Loading…
Loading…
Tender Value
₹66.0 Cr
EMD Value
₹1.3 Cr
Closing Date
30 Jun 2026, 12:00 pm
Composite work for Creation of Advance maintenance facilities of Electric Loco for catering Zonal as well as foreign Railways locomotives at ELS/Tatanagar, Creation of Trip Shed for Trip inspection & maintenance activity of Electric locomotives at ELS/Tatanagar and Creation of Advance maintenance facilities for Electric locos at CTRC/Tatanagar under jurisdiction of Dy Chief Engineer (Con), Tatanagar.
4642-GRC-CE-C-II-25-2026
4642-GRC-CE-C-II-25-2026
Open
24 Months
East Singhbum, Jharkhand
₹0
₹1.3 Cr
2 Jun 2026
2 Jun 2026
16 Jun 2026
Item Breakup - A-Execution of all work as per schedule
cum SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Earthwork in cutting in formation, trolley refuges, side drains, level crossing approaches, platforms, catch water drains, diversion of nallah & finishing to required dimension and slopes to obtain a neat appearance to standard profile inclusive of all labour, materials, plant & machinery, leading all cut spoils either to make spoil dumps or for filling in embankment with leads within 2 km on either side of edge of the cutting(s) including all lifts, ascent, descent, loading, unloading, bailing & pumping out water, if required, clearance of site and all other works incidental thereto for completing the work as per RDSO Specification No. RDSO/2020/GE: IRS-0004 with latest updated correction slips and to the satisfaction of the Engineer-in- Charge. Note: (i) All usable earth arising from cut spoils shall be led into bank formation and Unusable spoils shall be dumped / stacked away from toe of embankment. (ii) All hard rock /and boulders not fit for filling will be stacked by the contractor and will be property of the Railways. (iii)Cut trees shall be property of Railways and to be deposited in the railway godown unless specified otherwise in the Conditions of Contract.
55020.00 except rock
cum Metallizing of steel work of girders with sprayed aluminium after surface preparation by Sand/grit blasting, followed by one coat of etch primer (IS:5666) & one coat of Zinc Chrome primer (IS:104) and two coats of aluminium paint (IS:2339) with all labour, T&P and material as a complete job duly conforming to all relevant specifications and process given under Clause 39 of IRS-B1-2001. Note: Nominal Thickness of sprayed Aluminium coating shall be 150 microns. DFT of Zinc chrome primer shall be 25-30 microns and DFT of each coat of Aluminium paint shall be 12-14 microns.
Item Breakup - B-Execution of all work as per schedule
Item Breakup - C-Execution of all work as per schedule
1.00 with rails & wooden/ST sleepers including leading the dismantled Buffer stop materials to nominated places within station yard limits and stacking as material-wise and classification-wise duly releasing all fittings carefully without causing any damage with all contractor's labour, tools, with all lead and lifts, crossing of tracks if any, etc., complete as directed by the Engineer-in-charge. Laying and linking of turnouts of all types including diamond crossings & Derailing switches with 52Kg / 60Kg rail section on PSC sleepers on prepared ballast bed for New lines or during total closure of section at indicated location as per standard drawing, duly leading sleepers, rails, switches, crossings, fastenings including rail cutting, drilling, fixing of all components, fittings with housing of tongue rails as per requirement of signaling, preparing ballast bed, filling and spreading of ballast as required, linking of turnout with track, attending track parameters including lifting, providing one round of packing to make track fit for 20 kmph speed including lubrication of fittings/fastenings, complete as directed by Engineer in-charge.
Set SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
2500.00 procedure prescribed in latest edition of IRPWM including cess dressing on both sides of track. The work will include removing excess ballast from track and putting the same in crib and shoulder by leading to a maximum of 50m including crossing of track, deweeding on ballast section etc and as directed by Engineer-In charge. Manufacturing, supply and stacking of machine crushed Track Ballast conforming to RDSO Specification (IRS-GE-1) with latest correction slips at Railway depot or nominated location. Note: Distance of nearest quarry mentioned in each sub-item is only for the purpose of selecting the items for preparation of estimates/tender schedule, based on the minimum distance between nearest quarry and centre of supply points and will not affect the selection of quarry during physical supply in any way till prescribed specification is met fully.
1900.00 40 km and up to 50 km
5000.00 50 km and up to 100 km 25mm gap Cess Welding and finishing of weld to meet the prescribed tolerances and pass all stipulated tests with Contractor's labour, materials, consumables, tools, equipments etc. to complete the work in all respect as per IR's "Manual for Fusion Welding of Rails by Alumino - Thermic Process" with latest correction slips, including all required handling and rehandling of rails, marking of welded joint, painting weld collar with anticorrosive paint, as directed by Engineer in charge. Note: 1. Welding shall be carried out only by trained welder having valid competency certificate using RDSO approved Alumino Thermit Welding Portions, 3 piece prefabricated mould (Zircon washed) manually pressed, Single shot crucible fitted with auto tapping thimble and Compressed Air Petrol/LPG preheating technique as per RDSO Specification No IRST/19-2020 with latest amendment. 2. Hydraulic Weld trimmer shall be used for chipping and profile Grinder for finishing.
1100.00 structure, removing rails, sleepers, fish plates, cutting of rails, segregation and stacking of released Rails, Sleepers and fitting at nominated location in countable manner within a free lead of 500m, levelling of ballast to correct profile for laying new track over it, all as per direction of Engineer-in-Charge.
6900.00 available along formation on top or at cess, in required uniform thickness, compaction of ballast layer laid on new formation at all the locations with smooth wheeled power roller of 8-10 tonne capacity to sufficient number of passes to form consolidated ballast bed of approximately 250mm thickness to a width of 4m symmetrical to centre line of proposed track in correct line & level with all ascents & descents, as directed by Engineer in-charge. Note: Item is inclusive of (a) providing ramp for taking roller to formation and removing the same & making good formation after completion of work; (b) redistribution & leveling of excess ballast while rolling to obtain uniform plane cambered surface. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Linking of BG track (except at LC, Bridges and SEJs) with any type of rail section and sleeper of specified density, on ballast bed spread and compacted with suitable roller, over prepared formation including leading free rails/welded panels available along the alignment on to formation, leading and spreading all fittings and fastenings, spreading of sleepers at specified spacing, squaring, placing of rails over sleepers and fixing rails to sleepers with all types of fittings and fastenings to correct gauge & alignment, lubrication of fittings and fastenings with contractor's grease as per IRPWM standards with contractors labour, tools, consumables, with all lead, lifts etc. complete and raising, levelling and initial packing of track to make it fit for 30 kmph and meet other prerequisites prescribed in Indian Railway Track Machine Manual for deployment of Tamping Machine. Note: 1.Rail cutting and Hole drilling shall be paid separately. 2.Spreading of ballast and compaction shall be paid separately under relevant item.
TRM Shifting / Slewing the existing or newly assembled track of any rail section with any type of sleepers and any density under line block to correct locations & alignment and attending to one round kutcha packing to run safely at 20KMPH speed with all contractors tools and consumables complete and as directed by Engineer in-charge.
TRM First or Second Through Packing of track of all sleeper density including giving a general lift, as desired to eliminate sag after Deep Screening work, lifting of track, lowering of track and major realignment of curves and formation rehabilitation as per procedure prescribed in latest edition of IRPWM. Note: General lift is normally 25 mm and isolated lift may be up to 50 mm.
2500.00 1540 Third or subsequent Through Packing of track for all sleeper density including picking of slacks, as required after second through packing, subsequent to Deep Screening work as per procedure prescribed in latest edition of IRPWM. This item can also be used after lifting/regrading/realignment works also. Note: General lift is normally 25 mm and isolated lift may be up to 50 mm.
2500.00 1540 Through packing of points and crossings, derailing switches including gauging, fittings recoupment, ballasting as required, elimination of sag and to the required alignment after Deep Screening as per procedure prescribed in latest edition of IRPWM complete as per direction of Engineer- in-charge. Note: This work shall be operated in exceptional cases with written approval at DEN level when UNIMAT is not available and immediate packing is required to pass train over it.
Set SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
11.00 joints of 3 pairs, measuring 6.5m each, duly removing rails of the existing track including cutting & drilling of rails as required for isolating LWR/CWR on all types of track structure. Work will be done under traffic block condition. Note: 1.Each set comprises of 3 pairs of rails 6.5 m long only. 2.Only Rails fish plate and fish bolts will be supplied free by Railway within free lead of 250m. Maintenance of track on main line & loops, Points & crossings etc. including special attention to section for carrying out various maintenance works listed in Indian Railways P.Way Manual / Bridge Manual for safe running of goods and passenger trains with contractor's tools / labours etc. complete, as directed by Engineer in-charge. Note: Contractor shall arrange one gang at any point of time comprising of minimum specified labours with sufficient experience in P.Way working.
180.00 fit labours plus 1 Mate. Note: (1) In case, contractor provides less no. of Labour/Mate or for non availability of vehicle, payment will be d e d u c t e d for each such person or non- availability of vehicle @ 20% of the accepted item rate, separately for each shortfall. (2) The Contractor shall keep one pick up Truck of minimum 1.5T payload capacity with Driver all the time and all expenditures for running at an average of 80 kms per day shall be born by the Contractor.
200.00 including disposing of muck beyond Railway boundary as per instructions of Engineer in- charge to keep drains clean and clear in cuttings etc.
200.00 and cess up to 3.95m from centre line of track in mid section & station yard, as specified by Engineer in-charge including disposal of branches, bushes outside cess/yard. Anti-corrosive painting of rail outside track on rail bottom, web, foot and fishing plane with two coats of thickness of 100 microns each by bituminous black paint confirms to IS-9862 of reputed make including surface preparation, as a complete job as per procedure prescribed in latest edition of IRPWM.
200.00 Thermit welded rail joints on track or on cess for new welded joints to protect against normal corrosion for any rail section with two coats of ready mixed bituminous black paint of reputed make confirming to latest IS:9862 on welded area up to 10cm on either side including on the underside of rail foot by brush including surface preparation as per Railway's AT Weld Manual including lettering / weld numbering with approved enamel paint as directed Note: Before painting, dust, loose rust and mill scale and dirt shall be removed thoroughly by wire brushing. Scrubbing welded area with water to make it free from slag and other water soluble compounds to make it dry. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Marking, inscribing, painting, writing, bordering etc. on new / old iron surface at various locations of Points & Crossings with details of turn-in / turn-out reference station mark on rail web for one set, duly preparing surface with contractor's wire brush and applying two coats of yellow synthetic enamel paint of approved quality as background and stenciling the details to suitable size, as described for every curve reference station mark / switch / crossing details with black enamel paint of approved quality complete, as directed : Note: Stenciling of letters is only p e r m i t t e d . No hand written letters are accepted.
Set Quick cutting with abrasive rail cutter of all types of rail sections including wear resistant, head hardened rails up to 110 UTS, with contractors tools & plants, equipment, consumable with all lead & lift etc. complete as directed by Engineer in-charge. Abrasive Rail Cutter will be as per RDSO Specification No. TM/SM/1 (Rev. 01 of 2012) with latest status of RDSO; Rail Cutting Wheel Abrasive Disc will be as per RDSO Specification No.TM/SM/2 (Rev. 01 of 2020)
Each Drilling holes of 16 mm to 32 mm dia. with Rail Drilling machine including chamfering with appropriate chamfering tools in all types of rail section with contractor's tools & plants, equipment, consumable with all lead & lift etc. complete, as directed by Engineer in-charge. Rail Drilling Machine will be as per RDSO Specification No. TM/SM/3, dated 24.04.1991.
Each Loading, leading and unloading of all types of P.Way fittings and all other miscellaneous m a t e r i a l except Rails, sleepers, switches, crossings, SEJs and Glued Joints by road vehicles for different leads. Note: Lead shall be the shortest motorable road length between the points of loading and unloading.
1000.00 over item no. 172047 Transportation of Rails, sleepers, switches, crossings, SEJs and Glued Joints by road vehicles for different leads. Note: 1. Lead shall be the shortest motorable road length between the points of loading and unloading. 2. Loading and unloading shall be paid extra under relevant items.
3000.00 over item no. 172057 SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Unloading of Switches / Crossings / SEJ Rails / Glued Joints of any rail section and length with or without P.Way fittings & fastenings in neat manner for Railway usage from departmental material train (DMT) or contractor's / Railway's Truck/Trailer with lead up to 250 metre & lift up to 5 metres.
MT Collection, segregation and stacking of various scattered P.Way materials at nominated stacking location with serviceable and un- serviceable ones separately within a lead up to 500 metre and lift up to 5 metre including crossing of track(s) wherever necessary as directed by Engineer-in-Charge.
700.00 Check Rails etc.
50.00 loose items
10.00 concrete Fouling Mark as per approved drawing at station yard, duly painting the top surface and slopes with white enamel paint in two coats and inscribed letters with black of Fouling Mark, complete in all respects with all labour, materials including cement, tools and plants etc.
1.00 Railway supplied rails, cutting, including bending of rails as per plan ,with all contractor's labour, materials, tools, plants etc. and all lead and lift including crossing of track where necessary and as directed by Engineer in charge at site. Note: Excavation, fixing rails in cement concrete, drilling of holes will be paid separately. Total 18859153.81
Item Breakup - D-Execution of all work as per schedule
Levelling the undulations and dressing Sqm formation in bank and cutting, before linking the track with watering,ramming,by rolling with contractor's vibrator roller of minimum capacity 10 tones and with minimum 8 passes to make the surface even and bring to the shape with camber of 1 in 30 as directed by the engineer-in-charge at site.NOTE : The operation of this item will bw at the disretion of the engineer-in-charge according to the requirement.
spreading of ballast in two stages i.e (a) on the cum formation before laying the track and (b) in the track and points and crossings,with contractor's labour, with lead up to 70m,as directed by engineer-in-charge. No extra payment will be made for crossing of railway lines. Note: No separate of ballast stacks will be given.The measurement for spreading of ballast to the supplier of ballast shall be considered for payment of spreading. Lead beyond 70m free lead shall be paid separately vide Schedule for SOR items only for yard portion. No additional lead will be paid for new formation for spreading ballast. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Rolling of ballast full width of ballast section cum with suitable type of vibratory roller to obtain a compact and uniform level surface of ballast for about four meter wide, including removing and redistributing ballast, already spread on formation to obtain a uniform level surface etc. complete.
Supply of unskilled labour for fixing and fitting Each of liners, G.R. Pads , ERC etc with contractor's grease/oil etc as directed by Engineer in charge at site for existing laid track to recoup fittings and also to assist site work during N.I. working.
Printing letter plain up to 150 mm height with Each tenderers paint of approved quality as and when required and as directed by Engineer-In- Charge inclusive of all taxes levies , manpower, taxes,Royalty etc.
Fixing of Railway & apos;s SGCI insert with Per proper alignment at guage and level as Sleeper specified in Indian Railway's P. Way manual including all lead, lift, ascent descent and contractor's labour, tools and plants complete required.
Supplying and fixing of plate screws (T-3912 Numbers for Points and Crossing, T-3913 for L-xing, C.I. Bracket for curve etc) with single coil spring wash.
Supply and fixing of hand point lever box as Set per relevant drawing.
Supply of small fittings like screws, different Kg sizes bolts, CI distance bracket(T- 4785),packing pieces, MS plates, fish plates,point lever box with pullover rods and other small fittings from RDSO approved farms as desired by Engineer-In-Charge. Total 2574990.00
Item Breakup - E-Execution of all work as per schedule
20mm thick heavy duty flooring with one part Sqm of stalemite/bromit/hardonite or any other metal floor hardner of approved quality and four parts of cement by weight initially mixed in dry condition to 2 parts (by bulk) of approved stone chips (6 mm sieve(s) down (free from dirt) confirming to IS: 383 - 1970 and to a smooth finish with a steel trowels. The rate includes supplying, erecting, fixing, dismantling, removal of wood or steel form work with all labour and materials of the contractor. Cost of cement shall be paid separately.
Supply fabrication and fixing 6 to 8 mm thick MT MS chequered plate as covering of cable trench with necessary rigid frame work by welding of MS angle and making lifting arrangement of cover plate as per approved drawing and as directed by Engineer-incharge. The rate includes a coat of painting by red oxide as primer and a coat of enamel paint. The payment will be made as per actual weight of chequered plate &MS angle frame. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Customized superior quality woodwork with ply Square Board (19 mm/12mm/6 mm Green ply Marino Foot brand or similar), battens, laminates (green ply , century or similar) MDF board louvers ,partions ,TV units ,Beds ( with back side padding),side tables, wardrobes, dressing units ,modular kitchen etc with all superior quality hardware all complete as per direction of Engineer in-charge or his representative as per approved interior design ,drawing etc. with all contractor materials, carpenter ,labours ,lead lift etc. complete.
Supply, supervision of GeoSynthetic Cementitious composite mat (FlexibleConcrete impregnatedfabric hardens when hydrated to form a thindurable concrete matt)thickness minimum 9mm. The Geo Synthetic Cementitious compositemat should have tensile strength of 20 kN/m forboth Longitudinal &Transversal as per EN-10319, Static Puncture Resistance - 3500(CBR) (N) as per EN12236, Elongation at Break - 40 % for both Longitudinal &Transversal as per EN10319, Compressive strength - 40 MPa asper ASTM C 109 -2, Fire Resistance-B-s1,d0. The Geo Synthetic Cementitious Composite matt shall be a CE certified product and shall be laid in catch water drains, Line drains, side drains etc.for construction of longitudinal drain between tracks and road length, slope protection/stability &covering RUBs during Launching as per approved drawings. Thework involves laying of Geo Synthetic Cementitious composite matt as per specification and methodology mentioned in the respective product literature in proper way with all required fixtures and fastenings/Anchors as acomplete job as per instruction and satisfaction of Engineer-in-charge with contractors own material, labour, with all lead, lift, Tool & Plantsetc. The design and methodology to be approved by Railway prior to commencement of work. The quotedrate also includes cost of all materials,transportation and supply at site,installation, fixing,pegging, curing, pre- installation, surface preparation work like Jungle cleaning,removal of fencing asper site requirement,ballast removal, stakingand spreading if required, surface dressing, soil profiling,earth excavation for drain and other miscellaneous petty work involved,back filling and surface finishing etc. completein all respect nothing shall be paid separately.Overlapping of 100 mmwill be provided between two conjugative Geosynthetic Cementitious composite matt. The overlap quantity shall be taken for measurement. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
"Providing and installing factory made, heavy cum duty, RCC interlocked Precast Concrete U shaed drain with internal dimension 300 mm X 750 mm and 100 mm thickness of wall , with provisions of vertical slit/open slit of size 450 mm height and 40 mm width at 250 mm c/c spacing , which is 150mm above the top of drain floor. The drain shall be of M 30 grade concrete (cement content 320 kg) including reinforcement Fe500 Grade or HD Wire of IS432 Part II, OPC 53 Grade Cement and to withstand heavy duty, providing shear keys, connecting loops, dowel tubes and proper lifting accessories for drain, manufactured in controlled factory environment with approved methodology including drain mould, mixing, transporting and placing of concrete, vibrating, steam curing, smooth finishing, making necessary cutout/holes of required sizes for services, yard handling & stacking all complete as per IS 11447:1985 and as per approved drawings and design mix as per the direction of Engineer-in-Charge . Install to correct alignment , which is required as per site condition. This cost includes loading, transpoartation , loading, stacking and installation Note: Excess over the specified cement content used as per design mix is payable)." Total 15684562.60
Item Breakup - F-Execution of all work as per schedule
Preparation of Design & drawaing for New Sqm office building & other buildings (Should be as per latest circular). Notes: (i) The contractor will carryout detailed survey and prepare GAD and get it approved from Railway. (ii) The rates are inclusive of visits to site if required. The site of the work falls under the jurisdiction of Dy.CE (Con), TATA. (iii) The above quantities are approximate. The Railway reserves the right to increase/decrease the same. Additional special conditions of contract: i) The Agency will get the design checked from Railway. For this purpose Agency will ensure the presence of his representative in the offices of Railway authorities whenever required. Nothing extra will be payable for theabove and the rate is inclusive of above. ii) After drawing got approved by Railway, the Agency will have to submit three copies of initial design calculations with 3 ferro copies of drawings to Railway for record. Design calculation should be clearly written and bound in book form. iii) On clearance of design criteria from Railway for any modification, agency will carry out detailed design again as required without any loss of time after clearance of design parameters. He will also be prompt in clarifying the observations/doubts of the Railways. No extra payment shall be made for the any alterations. iv) Design and drawing after approval shall be property of S. E. Railway who shall have exclusive right to use or reuse it elsewhere. The consultant shall have no claim whatsoever in this regards. v) Based on the design note approved by Rly, the Agency will prepare final general arrangement drawing. Mode of payment: i) Visit to site and collection of field data from site, and detailed design of and preparation of GAD, submission to Railway 3 sets of GAD (Ferro copy), design calculation 3 booklet = 20%. ii) After acceptance of Railway = 50%. iii) Final submission of drawing approved in item (ii) above in reproducing tracing films 3 copies and soft copy on CD, 3 sets of ferro prints for each drawings, final design calculation booklet. Payment will be made after signature of Railway authorities in final drawing =30%. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
A.Rate taken from NIT Rourkela for Proof Numbers checking of Drawing & Design fromIIT/NIT or Any Govt. College/University. The Rate chartfor the Proof Checking/Vetting of structural designand drawings as follows: (i)Estimated project cost lessthan or equal to 2.0 Cr. -cost@ Rs 0.40(lakh), (ii)Estimated project cost 2.0-5.0 Cr. - cost @ Rs.0.95(lakh), (iii) Estimatedproject cost 5.0-7.5 Cr.-cost@ Rs. 1.35(lakh) (iv)Estimated project cost 7.5-10.0 Cr. - Cost @Rs. 1.70(lakh) (v) Estimated projectcost 10.0-12.5 Cr.-cost @ Rs.2.00 (lakh) (vi) Estimatedproject cost 12.5-15.0 Cr.-cost @ Rs. 2.25 (lakh) (vii)Estimated project cost 15.0- 17.5 Cr.-cost @ Rs. 2@46>40@lakh) (viii) Estimated projectcost 17.5-20.0 Cr.-cost @ Rs.3.00 (lakh).The above feesare as per the estimatedproject cost range, and thementioned rates areexcluding 18% GST butincluding the instituteoverhead. B.Rate taken fromNIT Jamshedpur for Proofchecking of Drawing & Designfrom IIT/NIT or Any Govt.College /University. Lumpsum rate for checking/vettingof the Design and Drawing ofRCC structures (Buildingworks, Water tanks),culverts, RCC & PSC Bridges,Pedestrian Bridges, SteelTruss, Steel Buildings. (i)Estimated Cost of theDesigned structures Lessthan 0.50 Cr.-cost @ Rs.20000.00(ii) Estimated Costof the Designed structures0.5 - 1.0 Cr.-cost @ Rs.30000.00 (iii) Estimated Costof the Designed structures1.0 - 2.0 Cr.- cost @ Rs.40000.00 (iv) Estimated Costof the Designed structures2.0 - 5.0 Cr.-cost @ Rs.60000.00 (v) Estimated Costof the Designed structures5.0-7.5 Cr.-cost @ Rs.100000.00 (vi) EstimatedCost of the Designedstructures 7.5-10.0 Cr.-cost@ Rs. 125000.00 (vii)Estimated Cost of theDesigned structures 10.0-12.5 Cr.-cost @ Rs.175000.00 (viii) EstimatedCost of the Designedstructures 12.5-15.0 Cr.-cost @ Rs. 225000.00 (ix)Estimated Cost of theDesigned structures 15.0-20.0 Cr.-cost @ Rs.300000.00 (x) EstimatedCost of the Designedstructures More than 20.0Cr.-cost @ Rs. 0.2%estimated cost of designedstructures or decided byinvestigator(s) in consultationwith HOD. Notes: In specialcase, approval will be takenfrom the competentauthority. N. B.: i. In case ofnew consultancy if required,same shall be charged as perapproved rates at the time oftheir requirement. ii. Revisedrate of consultancy will notbe applied on on- goingproject. iii. In addition torespective testing chargesmentioned above, the servicetax, educational cess,government levies i.e. GST,Sale tax, Income Tax, Vatetc. (if imposed) asapplicable from time to timewill be charged extra. Total 396480.00
Item Breakup - G-Execution of all work as per schedule
20.00 Boulder at all levels
20.00 undisturbed samples of soil from bore holes, including provision of air tight containers for packing and, labeling incl. transporting the samples to laboratory. Piston sampler shall be used for extracting undisturbed samples where necessary. Samples shall be collected as per IS:2720.
20.00 disturbed samples of soil from bore holes, including provision of air tight containers for packing, labeling and transporting the samples to laboratory. Samples shall be collected as per IS:2720.
20.00 IS:2131 at approximate1.5m intervals in bore holes, as directed by the Engineer in charge Conducting laboratory Tests on collected soil samples as per relevant IS code
analysis analysis
Each Conducting Laboratory tests on collected ROCK SAMPLES as per relevant IS code
20.00 samples to determine suitability for concreting a n d aggressiveness in relation to attack on concrete / reinforcement including determination of pH value.
20.00 to determine aggressiveness in relation to attack on concrete / reinforcement including determination of pH value Total 808421.40
Item Breakup - H-Execution of all work as per schedule
Preparation of Yard plans by modification of Numbers existing plans and approval of the same from Railways and modification of the existing yard as per Additional track requirement/latest approved ESP/ master plan. Delivery in AUTOCAD format & Pdf format. Total 43467.68
Item Breakup - I-Execution of all work as per schedule
Wheel press (500T).
EOT crane 15 T/3T.
EOT crane 50 T/ 6T.
Transformer oil filtration capacity (Two stage).
Power Hacksaw Machine.
Pedestal grinder.
High pressure hot water steam jet cleaning Numbers plant.
Mig Mag Co2 IGBT based Inverter based Numbers welding machine with Co2 cylinder and Trolley.
EOT Crane 15 Ton Capacity.
CNC HORZ. BOARING AND MILLING MACHINE Numbers (Tooled Up).
TAN DELTA MACHINE.
ULTRASONIC FLAW DETECTOR MACHINE.
GROWLER TESTER.
TRACTION INSTRUMENT, CAPACITY- 37.5 KVA. Total 97985952.00
Item Breakup - J-Execution of all work as per schedule
Scissor Lift Capacity 400 kg.
Storage arrangement for Helical spring etc.
Hand Pallet Truck capacity 2.5 T.
Fork lift (electric) capacity - 5 T.
Wheel Transport vehicle Model TATA 1012 LPT Numbers DCR39FSD 125B6M5 BS-6 or similar.
Hydraulic Manual stacker capacity 1500 kg.
Scissor lift table capacity 1 T.
Hand pallet Truck capacity 4 T.
Breakdown CREWCABIN4X2 DIESEL BSVI CLB.
Battery operated Platform truck load capacity - Numbers 4 ton.
Motorized Motor transfer trolley 10T (width Numbers 2000mmx length 3000mm x height 500mm). Total 13616284.00
Item Breakup - K-Execution of all work as per schedule
MS LOCKER FOR TOOLS WITH 08 NOS BOX.
Set of Pneumatic impact wrenches size:- one Set inch, three quarter inch and half inch, each in one Qty.
Hydraulic crimping tool comprising of high Numbers speed hand operated hydraulic pump mounted on U frame. Max capable to crimp 50 sq.mm to 400 sq.mm. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Set of Portable electric impact wrenches Set Square drive size: - one inch- 2 Nos., Three Quarter inch-3 Nos. & half inch- 5 Nos.
Set of fitter tools containing 1/2 inch square Set drive L-Handle, 1/2 Inch square drive Ratchet handle, Chrome vanadium steel Allen key tip size 17 mm each in Qty. 1 No.
Set of spanners containing:- Box, Ring & D Set spanners as per annexure 50 set from each.
Supply and commissioning of complete set of Set hydraulic pump and jack including fixture as per DLW Drg. no. MS23EL0498 (pivot housing pressing arrangement in Bogie) for pressing elastic ring with housing of bogies of electric loco WAP7 with standby hand pump.
Submersible Pump Set single phase of 0.37 KW Numbers for pit dewatering.
Monoblock portable electric pump Set single Numbers phase of 0.75 KW.
Portable electric drills 600W.
Component & PCB Inspection System.
Portable electric angle grinder.
Soldering & De-soldering station with digital Numbers display.
Platform scale Weighing machine (Electronic 0- Numbers 5000kg).
Supply, installation & Commissioning of Numbers Automatic Digital Surge Comparison Tester (0- 10KV).
Aneomometer with built in indicator, Data Numbers logger & MODBUS RTU RS485 etc.
Thermo vision camera.
Electrode heating oven 350 Degree C.
500V Megger Insulation Tester Metal Body Numbers Hand Driven Generator Type with protection cover.
Hand Driven Generator Type Insulation Numbers Tester/Megger Analog type 1000 V Ohm with leads.
Insulation Tester (Megger) Hand Driven Numbers Generator Type Metal Body with HV testing leads of length 2m. Rating 2500 V. 2000 Mega- ohm with with calibration certificate and test certificate.
Digital Micro ohm meter with range 1 Micro Numbers ohm to 19.99 K ohms.
Digital clamp meter.
Shock pulse meter.
High Voltage Vacuum interrupter (VCB) Tester Numbers along with permanent cable set 5 mtr.
3.5 digit LCD display hand held true RMS Numbers clamp meter.
Three digit LCD display hand held true RMS Numbers clamp meter.
Handheld BRUSH CUTTER machine.
Chain Saw Machine Engine 2 stroke petrol Numbers operated.
Rumble 18000 CMH Air cooler.
Borewell with submersible pump fitting.
Sock Pulse Analyzer with balancing features. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Set of three points digital inside micrometer Set with setting (calibrating) ring and extension rod for each item, with wifi recording system, Range: (1) 50-70 mm, L.C.: 0.001mm, (2) 70 100 mm, L.C.: 0.001mm., (3) 100-150 mm, L.C.: 0.001mm., one set consist of three items. Make: Mitutoyo or Insize or ITI or Mahr or Starrett or BOWERS. Accepted Make/Brand: "INSIZE". Firm's Offer: Set of three points digital inside micrometer with setting (calibrating) ring and extension rod for each item, with Data Output Wireless Transmitter unit system with a eceiver(USB Port), Band width: 2.4GHz, Signal Range: 15 Mtrs. Range: (1) 50-70 mm, L.C.: 0.001mm. (2) 70-100 mm, L.C.: 0.001mm., (3) 100-150 mm, L.C.: 0.001mm., one set consist of three items.
Surge comparison Tester (0-10 KV). Total 12545966.00
Item Breakup - L-Execution of all work as per schedule
Supply of rolled or fabricated and galvanized Tonne traction mast/gantry mast and auxiliary transformer masts, Feeder mast.
Supply of TTC structures with boom.
Supply of fabricated and galvanized portals Tonne with boom.
Supply of fabricated and galvanized steel Tonne works other than traction mast, DA, Dwarf mast etc.
Supply of single cantilever assembly complete Each with insulator for conventional OHE and inside the tunnel.
Supply of guy rod assembly.
Supply of regulating equipment 3 pulley type Each complete with all accessories including counter weight assembly and SS wire rope for convention at OHE.
Supply of materials for termination of single Each conductor (including supply of cut-in insulator) of overhead equipment or a terminating wire.
Supply of materials for termination of double Each conductor (including supply of cut-in insulator) of overhead equipment.
Supply of overhead equipment excluding Kilometre catenary, contact, jumper and dropper wires (which will be supplied by Railways).
Supply of section insulator assembly including Each core and cut-in insulator.
S u p p l y of 25kV single interlocking mechanism.
Supply of platform).
Supply of Longitudinal bond.
Supply of Earth electrode.
Supply of MS flat for earth (50mmx6mm).
Supply of transverse, Cross and special bond.
Supply and erection of Retro reflective Caution Each board for 25KV AC traction in 3 language Hindi, English & Oriya.
Supply and erection of retroreflective Danger Each board for 25KV.
Supply and erection of Retro reflective type Each Unwired turn-out board. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply and erection of Retro reflective Public Each caution board in three language English, Hindi & Oriya.
Supply and erection of Shock treatment chart Each in two language.
Supply and erection of Retro reflective Electric Each engine stop board.
Supply and erection of Retro reflective type Each Power block working limit board.
Supply and erection of Sectioning diagram.
Supply and erection of Additional Retro Each reflective location number plate conforming to RDSO Spec.
Supply of 25KV solid core suspension insulator Each including material for suspension arrangement.
Supply of 25KV post insulator.
Supply and erection of Catenary and contact Each splice.
Supply of 18 mm solid copper busbar.
Supply of Copper Bus-bar connectors for 18mm bus-bar.
Supply of Bus splice for 18 mm Copper bus- Each bar.
Supply of multiple hole ( 19 mm ) bolted type Each terminal connector(1009).
Supply of Double pole Isolator with inter Numbers locking mechanism (1600 A). Total 26505361.50
Item Breakup - M-Execution of all work as per schedule
Supply of steel gantries/portals/Mast and MT supporting structures and small parts steel work for switching post.
Supply of 25 KV single pole Vaccum circuit Each breaker 2000A conforming to RDSO specification.
Supply of 25 KV single pole Vaccum interrupter Each conforming to RDSO specification.
S u p p l y of Fencing upright approved drg.
S u p p l y of Fencing pannel approved drg.
Supply of materials for termination of single Each conductor / cross feeder (FTA) with complete set.
Supply of ligntning Arrestor 42 KV rating for 25 Each KV side.
Supply of terminal board in control cubical.
Supply of 110V DC distribution board.
Supply of 230 V AC distribution board.
Supply of 25 KV PT type-I.
Supply of 25 KV PT type-II.
Supply of 25 kV Current transformer (3000- Each 1500/5A).
Supply of Al. Bus bar.
Supply of rigid bimetalic terminal Connector Each suitable for 50mm dia aluminium tubular busbar to terminal pad of 25 KV isolator/CT (ID- 11090).
Supply of Expansion type terminal Connector Each to suit 50mm dia Aluminium Tubular Busbar Terminal pad of 25KV CT/Isolator(ID 11060). SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Suply of 25KV system TEE connector to suit Each 50mm O/D Aluminium Tubular Busbar (ID- 11150).
Supply of Rigid Terminal on SI to suit 50mm Each O/D Aluminium Busbar (ID 11200).
Supply of Sliding Clamp for Aluminium Busbar (ID-11190).
Supply of 75mmx 8 mm mild steel flat.
S u p p l y o f Copper equipment earthing.
Supply & Erection of 8 SWG G.I. wire for Metre earthing.
S u p p l y of switchstation. Metre
Supply of 110 V, 200AH Lead Acid battery.
Supply of 110 V Lead Acid battery Charger Each (200AH).
Supply of anti climbing device for Auxiliary Each transformer.
Supply, erection , testing & commissioning of Each Remote station equipment for SSP as per latest RDSO specification.
Supply of control & relay panel board for the Each Protection of 01 CB & 2 Interruptors as per to RDSO's specification No.TI/SPC/PSI/Protect/6071.
Supply & erection of fire fighting equipment.
Supply & erection of First Aid Box. Total 8907830.00
Item Breakup - N-Execution of all work as per schedule
Supply of Feeder pillar box IP-56,plinty Set mounted type,3 phase and neutral,416V consisting of 4 Nos copper bus bar each 300A 1X250A MCCB 4-Pole (Adjustable Thermal & Adjustable Magnetic setting) as incoming and 3X100A MCCB 4-P250A,4Pole and 3X63A MCCB 4-P as per IS/IEC:60947-2,as outgoing &LED indication lamp in suitable size duly painted 2mm CRCA Steel sheets Enclosure with locking arrangement.
Supply of Wall mounted air circulator fan Numbers 750mm/600mm sweep,230V AC,complete with frame and all necessary assories.
Supply of 5/6 mtr long GI octagonal pole with Numbers all accessories as specified in Explanatory Note.
Supply of surface/flush mounted 12 Way Numbers vertical TP &N Distribution boards (MCCB I/C & 12+12+12 O/G module) with IP43 & IK 09 protection, single metal door with locking arrangements, with busbar, neutral link, Earth bar and DIN rail for provision of changeover switch, MCCBs , MCBs for incoming and distribution of power supply.
Supply of outdoor type LED light fitting(IP-66) Numbers for front lighting 70-80/90 watt suitable for voltage 230V AC complete with driver and all other accessories.
Supply of LED flood light luminaire 200W,240V Numbers for high mast application with LED light as light source with reflector of reputed mark & necessary accessories. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of LED Highbay fitting 150W along with Numbers excellent thermal management along with IP66 protection complete with electronics driver (SMPS based constant current supply) with Short Circuit,Over Voltage & Surge Protection and all other accessories.
Supply,testing of Occupancy Sensor working Numbers on PIR technology covering Micro motion & heavy motion Rated voltage 230V ± 10% ambient light 3 to 2000 Lux.Rated load - 2000watt (minimum) power consumption 0.5w (approx) detection range 360 degree with all necessary assories to complete the work in all respect including installation and commissioning.
Supply,testing of Occupancy Sensor working Numbers on PIR technology ABS cabinet of sensor,CRCA sheet Box 10'' X 12'' control panel with contactor 25A, metallic plug top and by pass MCB,rated voltage 220V-240V AC capacity- 3KW,recommended installation height 2-3 meters,maximum 6 meters,IP 20 protection,detection range 360degreewith all necessary assories to complete the work in all respect including installation and commissioning.
Supply of MCB 25A 10KA with 3/5 pin 15A Numbers modular type socket with starter in a enclosure for A.C. point similar to DHDUCDPO2530156- 25 with complete wiring.
Supply of Industrial type IP-67/66 power plug Numbers and socket,63A With complete unit;63A,416V,3P+N+E with provision for protection IP-67 with 63A, 4P MCB and one 20A (1PH+N+E) plug & socket with 16A DP MCB and 100A TPN connector with Enclosure.Power socket should be assembled in a Rain proof,high quality Thermoplastic Polycarbonate IP-66/67 dust & jet water proof,corroson,weather safe,acid and chemical resistant,fire retardant with internally embedded gasket box.
Supply of industrial type power socket 32A, Numbers 416V, SP+N+E with 32A TPN MCB with Enclosure (similar ti Havells model No.DHDPBEN032 of Feb-2023).
Supply of three phase Astronomical timer Numbers based street light panel suitable for 12 KW Max. load including 65A TP Contactor 63A TPN MCB (similar to Havells IHXTSO306A).
Supply Erection, fabrication & painting of MT Miscellaneous iron work MS angle, flats,channel required nut, bolts etc. for Iron fencing 2.5 m height with gate, Small steel parts except rail pole for Fabrication of cable tray/Cross arms channel/4pole/2 pole structures etc.
Supply of Earth electrode of 2.8 M long, 54.4 Numbers mm inside dia and 60.2 mm out side dia, thickness 2.9mm GI pipe.The pipe having conically tapered at one end and having sufficient no. of holes of 12mm dia.including connection by 2.8.No SWG GI wire and making of earth cone sump box.
Supply,installation,testing and commisioning Numbers of Maintenance free Earthing system comprising of 48.3mm dia.3 mtr long earthing electrode with 250 microns copper coating + carbon based conductive back fill compound & copper Clamp including suitable length earthing GI strip of 40x3mm with termination works. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of GI Flate of size 40mm x 3mm for Metre Earthing of all structure and vital equipment including required nut, bolts & sockets etc.
Supply of wire mesh type/Galvanised iron Metre cable tray of Stainless Steel, 2.5 mm thick 300mm width with SS fixing bracket,coupler & bend plat with suitable SS nut & washer etc.
Supply of 200A 50kA 4P MCCB with Sheet Numbers Steel Enclosure.
Supply of 40A 2P Adi type RCCB for AC + Numbers Pulsating DC (Type A) + Harmonics with 30mA Sensitivity with enclosure.
Supply of 63A 4P Adi type RCCB for AC + Numbers Pulsating DC (Type A) + Harmonics with 100/300mA Sensitivity with enclosure.
Supply of MS sheet cable Busbar Chamber of Numbers Sizes 9''X10''X3'' (approx) with 4 Nos Copper bus bar of 63A capacity each,all assembled in CRCA sheet, Enclosure (similar to Havells Cat.No.IHBC006304).
Supply & laying of Insulated rubber mat 1m x Numbers 1m x 2cm as per IS 15652;2006.
Supply 63A Capacity RCBO.
Supply of 100A 4 Pole 'C' Series MCCB.
Supply of 32A Capacity DP 'C' Series MCB.
Supply of 20A Capacity DP 'C' Series MCB.
Supply of 6A Capacity DP 'C' Series MCB.
Supply of water tight Weatherproof Enclosure Numbers of 4 Module.
Hot dip galvanized flange mounted type Numbers continuously tapered, polygonal cross section, 20 sided High mast (Grade BSEN 10025 - S355J0) of 20M normal mounting height with minimum diameters of 200mm at the top and 540 mm at the bottom, Minimum plate thickness 6mm,Base Flange diameter:740mm, Flange thickness:30 mm, PCD(Pitch Circle Diameter) :650mm, complete with 3 point suspension system, head frame canopy, 6mm stainless steel wire ropes to carry up to 12.Nos luminaries complete mounting bracket & accessories, one length 2.5 sqmm 8 core flat electrical trail copper cable 1100V grade, foundation bolt, nut, washer and Top & Bottom templates, lightning arrestors, lantern carraige, double drum winch, 3-phase 1.5HP Motor, earthing arrangement etc suitable for withstanding basic wind speed of 180KMPH including suitable 3PH power tools, twin aviation obstruction neon light as well as manual arrangement for raising lowering of lantern carriage with all necessary accessories, including suitable size Outdoor stand mounted duly painted Feeder Pillar box made by1.6mm thick CRCA steel sheets Enclosure with locking arragment comprising 63A Four Pole MCB as incomer, timer, Triple Pole contactor for the Automatic switching of luminaries and power tool control with 9A contactors and raise lower push button,Incoming 25 sqmm & outgoing 16&25 sqmm terminals including erection,testing & commissioning.
Supply of wall mounted 63A 4 WAY ETP Grade Numbers cupper busbar chamber with all accessories.
Supply of out door type S&T Type apparatus Numbers case with front & back door ,Lock & key arrangement with all accessories.
Suply of 3''/4'' GI Pipe.
Supply of 2'' Dia (50mm dia ) HDPE Pipe or Metre asper Site requirement with all accessories. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of 22W,48VLED Luminaries for under Numbers pit lighting.
Supply of Pit light Cover with Wire Mesg Guard Numbers & Locking arrangement.
Supply of 2KVAstep down transformer of Numbers capacity 2KVA,230/48V,50Hz MCB (DPI of 52A2304 on incoming side with TPN (1,4-way cable con 57 of suitable size & 6X10A HRC fuse for 6 No outgoing circuit all complete assemble in thick CRCA steel sheets Enclosure with internally embedded gasket Transformer for light Illumination.
Supply of 3phase 32A 5 pin+SC (scraping Numbers earth),4 module plastic plug &socket outlets with 32A 4Pole C series MCB in a suitable enclosure in CRCA sheet steel and installation charges.
Supply of 380/250 mm metal body Exhaust Numbers Fan wit all accessories & Wiring.
Supply of BLDC Ceiling Fan with remote control Numbers with 5 Star 1200 mm size, down rod etc., suitable for 230V, 50Hz,AC supply as per site requirement with step type electronicregulator.
Supply recess mounted Square Panel 2'' x 2'' Numbers Luminarie with all accessories.
Supply of LED 1x20W T-8 indoor typeTube Numbers Light fitting with Aluminum housing having Luminous flux efficacy 120 Lm/Watt,CRI75 for each tube light, with Constant current driver complete with lamp and all accessories.
Supply of Multi plug Board for computer power Numbers points in suitable size PVC Boxconsisting of (a) Plug Socket 5 Pin /6 A - 3 Nos, (b) Piano Switch - 6Amps -3 Nos, ( c ) Plug SOCKET -6 Pin/16 Amps- 1Nos ,( d) Piano Switch 16A -1 Nos (e ) MCB SP 16A ,10KA - 1Nos , ( f ) LED Indication Lamp - 1 Nos including internal wiring with 2.5 Sqmm single multi strended copper wire ( ISI Marked.).
Supply of IP65(dust proof & jet water tight) JB Numbers having size (LXBXH) of:300mmX450mmX170mm fitted with 2 No.TPN-100A cable connector terminal minimum 4,Nos cable entry arrangement.
Supply of 80 ltr capacity water cooler with 7 Numbers stage RO+UV filter cum purifier,RO membrance rating (4No X 75GPD or equivalent with auto flush) 50LPH purified water production capacity with freon 22 Refrigerant and puf insulation for storage tank.
Supply &laying of 8 SWG G I Wire.
Supply of wall -Supported 6 mtr long Set Waterproof,Rustproof Nos.Shockproof,Light weight,Strong Safe & Durable FRP Ladder.
Supply & testing of Digital Lux Meter.
Supply & testing of Portable Manual Insulation Set Resistance Tester Megger.
Supply of Hand Gloves suitable for 11KV Set system ISI Approved.
Supply of safety Belt.
Suppy & Erection of Fire fighting extinguisher Numbers 6Kg.Capacity (Dry Chemical Powder Class:ABE Type) as per IS 4308:2019.
LED Street light luminair in Die Cast Aluminium Numbers Body with heat sink in aluminium extursion,IP65,Tempered Glass,LED light 45 Watt,3500Lumens,240V,CRI70 with constant current driver. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of Distribution Board IP 43 Wall Numbers mounting type with provision of 1X32A TPN MCB as incoming and 6X16A-32A SP MCB as outgoing as per IS/IEC 60898-1,all assembled in a TP&N Prewired 4-Way CRCA steel sheets enclosure similar to Havells Cat.No.DHDMTHKDRA04.
Supply of Industrial power socket Distribution Numbers Board (DB) rated at 125A,415V,3P+N+E,comprising the following:100A,4-Pole MCCB for circuit protection 125A,5-Pin Round Top & 5-Pin Round Industrial Socket & Plug(01 each)Fully assembled in a sheet steel enclosure,ensuring durability and compliance with industrial standards.All necessary accessories,wiring,termination,and mounting arrangement are included for a complete and operational system.
Supply of DB 3 PH.and Neutral,415V of Numbers suitable size hinged door,wall mounted type of sheet steel,powder coated,foamed in P.U gasket consisting of 100A copper bus bar 4 Nos,1X63A MCCB 4P as incoming and 2X32A MCB DP & 4X16-20A MCB DP as outgoing with Neutral links,Earth bar,locking arrangement & LED indication lamp.
Supply of Digital Earth resistance tester with Numbers suitable kit of range 0-10-1000(Ohms).
Supply of LED 2X18/20W T-8 indoor type tube Numbers light fitting with Aluminium houshing having Luminous flux efficiency 120Lm/watt,CRI75 for each tube light,with constant current driver complete with lamp and all accessories. Total 5711866.00
Item Breakup - O-Execution of all work as per schedule
Concrete for foundation and plinth in all type cum of soil including hard/rocky soil (including excavation and supply of all materials viz., sand, cement, and ballast etc.).
Preparation equipment and OHE layout plan.
Preparation of as erected Drawings, SED etc.
Reinforced concrete for foundation, trench.
Reinforced concrete for trench cover.
B r i c k work,Brick masonry work in concrete cum mixture 1:4 to 1:6 or any other approved proportion with contractor's best kiln burnt second class bricks and sand of approved quality in walls of any thickness of all building,parapets,darins,platform etc. including watering and curing complete as required.Contractor to arrange water to any lead at his own cost.
Supply, spreading and levelling of 20 mm cum down graded blast, padding150mm in the switch yard.
Erection of rolled or fabricated and galvanized Tonne traction mast and auxiliary transformer masts, Bridge mast TTC Uprifgt and portal upright including DA, Dwarf mast etc.
Erection of steel gantries/portals/Mast and MT supporting structures and small parts steel work for switching post.
Erection of boom of fabricated and galvanised Tonne TTC and portal. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Erection of fabricated and galvanized steel Tonne works other than traction mast, DA, Dwarf mast etc.
Erection of single complete with insulator for conventional OHE and inside the tunnel.
Erection of guy rod assembly.
Erection of regulating equipment 3 pulley type Each complete with all accessories and adjustment of the same.
Erection of materials for termination of single Each conductor (including supply of cut-in insulator) of overhead equipment or a terminating wire.
Erection of materials for termination of double Each conductor (including supply of cut-in insulator) of overhead equipment.
Erection of overhead equipment, including Kilometre catenary, contact, jumper and dropper wires.
Erection of section insulator including core and cut-in insulator.
Erection of insulator.
Erection of 25KV post insulator.
Erection with/without earth contact assembly.
Erection of Structure bond on PF, Galvanised Each Steel Flexible wire Structure Bonds, structure bond ( other than PF), longitudinal bond.
Erection of Earth electrode.
Erection of MS flat for earth (50mmx6mm).
Erection of 18 mm solid copper busbar.
Erection of Copper Bus-bar terminal & Each connectors for 18mm bus-bar and multiple hole ( 19 mm ) bolted type terminal connector.
Erection of Bus splice for 18 mm Copper bus- Each bar.
Erection of Double pole Isolator with inter Each locking mechanism (1600 A).
Modification/Correction drawing/sectioning diagram at TPC, Control, Foot Station, Cabin etc.
Transportation of materials from Railways Tonne depots at CKP/TATA /KGP/SRC to site of work and any other site to work site.
Transfer of OHE from one support to another Each and adjustment of droppers.
Slewing/Re-slewing of each span.
Dismantling & removal of Dismantling of OHE. Kilometre
Dismantling & removal of Cantilever assembly. Each
Dismantling & removal of OHE termination Each assembly.
Dismantling & removal of Anchor assembly Each including regulating equipment.
Dismantling & removal of Isolator complete.
Dismantling & removal of Section insulator Each assembly.
Dismantling & removal of Small parts steel Tonne other than DA, Dwarf mast, TTC, Portal, Bridge mast etc.
Dismantling & removal of Guy rod assembly.
Dismantling in/suspension/post insulator.
Cutting/dismantling/removal of DA, Dwarf Tonne mast, Traction mast,ttc, Portal, Bridge mast etc. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Charges for Road crane working for Erection, Day dismantling and removing of Portals under power block.
Erection of 25 KV single pole Vaccum circuit Each breaker 2000A conforming to RDSO specification.
Erection of 25 KV single pole Vaccum Each interrupter conforming to RDSO specification.
Erection of Fencing upright as per RDSO Each approved drg.
Erection of Fencing pannel as per RDSO Each approved drg.
Erection of materials for termination of single Each conductor / cross feeder (FTA) with complete set.
Erection of ligntning Arrestor 42 KV rating for Each 25 KV side.
Erection of terminal board in control cubical.
Erection of 110V DC distribution board.
Erection of 230 V AC distribution board.
Erection of 25 KV PT type-I.
Erection of 25 KV PT type-II.
Erection of 25 kV Current transformer (3000- Each 1500/5A).
Erection of Al. Bus bar.
Erection of aluminium bus bar terminal Each assembly and different connectors for 50/39 mm bus bar.
Erection of 75mmx 8 mm mild steel flat.
Erection equipment earthing.
Erection of 8 SWG G.I. wire for earthing.
Running Erection of Anticlimbing device. Metre
Erection of 110 V, 200AH Lead Acid battery.
Erection of 110 V Lead Acid battery Charger Each (200AH).
Erection of 150 Sq. mm hard drawn copper MT conductor for feeder/return conductor.
Erection of control & relay panel board for the Each Protection of 01 CB & 2 Interruptors as per to RDSO's specification No.TI/SPC/PSI/Protect/6071.
Constructuon/modification of SSP Control room Each building.
Erection of aluminium and copper jumper.
Preparation of design and drawing of switching Each station.
Laying of different control cable.
Erection of burried rail (Excavation of earrth to Metre the depth of one meter below ground level for burying 13m long rail and connection as per RDSO drawing) Rail will be supplied by Railway.
Work under power block: Any erection work as Lumpsum per schedule if done under power and/or traffic block is subject to have extra rate. Note: Here unit numbers means lumpsum. Total 8103748.50
Item Breakup - P-Execution of all work as per schedule
Erection of LED 1x20W /2X20WT-8 indoor Numbers typeTube Light fitting including supply& erection of necessary clamps & masonry work.
Erection of Brusless DC (BLDC) Motor Ceiling Numbers Fan of1200mm with electronic regulator including suspension arrangement.
Exhaust fan with masonry work.
Erection of Wall mounted Air circulator fan Numbers 750mm sweep.
Erection,testing & commissioning of 5/6 Numbers mtr.long GI octagonal pole including transport as specified in Explanatory Note.
Erection of Feeder pillar box IP-56,plinty Numbers mounted type,3 phase and neutral,416V consisting of 4 Nos copper bus bar each 300A 1X250A MCCB 4-Pole (Adjustable Thermal & Adjustable Magnetic setting) as incoming and 3X100A MCCB 4-P250A,4Pole and 3X63A MCCB 4-P as per IS/IEC:60947-2,as outgoing &LED indication lamp in suitable size duly painted 2mm CRCA Steel sheets Enclosure with locking arrangement.
Fixing and commissioning of surface/recessed Numbers mounted 12 Way/8 Way Distribution boards with internal wiring.
Erection of outdoor type LED light fitting(IP-66) Numbers for front lighting 70-80 watt suitable for voltage 230V AC complete with driver and all other accessories.
Erection.testing & commissioning of High mast Numbers tower hot dip galvanized flange of 20M complete with all necessary accessories including foundation of high mast & Feeder piller as per approved drawing & also erection of dismantaled high mast tower.
Erection of LED Highbay fitting inside the cover Numbers shed complete with supply & fixing of suitable GI clamps etc.
Erection,fixing of MCB 25A 10KA with 3/5 pin Numbers 15A modular type socket with starter in a enclosure for A.C. point similar to DHDUCDPO2530156-25 with complete wiring.
Erection of Industrial type power plug and Numbers socket,63A With complete unit;63A,416V,3P+N+E with provision for protection IP-67 with 63A, 4P MCB and one 20A (1PH+N+E) plug & socket with 16A DP MCB and 100A TPN connector with Enclosure.
Erection of TP enclosure with3P+N+E Metal Numbers plug & Socket and 32A TPN MCB.
Erection,testing & commissioning of three Numbers phase astronomical timer based street light panel with all accessories.
Erection/Laying of GI pipe 3''/4'' dia with Numbers socket/clamp as per site requirement for laying of cable/vertical lifting of cable.
Erection of Earthing system with making of Numbers bore 3mtr long/depth & making of earth pit,fixing of earth pit chamber with fixing & termination of 40mmX3mm GI Strip of suitable length.
Erection of GI Flate of size 40mm x 3mm for Metre Earthing of all structure and vital equipment including required nut, bolts & sockets etc.
Fabrication fixing/erection of GI Cable tray with Metre GI fixing brackets,coupler plate with suitable GI nut,bolt & washer etc.
Erection of 100A,16kA MCCB weather proof enclosure box. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Erection of 200A 50kA 4P MCCB with Sheet Numbers Steel Enclosure.
Erection of MS sheet cable Busbar Chamber of Numbers Sizes 9''X10''X3'' (approx) with 4 Nos Copper bus bar of 63A capacity (as JB for crane) including fabrication work,necessary cable termination & masonary work.
Supply & Erection of RCC make cable route Numbers marker size L-12'',B-6''& H-30''.
Excavation of cable trench in all type of soil & Metre laying of HT/LT cable (Rly supplied) along the road and refilling of excavated earth as per CEE/GRC's Drg No. CEE/G/PA3/134 including supply & erection of cable gland, pyramid/Flat sockets, requisite nuts & bolts & all allied works.
Excavation of cable trench in all type of soil & Metre laying of HT/LT cable (Rly supplied) Across the road through GI/RCC/CI pipe and refilling of excavated earth as per CEE/GRC's Drg No.CEE/G/PA3/134 including supply & erection of cable gland, pyramid/Flat sockets, requisite nuts & bolts & all allied works.
Erection of cable In the air, fixing on Metre wall,through pipe/drain rail, structure with MS clamp with nut & bolt.
Laying of extra cable in same trench/HDPEE Metre pipe.
Excavation of trench in all kinds of soils Metre including soft rocky area and clearing of roots of trees, bushes, rocks,blast etc.,to a depth of 1m & width 0.3m including supply and laying of Double wall Corrugated Pipe with collars of 103mm inner dia and 120mm outer dia with coupler sand sockets as per RDSOspecf. No- RDSO/SPN/204/2011/Ver.1.1 Supply of one coupler for 6m of DWC Pipe and two couplers for 30m of length free of cost.
Transportation of Railway materials PVC cable Metre etc. from Railway depots in CKP/ADA/KGP/RNC division to site of work including loading and unloading at site.
Supply & fixing,wiring & commissioning of PVC Metre concealed conduit/PVC conduit surface /casing capping wiring by 2 Nos 4 sqmm PVC FRLS insulated copper cable 1100V grade through PVC conduit with running earth by 4 sqmm copper wire through out the wiring for drawing/extension of supply from Main DB/Busbar chamber to service main board/Circuit DB/Air conditioner point by 4 sq.mm cable.Note-(Quantity per meter means: one meter conduit with two meter 4sqmm PVCFRLS insulated copper cable & one meter 2.5/ 4 sqmm copper wire for running earth).
Supply & fixing,wiring & commissioning of PVC Metre concealed conduit/PVC conduit surface /casing capping wiring by 2 Nos 6 sqmm PVC FRLS insulated copper cable 1100V grade through PVC conduit with running earth by 4 sqmm copper wire through out the wiring for drawing/extension of supply from Main DB/Busbar chamber to service main board/Circuit DB/Air conditioner point by 6 sq.mm cable.Note-(Quantity per meter means: one meter conduit with two meter 6sqmm PVCFRLS insulated copper cable & one meter 4Sqmm copper wire for running earth). SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply & fixing,wiring & commissioning of PVC Metre concealed conduit/PVC conduit surface /casing capping wiring by 2 Nos 10 sqmm PVC FRLS insulated copper cable 1100V grade through PVC conduit with running earth by 6 sqmm copper wire through out the wiring for drawing/extension of supply from Main DB/Busbar chamber to service main board/Circuit DB/Air conditioner point by 10 sq.mm cable.Note-(Quantity per meter means: one meter conduit with two meter 10 sqmm PVCFRLS insulated copper cable & one meter 6 Sqmm copper wire for running earth).
Concrete for foundation in 1:3:6 ratio in any cum kind of soil including excavation and supply of all materials viz. sand, cement and ballast for TR plinth/SST pole/Rail Pole//Pillar Box/fencing panel/structure etc.
Boring/punching of underground crossing of Metre Railway track/road with pipe pushing by HDD technology & crossing HT/LT power cable below railway track/road through pipe.
Light, Bell & Fan point PVCconcealed Point conduit/PVCconduit surface/casingcapping wring by Supply &fixing of PVC conduit/casingcapping/PVC conduit ofminimum thickness 1.9mm& outer dia 16mm & above ,PVC FRLS insulated copper cable 1100V grade 2.5Sqmm conforming to IS694,with running earth by 14SWG tinned copperwire/1.5sqmm copper wire through out the wiring including Modular type hotdeep GI sheet concealed switch board,6A,Modular type switch with Metal back plate,electronic fan regulators,ceiling rose,holder etc & all wiring materials.
5/6 Amp. 5 pin plug socket point PVC Point concealed conduit/PVC conduit surface/casing capping wring by Supply & fixing of PVC conduit/casing capping/PVC conduit of minimum thickness 1.9mm & outer dia 16mm & above , PVC FRLS insulated copper cable 1100 V grade 2.5 Sq.mm conforming to IS 694, with running earth by 14SWG tinned copper wire/1.5 sqmm copper wire through out the wiring including Modular type hot deep GI sheet concealed switch board, 6 Amp, Modular type switch & Metal back Plate socket.
15 Amp plug socket point PVC concealed Point conduit/PVC conduit surface/casing capping wring by Supply & fixing of PVC conduit/casing capping/PVC conduit of minimum thickness 1.9mm & outer dia 16mm & above , PVC FRLS insulated copper cable 1100 V grade 4 Sq.mm conforming to IS 694, with running earth by 14SWG tinned copper wire/2.5 sqmm copper wire through out the wiring including Modular type hot deep GI sheet concealed switch board, 16 Amp, Modular type switch & Metal back Plate socket & all wiring materials.
Erection, testing & commissioning of 80 ltr Set capacity water cooler with 7 stage RO+UV filter cum purifier as per supply.
Erection of Recess mounted 2'' x 2'' Square Numbers Panel.
Dismantling of concrete kerb stones /rail level cum platform Stones/concrete beams//Slabs/ or similar light structural parts/stone without appreciable damage including stacking of serviceable materials & disposal of unserviceable materials within 50 M Lead. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Erection of IP -65 ( Dust proof Jet water tight Numbers )JB having Size L X B X H) of 300 x450 x 170 mm Fitted with 2 no TPN100 A Cable connector terminal minimum 4 no cable entry arrangement.
Erection,testing & commissioning of outdoor Numbers S&T type apparatus case with all accessories including foundation work.
Erection and commissioning of step down Numbers transformer of capacity 2KVA,230/48V,50Hz MCB (DPI of 52A2304 on incoming side with TPN (1,4-way cable con 57 of suitable size & 6X10A HRC fuse for 6 No outgoing circuit all complete assemble in thick CRCA steel sheets Enclosure with internally embedded gasket.
Erection ,testing & commissioning of 63A DP Numbers RCBO/63A/RCCB/63A/RCCB40A with 30A Sensitivity.
Erection ,testing & commissioning of 32A Numbers /20A/6A Capacity DP 'C' series MCB.
Preparation of All drawing for HT 11KV/33KV , Set LT Power line crossing /Detail wiring diagram /Power Supply Diagram /Sub station/ Schematic diagram & any other Service building /goomty and provide 6 copies of original.
Dismantalling/Shifting of Rail pole/SST pole Numbers /GI/MS Structure/Pumops/Control pannel etc with gas cutting or any other means without apprecible damage.
Handling cutting (to required size) and Numbers transportation of Rail pole (U/S) to work site including painting of pole (Released rail will be provided by Railway and to be collected and transported by the Contractor from different location of ADA/CKP/RNC Division to work site.
Erection of Distribution Board IP 43 Wall Numbers mounting type with provision of 1X32A TPN MCB as incoming and 6X16A-32A SP MCB as outgoing as per IS/IEC 60898-1,all assembled in a TP&N Prewired 4-Way CRCA steel sheets enclosure similar to Havells Cat.No.DHDMTHKDRA04.
Erection,testing and commissioning of Pre- Numbers cooling plug Socket,MCBs with combined unit/Box and bus bar chamber as per specification.
Erection of DB 3 PH.and Neutral,415V of Numbers suitable size hinged door,wall mounted type of sheet steel,powder coated,foamed in P.U gasket consisting of 100A copper bus bar 4 Nos,1X63A MCCB 4P as incoming and 2X32A MCB DP & 4X16-20A MCB DP as outgoing with Neutral links,Earth bar,locking arrangement & LED indication lamp. Total 1565817.00
Item Breakup - Q-Execution of all work as per schedule
Supply of LT Indoor (IP 53 OR higher) 3-phase Set & Neutral 415V floor mounted type comprising of 800A TPN Copper Bus bar Panel Configuration:Incoming:1 No.800A ACB,4P,415V,Breaking capacity 50kA Operational voltage 690V,Outgoing:(i) 2 Nos 400A,4-POLE,50kA,415V MCCBs (ii)2 Nos 250A,4-POLE,50kA,415V MCCBs(iii)2 Nos 160A,4-Pole,50kA,415V MCCBs(iv) 2 Nos 100A,4-Pole,50kA,415V MCCBs with necessary accessories.Digital metering system:Includes Smart Energy Meter,Digital Voltmeter,Ammeter,Energy Meter,CTs,etc.In addition Ammeter with each outgoing MCCB.All MCCBs will have Adjustable Thermal & Fixed Magnetic Settings with required protection arrangement.The above LT Indoor Panel will be as per the Description No.SER/ELEC/GS/DESCRIPTION/LTPANEL/1/REV- 1/JAN 2025.
Supply of Wall mounted air circulator fan Numbers 750mm/600mm sweep,230V AC,complete with frame and all necessary assories.
Supply of 5 mtr long GI octagonal pole with all Numbers accessories as specified in Explanatory Note.
Supply of outdoor type LT Panel board/Feeder Numbers Piller box IP-56,plinth mounted type, 3 phase and neutral,416V consisting of 4 Nos copper bus bar each 400A,1X400A MCCB 4- Pole(Adjustable Thermal & Adjustable Magnetic Setting) as incoming and 3X250A MCCB 4-Pole and 1X100A MCCB 4-Pole as per IS/IEC:60947- 2,as outgoing & LED indication lamp in suitable size duly painted 2mm CRCA steelsheets Enclosure with locking arrangement.
Supply of APFC panel 415V (+10% to -15%) 3 Numbers Phase, 3 wire/4wire system, frequency 50 Hz (± 6%), fault current 50 KA, congtrol voltage VAC, Enclosure should be fabricated in 2mm VRCA sheet afor Mian Frame and door , 1.6mm CRCA sgheet for partition sheets and covers with IP 42 protection, powded coated paint as per RAL 7032, IS:5 internal wiring should be 1 sq.mm copper stranded and for control and CT wiring/power wiring by 2.5 sq.mm of 650/1100V grade. LED indication lamp for R Y G in incomer side, multifuction meter, 3 CTs 800A/5A for metering and 1 for PF measurement. Control Transformer 415V/240V, Auto manual selevtor switch and control MCB. The capacitor and other accessories as follows: i) 255KVAr capacity APFC panel in 7 stage i.e. 50 KVAr (4 Nos.) HD G a s filled capacitor 440V, 50 Hz, 25KVr (2 N o s . ) , 5 KVAr (1 No.) suitable capacity contactor in every stage , 630A 3P MCCB with extended rotary handle as main incomer and Aux. contact 2C/O, suitable capacity HRC cylinderical fuses in every stage.
Supply of surface/flush mounted 12 Way Numbers vertical TP &N Distribution boards (MCCB I/C & 12+12+12 O/G module) with IP43 & IK 09 protection, single metal door with locking arrangements, with busbar, neutral link, Earth bar and DIN rail for provision of changeover switch, MCCBs , MCBs for incoming and distribution of power supply.
Supply of outdoor type LED light fitting(IP-66) Numbers for front lighting 70-80/90 watt suitable for voltage 230V AC complete with driver and all other accessories. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of LED flood light luminaire 200W,240V Numbers for high mast application with LED light as light source with reflector of reputed mark & necessary accessories.
Supply of LED Highbay fitting 150W along with Numbers excellent thermal management along with IP66 protection complete with electronics driver (SMPS based constant current supply) with Short Circuit,Over Voltage & Surge Protection and all other accessories.
Supply,testing of Occupancy Sensor working Numbers on PIR technology covering Micro motion & heavy motion Rated voltage 230V ± 10% ambient light 3 to 2000 Lux.Rated load - 2000watt (minimum) power consumption 0.5w (approx) detection range 360 degree with all necessary assories to complete the work in all respect including installation and commissioning.
Supply,testing of Occupancy Sensor working Numbers on PIR technology ABS cabinet of sensor,CRCA sheet Box 10'' X 12'' control panel with contactor 25A, metallic plug top and by pass MCB,rated voltage 220V-240V AC capacity- 3KW,recommended installation height 2-3 meters,maximum 6 meters,IP 20 protection,detection range 360degreewith all necessary assories to complete the work in all respect including installation and commissioning.
Supply of MCB 25A 10KA with 3/5 pin 15A Numbers modular type socket with starter in a enclosure for A.C. point similar to DHDUCDPO2530156- 25 with complete wiring.
Supply of Industrial type IP-67/66 power plug Numbers and socket,63A With complete unit;63A,416V,3P+N+E with provision for protection IP-67 with 63A, 4P MCB and one 20A (1PH+N+E) plug & socket with 16A DP MCB and 100A TPN connector with Enclosure.Power socket should be assembled in a Rain proof,high quality Thermoplastic Polycarbonate IP-66/67 dust & jet water proof,corroson,weather safe,acid and chemical resistant,fire retardant with internally embedded gasket box.
Supply of industrial type power socket 32A, Numbers 416V, 3P+N+E with 32A TPN MCB with Enclosure (similar ti Havells model No.DHDPBEN032 of Feb-2023).
Supply of three phase Astronomical timer Numbers based street light panel suitable for 12 KW Max. load including 65A TP Contactor 63A TPN MCB (similar to Havells IHXTSO306A).
Supply Erection, fabrication & painting of MT Miscellaneous iron work MS angle, flats,channel required nut, bolts etc. for Iron fencing 2.5 m height with gate, Small steel parts except rail pole for Fabrication of cable tray/Cross arms channel/4pole/2 pole structures etc.
Supply of Earth electrode of 2.8 M long, 54.4 Numbers mm inside dia and 60.2 mm out side dia, thickness 2.9mm GI pipe.The pipe having conically tapered at one end and having sufficient no. of holes of 12mm dia.including connection by 2.8.No SWG GI wire and making of earth cone sump box. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply,installation,testing and commisioning Numbers of Maintenance free Earthing system comprising of 48.3mm dia.3 mtr long earthing electrode with 250 microns copper coating + carbon based conductive back fill compound & copper Clamp including suitable length earthing GI strip of 40x3mm with termination works.
Supply of GI Flate of size 40mm x 3mm for Metre Earthing of all structure and vital equipment including required nut, bolts & sockets etc.
Supply of 1.1KV 3.5 CORE 70-120 sq.mm LT Numbers straight through heat shrinkable kit.
Supply of Heat shrinkable type indoor/outdoor Numbers end termination/straight through Cable jointing kit as per IS 13573 : Part 3, suitable for 11kV, 3 Core 70/95/120/185-300 Sq.mm XLPE Cable.
Supply of wire mesh type/Galvanised iron Metre cable tray of Stainless Steel, 2.5 mm thick 300mm width with SS fixing bracket,coupler & bend plat with suitable SS nut & washer etc.
Supply of 200A 50kA 4P MCCB with Sheet Numbers Steel Enclosure.
Supply of 40A 2P Adi type RCCB for AC + Numbers Pulsating DC (Type A) + Harmonics with 30mA Sensitivity with enclosure.
Supply of 63A 4P Adi type RCCB for AC + Numbers Pulsating DC (Type A) + Harmonics with 100/300mA Sensitivity with enclosure.
Supply of MS sheet cable Busbar Chamber of Numbers Sizes 9''X10''X3'' (approx) with 4 Nos Copper bus bar of 63A capacity each,all assembled in CRCA sheet, Enclosure (similar to Havells Cat.No.IHBC006304).
Supply & laying of Insulated rubber mat 1m x Numbers 1m x 2cm as per IS 15652;2006.
Supply of Feeder pillar box IP-56,plinty Set mounted type,3 phase and neutral,416V consisting of 4 Nos copper bus bar each 300A 1X250A MCCB 4-Pole (Adjustable Thermal & Adjustable Magnetic setting) as incoming and 3X100A MCCB 4-P250A,4Pole and 3X63A MCCB 4-Pole as per IS/IEC:60947-2,as outgoing & LED indication lamp in suitable size duly painted 2mm CRCA steel sheets Enclosure with locking arranement.
Supply of 200A 50kA 4P MCCB with Sheet Numbers Steel Enclosure.
Supply 63A Capacity RCBO.
Supply of 100A 4 Pole 'C' Series MCCB.
Supply of 32A Capacity DP 'C' Series MCB.
Supply of 20A Capacity DP 'C' Series MCB.
Supply of 6A Capacity DP 'C' Series MCB.
Supply of water tight Weatherproof Enclosure Numbers of 4 Module. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Hot dip galvanized flange mounted type Numbers continuously tapered, polygonal cross section, 20 sided High mast (Grade BSEN 10025 - S355J0) of 20M normal mounting height with minimum diameters of 200mm at the top and 540 mm at the bottom, Minimum plate thickness 6mm,Base Flange diameter:740mm, Flange thickness:30 mm, PCD(Pitch Circle Diameter) :650mm, complete with 3 point suspension system, head frame canopy, 6mm stainless steel wire ropes to carry up to 12.Nos luminaries complete mounting bracket & accessories, one length 2.5 sqmm 8 core flat electrical trail copper cable 1100V grade, foundation bolt, nut, washer and Top & Bottom templates, lightning arrestors, lantern carraige, double drum winch, 3-phase 1.5HP Motor, earthing arrangement etc suitable for withstanding basic wind speed of 180KMPH including suitable 3PH power tools, twin aviation obstruction neon light as well as manual arrangement for raising lowering of lantern carriage with all necessary accessories, including suitable size Outdoor stand mounted duly painted Feeder Pillar box made by1.6mm thick CRCA steel sheets Enclosure with locking arragment comprising 63A Four Pole MCB as incomer, timer, Triple Pole contactor for the Automatic switching of luminaries and power tool control with 9A contactors and raise lower push button,Incoming 25 sqmm & outgoing 16&25 sqmm terminals including erection,testing & commissioning.
Supply of wall mounted 63A 4 WAY ETP Grade Numbers cupper busbar chamber with all accessories.
Supply of out door type S&T Type apparatus Numbers case with front & back door ,Lock & key arrangement with all accessories.
Suply of 3''/4'' GI Pipe.
Supply of 2'' Dia (50mm dia ) HDPE Pipe or Metre asper Site requirement with all accessories.
Supply of 22/48Watt LED Luminaries for under Numbers pit lighting.
Supply of Pit light Cover with Wire Mesg Guard Numbers & Locking arrangement.
Supply of 2KVA Illumination.
Supply of 3phase 32A 5 pin+SC (scraping Numbers earth),4 module plastic plug &socket outlets with 32A 4Pole C series MCB in a suitable enclosure in CRCA sheet steel and installation charges.
Supply of 380 mm metal body Exhaust Fan wit Numbers all accessories & Wiring.
Supply of BLDC Ceiling Fan with remote control Numbers with 5 Star 1200 mm size, down rod etc., suitable for 230V, 50Hz,AC supply as per site requirement with step type electronicregulator.
Supply recess mounted Square Panel 2'' x 2'' Numbers Luminarie with all accessories.
Supply of LED 1x20W T-8 indoor typeTube Numbers Light fitting with Aluminum housing having Luminous flux efficacy 120 Lm/Watt,CRI75 for each tube light, with Constant current driver complete with lamp and all accessories. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of Multi plug Board for computer power Numbers points in suitable size PVC Boxconsisting of (a) Plug Socket 5 Pin /6 A - 3 Nos, (b) Piano Switch - 6Amps -3 Nos, ( c ) Plug SOCKET -6 Pin/16 Amps- 1Nos ,( d) Piano Switch 16A -1 Nos (e ) MCB SP 16A ,10KA - 1Nos , ( f ) LED Indication Lamp - 1 Nos including internal wiring with 2.5 Sqmm single multi strended copper wire ( ISI Marked.).
Supply of IP65(dust proof & jet water tight) JB Numbers having size (LXBXH) of:300mmX450mmX170mm fitted with 2 No.TPN-100A cable connector terminal minimum 4,Nos cable entry arrangement.
Supply of 80 ltr capacity water cooler with 7 Numbers stage RO+UV filter cum purifier,RO membrance rating (4No X 75GPD or equivalent with auto flush) 50LPH purified water production capacity with freon 22 Refrigerant and puf insulation for storage tank.
Supply &laying of 8 SWG G I Wire.
Supply of wall -Supported 6 mtr long Set Waterproof,Rustproof Nos.Shockproof,Light weight,Strong Safe & Durable FRP Ladder.
Supply & testing of Digital Lux Meter.
Supply & testing of Portable Manual Insulation Set Resistance Tester Megger.
Supply of Hand Gloves suitable for 11kv Set system ISI Approved.
Supply of safety Belt.
Supply & Erection of 11KV Panel with 01 No Set VCB of capacity 3 phase 11KV,800A,26.3KA,3 pole 6 panel indoor floor mounted vaccum circuit breaker (2 incoming,one bus coupler and 3 outgoing) complete with bus bar,motor and manually controlled spring charged mechanism,complete with 3 nos C.T,3 nos P.T,4 nos of protective Relays(3-O.C & 1-,E/F) TRI-vector meter,P.F meter heater circuit,status indicator,hooter/alarm,including all other associated accessories with PVC insulated copper busbar of 1200A capacity with battery and battery charger.
Suppy & Erection of Fire fighting extinguisher Numbers 6Kg.Capacity (Dry Chemical Powder Class:ABE Type) as per IS 4308:2019. Total 11150099.00
Item Breakup - R-Execution of all work as per schedule
Erection of LED 1x20W T-8 indoor typeTube Numbers Light fitting including supply& erection of necessary clamps & masonry work.
Erection of Brusless DC (BLDC) Motor Ceiling Numbers Fan of1200mm with electronic regulator including suspension arrangement.
Exhaust fan with masonry work.
Erection of Wall mounted Air circulator fan Numbers 750mm sweep.
Erection,testing & commissioning of 5 mtr.long Numbers GI octagonal pole including transport as specified in Explanatory Note. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Erection of LT Indoor (IP 53 OR higher) 3-phase Numbers & Neutral 415V floor mounted type comprising of 800A TPN Copper Bus bar Panel Configuration:Incoming:1 No.800A ACB,4P,415V,Breaking capacity 50kA Operational voltage 690V,Outgoing:(i) 2 Nos 400A,4-POLE,50kA,415V MCCBs (ii)2 Nos 250A,4-POLE,50kA,415V MCCBs(iii)2 Nos 160A,4-Pole,50kA,415V MCCBs(iv) 2 Nos 100A,4-Pole,50kA,415V MCCBs with necessary accessories.
Erection of Feeder pillar box IP-56,plinty Numbers mounted type,3 phase and neutral,416V consisting of 4 Nos copper bus bar each 300A 1X250A MCCB 4-Pole (Adjustable Thermal & Adjustable Magnetic setting) as incoming and 3X100A MCCB 4-P and 3X63A MCCB 4-Pole as per IS/IEC:60947-2,as outgoing & LED indication lamp in suitable size duly painted 2mm CRCA steel sheets Enclosure with locking arrangement.250A,4Pole and 3X63A MCCB 4- Pole as per IS/IEC:60947-2,as outgoing & LED indication lamp in suitable size duly painted 2mm CRCA steel sheets Enclosure with locking arranement.
Erection of Feeder Pillar box IP-56,plinth Numbers mounted type,3 phase and neutral,416V consisting of 4 Nos copper bus bar each 400A,1X400A MCCB 4-Pole(Adjustable Thermal & Adjustable Magnetic Setting) as incoming and 3X250A MCCB 4-Pole and 1X100A MCCB 4- Pole as per IS/IEC:60947-2,as outgoing & LED indication lamp in suitable size duly painted 2mm CRCA steelsheets Enclosure with locking arrangement.
Fixing, testing and commissioning of APFC Numbers panel as specified in supply schedule.
Fixing and commissioning of surface/recessed Numbers mounted 12 Way/8 Way Distribution boards with internal wiring.
Erection of outdoor type LED light fitting(IP-66) Numbers for front lighting 70-80 watt suitable for voltage 230V AC complete with driver and all other accessories.
Erection.testing & commissioning of High mast Numbers tower hot dip galvanized flange of 20M complete with all necessary accessories including foundation of high mast & Feeder piller as per approved drawing & also erection of dismantaled high mast tower.
Erection of LED Highbay fitting inside the cover Numbers shed complete with supply & fixing of suitable GI clamps etc.
Erection,fixing of MCB 25A 10KA with 3/5 pin Numbers 15A modular type socket with starter in a enclosure for A.C. point similar to DHDUCDPO2530156-25 with complete wiring.
Erection of Industrial type power plug and Numbers socket,63A With complete unit;63A,416V,3P+N+E with provision for protection IP-67 with 63A, 4P MCB and one 20A (1PH+N+E) plug & socket with 16A DP MCB and 100A TPN connector with Enclosure.
Erection of TP enclosure with3P+N+E Metal Numbers plug & Socket and 32A TPN MCB.
Erection,testing & commissioning of three Numbers phase astronomical timer based street light panel with all accessories.
Erection/Laying of GI pipe 3''/4'' dia with Numbers socket/clamp as per site requirement for laying of cable/vertical lifting of cable. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Erection of Earthing system with making of Numbers bore 3mtr long/depth & making of earth pit,fixing of earth pit chamber with fixing & termination of 40mmX3mm GI Strip of suitable length.
Erection of GI Flate of size 40mm x 3mm for Metre Earthing of all structure and vital equipment including required nut, bolts & sockets etc.
Erection of 1.1KV 3.5 CORE 70-120 sq.mm LT Numbers straight through heat shrinkable kit.
Erection & termination of Heat shrinkable type Numbers indoor/outdoor end termination/Straight through cable jointing kit.
Fabrication fixing/erection of GI Cable tray with Metre GI fixing brackets,coupler plate with suitable GI nut,bolt & washer etc.
Erection of 100A,16kA MCB weather proof enclosure box.
Erection of 200A 50kA 4P MCCB with Sheet Numbers Steel Enclosure.
Erection of MS sheet cable Busbar Chamber of Numbers Sizes 9''X10''X3'' (approx) with 4 Nos Copper bus bar of 63A capacity (as JB for crane) including fabrication work,necessary cable termination & masonary work.
Supply & Erection of RCC make cable route Numbers marker size L-12'',B-6''& H-30''.
Excavation of cable trench in all type of soil & Metre laying of HT/LT cable (Rly supplied) along the road and refilling of excavated earth as per CEE/GRC's Drg No. CEE/G/PA3/134 including supply & erection of cable gland, pyramid/Flat sockets, requisite nuts & bolts & all allied works.
Excavation of cable trench in all type of soil & Metre laying of HT/LT cable (Rly supplied) Across the road through GI/RCC/CI pipe and refilling of excavated earth as per CEE/GRC's Drg No.CEE/G/PA3/134 including supply & erection of cable gland, pyramid/Flat sockets, requisite nuts & bolts & all allied works.
Erection of cable In the air, fixing on Metre wall,through pipe/drain rail, structure with MS clamp with nut & bolt.
Laying of extra cable in same trench/HDPEE Metre pipe.
Excavation of trench in all kinds of soils Metre including soft rocky area and clearing of roots of trees, bushes, rocks,blast etc.,to a depth of 1m & width 0.3m including supply and laying of Double wall Corrugated Pipe with collars of 103mm inner dia and 120mm outer dia with coupler sand sockets as per RDSOspecf. No- RDSO/SPN/204/2011/Ver.1.1 Supply of one coupler for 6m of DWC Pipe and two couplers for 30m of length free of cost.
Transportation of Railway materials PVC cable MT etc. from Railway depots in CKP/ADA/KGP/RNC division to site of work including loading and unloading at site. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply & fixing,wiring & commissioning of PVC Metre concealed conduit/PVC conduit surface /casing capping wiring by 2 Nos 4 sqmm PVC FRLS insulated copper cable 1100V grade through PVC conduit with running earth by 4 sqmm copper wire through out the wiring for drawing/extension of supply from Main DB/Busbar chamber to service main board/Circuit DB/Air conditioner point by 4 sq.mm cable.Note-(Quantity per meter means: one meter conduit with two meter 4sqmm PVCFRLS insulated copper cable & one meter 2.5/ 4 sqmm copper wire for running earth).
Supply & fixing,wiring & commissioning of PVC Metre concealed conduit/PVC conduit surface /casing capping wiring by 2 Nos 6 sqmm PVC FRLS insulated copper cable 1100V grade through PVC conduit with running earth by 4 sqmm copper wire through out the wiring for drawing/extension of supply from Main DB/Busbar chamber to service main board/Circuit DB/Air conditioner point by 6 sq.mm cable.Note-(Quantity per meter means: one meter conduit with two meter 6sqmm PVCFRLS insulated copper cable & one meter 4Sqmm copper wire for running earth).
Supply & fixing,wiring & commissioning of PVC Metre concealed conduit/PVC conduit surface /casing capping wiring by 2 Nos 10 sqmm PVC FRLS insulated copper cable 1100V grade through PVC conduit with running earth by 6 sqmm copper wire through out the wiring for drawing/extension of supply from Main DB/Busbar chamber to service main board/Circuit DB/Air conditioner point by 10 sq.mm cable.Note-(Quantity per meter means: one meter conduit with two meter 10 sqmm PVCFRLS insulated copper cable & one meter 6 Sqmm copper wire for running earth).
Concrete for foundation in 1:3:6 ratio in any cum kind of soil including excavation and supply of all materials viz. sand, cement and ballast for TR plinth/SST pole/Rail Pole//Pillar Box/fencing panel/structure etc.
Boring/punching of underground crossing of Metre Railway track/road with pipe pushing by HDD technology & crossing HT/LT power cable below railway track/road through pipe.
Light, Bell & Fan point PVCconcealed Point conduit/PVCconduit surface/casingcapping wring by Supply &fixing of PVC conduit/casingcapping/PVC conduit ofminimum thickness 1.9mm& outer dia 16mm & above ,PVC FRLS insulated copper cable 1100V grade 2.5Sqmm conforming to IS694,with running earth by 14SWG tinned copperwire/1.5sqmm copper wire through out the wiring including Modular type hotdeep GI sheet concealed switch board,6A,Modular type switch with Metal back plate,electronic fan regulators,ceiling rose,holder etc & all wiring materials.
5/6 Amp. 5 pin plug socket point PVC Point concealed conduit/PVC conduit surface/casing capping wring by Supply & fixing of PVC conduit/casing capping/PVC conduit of minimum thickness 1.9mm & outer dia 16mm & above , PVC FRLS insulated copper cable 1100 V grade 2.5 Sq.mm conforming to IS 694, with running earth by 14SWG tinned copper wire/1.5 sqmm copper wire through out the wiring including Modular type hot deep GI sheet concealed switch board, 6 Amp, Modular type switch & Metal back Plate socket. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
15 Amp plug socket point PVC concealed Point conduit/PVC conduit surface/casing capping wring by Supply & fixing of PVC conduit/casing capping/PVC conduit of minimum thickness 1.9mm & outer dia 16mm & above , PVC FRLS insulated copper cable 1100 V grade 4 Sq.mm conforming to IS 694, with running earth by 14SWG tinned copper wire/2.5 sqmm copper wire through out the wiring including Modular type hot deep GI sheet concealed switch board, 16 Amp, Modular type switch & Metal back Plate socket & all wiring materials.
Erection,testing and commissioning of 11KV Set Panel capacity 3 phase 11KV,800A,26.3KA,3 POLE 6 panel indoor floor mounted vacuum circuit breaker (2 incoming,one bus coupler and 3 outgoing) complete with bus bar,motor and manually controlled spring charged mechanism,complete with 3nos C.T,3 NOS P.T,4 nos of protective Relays(3-O.C & 1- E/F),tri-vector meter,PF meter,heater circuit,status indicator,hooter/alarm,including all other associated accessories with PVC insulated copper busbar of 1200A capacity with battery and battery charger.
Erection, testing & commissioning of 80 ltr Set capacity water cooler with 7 stage RO+UV filter cum purifier as per supply.
Erection of Recess mounted 2'' x 2'' Square Numbers Panel.
Dismantling of concrete kerb stones /rail level cum platform Stones/concrete beams//Slabs/ or similar light structural parts/stone without appreciable damage including stacking of serviceable materials & disposal of unserviceable materials within 50 M Lead.
Erection of IP -65 ( Dust proof Jet water tight Numbers )JB having Size L X B X H) of 300 x450 x 170 mm Fitted with 2 no TPN100 A Cable connector terminal minimum 4 no cable entry arrangement.
Erection,testing & commissioning of outdoor Numbers S&T type apparatus case with all accessories including foundation work.
Erection and commissioning of step down Numbers transformer of capacity 2KVA,230/48V,50Hz MCB (DPI of 52A2304 on incoming side with TPN (1,4-way cable con 57 of suitable size & 6X10A HRC fuse for 6 No outgoing circuit all complete assemble in thick CRCA steel sheets Enclosure with internally embedded gasket.
Erection ,testing & commissioning of 63A DP Numbers RCBO/63A RCCB/40A RCCB with 30A Sensitivity.
Erection ,testing & commissioning of 32A Numbers /20A/6A Capacity DP 'C' series MCB.
Preparation of All drawing for HT 11KV/33KV , Set LT Power line crossing /Detail wiring diagram /Power Supply Diagram /Sub station/ Schematic diagram & any other Service building /goomty and provide 6 copies of original. Total 2147089.00
Item Breakup - S-Execution of all work as per schedule
Supply of rolled or fabricated and galvanized Tonne traction mast/gantry mast and auxiliary transformer masts, Feeder mast. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of TTC structures with boom.
Supply of fabricated and galvanized portals Tonne with boom.
Supply of fabricated and galvanized steel Tonne works other than traction mast, DA, Dwarf mast etc.
Supply of single cantilever assembly complete Each with insulator for conventional OHE and inside the tunnel.
Supply of guy rod assembly.
Supply of regulating equipment 3 pulley type Each complete with all accessories including counter weight assembly and SS wire rope for convention at OHE.
Supply of materials for termination of single Each conductor (including supply of cut-in insulator) of overhead equipment or a terminating wire.
Supply of materials for termination of double Each conductor (including supply of cut-in insulator) of overhead equipment.
Supply of overhead equipment excluding Kilometre catenary, contact, jumper and dropper wires (which will be supplied by Railways).
Supply of section insulator assembly including Each core and cut-in insulator.
S u p p l y of 25kV single interlocking mechanism.
Supply of platform).
Supply of Longitudinal bond.
Supply of Earth electrode.
Supply of MS flat for earth (50mmx6mm).
Supply of transverse, Cross and special bond.
Supply and erection of Retro reflective Caution Each board for 25KV AC traction in 3 language Hindi, English & Oriya.
Supply and erection of retroreflective Danger Each board for 25KV.
Supply and erection of Retro reflective type Each Unwired turn-out board.
Supply and erection of Retro reflective Public Each caution board in three language English, Hindi & Oriya.
Supply and erection of Shock treatment chart Each in two language.
Supply and erection of Retro reflective Electric Each engine stop board.
Supply and erection of Retro reflective type Each Power block working limit board.
Supply and erection of Sectioning diagram.
Supply and erection of Additional Retro Each reflective location number plate conforming to RDSO Spec.
Supply of 25KV solid core suspension insulator Each including material for suspension arrangement.
Supply of 25KV post insulator.
Supply and erection of Catenary and contact Each splice.
Supply of 18 mm solid copper busbar.
Supply of Copper Bus-bar connectors for 18mm bus-bar.
Supply of Bus splice for 18 mm Copper bus- Each bar.
Supply of multiple hole ( 19 mm ) bolted type Each terminal connector(1009). SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of Double pole Isolator with inter Numbers locking mechanism (1600 A). Total 23420017.00
Item Breakup - T-Execution of all work as per schedule
Supply of LT panel board with copper busbar Set of 630A, 3-Phase & Neutral 416V floor mounted type comprising of 2X 630A 4-pole Microprocessed based trip unit ACB(manual draw out) with mechanical contact6 crosion indicator as Incoming & 1X 630A,55KA MCCB Bus Coupler(with interlocking system) and 4X 250A,36KA,4-pole MCCB( adjustable Thermal and adjustable magnetic setting type),3X100A 4P MCCB 25KA,3X63A 4P MCCB &2X16A DP MCB 10KA as outgoinh including HRC type back up fuses with each MCCBs as per theire rating,electronic Frequency meter,energy meter,EF & OC relay,Digital voltmeter & ammeter etc.with selector switch, LED indication lamp on each incoming & outgoing circuit.
Supply of LT Distribution board rated for 3- Set phase & Neutral 416V,constructed from 2mm CRCA steel sheets with a durable paint finish .The Distribution board shall include Copper Bus bar 4 Nos,each rated 300A Incoming MCCB:(i)1x250A,4-Pole MCCB (adjustable Thermal & Fixed Magnetic Setting ,55KA,Microprocessor Based) with digital voltmeter & Ammeter,CT,phase indication lamp & rotary handle,spreader terminal & phase barrier and all other necessary accessories outgiing MCCB:(I) 1x 200A 4-Pole MCCB,55KA (II)1X63A,4-Pole MCCB (iii) 2X 32A,4-pole MCCB including internal wiring & 1 set (3nos) LED based indication lamp.
Supply of LT Distribution board rated for 3- Set phase & Neutral 416V,constructed from 2mm CRCA steel sheets with a durable paint finish .The Distribution board shall include Copper Bus bar 4 Nos,each rated ar 300A Incoming MCCB:(i)1x250A,4-Pole MCCB (adjustable Thermal & Fixed Magnetic Setting ,55KA,Microprocessor Based) with digital voltmeter & Ammeter,CT,phase indication lamp & rotary handle,spreader terminal & phase barrier and all other necessary accessories outgiing MCCB:(I) 3x 100A 4-Pole MCCB,25KA (II)2X63A,4-Pole MCCB (iii) 4X16- 32A,4-pole DP MCB including internal wiring & 1 set (3nos) LED based indication lamp.
Supply of LT Panel(IP 53 or higher)3-phase & Set Neutral 416V,constructed from 2mm CRCA steel sheets with a durable paint finish .The LT Panelhall be Floor mounted type comprising of 500A TPN Copperf Bus bar Incoming MCCB: (i)1x400A,4-Pole MCCB (adjustable Thermal & Fixed Magnetic Setting ,65KA,Microprocessor Based) with digital voltmeter & Ammeter,CT,phase indication lamp & rotary handle,spreader terminal & phase barrier and all other necessary accessories outgoing MCCB:(I) 1x 300A 4-Pole MCCB,65KA (II)5X160A,4-Pole MCCB,55KA including internal wiring & 1 set (3nos) LED based indication lamp. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of LTPanel(IP 53 or higher)3-phase & Set Neutral 416V,constructed from 2mm CRCA steel sheets with a durable paint finish .The LT Panel shall be Floor mounted type comprising of 500A TPN Copperf Bus bar Incoming MCCB: (i)1x400A,4-Pole MCCB (adjustable Thermal & Fixed Magnetic Setting ,65KA,Microprocessor Based) with digital voltmeter & Ammeter,CT,phase indication lamp & rotary handle,spreader terminal & phase barrier and all other necessary accessories outgoing MCCB:(I) 8x 160A 4-Pole MCCB,50kA including internal wiring & 1 set (3nos) LED based indication lamp.
Supply of three phase Astronomical timer Numbers based street light panel suitable for 12 KW Max. load including 65A TP Contactor 63A TPN MCB,415V-1No,digital timer 24Hrs-1 No.
Supply adjuctable thermal & fixed magnetic in Sheet Steel Enclosure.
Supply adjuctable thermal & fixed magnetic in Sheet Steel Enclosure.
Surface/flush mounted 12 way vertical Set Distribution board (MCCB I/C & 12+12++12 O/G module) with IP-43 & IK 09 protection,single metal door with locking arrangements with busbar,neutral link,Earth bar and DIN rail with complete internal wiring for provision of changeover switch,MCCBs,MCBs for incoming and distribution of power supply.
Supply of 100A 4-Pole 36kA MCCB with a Numbers enclosure.
Supply of 32A (DP) C-Series MCB with a Numbers enclosure.
Supply Distribution board with IP-43 & IK 09 protection,metal door with locking arrangement,DIN Rail,earth bar & neutral with complete internal wiring.
Supply of Busbar Chamber 250A capacity Numbers consisting 3PH+N copper Busbar with provision of Ample Space for wiring,Step wise Busbar Mounting,High Insulated Materials Support for Busbar Assembly & Tin plated Copper Busbar.
Supply of Industrial type power plug and Numbers socket,63A With complete unit;63A,416V,3P+N+E with provision for protection IP-67 with 63A, 4P MCB and one 20A (1PH+N+E) plug & socket with 16A DP MCB and 100A TPN connector with Enclosure.
Supply of Industrial type power socket DB Numbers 32A,416V,3P+N+E with 32A TPN MCB with 32A 5-pin Round Top & 5-pin round industrial socket & Plug each-01 No.all assembled in sheet steel enclosure.
Supply of Industrial type power socket DB Numbers 20A,230V,2P+E with 32A SPN MCB with 32A 3- pin Round Top & 3-pin round industrial socket & Plug each-01 No.all assembled in sheet steel enclosure.
Supply of 32A MCB (DP) C-series.
Supply of 6A MCB (DP) C-series.
Supply of sheet steel MCB enclosure for DP Numbers MCB.
Supply of 63A RCBO DP A-type,100mA. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of IP65(dust proof & jet water tight) JB Set having size (LXBXH) of:300mmX450mmX170mm fitted with 2 No.TPN-100A cable connector terminal minimum 4,Nos cable entry arrangement.
Supply of New generation energy saving and Numbers enviroment friendly long life 90W LED Street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and Toughened glass having Bottom Opening separate driver compartment with IP66 protection and impact resistance of IK07.
Supply of Wall mounted Industrial air circulator Numbers fan 750mm/600mm sweep with all necessary accessories including wiring.
Supply of Hot dip galvanized flange mounted Numbers type continuously tapered, polygonal cross section, 20 sided High mast (Grade BSEN 10025 - S355J0) of 20M normal mounting height with minimum diameters of 200mm at the top and 540 mm at the bottom, Minimum plate thickness 6mm,Base Flange diameter:740mm, Supply of High mast tower hot dip galvanized flange of 20M Flange thickness:30 mm, PCD(Pitch Circle Diameter) :650mm, complete with 3 point suspension system, head frame canopy, 6mm stainless steel wire ropes to carry up to 12.Nos luminaries complete mounting bracket & accessories, one length 2.5 sqmm 8 core flat electrical trail copper cable 1100V grade, foundation bolt, nut, washer and Top & Bottom templates, lightning arrestors, lantern carraige, double drum winch, 3-phase 1.5HP Motor, earthing arrangement etc suitable for withstanding basic wind speed of 180KMPH including suitable 3PH power tools, twin aviation obstruction neon light as well as manual arrangement for raising lowering of lantern carriage with all necessary accessories, including suitable size Outdoor stand mounted duly painted Feeder Pillar box made by1.6mm thick CRCA steel sheets Enclosure with locking arragment comprising 63A Four Pole MCB as incomer, timer, Triple Pole contactor for the Automatic switching of luminaries and power tool control with 9A contactors and raise lower push button.
Supply of LED flood light luminaire 200W,240V Numbers Exclusive innovative die-cast aluminium non integral IP66 flood light,suitable for high mast application along with LED light & necessary accessories.
Supply of LED Highbay fitting 150W along with Numbers IP66 protection complete with LED lamp,driver and all other accessories.
Supply of LED Light fifting 22W, 48V of Set standard size along with LED light confirming with IP65/IP66 & IK 10 water & dust proof for pit light & Catwalk light including all acessories.
Supply & fixing of water proof MS box of size Set 400x325x150MM/as per dimension of light fixing on inside wall of pit for fIXing pit lights.
Supply of step down transformer of capacity Set 2KVA 230V/48V,50HEAL MCB (DPI of 52A2304 on incoming side wh TPN (1,4-way cable con 57 of sullable size & 6X 10A HRC fuse for 6 No outgoing circuit all compleme assemble in e imm thick CRCA steel sheets Enclosure with internally embedded gasket. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of exhaust fan 450mm/380mm sweep Numbers heavy duty copper wound with anticorrosive blade as per relevent IS along complete with all accessories.
Supply of Energy efficient(5star rating) Numbers Brushless DC (BLDC) Motor Ceiling Fan of 1200mm with electronic regulator including suspension arrangement.
Supply mounted LED light luminaries with BIS certified driver and luminare,operating voltage of 150- 270V having industrial grade constant current driver (36W each).
Supply of Energy efficient indoor type LED Set tube light fitting 1x18W /20W with Aluminium housing having Luminous flux efficacy 120 lm/watt,CRI75 with constant current driver complete with lamp and all accessories.
Supply of GI pipe 3"/4" dia with socket for Metre laying/verticle lifting of cable.
Supply of GI pipe 6'' dia with socket for Metre laying/verticle lifting of cable.
Supply of 2'' Dia (50mm) HDPE pipe.
Supply of GI perforated type cable tray made Metre out of 2.0mm thick sheet in standard length of 2.5mtr Duly hot dip galvanised including coupler plate with suitable GI Nut,bolts & washer of 250mm WX 75mm H.
MCB 25A 10KA with 3/5 pin 15A modular type Numbers socket with starter in a enclosure for A.C. point similar to DHDUCDPO2530156-25 with complete wiring.
Supply of 80 ltr capacity water cooler with 7 Numbers stage RO+UV filter cum purifier,RO membrance rating (4No X 75GPD or equivalent with auto flush) 50LPH purified water production capacity with freon 22 Refrigerant and puf insulation for storage tank.
Supply,installation,testing and commisioning Set of Maintenance free Earthing system comprising of 48.3mm dia.3 mtr long earthing electrode with 250 microns copper coating + carbon based conductive back fill compound & copper Clamp including suitable length earthing GI strip of 40x3mm with termination works.
Supply of Earth electrode of 2.8 M long, 50 Set mm Normal bore thickness 2.9mm GI hot dip pipe as per latest Drawing No.CEE/G/A3/P-150. with having 13nos hole of 12mm Dia and conically tapered at one end including connection by 2X8No.SWG GI wire and making of earth cone sump box.
Supply of GI Flate of size 40mm x 3mm for Metre Earthing of all structure and vital equipment including required nut, bolts & sockets etc.
Supply,testing of Occupancy Sensor working Numbers on PIR Technology covering Micro motion & heavy motion rated voltage 230V ± 10% ambient light 3 to 2000 Lux,Rated load - 2000watt(approx) detection range 360 degree and all other condition as mentioned in PCEE/SER/GRC office letter no.CEE/S/185/519/Gen./1 Date:13.04.2022 with all necessary assories to complete the work in all respect including installation and commissioning. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply,testing of Occupancy Sensor working Numbers on PIR Technology ABS cabinet of sensor,CRCA sheet Box 10''X12" control panel with contactor 25A,mettallic plug top and by pass MCB,rated voltage 220-240V AC capacity- 3KW,recommended installation height 2-3 meters,maximum 6 meters,IP 20 protection,detection range 360 degree and all other condition as mentioned in PCEE/SER/GRC o ffi c e letter no.CEE/S/185/519/Gen./1 Date:13.04.2022 with all necessary assories to complete the work in all respect including installation and commissioning.
Supply of Digital Earth clamp tester Motwane Set make (Model No.DECT-3) including all accessories.
Supply & erection of Insulated rubber mat 1m Numbers X1m.
Supply of crimping tool of capacity 25 sqmm to Set 400 sqmm having 11 set of hexagonal dies.
Supply of tiltable tower ladder,size19/33ft.
Supply of wall -Supported 6 mtr long Set Waterproof,Rustproof Nos.Shockproof,Light weight,Strong Safe & Durable FRP ladder.
Supply & testing of Digital Clamp meter.
Supply & testing of Digital Lux Meter.
Supply & testing of Portable Manual Insulation Set Resistance Tester Megger.
Supply of Hand Gloves suitable for 11kv Set system ISI Approved.
Supply of safety Belt.
Supply of IP65 pole mounted junction box Set 200X200X150mm,Polycarbonate Lockable door type pvc junction box having provision of 4-way terminal busbar with16A fuse unit with all accessories.
Supply of exhaust fan with BLDC motor Numbers 250/225,mm sweep heavy duty copper wound with anticorrosive blade as per relevent IS along complete with all accessories.
Supply of 100A,36kA MCCB weather proof enclosure box.
Supply of Feeder Pillar box IP-56,plinth Set mounted type,3 phase and neutral,416V consisting of 4 Nos copper bus bar each 300A 1X250A MCCB 4-Pole (Adjustable Thermal & Adjustable Magnetic setting) as incoming and 3x100A MCCB 4-Pole and 3x63A MCCB 4-Pole as per IS/IEC:60947-2,as outgoing & LED indication lamp in suitable size duly painted 2mm CRCA steel sheets Enclosure with locking arrangement.
Supply LED Street Light Luminair in Die Cast Numbers Aluminium Body with heat sink in aluminium extrusion, IP65, Tempered Glass, LED light 45 Watt, >3500 Lumens, 240V, CRI >70 with Constant Current driver.
Supply of Street light pole of 6/7 mtr length,hot Set dip Galvanised,Octagonal shape,fabricated from 3mm thick HT sheet (Grade BSEN 10025- S355J0) with top dia 70mm AF (Across Flats),bottom dia 130mm (Across Flat),with base plate of size 220X220X12 mm (IS:2062),earth lug,along with 1000mm long single/double arm bracket bent at an angle of 120degree,made of 48.3mm dia heavy duty G.I pipe,including TS-600 grade J-Type M20X600MM long foundation bolts along with required quantity of templates for the pole &. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of 2X18/20w LED type tube light fitting Set with Aluminium housing having Luminous flux efficacy 120 Lm/watt,CRI175 for each tube light with constant current driver complete with lamp and all accessories.
Supply of Distribution Board IP 43 wall Set mounting type with provision of 1x32A TPN MCB as incoming and 6x16A-32A SP MCB asoutgoing as per IS/IEC 60898-1,all assembled in a TP&N Prewired 4-way CRCA steel sheets enclosure similar to Havells Cat.No.DHDMTHKDRA04.
Supply of Industrial Socket Distribution Board Numbers (DB) rated at 125A,416V,3P+N+E comprising the following 100A,4P MCCB for circuit protection 125A,5-pin Round Top & 5-pin Round Industrial Socket & Plug (01 each) Fully assembled in a sheet steel enclosure,ensuring durability and compliance with industrial standared.All necessary accessories,wiring,termination and mounting arrangement are included for a complete and operation system.
Supply and Erection of LED lamp 10watt,230V. Numbers
Supply of Bus bar Chamber 63A capacity Numbers consisting 3PH+ N copper Busbar (strip) with provision of Ample Spsce for Wiring,step wise Busbar Mounting,High insulated Materials Support for Bus bar Assemblyh & Tin Plated Copper Bus Bar.
Supply of Distribution Board IP 43 wall Set mounting type with provision of 1x63A,10kA DP MCB as incoming & 10 Nos X6A SP MCB and 4 Nos X10A SP MCB 10kA as outgoing as per IS/IEC 60898-1,housing in a SP&N Prewired 6-way CRCA steel sheets enclosure with Neutral Link,Eatrh bar & Din Rail.
Multi plug Board for computer power points in Set suitable size PVC Boxconsisting of (a) Plug Socket 5 Pin /6 A - 3 Nos, (b) Piano Switch - 6Amps -3 Nos, ( c ) Plug SOCKET -6 Pin/16 Amps- 1Nos ,( d) Piano Switch 16A -1 Nos (e ) MCB SP 16A ,10KA - 1Nos , ( f ) LED Indication Lamp - 1 Nos including internal wiring with 2.5 Sqmm single multi strended copper wire ( ISI Marked.).
Supply &laying of 8 SWG G I Wire.
Supply & Testing of BDV Testing Kit with all Set accessories.
Supply & Testing of Industrial Vaccum Cleaner Set ,Wet & Dry Type Cleaning. Total 11647626.20
Item Breakup - U-Execution of all work as per schedule
Concrete for foundation and plinth in all type cum of soil including hard/rocky soil (including excavation and supply of all materials viz., sand, cement, and ballast etc.).
Preparation equipment and OHE layout plan.
Preparation of as erected Drawings, SED etc.
Erection of rolled or fabricated and galvanized Tonne traction mast and auxiliary transformer masts, Bridge mast TTC Uprifgt and portal upright including DA, Dwarf mast etc.
Erection of boom of fabricated and galvanised Tonne TTC and portal. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Erection of fabricated and galvanized steel Tonne works other than traction mast, DA, Dwarf mast etc.
Erection of single complete with insulator for conventional OHE and inside the tunnel.
Erection of guy rod assembly.
Erection of regulating equipment 3 pulley type Each complete with all accessories and adjustment of the same.
Erection of materials for termination of single Each conductor (including supply of cut-in insulator) of overhead equipment or a terminating wire.
Erection of materials for termination of double Each conductor (including supply of cut-in insulator) of overhead equipment.
Erection of overhead equipment, including Kilometre catenary, contact, jumper and dropper wires.
Erection of section insulator including core and cut-in insulator.
Erection of insulator.
Erection of 25KV post insulator.
Erection with/without earth contact assembly.
Erection of Structure bond on PF, Galvanised Each Steel Flexible wire Structure Bonds, structure bond ( other than PF), longitudinal bond.
Erection of Earth electrode.
Erection of MS flat for earth (50mmx6mm).
Erection of 18 mm solid copper busbar.
Erection of Copper Bus-bar terminal & Each connectors for 18mm bus-bar and multiple hole ( 19 mm ) bolted type terminal connector.
Erection of Bus splice for 18 mm Copper bus- Each bar.
Erection of Double pole Isolator with inter Each locking mechanism (1600 A).
Modification/Correction drawing/sectioning diagram at TPC, Control, Foot Station, Cabin etc.
Transportation of materials from Railways Tonne depots at CKP/TATA /KGP/SRC to site of work and any other site to work site.
Transfer of OHE from one support to another Each and adjustment of droppers.
Slewing/Re-slewing of each span.
Dismantling & removal of Dismantling of OHE. Kilometre
Dismantling & removal of Cantilever assembly. Each
Dismantling & removal of OHE termination Each assembly.
Dismantling & removal of Anchor assembly Each including regulating equipment.
Dismantling & removal of Isolator complete.
Dismantling & removal of Section insulator Each assembly.
Dismantling & removal of Small parts steel Tonne other than DA, Dwarf mast, TTC, Portal, Bridge mast etc.
Dismantling & removal of Guy rod assembly.
Dismantling in/suspension/post insulator.
Cutting/dismantling/removal of DA, Dwarf Tonne mast, Traction mast,ttc, Portal, Bridge mast etc. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Charges for Road crane working for Erection, Day dismantling and removing of Portals under power block.
Work under power block: Any erection work as Lumpsum per schedule if done under power and/or traffic block is subject to have extra rate. Note: Here unit numbers means lumpsum. Total 4548199.00
Item Breakup - V-Execution of all work as per schedule
LED 2x 20W and 1x20W T-8 indoor typeTube Numbers Light fitting of Schedule-F, including supply& erection of necessary clamps & masonry work.
Energy efficient (5-star rating) AC ceiling fan Numbers with BLDC Motor including electronic regulator and all accessories.
Exhaust fan with masonry work.
Erection testing &commissioning of 6/7 Mtr G I Numbers Octagonal pole with all accessories Including earth connection & LED Street light fitting & wiring from MCB To light fitting.
Erection,testing and commissioning of Out Numbers door type LT control panel for distribution board consisting of 1X 630A,55KA MCCB Bus Coupler(with interlocking system) and 4X 250A,36KA,4-pole MCCB( adjustable Thermal and adjustable magnetic setting type),3X100A 4P MCCB 25KA,3X63A 4P MCCB &2X16A DP MCB 10KA as outgoinh including HRC type back up fuses with each MCCBs as per theire rating,electronic Frequency meter,energy meter,EF & OC relay,Digital voltmeter & ammeter etc.with selector switch, LED indication lamp on each incoming & outgoing circuit.
Erection ,Testing and commissioning of LT Numbers control Panel for distribution board consisting of copper busbar with (I) 1 x 250/300 A MCCB TP ,36KA as Incoming and outgiing MCCB:(I) 1x 200A 4-Pole MCCB,55KA (II)1X63A,4-Pole MCCB (iii) 2X 32A,4-pole MCCB including internal wiring & 1 set (3nos) LED based indication lamp. O R LT Panel shall be Floor mounted type comprising of 500A TPN Copperf Bus bar Incoming MCCB:(i)1x400A,4-Pole MCCB (adjustable Thermal & Fixed Magnetic Setting ,65KA,Microprocessor Based) with digital voltmeter & Ammeter,CT,phase indication lamp & rotary handle,spreader terminal & phase barrier and all other necessary accessories outgoing MCCB:(I) 8x 160A 4-Pole MCCB,50kA including internal wiring & 1 set (3nos) LED based indication lamp.
Erection of CLS Panel/ LT DB Comprising of Numbers 63A TPN MCB with busbar as incoming & 4 x32 A ,4 X16 A DP MCB as Out going.
Erection, testing and commissioning of IP-43 Numbers Wall mountiong typeDB w i t h provision of 1x32A, TPN MCCB as incoming and 4x16A, 4x32A DP MCB as outgoing.
Fxing & commissioning of surface /recess Numbers mounted 12-way /16 way distibution board with internal wiring.
Erection of LED High Bay fitting inside the Numbers cover Shed complete with supply & Fixing of suitable GI Clamps. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Erection ,Fixing of MCB Of 25A ,10KA with 3/5 Numbers Pin 15 A modular type Socket with Starter in a enclosure for A.C POINT Similar to DHDUCDPO 2530156-25 with complete wiring.
Erection of industrial type piower Plug & Numbers Socket ,63A/32A/20A with complete unit ;63A ,416V ,3P+N+E with provision for protection IP-67WITH 63A MCB & One 20A Plug & socket with 16A DP MCB & 100 A TP&N Connector with Enclosure.
Erection ,testing & commissioning of three Numbers phase astronomical timer based street light panel with all accessories.
Erection of Busbar Chamber IP-43 & IP 65 wall Numbers mounting type as per supply including fabrication work,necessary cable termination & masonry work.
Excavation of earth in any kind of soil as Numbers available at site and erection of earth cone as per Railway's Drg.No.CEE/G/A3/P-134 including measurements and writing of earth resistance value with date.
Erection of GI Flate of size 40mm x 3mm of Metre required nut, bolts & sockets etc.
LED wall/structure/shed (except Octagonal/SST Pole) with all accessories including necessary masonry work.
Erection/Laying of GI pipe 3"/4"/6'' dia with Numbers socket/clamp as per site requirement, for laying /vertical lifting of cable.
Erection,testing & commissioning of (a) Hot dip Numbers galvanised flange mounted type polygonal tapered type High mast of 20M long nominal mounting height complete with all necessary accessories including LED Flood Light Luminair ,and (b) Outdoor stand mounted Feeder Piller complete with all necessary accessories including foundation of high mast & Feeder piller as per approved drawing.
Erection of 50 mm / 75mm Dia HDPE.
Fabrication ,Fixing /erection of GI Cable tray Metre with GI fixing bracket ,coupler plate with suitable GI Nut,bolts & Washer Etc.
Erection of 100A/160A ,36KAKA MCCB 4 POLE Numbers With weather proof Enclosure.
Erection ,testing & commissioning of 63 A Numbers Capacity of double pole RCBO With 30mA Sensitivity.
Erection of 32A ,10KA MCB 4 POLE With Numbers weather proof Enclosure.
Erection ,testing &commiissing of 32A & 6A Numbers Capacitry DP ' C ' Series MCB.
Erection& /400A,36KA/50KA 4P MCCB with Steel enclosure.
Erection of IP -65 ( Dust proof Jet water tight Numbers )JB having Size L X B X H) of 300 x450 x 170 mm Fitted with 2 no TPN100 A Cable connector terminal minimum 4 no cable entry arrangement.
Supply &erection of RCC Make cable route Numbers marker of Size L-12'', B-6''& H-30''. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Light, Bell & Fan point PVC concealed Point conduit/PVC conduit surface/casing capping wring by Supply & fixing of PVC conduit/casing capping/PVC conduit of minimum thickness 1.9mm & outer dia 16mm & above , PVC FRLS insulated copper cable 1100 V grade 2.5 Sq.mm conforming to IS 694, with running earth by 14SWG tinned copper wire/1.5 sqmm copper wire through out the wiring including Modular type hot deep GI sheet concealed switch board, 6 Amp, Modular type switch with Metal back Plate, electronic fan regulators,ceiling rose,holder etc & all wiring materials.
5/6 Amp. 5 pin plug socket point PVC Point concealed conduit/PVC conduit surface/casing capping wring by Supply & fixing of PVC conduit/casing capping/PVC conduit of minimum thickness 1.9mm & outer dia 16mm & above , PVC FRLS insulated copper cable 1100 V grade 2.5 Sq.mm conforming to IS 694, with running earth by 14SWG tinned copper wire/1.5 sqmm copper wire through out the wiring including Modular type hot deep GI sheet concealed switch board, 6 Amp, Modular type switch & Metal back Plate socket.
15/16 Amp plug socket point PVC concealed Point conduit/PVC conduit surface/casing capping wring by Supply & fixing of PVC conduit/casing capping/PVC conduit of minimum thickness 1.9mm & outer dia 16mm & above , PVC FRLS insulated copper cable 1100 V grade 4 Sq.mm conforming to IS 694, with running earth by 14SWG tinned copper wire/2.5 sqmm copper wire through out the wiring including Modular type hot deep GI sheet concealed switch board, 16 Amp, Modular type switch & Metal back Plate socket & all wiring materials.
Supply & fixing,wiring & commissioning of PVC Metre concealed conduit/PVC conduit surface /casing capping wiring by 2 Nos 4 sqmm PVC FRLS insulated copper cable 1100V grade through PVC conduit with running earth by 4 sqmm copper wire through out the wiring for drawing/extension of supply from Main DB/Busbar chamber to service main board/Circuit DB/Air conditioner point by 4 sq.mm cable.Note-(Quantity per meter means: one meter conduit with two meter 4sqmm PVCFRLS insulated copper cable & one meter 2.5/ 4 sqmm copper wire for running earth).
Supply & fixing,wiring & commissioning of PVC Metre concealed conduit/PVC conduit surface /casing capping wiring by 2 Nos 6 sqmm PVC FRLS insulated copper cable 1100V grade through PVC conduit with running earth by 4 sqmm copper wire through out the wiring for drawing/extension of supply from Main DB/Busbar chamber to service main board/Circuit DB/Air conditioner point by 6 sq.mm cable.Note-(Quantity per meter means: one meter conduit with two meter 6sqmm PVCFRLS insulated copper cable & one meter 4Sqmm copper wire for running earth). SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply & fixing,wiring & commissioning of PVC Metre concealed conduit/PVC conduit surface /casing capping wiring by 2 Nos 10 sqmm PVC FRLS insulated copper cable 1100V grade through PVC conduit with running earth by 6 sqmm copper wire through out the wiring for drawing/extension of supply from Main DB/Busbar chamber to service main board/Circuit DB/Air conditioner point by 10 sq.mm cable.Note-(Quantity per meter means: one meter conduit with two meter 10 sqmm PVCFRLS insulated copper cable & one meter 6 Sqmm copper wire for running earth).
Excavation of cable trench in all type of soil & Metre laying of HT/LT cable (Rly supplied) along the road and refilling of excavated earth as per CEE/GRC's Drg No. CEE/G/PA3/134 including supply & erection of cable gland, pyramid/Flat sockets, requisite nuts & bolts & all allied works.
Excavation of cable trench in all type of soil & Metre laying of HT/LT cable (Rly supplied) Across the road through GI/RCC/CI pipe and refilling of excavated earth as per CEE/GRC's Drg No. CEE/G/PA3/134 including supply & erection of cable gland, pyramid/Flat sockets, requisite nuts & bolts & all allied works.
E r e c t i o n of cable In the air, fixing on Metre wall,through pipe/drain rail, structure with MS clamp with nut & bolt.& also laying in the same trench.
Laying of Extra cable in the same trench /HDPE Metre Pipe.
Boring/punching of underground crossing of Metre Railway track/road with pipe pushing by HDD technology & crossing HT/LT power cable below railway track/road through pipe.
Concrete for foundation in 1:3:6 ratio in any cum kind of soil including excavation and supply of all materials viz. sand, cement and ballast for TR plinth/SST pole/Rail Pole//Pillar Box/fencing panel/structure etc.
Transportation of Railway supply materials Tonne from Railways depots in CKP/ADA/KGP/RNC division to site of work with lead.
Handling cutting( to required size) and Tonne transportation of Rail pole(U/S) to work site including painting of pole and erection of rail pole(Released rail will be provided by Railway and to be collected and transported by the Contractor from different location of ADA/CKP/RNC. Division to work site.
Supply & Erection of Galvanized stay set for Numbers over head line complete with 19/20mm dia x 1.9M long stay road anchor plate of 45cmx45cmx7.5cm including turn buckle clamp and 7/5mm dia GI stay wire with Guy insulator & all accessories.
Erection ,Testing &commissioning of IP- 55 Numbers Step down Transformer of capacity 2 KVA ,230V /48V 50Hz ,ac.
Dismantling and removal of existing overhead Each LT/HT line with accessories. Span
Dismantlling/Shifting pole/GI/MS Structure/Pumps/control pannel etc.with gas cutting or any other means without appreciable damage.
Erection ,testing & commissioning of out door Numbers type (Rainwater tight) Feeder Pillar Box / Location Box Floor /Plint Mounted Type. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Dismantling of concrete kerb stones /rail level cum platform Stones/concrete beams//Slabs/ or similsr light structural parts/stone without appreciable damage including stacking of serviceable materials & disposal of unserviceable materials within 50 M Lead.
Erection of LED Pit light fitting 20w/22W 48 V Set LED Light with MS Cover/ cage along with cutting grooves &masonory works.
Erectiopn of 90W LED Street light Fitting fitted Numbers in pressure diecast aluminium alloy Housing with IP-66 Protection,complete with electronic Driver and all other assessories.
Erection of Indoor type TFL Fitting recess Numbers mounted Low glare White LED 2' x 2' luminare 36W each.
Erection of Wall mounted Industrial air Numbers circulator fan 750mm/600mm sweep with all necessary accessories including wirings.
Preparation of All drawing for HT 11KV/33KV , Numbers LT Power line crossing /Detail wiring diagram /Power Supply Diagram /Sub station/ & any other Service building /goomty.
Supply,Erection,fabrication & painting of MT Miscellaneous iron work MS angle,flats,channel,base plate for ROB & V- bracket with required nut,bolts etc. & for Iron fenching 2.5 m height with gate,Small steel parts except rail pole for Fabrication of cable tray/Cross arms channel/cross bracing & knee bracing/4 pole/2 pole /single pole structure etc.
Erection of Self contained drinking water Numbers Cooler Storage type ,Cooling Capacity 150 ltr/Hrs. Total 2652486.00
A-Execution of all work as per schedule 29263468.32 Below/Pa
B-Execution of all work as per schedule 360247017.83 Below/Pa
C-Execution of all work as per schedule 20724324.12 Below/Pa
D-Execution of all work as per schedule 2574990.00 Below/Pa
E-Execution of all work as per schedule 15684562.60 Below/Pa
F-Execution of all work as per schedule 396480.00 Below/Pa
G-Execution of all work as per schedule 888374.28 Below/Pa
H-Execution of all work as per schedule 43467.68 Below/Pa
I-Execution of all work as per schedule 97985952.00 Below/Pa
J-Execution of all work as per schedule 13616284.00 Below/Pa
K-Execution of all work as per schedule 12545966.00 Below/Pa
L-Execution of all work as per schedule 26505361.50 Below/Pa
M-Execution of all work as per schedule 8907830.00 Below/Pa
N-Execution of all work as per schedule 5711866.00 Below/Pa
O-Execution of all work as per schedule 8103748.50 Below/Pa
P-Execution of all work as per schedule 1565817.00 Below/Pa
Q-Execution of all work as per schedule 11150099.00 Below/Pa
R-Execution of all work as per schedule 2147089.00 Below/Pa
S-Execution of all work as per schedule 23420017.00 Below/Pa
T-Execution of all work as per schedule 11647626.20 Below/Pa
U-Execution of all work as per schedule 4548199.00 Below/Pa
V-Execution of all work as per schedule 2652486.00 Below/Pa
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril-2022.pdf
ATTACHMENT
TD25-2026.pdf
ATTACHMENT
BarChart_1.pdf
ATTACHMENT
JharkhandGovtletter.pdf
ATTACHMENT
AdvanceCorrectionSlipNo1to11.pdf Advance Correction Slips
ATTACHMENT
MechanicalConditions.pdf
ATTACHMENT
AdvanceCorrectionSlipNo1to11.pdf
ATTACHMENT
Download all tender documents and submit your bid