| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC 490 41 ROORKEE ROAD NEAR SHAHARANPUR BUS STAND MUZAFFARNAGAR UTTAR PRADESH 251002 | MUZAFFARNAGAR | UTTAR PRADESH | 251002 | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹11.7 L+₹78,635 (7.22%)Rejected-AOC 5021 1 CAT III MODERN HOUSING COMPLEX MANIMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L2 | Rejected-AOC Quoted L2 | |
| 3 | L3₹11.9 L+₹97,690 (8.97%)Rejected-AOC 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | L3 | Rejected-AOC Quoted L3 | |
| 4 | L4₹12.3 L+₹1.5 L (13.3%)Rejected-AOC 0 0 KAIMGANJ ROAD KUIYA SANT FARRUKHABAD UTTAR PRADESH 209745 | FARRUKHABAD | UTTAR PRADESH | 209745 | L4 | Rejected-AOC Quoted L4 | |
| 5 | L5₹13.4 L+₹2.5 L (23.3%)Rejected-AOC SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L5 | Rejected-AOC Quoted L5 |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
28 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Chandigarh
GE (AF) Chandigarh PIN-160003
REPAIRS TO PERIMETER LIGHTS, GUARD POST LIGHTS AND CONNECTED ITEMS AT AF STN CHANDIGARH UNDER GE (AF) CHANDIGARH
2023_MES_578267_1
GE(AF)/CHD/T-68/2022-23
Open Tender
Electrical and Maintenance Works
Works
183 days
Chandigarh
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹36,000
Yes
19 May 2023
31 Jan 2023
6 Mar 2023
31 Jan 2023
28 Feb 2023
14 Feb 2023
31 Jan 2023 - 6 Feb 2023
Amount
Repair and maintenence of street lights, high mast lights, guard post tower lights of any height and type of fittings viz HPSV/ HPMV/ MH/ flood light/ halogen light, LED light fittings 40/ 60watt/ 90watt/ 120watt/ 150watt/ 200watt etc. AC 230 volts any wattage from pole, opening of all components, thorough cleaning including washing of perpex cover, inspection for fault and replacing of defective spares/ parts required for smooth functioning, tightening of electric connections and making the fitting serviceable including rectification of fault in street light overhead line and underground cable complete all as specified and directed. Notes: (i) T&P/ safety equipments required to carry out the job work will be provided by contractor and rates for the same are deemed to be included in quoted rates. (ii) Quoted rate shall be deemed to include for provision of bucket crane of required height/ any other alternate arrangement for inspection & repairs. (iii) Supervisor shall collect complaint slip from main power house and deposit after completion of complaint to concerned JE E/M. Rectification/ repair shall be carried out on the same day failing which panel recovery @ Rs. 100/- per day per light shall be effected from contractor's dues without any notice. (iv) Spares/ components required to be replaced will be measured and paid separately under respective item of schedule.
Supply only constant current LED driver 10 watts IP 65 of following specifications:- (a) Operating voltage Range- V (in) 85 to 265 Volts AC. (b) Frequency- 50/ 60 Hz. (c) PF- 0.98. (d) V out- 28 to 43 V DC. (e) I out- 100 mA.
Supply only constant current LED driver 30 watts IP 65 of following specifications:- (a) Operating voltage Range- V (in) 85 to 265 Volts AC. (b) Frequency- 50/ 60 Hz. (c) PF- 0.98. (d) V out- 28 to 43 V DC. (e) I out- 100 mA.
Supply only constant current LED driver 45 Watts IP 65 of following specifications:- (a) Operating voltage Range- V (in) 187 to 280 Volts AC. (b) Frequency- 50/ 60 Hz. (c) PF- 0.98. (d) V out- 30 to 42 V DC. (e) I out- 250 mA.
Supply only constant current LED driver 60 watts IP 65 of following specifications:- (a) Operating voltage Range- V (in) 100 to 265 Volts AC. (b) Frequency- 50/ 60 Hz. (c) PF- 0.98. (d) V out- 30 to 42 V DC. (e) I out- 350 mA.
Supply only constant current LED driver 90 watts IP 65 of following specifications:- (a) Operating voltage Range- V (in) 120 to 277 Volts AC. (b) Frequency- 50/ 60 Hz. (c) PF- 0.98. (d) V out- 64 to 143 V DC. (e) I out- 700 mA.
Supply only constant current LED driver 120/ 150 watts IP 65 of following specifications:- (a) Operating voltage Range- V (in) 120 to 277 Volts AC. (b) Frequency- 50/ 60 Hz. (c) PF- 0.98. (d) V out- 64 to 140 V DC. (e) I out- 1050 mA.
Supply only constant current LED driver 200 watts IP 65 of following specifications:- (a) Operating voltage Range- V (in) 198 to 264 Volts AC. (b) Frequency- 50/ 60 Hz. (c) PF- 0.98. (d) V out- 71 to 21 V DC. (e) I out- 2800 mA.
Supply and fixing in repairs LED surge protection device having maximum discharge surge current (Imax)- 10kA (8/20 µs), Nominal discharge surge current (In)- 5kA (8/20 µs) and protection level (Up) upto 5KV upto 200 watt security light/ flood light fitting complete all as specified and directed.
Supply & replacement of energy saving LED street light 90 watt capacity high pressure die cast aluminium housing with seal toughened glass cover, light source should be multi LED SMD array with individual secondary lenses, colour temperature 9000K, 500(±) system efficiency should be minimum 110 lumen/ watt and minimum system lumen package of 9900 lumen as LM 79 operating voltage range 120-180 volts IP-66 THD less than 10%, surge protection minimum 5 KV with flash indication, driver should be potted/ CE certified/ R certified and driver efficiency 85% including making connection complete all as specified and directed.
Supply & replacement of energy saving LED flood light 50 watt capacity high pressure die cast aluminium housing with seal toughened glass cover, light source should be multi LED SMD array with individual secondary lenses, colour temperature 4900K, 500(±) system efficiency should be minimum 98 lumen/ watt and minimum system lumen package of 6000 lumen as LM 79 operating voltage range 120-180 volts IP-66 THD less than 10%, surge protection minimum 5 KV with flash indication, driver should be potted/ CE certified/ R certified and driver efficiency 85% including making connection complete all as specified and directed.
Supply & replacement of energy saving LED flood light 200 watt capacity high pressure die cast aluminium housing with seal toughened glass cover, light source should be multi LED SMD array with individual secondary lenses, colour temperature 6500K, 500(±) system efficiency should be minimum 120 lumen/ watt and minimum system lumen package of 6000 lumen as LM 79 operating voltage range 120-180 volts IP-66 THD less than 10%, surge protection minimum 5 KV with flash indication, driver should be potted/ CE certified/ R certified and driver efficiency 85% including making connection complete all as specified and directed.
Supplying and fixing 10sqmm flat twin core heavy duty cable 1100 volts grade PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire complete all as specified and directed.
Supplying and fixing 6sqmm flat twin core heavy duty cable 1100 volts grade PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire complete all as specified and directed.
Supplying, laying in trenches/ passing through tubing/ pipes or laid under floors or through walls/ ducts etc., jointing and testing, 1100 volts grade XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, LT electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 35 sqmm 3½ core, including both sides connection with and including cable lugs etc., including taking out existing unserviceable cable, complete all as specified and directed.
Supplying, laying in trenches/ passing through tubing/ pipes or laid under floors or through walls/ ducts etc., jointing and testing, 1100 volts grade XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, LT electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 25 sqmm 4 core, including both sides connection with and including cable lugs etc., including taking out existing unserviceable cable, complete all as specified and directed.
Supplying, laying in trenches/ passing through tubing/ pipes or laid under floors or through walls/ ducts etc., jointing and testing, 1100 volts grade XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, LT electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 16 sqmm 4 core, including both sides connection with and including cable lugs etc., including taking out existing unserviceable cable, complete all as specified and directed. Note for item No. 15.00 to 17.00: Excavation & eathwork, sand cushioning & brick protection shall be measured and paid for separately.
Supply and laying in replacement 40mm bore GI tubing light grade pipe with all fitting laid in trenches, fixed to well etc. complete all as specified and directed.
Supply and laying in replacement 50mm bore GI tubing light grade pipe with all fitting laid in trenches, fixed to well etc. complete all as specified and directed.
Supply and fix water proof ABS electric distribution box, wheather proof IP-65 protection suitable for outdoor use, pole mounted, factory made of size 300mm x 250mm x 150mm comprising one No. MCB SP 6 Amps, 240 volts TPN bus bar not less than 25mm x 5mm aluminium strip and fixing clamps of size 25mm x 5mm two nos including necessary nuts, bolts and locking arrangement with lock, pressure type, four Nos connection holes in each bus bar with nuts, bolts and washers made of galvanized iron and connection thimble etc. complete all as specified and directed.
S&F in replacement bracket fabricated out of 50mm dia GI light grade pipe 1.2 metre long bent to shape as directed and fixing to pole with clamps fabricated out of FI 40mm x 5mm, clamps duly painted with two coats of synthetic enamel paint over a coat of red oxide primer fixed with nuts, bolts & washers of suitable size complete all as specified and directed.
M&L for boring of holes under road, pavement, hardstanding etc. by any means for inserting GI/ CI/ HDPE pipe upto 100mm bore complete all as specified and directed.
Excavation in trenches in any type of soil n. exc. 1.5m deep and n. exc. 1.5m in width and getting out including forming bottom surface to required slope/ gradient for laying cables/ pipes etc. complete all as specified and directed. Notes: (i) Excavation shall be done carefully to avoid damage of existing cables and protection covers. (ii) Excavation work may be got carried out in short lengths for locating fault in underground cables at different locations.
Returning filling in excavated soil including spreading, levelling, watering and well ramming in layers, each layer not exceeding 25mm thick in soft/ loose soil complete all as specified and directed.
Removing excavated spoil n. exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
M&L for sand cushioning to cables with a layer of sand 8cm thick before laying the cable and 15cm thick punned down after laying and stretching of cable) complete all as specified. (Punned thickness (overall 18cm) shall be measured & paid).
M&L old size sub class ‘B’ bricks for protection to cable laid flat abutting each other perpendicular to direction of cable direction complete all specified and directed.
M&L for PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in coping of poles including necessary formwork complete all as specified and directed.
M&L for preparation old painted surfaces of LT steel poles 9.00m long and painting applying one coat of synthetic enamel paint in 30cm wide strips alternate in black and yellow colour upto 1.5 mtr height above muff and the remaining portion with one coat of aluminium paint and writing pole no on pole with white painnt, complete all as directed at site all as specified and directed.
Supply and installing electro mechanical timer switch Quartz 1 channel weekly dial conforming to with 200 hrs battery reserve, programming by captive segment, manual override function in sheet metal enclosure with TPN MCB 63 Amps and power contractor 63 Amps 3 phase (Coil voltage 230V 50Hz) and one No MCB 6 amps for remote switch control a power complete all as per manufacturer's specifications including taking down old unserviceable fittings of any size/ wattage complete all as directed.
Supply and fix aluminium cable lugs suitable for 10 Sqmm to 25 Sqmm size cable all specified and directed.
Supply and fix aluminium cable lugs suitable for 35 Sqmm to 50 Sqmm size cable all specified and directed.
Supply, fix, connecting and testing MCCB four pole, 63 Amps, 415 volts, 16kA breaking capacity with adjustable thermal setting having Ics= 100% Icu including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole, 100 Amps, 415 volts, 25kA breaking capacity with adjustable thermal setting having Ics= 75% Icu including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole, 125 Amps, 415 volts, 25kA breaking capacity with adjustable thermal setting having Ics= 100% Icu including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole, 160 Amps, 415 volts, 25kA breaking capacity with adjustable thermal setting having Ics= 70% Icu including taking down the existing one complete all as specified and directed.
S&F in replacement MCB, SPN, 230V, 6 Amps AC, 10 KA, 'C' series and 50Hz complete all as specified and directed
M&L repair to door hinges and door locks of LT panel board/ feeder pillar box of any size any description including scrubbing/ scratching of old rusted paint by burning through blow lamps and painting the complete of LT panel board/ feeder pillar box externally and internally with 02 coats of approved colour superior quality synthetic enamel paint over a coat of red oxide primer complete al as specified and as directed.
Site clearance including cutting of grass/ trimming of all bushes/ small trees upto a height of 10 feet in surrounding areas of perimeter security lights, E/M installations, panels, bus bar chambers etc. including sprinkling of herbicide solution as per manufacturer's instructions complete all as specified and directed.
M&L for dismantling old earthing and providing new earthing complete with galvanised steel earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to galvanised iron strip of size 25mm x 4mm by means of bolts, nut check nuts and washers earth strip protected by galvanized steel pipe 40mm bore (light grade) connected to test point all as shown in electrical plate No. 3 of SSR 2009 (Part-I) and including necessary excavation and earth work in any type of soil, 20mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1;2:4), type B-1 reinforced XPM of weight not less than 4 Kg/ Sqm and MS frame etc. complete & connected to earthing test point all as specified or indicated including brazing/ testing on completion complete all as specified and directed. Notes:- (i) The unit rate includes galvanised Iron strip and protection pipe upto (maximum 7.5m from earth plate) earth point/ test point. (ii) The complete earth system shall be guaranteed to give result less than 5 ohm resistance.
M&L fo replacement of factory made LT feeder pillar box of size 750mm x 750mm x 600mm provided with 4 strip copper bus bar (200 Amp, 1100 volts grade, 60cm long) duly sleeved with relevant coloured sleeves- 01 Set) cublcal outdoor type, weather proof fabricated out of 14 SWG MS sheet, mounted/ fixed on 50mm x 50mm x 6mm thick angle iron frame, 120cm, long angle iron legs grouted in PCC (1:2:4) type B-1 using graded stone aggregate as in foundation with front & rear openable door having locking arrangement, bottom space for cable entey duly painted with black enamel synthetic paint over a red oxide primer complete all as specified and directed.
Supply, fixing, connecting, testing & commissioning in replacement outdoor type LT cubical panel of size 1200mm x 1000mm x 650mm, factory made, compartment type, dust and vermin proof (IP-55) protection, floor mounted/ pedestal type, self supported, CPRI approved make, front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides with wire mesh, IP-65 protection, suitable for 1100 volts grade, 3 phase, 4 wire supply fabricated out of 3.15mm CRCA sheet duly powder coated, mounted/ fixed on 50mm x 50mm x 6mm thick angle iron frame, 120cm, long angle iron legs duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC (1:2:4) type B-1 using graded stone aggregate as in foundation, inter connection from main bus bars 60mm wide and 10mm thick of capacity 400 Amp, 4 strips duly sleeved with relevant coloured insulation heavy duty mounted on insulators, suitable size of double compression type cable glands for incoming & outgoing cable, marking of cable with marked MCCB of building/ connected load complete all as specified and directed comprising the following:-
Supply, fixing, connecting, testing & commissioning in replacement outdoor type LT cubical panel of size 1200mm x 1000mm x 650mm, factory made, compartment type, dust and vermin proof (IP-55) protection, floor mounted/ pedestal type, self supported, CPRI approved make, front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides with wire mesh, IP-65 protection, suitable for 1100 volts grade, 3 phase, 4 wire supply fabricated out of 3.15mm CRCA sheet duly powder coated, mounted/ fixed on 50mm x 50mm x 6mm thick angle iron frame, 120cm, long angle iron legs duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC (1:2:4) type B-1 using graded stone aggregate as in foundation, inter connection from main bus bars 60mm wide and 10mm thick of capacity 400 Amp, 4 strips duly sleeved with relevant coloured insulation heavy duty mounted on insulators, suitable size of double compression type cable glands for incoming & outgoing cable, marking of cable with marked MCCB of building/ connected load complete all as specified and directed comprising the following:-
M/s APEX ENTERPRISES
KUMAR AND COMPANY
R S ENTERPRISES
M/s Friends Engineering Works
HARISH SALES CORPORATION
L-7 Primewave Communications
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .