supply and fixing 300mm long aluminium alloy, anodised sliding door bolt with haps, staple(bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
Material and labour for 15 mm thick cement plaster in CM (1:6) on brick work/ RCC wall and finish the surface fair and even without using extra cement complete all as specified and directed.
Material and labour for 20 mm thick in two coats (15mm under coat plus 5mm finishing coat) cement plaster in CM (1:4) on brick work/ RCC wall and finish the surface fair and even without using extra cement complete all as specified and directed.
Material and labour for preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 1mm thick (average) wall putty complete all as specified and directed.
Material and labour for preparation of old surfaces of walls/ceilings/roof by scrapping/rubbing and applying two coat of weather proof acrylic exterior paint (100% acrylic) over one coat of primer complete all as per manfacturers specifications and as directed.
Supply only liquid water proofing compound.
Material and labour for preparation of newly plastered surfaces and applying two coats of 100% exterior grade acrylic paint (wheather proof paint) over one coat of primer complete all as per manfacturers specifications and as directed.
Material and labour for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new or previously untreated wood surfaces of any description not other wise described over 10 cm with or girth complete all as specified and directed.
Material and labour for heavy duty chequered cement concrete tiles 30cm x 30cm x 25mm thick, glossy finished set, jointed and pointed in neat cement slurry over and including 15 mm thick screed bed in cement mortar (1:6) in floors including 25 mm thick PCC (1:2:4) beneth screed bed complete all as specified and directed.
Material and labour for GI frame work for seamless ceiling 600x600mm grid size comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurved web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete all as specified and directed.
Material and labour 8 mm thick Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid (frame work for ceiling shall be measured and paid separately) fixed to aluminum frame work in ceiling and all other similar works complete all as specified and directed.
Disconnecting and dismantling of existing water tanks of exceeding 500 but not exceeding 1000ltrs capacity of any description, shifting and refixing and reconnecting to its original position after completion of water proofing treatment of roof complete all as specified and directed.
Material and labour for minor cleaning work, removal of loose concrete and filling cracks with polymer modified mortar using SmartCare RP or Epoxy Mortar and supplying and applying High performance hybrid polyurea elastomeric waterproofing coating cold applied of spray / brush applied, SmartCare Ultron liquid membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying SmartCare Ultron or approved equivalent in two coats at 1.5 kg per Sqm etc, complete as per Manufacturer specifications. Supplying and applying High performance hybrid polyurea elastomeric waterproofing coating cold applied of spray / brush applied, SmartCare Ultron liquid membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying SmartCare Ultron or approved equivalent in two coats at 1.5 kg per Sqm etc, complete as per Manufacturer specifications over and including padding of cement concrete Type B1, 1:2:4 (20 mm graded stone aggregate) 25 mm thick concrete on RCC roof surfaces and all other similar works complete all as specified and directed (SmartCare Ultron Hybrid Polyurea )
Taking down cement or cement lime plaster on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc any description complete all as specified and directed.
Material and labour for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 3 mm thick (average) wall care putty including rubbing with sand paper complete all as specified and directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises complete all as specified and directed.
Material and labour for non skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Material and labour for preparatin of old painted wooden surfaces of any description not otherwise described over 10cm in width or girth and applying one coat of synthtic enamel paint (up to four storeys) including scaffolding where required for external painting complete all as specified and directed.
Material and labour for cement concrete type B0 (1:2:4) using 12.5 mm graded aggregate, 25 mm thick, as in floor for receiving screed bed complete all as specified and directed.
Material and labour for Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes like tiles etc complete all as specified and directed.
Material and labour for digital coloured glazed ceramic tiles of sizes 300m x 450 mm X 7 mm thick jointed in neat cement slurry, laid over and including 10 mm thick screed bed/backing layer in CM (1:4) and pointed in white or coloured cement to match the shade of tile as in vertical surfaces such as dado/skirting complete all as specified and directed.
Material and labour for for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but nit exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed/bedding layer in CM (1:6) complete all as specified and as directed.
Material and labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
Material and labour for RCC (Nominal Mix) type B0 1:2:4 (12.5 mm graded aggregate) for slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Material and labour for formwork to flat soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed.
Supply and fixing 110 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes laid in trenches complete all as specified and directed.
Supply and fixing in 75mm dia PVC (SWR) grade pipes single socketed in any length with rubber ring joints fixed to walls including fixing clips complete all as specified and directed.
Material and labour for 15mm thick rendering in cement mortar (1:4) inside and outside wall of manhole, other than fair faces of brick work/concrete surface and finishing even and smooth without using extra cement mortar as per manufacturers instructions complete all as specified and directed. Note: (i) WPC shall be measured and paid for separately as 'Supply only'. (ii) WPC to be mixed @200ml per 50 Kg bag of cement all as manufacturers instruction.
Material and labour for PVC (SWR) multi floor trap with grating including jointing with solvent cement for diameter of 75 mm outlet complete all as specified and directed.
Material and labour 20 mm thick granite (of an type and colour) machine cut as in urinal partitions and all other similar works including grinding, polishing, cutting grooves in wall for fixing granite with cement mortar 1:2 and all other arrangments complete all as specified and directed
Supply and fixing 15 mm bore fancy type angular valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. Make:- ESS ESS CROMA Cat Part No C 204 or Equivalent of JAQUAR/PARKO
Supply and fixing PVC connection pipe 15 mm size PTMT nuts of length 450 mm complete all as specified and directed.
Supply and fixing 15 mm bore fancy type bib taps long body cast copper alloy 15mm bore with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. Make:- ESS ESS CROMA Cat Part No C 202 or Equivalent of JAQUAR/PARKO
Supply and fixing in repairs CP Towel Bracket (61 CM) long complete all as specified and directed. Make:- ESS ESS CROMA Cat Part No C 423 or Equivalent of Jaquar/ Parko/ Prayag
Supply and fixing CP soap dish complete all as specified and directed. Make:- ESS ESS CROMA Cat Part No C 414 or Equivalent of JAQUAR/PARKO
Supply and fixing in repair Two piece EWC water closet 655 X 370 x 770 mm including Cistern, Soft Close Seat Cover and Twin Flush Fittings fixed with waste coupling and waste pipe complete all as specified and directed. Make : Cat Part No S1021110 P Trap of Cera or Equivalent in Jaquar / Prayag
Supply and fixing in repair 15 mm bore piller taps cast copper alloy, with capstan heads, chromium plated, screwed down, fancy type high pressure, with or without lettred 'HOT or COLD' with long screwed sunk and fly nuts complete all as specified and directed.
Supply and fixing in repair vitreous China wash basin white, flat back, size 580X450 mm including cutting for pinning in ends of brackets, complete all as specified and directed.
Supply and fixing grating square 150mm size of PTMT(minimum 100 gms) complete all as specified and directed.
Demolition of plain cement concrete of any description and in any position not other wise specifically provided for complete all as specified and directed.
Demolition of brick work or stone / boulder masonry (in portion), built in cement mortar, including all quoins, arches, pillars, etc complete all as specified and directed
Material and labour for PCC (1:2:4) type B0 using 12.5 mm graded stone agreegate as in coping complete all as specified and directed.
Material and labour for 40mm PCC (1:2:4) type B0 (using 12.5 mm graded stone aggregate) for pavement/hard-standing/concrete walls or any other type of repair with synthetic fibre reinforcement (Polypropene), laid in bays or as directed with and including steel formwork to sides of concrete & laid, spread, compacted and finished in a continuous operation including all as specified and directed for finishing surface of concrete toping even and fair (without using extra cement) etc complete all as specified and directed. Make of synthetic fiber : Recron 3S or equivalent Note: Rate quoted shall be inclusive of Synthetic fibre reinforcement @ 125gm per bag of cement.
Supply and fixing welded steel wire fabric, cut to length, fixed to steel members/reinforcement steel, weigh per Sqm not exceeding 4 Kg complete all as specified and directed
Material and labour for forming 20mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ complete all as specified and directed.
Material and labour for fly ash brick work of standard size straight or curved on plan exceeding 6 m mean radius built in CM (1:6) complete all as specified and directed.
Material and labour for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:6) complete all as specified and directed.
Material and labour for rendering 15 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for finishing the drain bottom & side walls even and smooth (without using extra lime or cement) complete all as specified and directed
Supply and fixing 150 mm bore Reinforced concrete pipes, class NP3, laid and jointed complete with collars and complete all as specified and directed.
Supply and fixing 200 mm bore Reinforced concrete pipes, class NP3, laid and jointed complete with collars and complete all as specified and directed.
Material and labour for PCC (1:3:6), type C2 using 40mm graded stone aggregate as in bed to drain pipes of 150mm bore dia including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Material and labour for PCC (1:3:6), type C2 using 40mm graded stone aggregate as in bed to drain pipes of 200mm bore dia including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Material and labour for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and frame and hung as gates including pintle hinges, stops, hand-made sliding bolts etc. conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
Supply and fixing Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles exceeding 5 Kg each complete all as specified and directed.
Material and labour for preparation of new steel surfaces exceeding 10cm width of girth and applying two coats of epoxy paint over a coat of epoxy primer complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demoletion of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Material and labour for RCC(1:2:4), type B1 (using 20 mm or 12.5 mm graded stone aggregate) Precast cement concrete cover slab for manhole and similar article with plain face, set in cement mortar (1:4) complete all as specified and directed.
Supply and fixing deformed or twisted TMT bars 8 mm dia cut to length bent to shape required including cranking binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Material and labour for any coloured digital ultra strong / heavy duty outdoor anti skid vitrified tiles 15-18 mm thick (Square / Rectangular) polished area of each tile exceeding 0.09 Sqm and not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles and including 20 mm thick in cement plaster in CM (1:4) for fixing tiles anywhere complete all as specified and directed.
Material and labour for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-40 Grade, with grey cement and pigment over and including 25mm sand bedding etc complete all as specified and directed.
Excavation and removing/Taking away settled solid/semisolid sludge from Manholes of size 0.60mx0.90m and depth not exceeding 1.5m including pumping out complete water/liquid with provision of temporarily plugging the inlet pipe and diverting the flow into the drain and removing completely the sludge into covered vehicles outside MD land taking precautionary and safety measures complete all as specified and directed.
All as per item no 84 above but manholes of size 0.45X0.60m and depth not exceeding 1.00m complete all as specified and directed.
Supply and fixing 900mm x 600mm FRP manhole cover of 20 ton loading capacity with frame over manhole coping concrete complete all as specified and directed.
Material and labour for Point wiring (concealed type) with 1.5 sq mm, PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including rigid non-metallic PVC heavy duty conduit (ISI mark), 19/ 20 mm dia suitable size including cutting chases for conduits, sinking for concealed boxes and for concealed conduit wiring with all fittings and accessories including with and fix conecaled 1.2 mm thick pressed steel sunken box and fix conecaled 1.2 mm thick pressed steel sunken box and with including lamineted sheet cover for fixing switch socket and unsheathed (FRLSH) single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly and making good to the disturbed surfaces to match the existing surfaces complete (fill up cement in gaps, finishing with putti and apply two coats of paint, match with existing colour in disturbed surface area), as per IS specification and as specified in SSR Part-I complete for one light point / wall fan controlled by one switch, 1 way 6/10 amps, 1 module.
All as per serial no. 87 here-in but for One Exhaust Fan controlled by one switch and regulator.
All as per serial no. 87 here-in but for One 3 pin socket point 5 Amps on independent board.
All as per serial no. 87 here-in but for One 3 pin socket point 5 Amps on same board.
Supply and fixing Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
Supply and fixing socket 2/3 pin 5 Amp complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite 65 x 50 mm two to three terminals complete all as specified and directed.
Supply and fixing 20 watt LED, 4 feet long, with extruded aluminium housing and robust construction LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack. fixed on pvc square for mounting the fittings and electrically connecting with three single core 23/0.0076. PVC insulated multi strandard copper flexible cable from ceiling rose to light fitting (connector block of lamp fitting) and one for earthing complete all as specified and directed. Make : Wipro, Model No Wipro Garnet 20W Aluminium LED batten light 6500K, D560565 / Havells, Model No Higher Wattage 22W LED 6500K / Philips, Model No BS150W LED 20S-6500 PSE OD GR / OSRAM.
Supply and fixing surface mounted 9/10 watts LED tube light fitting, 2 ft long light fitting with extruded aluminium housing and robust construction LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack. fixed on pvc square for mounting the fittings and electrically connecting with three single core 23/0.0076. PVC insulated multi strandard copper flexible cable from ceiling rose to light fitting (connector block of lamp fitting) and one for earthing complete all as specified and directed. Make : Wipro, Model No Wipro Garnet 10W Aluminium LED batten light 6500K, D531065 / Havells, Model No Higher Wattage 10W LED 6500K / Philips, Model No BS150W LED 10S-6500 PSE OD GR / OSRAM.
Supply and fixing sheet metal enclosures, double door, for DBs when MCBs to be used 240 volts 4 way with 200 Amps rated bus bar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed.
Supply and fixing MCB SP, 240 volt, 6 to 32 Amps complete all as specified and directed.
Supply and fixing MCB SPN, 240 volt, 40 Amps complete all as specified and directed.
Supply and fixing Exhaust Fans, AC single phase 230/ 240 V of size 300 mm sweep with louver, including making electrical connections with stranded copper conductor cable of size minimum 0.5 sqmm from ceiling rose to fan connector, necessary clamps, nuts bolts and washers complete all as specified and as directed.
Supply and fixing in repair LED building security light fitting 45 Watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency minium 100 luman per watt after all losses , pressure die-cast aluminium housing LED Street light complete with GI clamp including connected accessories and bracket made of GI Pipe 50mm dia light grade 1.25 m long, bend to shape with two sets of MS flat iron clamps, nuts, bolts, washers etc. complete all as specified and directed. Make Philips : cat pat No BRP409 LED060HENRPC S1PSU GR or equivalent in Wipro cat part No LR02-501-XXX-57-XX / Havells cat part No ENDURACITYLINERNEXGENSL 45WLED757 SASYBOPC.
Supply, Laying, connecting, charging, testing and commissioning LT XLPE cable electric, PVC insulated, armoured, pvc sheathed, heavy duty, electric cable 1100 volt grade with stranded aluminum conductor of size 6 sq mm 2 core conforming to IS : 1554 laid on ground/ wall/in trenches complete all as specified and directed.
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, levelling and hand punning complete all as specified in SSR part I and directed. Note: Only compacted thickness of sand will be measured and paid.
Supplying and laying unreinforced precast concrete cable cover, class LV type I, flat, size 250mm x 150mm x 40mm laid in trenches complete all as specified and directed.
Supplying, laying, fixing, passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured aith galvanisedmsteel wire or tape and overall PVC sheathed 10Sqmm, 2 core nominal cross section in service connection complete all as specified and directed.
Material and labour GI tubing 50mm dia light grade galvanized with all connected items (like suitable size of clamps, angle, nuts and bolts) for holding of pipe with pole complete all as specified and directed.
Supply and fixing fluorescent tube light flameproof type FLP-WP of T5 1x28w including integral reflector made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block etc and all accessories pre wired and including connecting up with twin core twisted flexible copper conductor with twin core twisted flexible copper conductor with suitable size complete all as specified and directed.
Supply and fixing Bulk Head, metal halide light fitting 2x36w flameproof type FLP-WP of 1x70W built in control gear box made aluminium alloy LM6 with all accessories, ballast, lamp holders, etc and internally prewired complete all as specified and directed. complete all as specified and directed.
Supply and fixing FLP/WP switch /isolator 10 Amp 1 pole ON/OFF complete all as specified and directed.
Supply and fixing aluminium strip, 32x6mm with saddle/porcelain insulator and fixing screws etc on roof / wall and connecting to test point etc complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level, connected to GI strip 25mm x 4mm as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber, MS funnel, wire gauge. CI cover with frame, 15 MM dia GI pipe light grade for protection of wire etc including necessary excavation in any type of strata, returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 5 of MES Sch Part I, connected to Earthing test point complete all as specified and directed on testing on completion.
Supply and fixing air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
Supply and fixing sheet metal enclosures, double door, for DBs when MCBs to be used 240 volts 8 way with 200 Amps rated bus bar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed.
SAHU AND SAHU CO.
SAI SIDDHI CONSTRUCTION
SHRI SAI ENTERPRISES
Bidder Name
SAHU AND SAHU CO.
SHRI SAI ENTERPRISES
GANGAJAL
SAI SIDDHI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .