Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.9 L+₹1.3 L (5.40%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹17.8 L
EMD Value
₹35,000
Closing Date
15 Jan 2020, 5:00 pmClosed
XEN Electrical Divn No.II
XEN Electrical Division No.II HPPWD Shimla-2
Providing electrical installation
2019_PWD_33632_1
ED.II.GA.Tender/19-20-6977-78 dated 18.12.19
Open Tender
Electrical Works
Item Rate
365 days
District Shimla
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
EE Electrical Division No.II
₹35,000
6 Jul 2020
27 Dec 2019
16 Jan 2020
27 Dec 2019
15 Jan 2020
27 Dec 2019
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group C.
Light Point.
Fan Point.
Call Bell Point.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. piano type switch and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
Group C.
Wiring for power plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.S. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x2.5 Sq. mm.
Wiring for circuit/sub-main with 4x2.5 sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No 2.5sqmmm (4x2.5+2x2.5).HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
4x 2.5 sq mm
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x10 Sq. mm.
Supplying and fixing metal box of 100mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, painting etc. as required.
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Single pole.6 Amps Cat-A.
Single pole.16 Amps Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
MCB DP 40\50\63 Amp
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.
RCCB40 Amps. Cat-A.
RCCB63 Amps. Cat-A
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-12 way
Providing and fixing TP&N switch disconnector fuse unit panel mounting, 415/500 volts with 3 No. HBC/HRC fuses, open execution, including drilling holes in the cubical, making connections, etc. as required.
63 Amp. Category-A. In sheet steel enclosure.
100 Amp. Category-A
200 Amp. Category-A
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation, made from 1.6 mm thick M.S. sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding Each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall have cable entry box at one or two sides, with epoxy powder coated approved paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-
300 mm deep (nominal)
Supplying and fixing copper strip bus-bars suitable for 100 Amp. 415 volts capacity 4 No. Each of cross-sectional area (25.4mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. Each of cross-sectional area (25.4mmx4.75mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and erection of wall mounted metal boards for switch gear mounting of suitable size, with permissible variation in size of plus minus 5mm, welded frame work made of M.S. angle iron 35 mm x 35 mm x 6 mm thick duly welded complete with 2.80mm thick M.S. sheet fixed with hinges as open able front, complete with locking arrangement including painting and bonding to the existing earth as required:-
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and laying earth connections from earth electrode with 6 SWG (4 mm dia.) copper Wire in 15 mm dia. G.I. pipe from earth electrode etc. as required.
Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub-main wiring/cable as required.
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:-
Armoured cable 6 sq. mm (twin core)
Armoured cable 50 sq. mm (3.5 core)
Providing and laying of one no aluminium conductor PVC insulated PVC sheathed UnArrmourd xLPE power cable working voltage 1100 volts grade on Surface etc of the required Size
Armoured cable 6 sq. mm (twin core)
Armoured cable 10 sq. mm (four core)
Armoured cable 50 sq. mm (3.5 core)
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required. Make:- Bajaj, Crompton, Havells or any other approved by Engineer-in-Charge.
Exhaust Fan,Light Duty (Domestic) 300 mm sweep
Exhaust Fan,Heavy Duty (Domestic) 300 mm sweep
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:-
25 Liter capacity water heater (Cat-A)
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required. Make:- Usha, Bajaj, Crompton or any other approved by Engineer-in-Charge.
Ceiling Fan 1200 mm sweep. 5 Star rating.
Supplying and erection of street light bracket made of G.I. pipe 'A' class of suitable length and dia, the pipe bended to give an angle of 100 to 110 degree fitted with bolt & nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over priming coat complete in all respects as required:-
32 mm dia. G.I. pipe, heavy class
Providing and installation of following type of ultra slim decorative LED batten with two years warranty with extruded aluminium heat sink,with anti glare polycarbonate diffuser and energy efficient constant current integral,electronic driver,suitable for input voltage:AC 220-240 V,50/60Hz,complete with all accessories,including mounting clips & loop in loop out wire,connections,testing and commissioning etc.as required.Make:Philips,Twinkle,GE or any other approved by Engineer-in-Charge.
LED Batten Light 20 W 1200mm
Providing, Installation,of following type of LED SLEEK surface mounted square downlight with polycarbonate body and aluminium heat sink,suitable for input voltage:AC 220-240 V,50/60Hz,including mounting the fixture,testing etc.as required complete in all respects witht two year warranty. Make:Philips,Twinkle,GE or any other approved by Engineer-in-Charge.
Sleek Surface 6 WH SQ 6 watt.LED
Providing and installation of following type of Surface mounting Square type LED Panel Light , powder coated housing made of CRCA sheet, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including making connections, testing and commissioning etc. as required. Make: Twinkle, GE, Philips or any other approved by Engineer-in-Charge.
LED Panel Light 36 Watt. ( Size : - 1' x 1' )
Supplying and fixing of Recess / Surface mounting LED 2' X 2' Luminaire, white powder coated CRCA housing with highpower LEDs. Aluminium front frame with flat white high transmission acrylic cover. Complete with all accessories including making connections, testing etc. to the best satisfaction of Engineer-in-Charge as required. Make:- Philips, Syska, GE or any other approved by Engineer-in-Charge.
LED Panel 2' X 2' luminaire 36 watt.
Supplying and fixing electrical switchboard having 3 Nos. of 5 Amp.switches and sockets on suitable size of metal box of 200mmX150mmX75mm deep (Nominal size) on surface or in recess with suitable size phenolic laminated sheet cover in the front vi/c providing and fixing 3 Nos.5 pin 5/6 Amp.socket outlet and 5/6 Amp.piano type switch,connections,painting etc.as reqd.(For light plugs)
Supplying and erection of Galvanized Iron (G.I.) pipe pole 'A' quality of suitable length and dia. 4.47 mm thickness, including fixing up to a given depth below G/L.The hole of excavation about 30 cm dia. and given depth to be filled in up to 15 cm below G/L with 1:3:6 cement concrete and there above plinth with 1:2:4 cement concrete up to a height of 45 cm from G/L. The radial thickness of the plinth above G/L should not be less than 6.35 cm and sufficient to completely flush a 180 mmx100 mmx 45 mm deep, glass filled Nylan F.R. grade box for housing a 16 Amp. MCB, the outer surface of the plinth to be finished with 1:3 cement plaster 6 mm thick, the fuse-box shall have a water tight cover, including painting of pole with two coats of approved color, brand and manufacture of paint over a priming coat complete in all respects as required:-
4 Meter long having nominal bore dia. 65 mm planting depth 80 cm with pit depth 95 cm.
Providing and installation of following type of pole mounting LED luminaire with minimum 2 years warranty with pressure die cast housing with epoxy power coated dark graphite gray colour finish.Prismatic polycarbonate cover with individual LED lenses and seprated energy efficient constant current,non-integral,electronic driver,suitable for input voltage:AC 220-240 V,50/60Hz,complete with all accessories,connections,testing and commissioning etc.as required.Make:PhilipsTwinkle,GE or any other approved by Engineer-in-Charge.
LED 45 watt.
Supply instalation testing and commissioning of wall mounted pannel of suitable dimension made frome 1.6mmthick CRCA sheet complete with BMCCM 100Amp spreader links copper busbar100Amp and provisions for MCBDB 16 Way Each phase double door LED phase incldicating set as reqd complete in all respects as approved by Engineer-incharge
Wall Mounted pannel 100 Amp
Supply instalation testing and commissioning of wall mounted pannel of suitable dimension made frome 1.6mmthick CRCA sheet complete with BMCCM 100Amp spreader links copper busbar100Amp and provisions for MCBDB 16 Way Each phase double door LED phase incldicating set as reqd complete in all respects as approved by Engineer-incharge
Wall Mounted pannel 200Amp
D.S Ranta Electrical Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_48469.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .