| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹18.3 L+₹64,725 (3.66%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹18.9 L+₹1.3 L (7.10%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹19.5 L+₹1.8 L (10.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹21.1 L+₹3.4 L (19.4%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
23 Sept 2021, 6:00 pmClosed
GE (AF) Jammu
Air Force Station Jammu
CA NO GE/AFJ-21/2021-22 REPAIR AND MAINTENANCE OF CEILING FANS,EXHAUST FANS,WALL MOUNTING FANS AND WINTER APPLIANCES, GEYSERS AND SOLAR WATER HEATER AT AF STATION JAMMU AND KALUCHAK UNDER GE (AF) JAMMU
2021_MES_470839_1
CA NO GE/AFJ-21/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Jammu
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Jammu
₹64,000
Yes
23 Nov 2021
26 Aug 2021
25 Sept 2021
26 Aug 2021
23 Sept 2021
9 Sept 2021
Amount
M & L for servicing solar FP collector by removing the flange plates, cleaning the collectors internally by using Descalo solution, removing the blockages in the collectors and refixing the flange plates, testing for satisfactory function all as specified and directed.
Material and labour for sevicing solar manifold and tank by removing all the tubes in the monifold, cleaning the tubes internally, removing the blockages in the tubes and cleaning the tank and removing all the impurities, assembling and testing for satisfactory funtion all as specified and directed.
Supply and fixing in repairs heating element 25mm to 32mm dia, ISI marked for solar water heating plant of capacity 3KW all as specified and directed by Engr in charge.
S & F flange plates of size 25 mm dia suitable for flat plate collectors incuding taking down old unseviceable flange plate all specified and directed.
Supply and fixing in repairs thermostat for solar water heating plant suitable size and ratings etc complete.
Supply and fixing in repairs flexible heat resistance rubber pipe (from inter connect plate collector to hot water tank) of size 25 mm to 32 mm dia etc with fixing clamp etc complete all as specified.
Taking down the collector from its position, removing the top glass of collector and carry out welding/brazing work to the collector and arresting the leakages in the collector, refixing top glass back, testing for satisfactory function all as specified and directed.
Taking down the old unserviceable solar flat plate collector by disconecting flange plates and rubber hose pipes and replacing with new flat plate collector of same size and model, connecting flange plates and rubber hose complete, testing for proper functioning all as specified and directed.
M&L for sub main wiring with two run of 6.00 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLS cable in and including electrical grade PVC conduits of desired colour not less than1.2 mm thick and of 25 mm dia & 4 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one. Make of wire-- Finolex/Havells/Plaza.
Repair, maintenance and servicing of storage type electric water heater (geyser) of capacity 25 to 50 litres comprising of the following tasks at different locations including taking down, transportation to work shop ,opening the geyser, replacement of defective spares and reinstalling the same including testing as directed by Engineer-in-charge. Make : Bajaj, Ditz, Primer, Galco, Racold, Havells, Jaguar or any other make.
(a) Inspection of geysers includes taking down, transporting to works shop for repair, (dismantling) opening descaling, brushing cleaning of storage tank
(b) Check and correct earth continuity of electrical items
(c) Replacement of neon lamp / indicator lamp if defective.
(d) Inspect over flow/vent pipes and remove blockage/ obstructions if any.
(e) Examine water tightness tank after cleaning and necessary measures to make the same water tight if not.
(f) Check thermostat for its proper functioning
(g) Visual examination of fusible plug to ensure its intactness.
(h) Checking of dead weight type high pressure release valve ( PRV ) by removing dead weight protection cleaning the seat and ensuring that the vent hole is not blocked / chocked
j) Descalling of the immersion type heating element and cleaning with diluted hydrochloric acid and refixing.
k) Checking and adjustments of pressure reducing valves, carrying out operation of all stop cocks & ensure free movement of all working parts.
l) Replacement of the rubber / PVC gasket to ensure water tightness
m) Testing of Geysers after repairs
n) Replacement of defective components such as thermostat safety valves fusible plug, Heating elements, storage tank apparatus plate etc. Note:- Spare components will be measured and paid separately as supply only under relevent item of Sch 'A'. These parts shall be of the same make of which the geyser is in repair.
Supply only Heating element with rubber washer ('O' ring) cap 1.5KW/2 KW, trangular/round type complete all as specified and as directed. Make- Theetta/Micron/DasPass/Bajaj/Racold/Havells/ Jaguar or as per existing make
Supply only top/bottom plate of size suitable for 25 litres capacity geyser with new machine screws complete all as specified and as directed. Make: As per recommendation of manufacturer's of Geyers of approved makes
Supply only top/bottom plate of size suitable for 50 litres capacity geyseras per existing type and make with new machine screws complete all as specified and as directed
Supply only indicator bulb neon round / square type single phase 230 Volt complete all as specified and as directed. Make: Legrand/Schenieder/Havells/Bajaj
Supply only Safety plug 15mm ( brass ) for geyser cap 25/50 Ltr complete all as specified and as directed. Make: As per recommendation of manufacturer's of Geyers of approved makes
Supply only Thermostat 30°C to 70°C, 230 Volts complete all as specified and as directed. Make- Bajaj / Theetta / Micron / DasPass
Supply only Inner tank for geyser cap 50 litres of copper sheeting of gauge 22 (minimum) complete all as specified and as directed. Geyser make :- Bajaj / Usha / Racold / Venus / Vguard
Supply only Inner tank for geyser cap 25 litres of copper sheeting of gauge 22 (minimum) complete all as specified and as directed. Geyser make :- Bajaj / Usha / Racold / Venus / Vguard
M & L to repair the leakge of copper inner tank of geysers of any capacity by gas welding/brazing for water tightness complete and test under pressure.
Supply only Copper tube heavy duty 1/2" dia complete all as specified and as directed. Make: As per recommendation of manufacturer's of Geyers of approved makes
Supply only Copper tube heavy duty 3/8" dia complete all as specified and as directed. Make: As per recommendation of manufacturer's of Geyers of approved makes
Supply only aparatus plate copper material for geyser 25-50 Ltrs capacity Make: Havells/Bajaj/Racold/Usha/Vguard/venus or as per existing make
S & F gasket rubber ring for heater plate of any size geyser.
Supply only Glass wool of approved quality as recommended by the approved manufacturer's of geysers complete all as specified and as directed. Make: As per recommendation of manufacturer's of Geyers of approved makes
Supply only non return valve(NRV) brass of 15mm bore, after dismantling old unserviceable NRV of any size all as specified and directed.
Taking down loose geysers of any capacity from wall & shifting to new place within 1 to 1.5m distance (available in same location) , refixing the geysers complete with fastners and grouting of bolts & all necessary pipe connections and making good the disturbed wall surfaces all as directed. Note :- GI tubing if required shall be measured and paid separately.
Supply only PCB for suitable for 25 litres capacity digital type as per existing type and make of complete all as specified and as directed. Make: Jaquar / Racold / Bajaj / Havells
Supply and fixing in repairs MCB SPN 32 Amp, 240 volts, 50Hz, C series of breaking capacity 10 KA, complete all as specified and as directed. Make:- Legrand or its equivalent in Hager/Schneider/Havells
Supply and fixing in repairs MCB SP 20 Amp, 240 volts, 50Hz, C series of breaking capacity 10 KA, complete all as specified and as directed. Make: Legrand or its equivalent in Hager/Schneider/Havells
S & F PVC connection 450 mm long complete with brass nut, washers, seals, etc suitable for hot & cold water fixed in repairs complete all as specified and as directed. Make: Theetta / Micron / DasPass / Bajaj
S & F PVC connection 600 mm long complete with brass nut, washers, seals, etc suitable for hot & cold water fixed in repairs complete all as specified and as directed. Make: Theetta / Micron / DasPass / Bajaj
Scraping old paint of 25 litres capacity geyser (Approx painting area- 1.5 Sqm) making the surface smooth for painting, applying two coats of synthetic enameal paint over a coat of red oxide primer, with superior quality approved paint as approved by Engineer-in-Charge including writting MES No - on geyser with black paint of size as ordered complete all as specified and as directed.
Scraping old paint of 50 litres capacity geyser (Approx painting area- 2.00 Sqm) making the surface smooth for painting, applying two coats of synthetic enameal paint over a coat of red oxide primer, with superior quality approved paint as approved by Engineer-in-Charge including writting MES No - on geyser with black paint of size as ordered complete all as specified and as directed.
Multi core round PVC insulated copper conductor PVC sheathed cable, 1100 Volts grade cable 3 core 4 Sqmm complete all as specified and as directed. Make: Plaza/Havells/Polycab/Anchor
Taking down carefully copper/aluminium point wiring (Power/socket) surfaces / concealed with PVC sheathed cables drawn in and including PVC rigid conduit with all fitting and fixing accessories, earth wire, MS terminal boxes with hylam sheet top covers complete removing material to store for keeping in safe custody for reuse at site and making good the disturbed surfaces of wall ceiling and floors as per existing complete all as specified and as directed.
Point wiring concealed with 4 Sqmm copper conductor cable (multistrand) PVC insulated FRLS (unsheathed), surface type, drawing in and including PVC conduit 25 mm dia, cutting chases wall & ceiling and making good to disrurbed surface of wall ,ceiling etc,having wall thickness not less than 2 mm with sunk cast iron/pressed steel terminal boxes made out of 1.2 mm thick sheet including one coat of red oxide primer on internal and external surface covered with 3 mm thick hylam brand IS-2036 marked, laminated sheet cover (for mounting switches, sockets, regulators etc), including 2.5 Sqmm PVC insulated (multistranded) FRLS copper conductor continuous earth wire for Power point controlled by one switch on independent board complete all as specified and as directed.
Switch socket combination but 5A/16A, 5 in 1 flush type universal with fuse & neon incator including taking down old u/s socket outlet of any type complete all as specified and as directed.
S & F single pole and neutral encloser with two pin and earth plug and socket complete with one single pole MCB SP 20 Amps 240 volts with taking down old u/s SPN enclosure.
M & L for Framed work such as grills, gratings, etc. for water tanks, water cooler stand, AC Unit supports, UPS Battery Stand and similar work conforming to Fe.290.Gde-E-165 with two coat of synthetic enamaled paint over coat of red oxide primer all as directed and specified by Engineer In Charge
M & L for painting with two coat of synthetic enamaled paint over coat of red oxide primer all as directed and specified by Engineer In Charge.
Bib taps, 15mm dia fancy type, with crutch or butterfly handle screwed down, screwed for iron pipe or for brass furrule and fixed in repairs complete all as specified and as directed. Make: Parko/Seico/ESS ESS/Cera
Supply and fixing in repairs for stop valve, cast copper alloy, screw down high pressure, crutch handle screwed both end for iron pipe, fancy type, chromium plated for 15mm bore pipe.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exceeding 10cm girth complete all as specified and as directed.
Renewing tiles in patches, area n exc 5 sq.m. including removing and cleaning old tiles, preparing beds and laying or setting, replacemnet of broken tiles with new glazed tiles of same size and color to match with existing surface jointing and pointing new or old tiles complete all as specified and as directed by Engineer In Charge
Taking up or down steel tubing of 15mm bore dia and connections, including cleaning for refixing or removal to store complete all as specified and directed.
M&L for 15mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors/trenches complete including taking up or down old GI tubing all as specified.
Supply only geyser water (inlet/outlet) assembly brass for geyser cap 25 Ltr of any type.(Geyser make :- Super hot, Racold, Bathwell, Ditz, Kumar, Pearl, Classic, Pieco)
Supply only geyser water (inlet/outlet) assembly brass for geyser cap 50 Ltr of any type.(Geyser make :- Super hot, Racold, Bathwell, Ditz, Kumar, Pearl, Classic, Pieco)
Taking down carefully the existing unserviceable ceiling / Exhaust fans/ Wall mounted fan of any make/ model and sweep from different sites in the building for overhauling / servicing after disconnecting carefully cleaning and checking unserviceable components, and replacing the defective components such as bearing, rubber bush/bolt, gunmetal bush, capacitor burnt windings flexible cord, shaft and painting etc., including assembling after lubricating the movable components and installing in its original position connecting, testing and commissioning all as specified and directed by the Engineer-in-charge. Note:- For Sl. Item No. 49 above Bearing/ Gunmetal bush/ rubber bush bolt/ capacitor / cord flexiable / stator/rotor and painting only will be measured and paid separately under respective item.
M & L for rewinding of ceiling fans 1200/1400mm sweep of any make/model, including removal of existing burnt windings carefully from the slots,cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enmelled copper winding wire of same gauge/same number of turns as that of existing and connecting the coils suitable to operate on 230 volts single-phase AC supply permanent capacitor type, tying the windings and applying air dry insulating varnish and drying the windings including replacing the defective components such as bearing, gun metal bush,rubber bush/bolt, capacitor,flexible cord, shaft and painting including assembling after lubricating movable components complete including testing complete all as specified and directed for :- Note :-(1) Fan will be issued from AGE E/M store yard through gate pass.(2) Bearing/ Gunmetal bush/ rubber bush bolt/ capacitor / cord flexiable / stator/rotor and painting only will be measured and paid separately under respective item.
All as per item no 50 above but exhaust fan of 450/375/300mm sweep of any model/make.
All as per item no 50 above but pedestalt fan of any sweep of any model/make.
All as per item no 50 above but Wall mounting fan of any sweep , any model/make.
Supply only fan motor 150W 1500 RPM suitable for Exhaust fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge.Make CG
Supply only fan motor 150W 1500 RPM suitable for Padestal fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge.Make CG
Supply only fan motor 90W 1500 RPM suitable for Wall Mounting fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge.Make CG
Supply only ball bearing suitable for any fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge.Make TATA, SKF
Supply only gunmetal bush suitable for ceiling fan / wall mounting fan of any make/model/ sweep of 1200/1400 mm and Exhaust fan of any sweep all as specified and directed by the Engineer-in charge.
Supply only twin core PVC flexible copper conductor of size 23/0076 all as specified and directed by the Engineer-in-charge
Supply only capacitor of 2.5 Mfd. AC 230/240 volts, 50 Hz Make Epcos
Supply only capacitor of 3.15 Mfd. AC 230/240 volts, 50 Hz Make Epcos
Supply only capacitor of 4.0 Mfd. AC 230/240 volts, 50 Hz Make Epcos
Supply and fixed in repairs of PVC canopies of suitable size for ceiling fan of any make/model(set of two) with screws.
Supply only U clamps with rubber reel and nuts/bolts of suitable size with pins.
Supply and fixed in repairs of down rods upto 30 cm long heavy duty of any size with gudgeon pins complete.
Supply and fixed in repairs of fan blade assy suitable for 1200mm sweep ceiling fan (set of three) of any model/make complete.
Supply and fixed in repairs of fan blade assy suitable for 1400mm sweep ceiling fan (set of three) of any model/make complete.
Supply and fixed in repairs of fan blade assy suitable for 300mm sweep exhaust fan (set of three) of any model/make complete.
Supply and fixed in repairs of fan blade assy suitable for 380mm sweep exhaust fan (set of three) of any model/make complete.
Supply and fixed in repairs of fan blade assy suitable for 450mm sweep exhaust fan (set of three) of any model/make complete.
M & L for painting of ceiling fan with blades of any make/ model/ sweep of 1200/1400 mm required at any site of married and OTM Accn/E/M store by scrapping/scratching of old paints and apply with two coats of white enamel paint of approved quality and colour over a coat of primer including marking of MES No. All as specified and directed by the Engineer-in-charge.
All as per item No 71 above but for Exhaust fan of sweep 230/300/400/450-mm sweep.
Supply and fixed in repairs of rubber bush kit suitable for exhaust/wall mounting fan of any make/sweep complete.
Taking down existing louvers from any location or any height of bldg. with safety and re-fixed after repair with fastner complete all as specified and directed.
Supply and fixed in repairs of metallic / plastic louversof size 21" x 21" for 350mm/450mm/300mm sweep exhaust fan including fixing arrangment i.e. nuts , bolts, washers etc. complete all as specified and directed by Engr-in Charge.
S&F Modular regulator electronic rotary step type suitable for ceiling fan of sweep 1200/1400 mm complete all as specified and directed.Make:- Kinjal/ Penta/Usha/Orient/bajaj
Repairing of oil heater capacity of 2400 watt,Model no..OFRO9FIN with fan by replacing defective spare parts.
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
Note: (1) The repair has to carried out as and when required basis and accordingly site will be available in piecemeal wise and as directed by Enginer-in-Charge in the Air Force station area or Kaluchak area ass the case may be.
M/S VIDYA ENTERPRISES
M/S BIJRAL ENTERPRISES
asian traders
Rakesh Kumar Malia
R K BUILDERS
VIDHATA ELECTRICALS
M/S RAJ ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .