Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.22Accepted-Finance | L1 | Accepted-Finance _ | |
| 2 | L2₹13.35+₹0.13 (0.98%)Accepted-Finance | L2 | Accepted-Finance _ | |
| 3 | L3₹13.65+₹0.43 (3.25%)Accepted-Finance | L3 | Accepted-Finance _ | |
| 4 | _₹13.98Accepted-Finance | _ | Accepted-Finance _ |
Tender Value
Refer Docs
EMD Value
₹27,000
Closing Date
18 Aug 2021, 3:00 pmClosed
Executive Engineer, ED Budgam, KPDCL
Office of the Executive Engineer, ED Budgam, KPDCL
Shifting of Electrical Lines and transformers from the alignment of PMGSY road under the jurisdiction of ED Budgam_ KPDCL.
2021_PDD_132824_1
EDB_48_of_2021_22
Open Tender
Electrical and Maintenance Works
Turn-key
15 days
ED BUDGAM
AS PER SBD
7 documents required · 7 mandatory
₹1,000
Executive Engineer, ED Budgam, KPDCL
₹27,000
25 Aug 2021
2 Aug 2021
19 Aug 2021
2 Aug 2021
18 Aug 2021
5 Aug 2021
2 Aug 2021 - 5 Aug 2021
Amount
Work items identified;
Dismantling, erection, testing and commisioning of 11/0.433KV, 3-phase Distribution Transformers 100 kVA / 63 kVA complete in all respect as per REC Standard. (Available at site).
Supply, Carraige upto site, erection,testing and commisioning of 9mtr long Steel Tubular Poles complete with base plate(300x300x5mm), top cap, including digging of pit (1/6th of pole height) positioning etc, complete in all respect as per REC Standard.
Supply, Carraige upto site, erection,testing and commisioning of 8 mtr long Steel Tubular Poles complete with base plate(300x300x5mm), top cap, including digging of pit (1/6th of pole height) positioning etc, complete in all respect as per REC Standard.
Supply, Carraige upto site, laying, stringing, tensioning, binding of 50 Sqmm ACSR Conductor complete in all respects as per REC standards.
Supply, Carraige upto site, laying, stringing, tensioning, binding of 30 Sqmm ACSR Conductor complete in all respects as per REC standards.
Supply,Carraige upto site and fixing of GI V Cross arm & GI F Top with clamps duly fabricated as per site requirement including clamps(50x6 mm), GI Nuts & Bolts,washers etc complete in all respects as per REC standards.
Supply,Carraige upto site, fixing and installation of GI Channels of different sizes including clamps and braces.
Supply,Carraige upto site,Installation,testing and Commissioning of 11 kV porecelain composite Disc Insulators 12 kV Min. failing load 45kN, Lighting impulse 75 KV positive and 80 KV negative, Creepage distance 320mm complete in all respects as per REC standards
Supply,Carraige upto site,Installation,testing and Commissioning of 11 KV porecelain composite Pin Insulators 12 kv.5KN, Lighting impulse 75 Kv positive and 80 Kv negative, Creepage distance 320mm complete in all respects as per REC standards
Supply, Carraige upto site, installation, testing and Commissioning of Gapless Surge Arrestor 9 kV, 10 kA, LA with polymer housing, Stn. Type complete in all respects as per REC standards.
Supply, Carraige upto site, installation, testing and Commissioning of 11 kV G.O AB Switch 3-phase, 3pole 200-Amp, vertical Type with fittings complete in all respects as per REC standards.
Supply, Carraige upto site, installation, testing and Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A complete in all respects as per REC standards.
Supply, Carraige upto site, laying, stringing, tensioning, binding of 1.1 KV grade, 1-core 185 Sqmm PVC Conductor FRLS type complete in all respects as per REC standards
Supply,Carraige upto site, fixing of Aluminium Thimbles of size 185 Sqmm.
Supply,Carraige upto site, fixing and Commissioning of Aluminium Solderless Clamps of size 185 Sqmm.
Supply, Carraige upto site, installation, testing and Commissioning of LT Fuse Unit complete in all respects as per standards
Earthing of substation-Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 75 mmx10 mm, 50 mmx6 mm for connection of transformer body & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply,Carraige upto site and installation of GI Mukhi Clamp for Shackle insulators.
Supply,Carraige upto site and installation of 16KN Shackle insulators.
Cement bottoming of S T poles in 1:2:4 mix,up to 1/6th plantation depth of pole below ground, 9" above ground,circular with radius 6" around the pole girth/surface ,top surface tappered outwards 0.5 cum/pole as per the diagram given in technical specifications.
Earthing of steel tubular poles complete by GI pipe 40mm or GI rod 20mm 2.5mtr long through GI strip.
Painting of Poles with one coat of Red Oxide (1ltr/pole) and two coats of alimunium paint (1ltr/pole).
NOTE: 1.The rates quoted by the bidder for all the items shall be inclusive of GST/freight/insurance/storage/installation/testing and any other charges FOR Shifting of Electrical Lines and transformers from the alignment of PMGSY road from L036-T01 Km 3rd to Naupora via villages of Chek-Kawoosa, Kawoosa Khalisa and Naupora Stage U, Package No. JK02-114, Block- Narbal, Budgam under the jurisdiction of ED Budgam_ KPDCL.
M/S AL-MUSTAFFA ELECTRICAL
A One Engineers
M/S G E C ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .