Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance UNIT NO 117 IDEAL DEVAJI KESHAVAJI INDUSTRIAL ESTATE W T PATIL MARG CHEMBUR MUMBAI MAHARASHTRA 400071 | MUMBAI SUBURBAN | MAHARASHTRA | 400071 | Admitted-Finance |
| 2 | Admitted-Finance NO 3 BALAKRISHNA BUILDING NG ACHARYA MARG CHEMBUR MUMBAI MUMBAI MAHARASHTRA 400071 | MUMBAI SUBURBAN | MAHARASHTRA | 400071 | Admitted-Finance |
| 3 | Admitted-Finance 3 JAI SOMNATH SOC GOLIBAR ROAD 932 MUMBAI MAHARASHTRA 400086 | MUMBAI SUBURBAN | MAHARASHTRA | 400086 | Admitted-Finance |
Tender Value
₹73 L
EMD Value
₹1.5 L
Closing Date
27 Feb 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer(ESG)
3rd floor, V.S. Bhavan, Anushaktinagar, Mumbai-400094
Annual contract for day to day maintenance of electrical distribution systems at Anushaktinagar, New and Old Mandala, TMC/TIFR and Payalipada colonies, Mumbai
2023_DCSEM_740197_1
DCSEM/CQD/QSC/GSS/22-23/NIT-49 dt.13.02.2023
Open Tender
Electrical Works
Item Rate
365 days
Anushaktinagr, new and old mandala tmc tifr etc.
Please refer tender document
8 documents required · 8 mandatory
₹0
₹1.5 L
29 Mar 2023
14 Feb 2023
28 Feb 2023
14 Feb 2023
27 Feb 2023
14 Feb 2023
14 Feb 2023 - 20 Feb 2023
Amount
Assisting dept. technicians in attending day to day break-downs, opeartion and maitenance under the supervision of dept. shift in charge as per tender specifications and as instructed by E.I.C
Complete cleaning of substations rooms,Electrical rooms,DG set rooms/yards inside and outside, outer surface of electrical panels/equipment, substation premises transformer yards as per attached list including of cutting of vegetation around rooms as instructed,including sweeping of floors /walls/ceiling, mopping of floors, cutting of grass /tree branches near substation premises, transformer yard and also disposing the same,shifting of scrap materails at various places to central place using hand cart and as per instruction of EIC. Note: a)The contractor has to arrange all consumable materials such as heavy duty vacuum cleaner,brooms, bleaching powder, mopping sticks, choppers, buckest and cloths etc. for carrying out the work. b) Semi skilled labour shall be deputed for the work and the manpower shall have basic knowledge about electrical installation and safety. c) The report shall be submitted to shift-in-charge and also get the report certified by shift in charge
Cleaning of substations rooms,DG set rooms/yards inside and outside, outer surface of electrical panels/equipment, substation, DG room/yard premises, transformer yard etc. Approx. size of Substation, DG set room/Yard is ranging from 6M x 4M to 30M x 20 as per specification mention in item no.8
Cleaning of Electrical rooms inside and outside, outer surface of electrical panels/equipment etc.approx. size of electrical room is ranging from 3M x 2M to 6M x 4M as per specification mention in item no.8
Cleaning of Electrical rooms/meter rooms at Vajra Bldg. outer surface of electrical panels/equipment etc.approx. size of electrical room is ranging from 2M x 3M to 2M x 6M as per specification mention in item no.8
Supply of spares for day to day maitenance
RCBOs
63 A FP, 30mA sensitivity,AC type
40 A FP, 30mA sensitivity,AC type
25 A, DP, 30mA sensitivity,AC type(compact 2module)
32 A, DP, 30mA sensitivity,AC type(compact 2module)
40A,DP, 30mA sensitivity,AC type
63A,FP, 300mA sensitivity,AC type
MCBs & enclosures
40A-63A FP, 10kA,MCB
40A-63A,SP,MCB
40A-63A,DP,MCB
Enclosure for DP/FP MCB
Enclosure for FP RCBO's
SFU & Isolators
FN (SK95651)/FNX 63
Fuse links
63A bolted type HRC fuse
32A,bolted type HRC fuse
6-32A HF type
63A HF type
80A,bolted type HRC fuse
Fuse bases
HK 32B of M/s L&T make
HK 63B of M/s L&T make
HK 32H of M/s L&T make
HK 63H of M/s L&T make
HK 125B of M/s L&T make
Indication lamps
48V,DC/110V,DC/230V,AC LED indication lamp(green/red/Yellow/amber)
48V,DC/110V,DC/230V,AC LED indication lamp(White/Blue)
Wires & cables
FRLS garde PVC insulated 6 sq.mm flexible copper wire
FRLS garde PVC insulated 10 sq.mm flexible copper wire
4CX 6 sq.mm cu flexible cable
3CX 6 sq.mm cu. Conductor XLPE Armoured cable
4CX 6 sq.mm cu. Conductor XLPE Armoured cable
single core 25sq.mm Cu. Multi stranded PVC insulated cable
single core 35sq.mm Cu. Multi stranded PVC insulated cable
single core 50sq.mm Cu. Multi stranded PVC insulated cable
6sq.mm/10sq.mm heavy duty copper tube terminals
16sq.mm/25sq.mm heavy duty copper tube terminals
35sq.mm/50sq.mm heavy duty copper tube terminals
70sq.mm/95sq.mm heavy duty copper tube terminals
6sq.mm/10sq.mm heavy duty copper reducer terminals
16sq.mm/25sq.mm heavy duty copper reducer terminals
35sq.mm/50sq.mm heavy duty copper reducer terminals
70sq.mm/95sq.mm heavy duty copper reducer terminals
copper heavy duty in-line connectors
6sq.mm/10sq.mm
16sq.mm/25sq.mm
35sq.mm/50sq.mm
70sq.mm/95sq.mm
120sq.mm/150sq.mm
240sq.mm/300sq.mm
Direct operated (direct mounting on contactors) over load realy for L&T make Power air break contactors.
RTO-2 (40-57A)60HP
RTO-3(75-110) 100HP
SPP relay with 2NO + 2NC(VSP-D2)
Power Contactor of M/s L & T make
Spares of Power Contactor of M/s L & T make
Front mounting Add on block MN A1
Front mounting Add on block MNX A2
Side mounting aux add on block for MNX95-650
TOP mount ADD ON BLOCK 2NO FOR MO-9-110, MO-0 CONTACTOR
TOP mount ADD ON BLOCK 2NO+2NC FOR MO-9-110, MO-0 CONTACTOR
TOP mount ADD ON BLOCK 1NO+1NC FOR MO 9-110, MO-0 CONTACTOR
Side mount ADD ON BLOCK 1NO+1NC FOR MO 9-110, MO-0 CONTACTOR
MNX18 spare contact without coil
MNX25 spare contact without coil
MNX32 spare contact without coil
Connectors
CSTSN5 with partition plate
CSTSN6 with pattition plate
CST RN5/RN6 with end plate
CTS 35L with partition plate
CTS 70L with partition plate
CBB 150 with partition plate
CBB 185 with partition plate
CBTDU4/CMDT4
Insulation mats
Insulation mat class-A,2mm thick as per IS 15652
Indsulation mat class-B,2.5mm thick as per IS 15652
Fabrication, supply, installation, Testing & commissioning of 14SWG M.S CRCA sheet hot dipped galvanised meter box of size approx. 550 x 400 x 220 mm complete with following & as instructed by Engineer incharge. 1) Space provision for three phase energy meter 10 - 60 Amp - 1 No. 2) Space provision for FP RCBO. 3) 4 nos of stud type connector suitable for connecting cables of sizes upto 35 sq.mm. simialr to CSTSRN6 of M/s connectwell make with terminal channel for fixing. 4) Interconnecting wires 6 sq.mm
Fabrication, supply, installation, Testing & commissioning of 14SWG M.S CRCA sheet hot dipped galvanised cover/ Gland plates of required size for meter box/MDB/Feeder pillars ect. With suitable sizes of cable gland holes, including fixing with suitable sizes of screws etc.& as instructed by Engineer incharge. Note:- Scope also includes disconnection & connection of various sizes of existing cables.
Supply, installtion of lead acid batteries 2V, 150AH plante battery similar to YKP-13 of M/s. Exide make
Supply, installation, testing and commissioning of earth station with heavy dipped GI earth plates electrode 600 x 600 x6.0 mm in size at the depth minimum of 2.5 m below ground level (bottom of Plate) confirming to IS 3043 complete withall required materials like coke / charcoal, salt, G.I nut bolts, washers, 19 mm dia GI pipe (B class), 150 mm thick concrete wall chamber of suitable size duly plastered, heavy duty (minimum 6 mm thick) M.S chequred plate cover associated materials like 40 x 40 x 5 mm angle iron frame work, hinged locking arrangements, complete with funnels, GI test links (50 x 6 mm), two runs of 25 x 6mm G.I strips for connecting G.I plate & test link etc. including excavation of ground in all types of soils, refilling & removal of excess earth within a radius of 3000 m etc. all as required as per thedrawing specifications & instructed by Engineer-in-charge. Note:- The chamber cover & frame shall be got approved by Department & painted with two coats of red oxide & one coat of enamel paint.
Supply, installation of heavy dipped following GI strip fixed to wall / slab / column / beam with 2mm thick GI saddle or in ground at a depth of 750 mm below ground level including excavation in all type of soil, refilling and removal of excess earth within a radius of 500 mtrs., temporary reinstatement and back filling of trench, interconnection of earth strip by welding,applying cold zinc spary, painting with two coats of black bituminous compound for earth strip in ground and green colour enamel painting strip on surface etc. all as required & instructed by the Engineer-in-charge
25X 3mm in ground
25x6mm in ground
25X 3mm on Wall/coloum/beam/bus ducts
25x6mm on Wall/coloum/beam/bus ducts
K Sharma Electricals Private Limited
Radha Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .