Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC HOUSE NO 6 18 WARD NO 05 HOUSING BOARD COLONY HANUMANGARH JN 335512 RAJ | HANUMANGARH | RAJASTHAN | 335512 | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.0 L+₹1.8 L (9.36%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Highest bid quoted other then L1 | |
| 3 | L3₹21.8 L+₹2.6 L (13.5%)Rejected-Finance 79 B BLOCK SRI GANGANAGAR 335001 RAJASTHAN | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Highest bid quoted other then L1 | |
| 4 | L4₹24.5 L+₹5.3 L (27.6%)Rejected-Finance | L4 | Rejected-Finance Highest bid quoted other then L1 | |
| 5 | L5₹25.6 L+₹6.4 L (33.5%)Rejected-Finance | L5 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
16 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri GanganagarCantt Rajasthan-335001
PERIODICAL SERVICES AND MAINT OF MD ACCN AREA OF JS, MES COLONY INCLUDING MAP PH-I AND II AT MIL STN SGNR
2024_MES_660306_1
GE SGNR/TOK-23 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
Sri Ganganagar(Raj)
D Class a(i) and for un-enlisted, refer NIT para 8
7 documents required · 7 mandatory
₹500
GE Sri Ganganagar
₹60,000
Yes
6 Sept 2024
18 Jun 2024
18 Jul 2024
18 Jun 2024
16 Jul 2024
2 Jul 2024
Amount
Demolition of RCC , chajjas, Parapet and similar items complete all as specified and directed by Engineer - in - Charge.
Dismantling of brick work or stone/boulder masonry built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed by Engineer - in - Charge.
M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc.complete all as specified and directed by Engineer - in - Charge.
M&L half brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc.complete all as specified and directed by Engineer - in - Charge.
Taking down cement plaster on brick or concrete surfaces of wall/ ceiling including racking out joints, hacking for keys scrubbing down with water complete all as specified directed by Engr-in-Charge.
M&L 15mm thick rendering in cement mortar 1:6 to brick/concrete wall surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L 15mm thick rendering in cement mortar CM 1:4 to brick/concrete wall surfaces finished even & smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L 5mm thick, rendering in cement mortar 1:3 to ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M & L for flush pointing in CM 1:4, to bricks laid flat or brick edge on ,roofs of MAP Ph-I Bldgs having height upto 12.0 mtr complete all as specified and directed by Engineer - in - Charge.
M&L 10 mm thick, rendering in cement mortar CM 1:3 to work in isolated widths or in widths not forming part of general plastering such as brick/concrete faces of chajjas,facia,window jambs,sunshade and similar work exc 15 cm but n exc 30 cm in width or girth; including cutting to edges, all mitres and stopped ends, etc. finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L for fixing of GI wire netting 0.90 mm dia and 12mm mesh lathing by means of fasteners of requierd lenth and spacing beetween fasterners is 300mm centre to centre both way to concrete surface etc,in walls, ceilings, stanchions, beams, etc including all laps, cutting and waste etc complete all as specified and directed by Engineer-in- charge
M&L for 5 mm thick one layer of cement : Coarse sand (1:2) over fixed GI wire netting making good after that rendering 5 mm thick in cement mortar in 1:3 on ceiling complete all as specified and directed by Engineer - in - Charge.
M&L for prepration of New plastered Internal wall surface complete applying the following :- (a) Apply 1.5mm thick wall care putty on wall surfaces and smoothening the surface with sand papers / mechanised sanding etc prepatory to paint as complete all as specified and directed by Engineer - in - Charge. (b) Applying one coat of internal wall primer by using Roller over complet all specified (c) Applying two coats of internal Apcolite Premium Emulsion Roller over complete all as specified and directed by Engineer - in - Charge. Note : Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge in case of places where using Mechanical equiment are not possible
M&L for prepration of New plastered External wall surface complete applying the following :- (a) Applying 1.5mm thick wall putty on wall surface and smoothening the surfcae with sand papers / Mechanised sanding etc prepatory to paint as complete all as specified and directed by Engineer - in - Charge. (b) Applying one coat of Exterior Wall primer by using Roller over completa all as specified (c) Applying two coats of Apex Advanced Dust Proof Emulsion by using Roller over complete all as specified and directed by Engineer - in - Charge. Note : Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge in case of places where using Mechanical equiment are not possible.
M&L for applying two coats of white wash on New plastered ceiling surface to make the surface even and smooth etc complete all as specified and directed by Engineer - in - Charge.
M&L for prepration of old plastered Internal wall surface complete applying the following :- (a) Applying 1.5mm thick wall care putty on wall surfaceonly where for filling depression of surface and nail holes to making even surface. (b) Applying one coats of acrylic Emulsion (incl & up to G+2 floor Qtr) using Roller complete all as specified and directed by Engineer - in - Charge.
M&L for applying one coat of white wash on old decorated surface of ceiling to make the surface even and smooth etc complete all as specified and directed by Engineer - in - Charge.
M&L for complete removal of existing treatment & washing the surface with pressure water on old External/internal wall surface complete all as specified and directed by engineer in charge. Note:- Scraping will be done by mechanical means
M&L for applying two coats of wall care putty on wall suface as per application (a) Applying two coats of 1.50 mm (each coat) thick wall putty on cleaned surface after that grind the surface and clean the surface with broom and prepare the surface for second coat complete all as specified and directed by Engineer - in - Charge.
M&L for applying one coat of primer on prepared surface using roller complete all as specified and directed by Engineer - in - Charge.
M&L applying two coats of interior Apcolite Premium Emulsion by using Roller over primed surface complete all as specified and directed by Engineer-in-charge
M&L for apply two coats of 100% Premium acrylic emulsion exterior paint Apex Advanced Dust Proof Emulsion (incl MAP Qtrs of JS Enclave) using roller surfaces complete all as specified and directed by Engr-in-Charge.
M&L one coat of white wash on old decorated plastered or un-plastered surfaces of wall including prepration of surfaces complete all as specified and directed by Engineer - in - Charge.
M&L for Obliterating old writing of any description, n exc 0.1 sq. m, with paint to match existing work etc complete all as specified and directed by Engineer - in - Charge.
M&L for Writing letters or figures with fluorecent paint ( Block. Roman, Italic or Indian) n exc. 30 cm high etc complete all as specified and directed by Engineer - in - Charge.
M&L for Complete removal existing treatment and Preparation of existing surfaces and applying two coat of cement base paint over a coat of primer on old decorated plastered surface of walls including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
Demolition and breaking up or taking down PVC/AC/CI/SSW 110mm bore pipe drain pipes, complete all as specified and directed by Engineer - in - Charge.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including PVC holding clamps, complete all as specified and directed by Engineer - in - Charge.
S&F 110mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed by Engineer - in - Charge.
S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays for 100mm bore of pipe, including bolts and nuts and securing ends of stays to wall or roof etc complete all as specified and directed by Engineer - in - Charge.
Taking up or down GI tubing 20 mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer - in - Charge.
Ditto- but refixing 20 mm dia ,old steel tubing and connections in new or old possition (wall,ceiling and floors etc) complete all as specified and directed by Engineer - in - Charge.
S&F GI tubing 20 mm bore medium grade galvanise with all fitting as in overflow pipe and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified and directed by Engineer - in - Charge.
Taking down and Refixing old 500 Ltrs capacity Rotational moulded polyethylen water storage tank after cleaning and removing all scale and dirt etc from tanks and from mouths of cirulating pipes etc complete all as specified and directed by Engineer - in - Charge.
S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks triple layered(white coloured) (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including taking down of Old PVC Tank complete all as specified and directed by Engineer - in - Charge.
S&F 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed by Engineer - in - Charge.
S&F in repair 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Dismantling of brick tiles or terracing tiles single layer on roof including also taking down existing APP membrane & disposal of retrieved material upto a distance n.exc 100m where complete all as specified and directed by Engineer - in - Charge.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 100m, complete all as specified and directed by Engineer - in - Charge.
M&L for cement concerete 1:2:4 type B-1 (20 mm graded stone aggrigate) as in filling and mass concerete as in roof padding etc complete all as specified and dirceted by Engineer-In-Charge.
M & L for cleaning of old Roof wall/ concrete surfaces & applied a coat of bituminous primer over cleaned surface @ 0.40 Kg/Sqm followed by a covering coat of Paving bitumen 85/25 grade 1.2 Kg/Sqm. APP modified three layer ploymeric membrane 3mm thick, minimum wt 3.60 kg/Sqm reinforced with polyester non-woven fabric (weighing not less than 150gms/Sqm ) manufactured by M/S STP Ltd/IWL India Ltd or its equivalent, laid as per the manufactures instruction with side over lap of 75mm & end over lap of 100mm & tucked into the chases on vertical surfaces if required complete all as specified and directed by Engineer - in - Charge.
M & L 40mm thick brick tiles bedded in 15mm tick cement mortar (1:6) and joints grouted flush in cement mortar (1:3) and pointed in cement mortar (1:1) mixed with 5% of crude oil by weight of cement complete all as specified and directed by Engineer - in - Charge.
Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 7 to 8mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1 complete all as specified and directed by Engineer-in-Charge.
Note :(i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
PAREEK AND COMPANY
THAKURJI ENTERPRISES
Dashmesh Construction Company
Easyways Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .