| 1 | L1₹26.9 LAccepted-AOC SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹26.9 L Quoted ₹29.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹30.9 L+₹1.0 L (3.48%)Rejected-Finance 10 SUBASH COLONY DEF LAB ROAD RATANADA JODHPUR 342006 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342006 | ₹30.9 L+₹1.0 L (3.48%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹33.5 L+₹3.7 L (12.3%)Rejected-Finance | ₹33.5 L+₹3.7 L (12.3%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹34.8 L+₹4.9 L (16.5%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹34.8 L+₹4.9 L (16.5%) | L4 | Rejected-Finance Other than L1 |
Tender Value
₹34.1 L
EMD Value
₹68,200
Closing Date
21 Jan 2023, 6:00 pmClosed
CWE PATHANKOT
HQ CWE PATHANKOT PIN-145001
CWE/P-35/2022-23 SPECIAL REPAIR TO CENTRAL AC PLANT OF OPERATION THEATRE AT MH UNDER GE (SOUTH) PATHANKOT
2022_MES_565200_2
CWE/P-35/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE SOUTH PATHANKOT
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE SOUTH PATHANKOT
₹68,200
Yes
20 Feb 2023
29 Dec 2022
23 Jan 2023
29 Dec 2022
21 Jan 2023
9 Jan 2023
Amount
Supply installations,testing and commissioning in replacement of unsv double -skin type horizontal, floor-mounted,top/side discharge cabinet capable of delivering 12000 CFM air at 125 static prsessure and having thermal break profilecomplete with air ttight casing using gaskets and self adhesive tapes and 0.6mm thick pre-coated outer skin and 0.6 mm thick GI inner skin,25+/- 2 mm thick double skin panel with pressure injected CFC & HCFC gree PUF having 'k' value of 0.02 W/C/m & density 40kg/m, AMCA certified energy efficient plug fabs with backward curved impellers for high static pressure mounted on aluminium extruded siderail base frame with EU4 pre filter and EU7 fine filter(shall be mounted on a common frame )suitable high efficiency(IE3 ) TEFC squirrel cage induction motor, PVC/nylon hinges and handles,view port and marine lamp limit switch vibration isolators/rubber pads(minimum 1 " thick )inspection windows, Flexible connection made with airtight ASTM E84(Class I)polyester fire retardent cloth riveted on periphery of cloth with extruded aluminium 'L' angle flange as per fan size at discharge duct/pienum complete all as specified
Supply installations,testing and commissioning in replacement of unsv double -skin type horizontal, floor-mounted,top/side discharge cabinet capable of delivering 9000 CFM air at 125 static prsessure and having thermal break profile complete with air tight casing using gaskets and self adhesive tapes and 0.6mm thick pre-coated outer skin and 0.6 mm thick GI inner skin,25+/- 2 mm thick double skin panel with pressure injected CFC & HCFC gree PUF having 'k' value of 0.02 W/C/m & density 40kg/m, AMCA certified energy efficient plug fabs with backward curved impellers for high static pressure mounted on aluminium extruded siderail base frame with EU4 pre filter and EU7 fine filter(shall be mounted on a common frame )suitable high efficiency(IE3 ) TEFC squirrel cage induction motor, PVC/nylon hinges and handles,view port and marine lamp limit switch vibration isolators/rubber pads(minimum 1 " thick )inspection windows, Flexible connection made with airtight ASTM E84(Class I)polyester fire retardent cloth riveted on periphery of cloth with extruded aluminium 'L' angle flange as per fan size at discharge duct/pienum complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv 8 RD chiller water cooling coils & 2 RD Heating coil 12000 cfm section with 0.15 mm thick alfins and copper tubes tested on 21 kg /cm with SS sandwiched drain tray etc complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv 8 RD chiller water cooling coils & 2 RD Heating coil 9000 cfm section with 0.15 mm thick all fins and copper tubes tested on 21 kg /cm with SS sandwiched drain tray etc complete all as specified and directed.
Supply installation testing & commissioning in replacement of unsv 3 way mixing/diverting valves of size 65mm complete all as specified and directed.
Supply installation testing & commissioning in replacement of unsv 3 way mixing/diverting valves of size 32mm complete all as specified and directed.
Supply installation testing & commissioning in replacement of unsv Butterfly valve of PN 1.6 of size 80 mm complete all as specified and directed.
Supply installation testing & commissioning in replacement of unsv Butterfly valve of PN 1.6 of size 65 mm complete all as specified and directed.
Supply installation testing & commissioning in replacement of unsv Butterfly valve of PN 1.6 of size 32 mm complete all as specified and directed.
Supply installation testing & commissioning in replacement of unsv Balancing valve (to control flow of water) of PN 1.6 of size 80 mm complete all as specified and directed.
Supply installation testing & commissioning in replacement of unsv Balancing valve (to control flow of water) of PN 1.6 of size 65 mm complete all as specified and directed.
Supply installation testing & commissioning in replacement of unsv Balancing valve (to control flow of water) of PN 1.6 of size 32mm complete all as specified and directed.
Supply installation testing & commissioning in replacement of unsv HEPA filter having filteration level 99.9% down to 0.03 Microns complete all as specified and directed.
Supply & installations in replacement of unsv AL plenum made of 20 Gauge for HEPA filters as per existing size and shape complete all as directed and specifed.
Supply & installation in replacement of unsv Acountistic insulation with itrile Rubber open cell foam with density 140-180 kg/m3 and Class I Fire performance and with antimicrobial protection and should pass Fungi resistance as per ASTM G 21 and Bacterial Resistance as per ASTM E 21 using manufacturer's recommended rubber based adhesive in ablend of solvents Thickness of insulation 10mm complete all as specified and directed.
Supply and installation in replacement of unsv canvas connection for cabinet and ducting as per existing size and shape complete all as specified and directed.
Supply installation, testing and commissioning in replacement of unsv moitorized combination fire and smoke dampers (fusible link type) in supply air main duct. The fire damper shall be monitorzed so as to close the damper automatically in the event of power failure and open the damper when power is restored. The Fire and smoke damper shall be complete with electronic temperature sensor and electrically operated actautor and interconnecting wiring between AHU & dampers. The fire damper shall be located in the supply air ducts complete all as specified and directed.
Supply installation testing & commissioning in replacement of unsv scroll compressors of model No .XAC3VS-036MR3 of capacity 36 TR of make Blue star or equivalent to carrier, Voltas, Kirloskar complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv air cooled copper condenser for model No. .XAC3VS-036MR3 of capacity 36 TR of make Blue star or equivalent to carrier, Voltas, Kirloskar complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv condensor fan motors of size 7 HP, 415V, 3 Phase 2900 RPM suitable for model No.XAC3VS-036MR3 of capacity 36 TR of make Blue star or equivalent to carrier, Voltas, Kirloskar complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv evaporator duly insulation along with controls and expansion valves for model No.XAC3VS-036MR3 of capacity 36 TR of make Blue star or equivalent to carrier, Voltas, Kirloskar , Size as per existing at site complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv control panel along with PCB, Aux, multimeter, contractor, relay etc and display for model No.XAC3VS-036MR3 of capacity 36 TR of make Blue star or equivalent to carrier, Voltas, Kirloskar complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv control such as LP,HP and Anti-freezer for model No XAC3VS-036MR3 of capacity 36 TR of make Blue star or equivalent to carrier, Voltas, Kirloskar complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv pressure testing including vacuum & refrigerant charging R- 407 as required on the site for model No XAC3VS-036MR3 of capacity 36 TR of make Blue star or equivalent to carrier, Voltas, Kirloskar complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv Monoblock type chilled water pumps with bronze impeller mechanical seal with 7 LPS at 20 M head included with MS channel frame coupled with motor of 7.5 HP 3 Phase, 415 V, 1400 RPM complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv pressure gauge complete suitable for model No. .XAC3VS-036MR3 of capacity 36 TR of make Blue star or equivalent to carrier, Voltas, Kirloskar complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv water flow switch of type and size available at site complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv Motor actuator for fire damper as per exising size complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv control panel for fire damper along with wire and smoke sensor with pre fitted circuit etc. complete all as directed and specified
Supply installation testing and commissioning in replacement of unsv Humidistat & cooling & heating thermostat complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv MS heavy grade chilled water piping 80mm dia with insulation 50mm thick EPS pipe section final finished with AL sheet cladding and sand cement plaster complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv 65 MM MS piping class C heavy grade piping dully insulated with 50mm thick EPS pipe section final finished with 26 gauge AL sheet cladding and sand cement plaster complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv 32 MM MS piping class C heavy grade piping dully insulated with 50mm thick EPS pipe section final finished with 26 Gauge AL sheet cladding/sand cement plaster complete all as specified and directed.
Supply and fabrication in replacement of unsv AL ducting as per the SMACNA (Sheet metal and air conditioning contractors national association) standards fabrication at the site of suitable size complete all as specified and directed.
Supply & installation in replacement of unsv nitrile closed cell insulation of 9mm thick FR class 'O' complete all as specified and directed.
Supply installation testing and commissioning in replacement of unsv starter panel 7.5 HP With control wiring limit switch, volt meter, amp meter, indicators withi pre wired circuit complete all as specified and directed.
Supply, laying, jointing & testing 50 Sq mm 3.5 Core LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and directed.
Supply, laying, jointing & testing 6 Sq mm 3 Core LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and directed.
Material and labour earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion. NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Supply installation and commissioning of Electric Air vent as per the eixting size availabe at site complete all as specified and directed.
Supply, installation and commissioning of Water Electric heater of 22KW suitable for existing system complete all as directed and specified.
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule(BoQ) to arrive at Contract Sum.
Panwar Electricals
GOLDEN CONSTRUCTIONS
M/S SATPAL & BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .