GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIRS/MAINTENANCE OF DUCTABLE PACKAGE ACs SPLIT TYPE ACs AND COOLING APPLIANCES AT DIFFERENT LOCATIONS OF RCI UNDER GE I RND RCI HYDERABAD
2022_MES_539990_1
8728
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE(I) R AND D RCI
MES enlisted Class D category c i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹80,000
Yes
14 Oct 2022
22 Jul 2022
23 Aug 2022
22 Jul 2022
19 Aug 2022
5 Aug 2022
Amount
M&L for in replacement of sub main wiring for A/C using two single core PVC insulated cable 4.0 sqmm copper conductor multi stranded and one run of 4.0 sqmm copper conductor insulated cable using as earth wire and drawing into PVC Conduit / Casing and Caping of suitable size and concting terminal ends conecting to earth dolly complete all as specified and directed.
Supply only as in replacement MCB, SP, 32Amps, 10KA, 240volts, ISI marked complete all as specified. Make: Legrand / Havells / Siemens / L&T / IndoAsian OR equivalent as approved by GE
Supply only as in replacement single pole and neutral sheet metal enclosure with a two pin and earth plug & socket complete with and including one single pole MCB SP 20 Amps 10KA, 240 Volts complete all as specified. Make: L&T / Siemens / C&S/ Legrand/Havells
Supply only as in replacement as in replacement remote hand set suitable for split type AC with batteries complete all as specified. Make:LG/Hitachi/Bluestar/Voltas/OEM
Taking down window type air condtioner of any capacity by disconnecting all electric connections, cleaning the components i. e. condensor coil, evoparative coil with caustic soda and fixing back to its original position and reconnecting the AC with the electrical connections including testing complete all as specified.
Taking down the old unserviceable compressors, supply and fix new hermetically sealed Rotary / Reciprocating compressors suitable for window type air conditioner of 2Ton capacity with mounting assembly such as rubber springs etc., after disconnecting all electric connections, including alteration of refrigerant piping suction and discharge, pressure testing the complete system with nitrogen after carrying out repairs, flushing out the complete system, vaccumising and gas charging with R-22 refrigerant gas to obtain designed cooling closing of suction and discharge valves complete all as specified and directed.(Note: Copper Brazing rods, LPG Gas Tins shall be arranged by the contractor & Refrigerant Gas measured & paid separately)
All as per item No 6 above but of 1.5Ton capacity for window type air conditioner.
All as per item No 6 above but of 2Ton capacity for split type air conditioner.
All as per item No 6 above but of 1.5Ton capacity for split type air conditioner.
All as per item No 6 above but of capacity 4.5TR for cassette type / vertical type air conditioner. Make for item No 6 to 10 : LG / Hitaichi / Bluestar / Emersion / OEM
Supply only as in replacement Relay for the window type air conditioners of1.5/ 2 Ton capacity complete all as specified.
Supply only as in replacement outdoor unit stand made out of 19SWG mild steel powder coated sheet,including Anchor nut & bolts 06 Nos. complete all as specified.
Supply only as in replacement Thermostat switch including knob plate for the window type air conditioners of 1.5/2 Ton capacity complete all as specified.
Supply only as in replacement Starting Capacitor 80 MFD for split type air conditioners of any capacity complete all as specified.
Supply only as in replacement Starting Capacitor 60 MFD for split type air conditioners of any capacity and water coolers of any capacity complete all as specified.
Supply only as in replacement Running Capacitor (50+2) & (50+6) MFD for split type air conditioners of any capacity complete all as specified.
Supply only as in replacement Running Capacitor of 45 MFD for split type air conditioners of any capacity complete all as specified.
Supply only as in replacement Running Capacitor 36 MFD for split type air conditioners and water coolers of any capacity complete all as specified.
Supply only as in replacement 6/10 MFD capacitor for fan motor of window / split type air conditioners and water coolers of any capacity complete all as specified.
Supply only as in replacement Capacitor but 2.5/4 MFD capacitor for fan motor of water cooler / Desert coolers complete all as specified. Make for item No 14 to 19 : Tibcon / L&T / Concap / Keltron
Leak testing of complete gas circulating system with dry nitrogen, flushing out complete system, vaccumising, charging R-22 refrigerant gas including replacement of unserviceable of copper filter, capillary tube, ‘U’ foam etc., with new ones, cutting brazing, leak detection and rectification etc., for window type Air Conditioner of 1.5/2 Ton capacity complete all as directed.(Note: Nitrogen shall be arranged by the contractor & Refrigerant Gas measured & paid separately)
Taking out the unserviceable dual speed blower fan motor 0.2(1/5) HP of window AC1.5/2.0 Ton by disconnecting all electrical connections, opening the same and rewinding the burnt out motor with super enamelled copper wire duly insulated including replacement of bushes, mounting rubbers etc., with new ones, reassembling, reconnecting and testing complete all as specified and directed. (Note - labour element required to taking down the motor & refixing in position shall be done through outsourcing employees)
Supply only as in replacement FR PVC insulated, round sheathed 3core 2.5Sqmm, multistranded copper conductor industrial cable, 1100V grade, ISI marked complete all as specified. Make- Havells/Glostar/Finolex
Supply only as in replacement balanced Centrifugal blower fan blade for the Ductable air conditioners of 5 to 8.5 Ton capacity complete all as specified.
Supply only as in replacement outdoor unit brass valve of size 5/8" complete all as specified .
Taking down the water cooler of any capacity by disconnecting all electric connections, cleaning the components i.e., condenser coil, evaporating coil including inner tank with caustic soda and fixing back to its original position and connecting up with electrical connections complete all as specified and directed.
S & Fix in repairs hermetically sealed compressors for water cooler of 40/80 litres capacity with mounting assembly such as rubber springs etc., after disconnecting all electric connections, including alteration of refrigerant piping suction and discharge, flushing out the complete system, pressure testing the complete system with nitrogen after carrying out repairs, vaccumising and gas charging with refrigerant gas to obtain designed cooling closing of suction and discharge valves complete all as specified. (Note: Copper Brazing rods, LPG Gas Tins shall be arranged by contractor & Refrigerant Gas measured & paid separately)
All as per item No 27 above but for water cooler of 60/120 and 60/150 litres capacity Make for item No 27 & 28: Kirloskar/Tecumesh / LG / Voltas / Copland
Supply only as in replacement Relay assembly for water cooler of 40/80 capacity complete all as specified.
Supply only as in replacement Relay assembly for water cooler of 60/120 and 60/150 litres capacity complete all as specified.
Supply only as in replacement Over Load Protector suitable for water coolers of any capacities complete all as specified. Make: Annapurna / Arvind / Ranutral
Supply only as in replacement Fan Motor Blade for the water cooler of any capacity complete all as specified.
Supply only as in replacement Fan Motor for the water cooler of any capacity complete all as specified. Make: Truemax /
Flushing out the complete refrigerant system, charging refrigerant gas including replacement of capillary tube and ‘U’ foam with new ones, cutting, brazing, leak detection and rectification in the entire system and commissioning the water cooler of 40/80, 60/120, & 60/150 litres capacity complete all as specified. (Note: Nitrogen shall be arranged by the contractor & Refrigerant Gas measured & paid separately)
Supply only as in replacement brass chromium plated Push/Lifting Cock 15mm bore for the water cooler complete all as specified.Make: Jayson/HMP/Viking
Supply only as in replacement Thermostat switch including knob plate for water cooler of any capacity complete all as specified. Make: INDOFOSS/RANUTROL/ANNPURNA
Taking out the unserviceable fan motor of water coolers of any capacity by disconnecting all electrical connections, opening the same and rewinding the burnt out motor with super enamelled copper wire duly insulated including replacement of bushes, mounting rubbers etc., with new ones, reassembling, reconnecting and testing complete all as specified and directed.
Supply only as in replacement 15mm bore Ball brass valves, high pressure, with polythene float and fly nut complete all as specified.
Supply only as in replacement 15mm bore PVC connection heavy duty with brass nuts, 600mm length, for water coolers complete all as specified.
Taking down the water coolers of 40/80 litres capacity by disconnecting all connections, cleaning all the components, denting and painting the outer exposed surfaces of cooler unit with one coat of synthetic enamel paint with spray gun and connecting up the cooler complete all as specified and directed.
All as per item No 40 above but water cooler of 120/150 litres capacity.
Supply only as in replacement Fan Motor 1/7 HP for the evaporative desert cooler of capacity of 3000~4000 Cum/Hour complete all as specified. Make: Khaitan / Crompton Greaves / Usha / Almonard/OEM
Supply only as in replacement Water Pump, 230 Volts, 50Hz, 1/66 HP for the evaporative desert cooler of capacity 3000~4000 Cum/hour complete all as specified. Make: Khaitan / Crompton Greaves / Usha / Coolhome
Supply only as in replacement Khus-Khus pads for the evaporative desert cooler of any capacity complete all as specified.
Cutting and removal of the damaged/leaking water tank portion of the evaporative desert cooler of capacity 3000~4000 Cum/Hour, supply, fabricate water tanks of same capacity, size and gauge out of galvanized iron sheet including necessary welding etc., and painting the outer surfaces of the entire desert cooler body with one coat of synthetic enamel paint with spray gun and connecting up the cooler complete all as specified and directed.
Supply only as in replacement front grill for the evaporative desert cooler of capacity 3000~4000 Cum/Hour to match with the existing model complete all as specified.
Servicing of the outdoor/indoor unit of split AC of any capacity by disconnecting all electrical connections, cleaning components i.e. condenser coil and evaporating coil by air blower to remove the dust and dirt and cleaning with caustic soda and cleaning the Indoor unit & air filters complete all as specified.
Supply only as in replacement Potential relay for split type air conditioner of 1.5 Ton capacity complete all as specified.
Supply only as in replacement PVC / Fiber fan blade for condensor motor of split type air conditioners of 1.5/2 Ton capacity complete all as specified.
Supply only as in replacement metallic fan blade for condensor motor of split type air conditioners of 1.5/2 Ton capacity complete all as specified.
Supply only as in replacement 2 pole contactor AC3 rating of 12Amps for split type AC complete all as specified. Make: L&T CAT No CS90234 or equivalent in Legrand / Siemens / ABB / Schneider
Supply only as in replacement outdoor unit brass valve of size 1/4" complete all as specified .
Disconnecting electrically burnt out condensor motor of split AC, dismounting from existing position, over hauling, re-winding with super enamelled copper wire duly insulated, varnishing, replacing the worn out bearings, greasing and fixing back in original position, connecting and testing complete all as specified and directed. (Note - labour element required to taking down the motor & refixing in position shall be done through outsourcing employees)
Leak testing of complete gas circulating system with dry nitrogen, flushing out complete system, vaccumising,and charging the R-22 refrigerant gas including replacement of unserviceable of copper filter, capillary tube, ‘U’ foam etc., with new ones, cutting brazing, leak detection and rectification etc. for the split type Air Conditioner of 1.5/2 Ton capacity complete all as directed. ( Note: Nitrogen shall be arranged by the contractor & Refrigeration gas will be measured & paid separately)
Supply only as in replacement Air Filter indigenous washable type suitable for split type air conditioners of 1.5/2Ton capacity complete all as specified. Make: Porolator/Airtech/Kirloskar/Airfiko
Supply only as in replacement Balanced Centrifugal Blower for the split type air conditioners of 1.5/2 Ton capacity complete all as specified. Make:ACRO/Bluestar/Accel/Ventura/ACCB
Supply only as in replacement evaporating coil made out of 25 guage copper tubing having 30/34 gauge Copper fin 4.5cm length for split type AC of 1.5/2 Ton capacity complete all as specified. Make: Coil Co India/Blue Star/Jaypee/Voltas
Supply only as in replacement copper condenser coil for split type AC of 1.5/2Ton capacity complete all as specified . Make: Coil Co India/Blue Star/Jaypee/Voltas
Supply only as in replacement Indoor Unit with all accessories suitable for 1.5/2 ton capacity Split AC including cutting, brazing, leak testing, reconnecting and testing complete all as specified and directed. Make: Crompton Greaves/Voltas/Blue Star/Carrier /OEM
Disconnecting the electrical connections, pumping down complete system, and removing the split type AC of 1.5/2 ton capacity including copper pipe from the existing position and shifting the same to the new location, re-connecting the AC after making suitable hole in the wall, flushing out the complete system, pressure testing the complete system with nitrogen after fixing, vaccumising topping up refrigerant gas to obtain designed cooling closing of suction and discharge valves, providing necessary connections, including closing the hole with cement mortar and finishing surfaces to match with the existing complete all as specified. (Note : Copper pipe line, Electrical cable will be measred & paid separately)
Supply only as in replacement Copper pipe of size 1/4" including tubular heat/cold resistant rubber / foam type insulation complete all as specified.
All as per Sl Item No 61 above but of size 3/8''.
All as per Sl Item No 61 above but of size 1/2''.
All as per Sl Item No 61 above but of size 5/8''.
All as per Sl Item No 61 above but of size 3/4''.
Taking down the unserviceable printed circuit board (PCB) of 1.5/2/3 (2 x 1.5 split) Ton capacity split AC by disconnecting all electrical connections, repairing the same and connecting up, testing and commissioning complete all as specified and directed.
Supply only as in replacement Printed Circuit Board (PCB) with remote set suitable for 1.5/2/3 (2 x 1.5 split) Ton capacity split AC complete all as specified. Make: Voltas/Carrier/Blue Star/LG/Hitachi
Supply only as in replacement Indoor unit swing motor for 1.5/2/3 (2 x 1.5 split) Ton capacity split type AC complete all as specified.
Supply only as in replacement Indoor blower fan motor for 1.5/2/3 (2 x 1.5 split) Ton capacity split type AC complete all as specified. Make: Voltas/Carrier/Blue Star/LG/Hitachi/OEM
Supply only as in replacement Refrigerant gas R-22
Supply only as in replacement Refrigerant gas R- 410 A
Supply only as in replacement Refrigerant gas R-134 A
Supply only as in replacement Refrigerant gas R-32
Supply only as in replacement PVC flexible drain pipe of 3/4'' dia complete all as specified.
Supply only as in replacement brass dummy nuts of existing size for Split typ AC 1.5 / 2.0 ton complete all as specified.
Supply only as in replacement Float valve 15 MM bore with PVC spindle and PVC ball complete for Water Coolers of any capacity/make complete all as directed.
Supply only as in replacement Plug Top 5 amps, 230 volts suitable for Desert Coolers, Water coolers 40 Ltrs complete all as specified Make :Anchor / Maru
Supply only as in replacement Insulation felt / foam insulation for split type AC's copper piping tube inlet / outlet to out door unit approx 2.5 meters complete all as directed.
Supply only as in replacement bearing and bush for split type /cassette type / vertical type air conditioner's Condenser fan motor of capacity up to 0.75HP complete all as directed.
Supply only as in replacement 3 pin industrial Plug Top single phase, 230 Volts, AC suitable for industrial metal clad socket complete all as directed.
Supply only as in replacement Air Filter indigenous washable type suitable for out door unit complete all as specified.
Supply only as in replacement metallic fan blade for condensor motor suitable for 0.5HP complete all as specified.
Supply only as in replacement new refrigerant control cut out of Model MWP-30 including connecting and testing complete all as specified.
supply only as in replacement new catch all filter complete all as specified. Make: Carrier/Dry All/Danfoss
Taking down the old unserviceable compressors, supply and fix new hermetically sealed scroll compressors suitable for package type air conditioner of 5.5 Ton capacity with mounting assembly such as rubber springs etc., after disconnecting all electric connections, pumping down complete system including alteration of refrigerant piping suction and discharge, pressure testing the complete system with nitrogen after carrying out repairs, flushing out the complete system, vaccumising and gas charging with R-22 refrigerant gas to obtain designed cooling, closing of suction and discharge valves complete all as specified and directed.(Note: Copper Brazing rods, Nitrzen Gas,LPG Gas with cylinders shall be arranged by the contractor & Refrigerant Gas measured & paid separately)
All as per item No 86 above but for 7.5 Ton capacity package type air conditioner.
All as per item No 86 above but for 8/8.5 Ton capacity package type air conditioner.
All as per item No 86 above but for 3TR capacity package type air conditioner. Make for item No 86 to 89: Copeland/Voltas/Bluestar/OEM Note for item No 8 to 11: Labour required for carrying out the job shall be from the outsourcing persons employed under Sl item No 1 to 5 above.
Supply only as in replacement 'V' belts of size A-22, A -24/25, A-26, A-27, A-28 complete all as specified.
Supply only 'V' belts of size A-41, A-42, B-41 & B-42 complete all as specified. Make for item No 12 & 13: Dunlop/Fenner/PIX/ Continental
Supply only as in replacement Single phasing preventor, VSP 2, 415V complete all as specified. Make: Minilec/Powertek/GIC.
Supply only as in replacement 3 pole contactor AC3 rating of 415 volts, 25Amps for complete all as specified.
All as per item No 93 above but of AC3 rating of 415 volts, 18Amps.
All as per item No 93 above but of AC3 rating of 415 volts, 12Amps.
All as per item No 93 above but of AC3 rating of 415 volts, 9Amps. Make for item No 93 to 96 : L&T / Legrand / Siemens / Schneider /C&S
Leak testing of complete gas circulating system with dry nitrogen for a period of 24hours, flushing out complete system, vaccumising, and charging the R-22 refrigerant gas including replacement of unserviceable of copper filter, capillary tube, ‘U’ foam etc., with new ones, cutting, brazing, leak detection and rectification etc., for ductable split type Air Conditioner up to capacity of 3 Ton complete all as directed. (Note: Nitrogen shall be arranged by the contractor & labour element required to complete the job shall be done through outsourcing employees)
All as per item No 97 above but for 5.5/5 Ton capacity air conditioner.
All as per item No 97 above but for 7.5/8/8.5 Ton capacity air conditioner.
All as per item No 97 above but for 10.5/11 Ton capacity air conditioner. Note for item No 97 to 100 : Nitrogen to be arranged by the contractor, Labour required for carrying out the job shall be from the outsourcing persons.
Cleaning of evaporator coil of 1.5 TR to 3 TR capacity Air Conditioner with approved cleaning acid recommended by manufacturer by forced feed method to remove all the dust particles deposited on the coil and fins, cleaning of the filters, greasing to AHU bearings of liquid lines, strainer, expansion valves etc., and testing complete all as specified and directed. (Note:Necessary cleaning Acid / coil cleaner arranged by Contractor)
All as per item No 101 above but for 5/5.5Ton capacity.
All as per item No 101 above but for 7.5/8 Ton capacity.
All as per item No 101 above but for 8.5/10.5/11Ton capacity.
Supply only as in replacement over load relay range from 1.4 to 2.3Amp, 415 Volts complete all as specified.
All as per item No 105 above but for relay range of 3 to 5Amp.
All as per item No 105 above but for relay range of 9 to 15Amp. Make for item No 105 to 107: Havells/L&T/IndoAsian/ Siemens/C&S
Disconnecting and removing the unserviceable hand remote, cord type with printed panel circuit board (PCB) for 5.5/7.5/8.5/10/10.5 Ton ductable Split AC from position and replacing the same with new hand set remote, cord type with printed circuit board (PCB) including connecting complete all as specified. Make: Carrier or equivalent as approved by GE
Supply only as in replacement 32 Amp HRC fuses of push/screw type.
Supply only as in replacement 63 Amp HRC fuses of push/screw type. Make for item No 110 & 111: Havells/L&T/Siemens/ IndoAsian
Disconnecting electrically and dismounting from existing position, induction motor of 1 HP capacity, over hauling, re-winding with super enamelled copper wire duly insulated including varnishing, replacing the worn-out bearings, greasing and fixing back in original position, connecting up and testing complete all as directed. (Note - labour element required to taking down the motor & refixing in position shall be done through outsourcing employees)
All as per item No 112 above but induction motor of capacity 1.5 HP
S.S.ENGINEERING CORPORATION
M/S J J ENTERPRISES
Universal refrigeration and Engineering Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .