Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC AT AMRITPUR PO NB CHILKA VIA BALUGAON DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.2 L+₹1.8 L (11.2%)Rejected-Finance AT AMRITPUR PO INS CHILKA DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹18.6 L+₹2.2 L (13.4%)Rejected-Finance FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹20.2 L+₹3.8 L (23.1%)Rejected-Finance AMRITPUR PO INS CHILKA DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹20.5 L
EMD Value
₹41,000
Closing Date
28 Sept 2024, 6:00 pmClosed
GE CHILKA
GE CHILKA, INS CHILKA, KHURDA, ODISHA 752 037
REPAIR, REPLACEMENT AND MAINTENANCE OF STREET LIGHTS, HIGHMAST LIGHT SYSTEMS, SECURITY PERIMETER LIGHTS AND OTHER ALLIED WORKS IN DOMESTICS/ MD ACCN AREA AND TRAINING AREA AND SWIMMING POOL AT INS CHILKA UNDER GE CHILKA
2024_MES_667574_2
GE/CHL/8970 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GARRISON ENGINEER CHILKA
MES Enlisted contractor of Class E Category b i
7 documents required · 7 mandatory
₹500
Yes
GE CHILKA
₹41,000
Yes
24 Oct 2024
31 Aug 2024
30 Sept 2024
31 Aug 2024
28 Sept 2024
8 Sept 2024
1 Sept 2024 - 6 Sept 2024
Amount
Supply, laying, testing XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm x 4 core including taking down existing cable complete all as specified.Make:- Finolex/ Gloster/ Polycab/Havells Note: The cost of thimbles/lugs and cable gland if incl in quoted rate and no extra payment will be maid for it.
Supply, laying, testing XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm x 4 core including taking down existing cable complete all as specified. Finolex/ Gloster/ Polycab/Havells Note: The cost of thimbles/lugs and cable gland if incl in quoted rate and no extra payment will be maid for it.
Supply, laying, testing XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm x 2 core including taking down existing cable complete all as specified.Make:- Finolex/ Gloster/ Polycab/Havells Note: The cost of thimbles/lugs and cable gland if incl in quoted rate and no extra payment will be maid for it.
Excavation in trenches in any type of soil not exc.1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for laying of underground cableor inside substation for( making cable ducts & cable inside substation) complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick soil after repairing/jointing and laying and testing of cables complete all as specified
Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Supply and fixing HDPE double wall pipe corugated pipe of size 63 mm outer dia for cable protection laid in trenches in lieu of sand/brick protection complete all as specified and directed.
Supply and lay well burnt/Fly ash brick of size 200x100x80mm locallly available as protection of cable in trenches complete all as specifed and as directed by Engineer in charge
M& L for 80 mm dia GI pipe medium grade galvanised including fittings for cable protection and sealing both end including taking down old GI pipe completed all as specified and directed by Engr-in-Charge.
M&L for cutting the existing road / PCC / drain for taking out / laying of underground cable including necessary earthwork excavation and making good to match with the exisitng surface complete all as specified and with PCC 1:3:6 type C1 by (using 20 mm graded stone aggregate) 100mm thick complete all as specified and directed.
S&F in replacement 20 Watt LED decorative post top light fitting of aesthetically designed with symmetrical light distribution, IP 65 Rating 240V, 50 HZ, AC supply and with all accessories as required complete all as specified and as directed of make-CG Cat Part No.LPTH-20-CDL Philips/Havells/Orient
S&F in replacement post top lantern fitting of 40W LED, post-top lantern, aesthetically designed with symmetrical light distribution, IP-65 with all accessories as required complete all as specified and as directed of. make-CG Cat Part No. LPTO-40-CDLor eqvalent in Philips/Havells/Orient
S&F in replacement of 60 Watts LED Street light made up of pressure die cast housing with toughned glass, IP 66 protection and impact resistance of IK07 with symmetrical light distribution and with all accessories as required complete all as specified and as directed of make-CG Cat Part No. TRP-409-60-57-SL-GL-NSG or eqvalent in Philips/Havells/Orient
S&F in replacement of 45 Watts LED, Street light Aerodynamically designedmade up of pressure die cast housing with toughned glass, IP66 protection and impact resistance of IK07 with symmetrical light distribution all accessories complete all as specified and as directed .make-CG Cat Part No. LSTS-45-CDL-M or eqvalent in Philips/Havells/Orient
S&F in replacement 150W LED flood light of die-cast aluminium body, IP66 including all accessories as required complete all as specified and as directed .make-CG Cat Part No. TFS-507-150-57-60D-SL-GL-NSG or eqvalent in Philips/Havells/Orient
S&F in replacement of 250 W LED flood light of die-cast aluminium body, IP66 protection, heat resistant toughened clear glass cover with reflector and all accessories complete with all accessories as required complete all as specified and as directed .make-CG Cat Part No. CFS-506-250-57-60D-SL-GL-NSG or eqvalent in Philips/Havells/Orient
S&F in replacement of 150 W LED Highway light of die-cast aluminium body, IP66 protection, heat resistant toughened clear glass cover with reflector and energy saving envirment friendly light fitting with all accessories as required complete all as specified and as directed make-CG Cat Part No. LBH11-150-CDL/60M or eqvalent in Philips/Havells/Orient
Supply & fixing Garden Bollard light fitting IP 65, rated LED bollard with robust design and efficient light distribution of capacity 10 watt.including provn of necessary nuts,bolts and washers for installation on and connection complete all as specified and directed. make-CG Cat Part No." GTLMP-LUNAR-GRY" or eqvalent in Philips/Havells/Orient
S & F in replacement of 20-28 Watt LED solar street light fitting fixed to existing pole, IP65, Input Volt-DC 6.4V , mono crystalline,lumen -135lm/watts including taking down old fitting complete all as specified. Make:-CG Cat Part No. CSADSPI20CDL or eqvalent in Philips/Havells/Orient
S&F in replacement of 20 mm dia rigid non metallic Unplasticized PVC pipes of pressure rating 10 kgf/sq. cm PVC Conduit inclusive of all tee, bends,reducers, bell mouth tube ends and fixing accessories such as couplers , lock nuts, saddles, pipe hooks etc complete all as specified and as directed.
Supply & Fixing in repair Prestressed concrete pole of 9.0 meters long, 102 mm X 152mm at top and 102 mm x 289mm at bottom, class 10 including two coats of cement base paint and numbering of pole number with white paint complete all as directed. Note :- Excavation , pcc in foundation & PCC coping shall be measured and paid seperately.
M&L for PCC 1:4:8, type D2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete for steel pole complete all as specified.
M&L for PCC 1:2:4, type B1 (using 20 mm graded granite stone aggregate) as in coping for steel pole including necessary formwork complete all as specified.
Supply & Fixing cable junction box of size 205x255x112 mmmade of Poly Carbonate Rectangular Pole Box, Out door type weather proof with metric Knock outs for cable entry including four/five pole terminals and cable entry glands for incomming, out going and connection cable with protection grade IP-66/67 and suitable for LT under ground cable of size 10-16 Sqmm including MCB SP 10 Amps, 10 KA, bracing clamp,bolts,nuts & washers complete all as specified and directed. Make:- Hensel Cat No KF2525b or equivalent in Schneider/GE
S&F in replacement of PVC insulated sheathed multistranded flexible copper conductor cable size 1.5 sqmm x 3 core, drawn through existing conduit / pipe from junction box to fitting complete including taking down old unsv cable all as specified.
S&F in replacement of for Cable straight through joint (epoxy/heat shirnkable) for 10 sqmm to 25 sqmm 4 core PVC insulated and sheathed aluminium conductor under ground cable incl freud , thimbles, nut & bolts, washers etc and testing afterjointing complete all as specified and directed.Make: M-seal/Raychem/Cabseal/Denson
S&F in replacement street light bracket fabricated from 40mm dia medium grade GI pipe 1.5 M long bend to shape as per direction of engg-in charge complete all as specified and as directed. Make of GI pipe :- Tata/Jindal/Prakash Surya
S&F in replacement of clamps suitable for fixing street light on pole fabricated from 32mmx6mm or 25 x 4mm flat iron including nuts, bolts and washers suitable for fixing on poles including applying two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces complete all as specified and as directed.
Supply and fixing in replacement 240V, 10 KA 'C' curve miniaturencircuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. Make: Legrand / ABB / Siemens/ L&T / Indoasian
Supply and fixing in replacement 240V, 10 KA 'C' curve miniaturencircuit breaker (MCB) of double poles and current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning. Make: Legrand / ABB / Siemens/ L&T / Indoasian
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) 40A to 63 A of following poles and current carrying capacity in the DB complete with connection testing and commissioning. Make: Legrand / ABB / Siemens/ L&T / Indoasian
Taking down the existing light fittings on mounting brackets from pole by taking on ground for checking internal wiring/repairs/ replacing the defective parts like electronic drivers,circuit board, connection wires and refixing the same to its original position complete all as specified and directed. Note: (i) Cost of spares , electronic drivers,connection wires replaced against above mentioned item above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (ii) Attending through necessary ladder arrangement on vehicle or ladders etc shall be arranged by the contractor. (iii) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor. (iv) Contractor is completely responsible for the safety of manpower employed by him.(iii) Maintaining proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every flood light/street light and getting it authenticated. (iv) Safety of his men engaged for executing the work along with safety equipment and clothes for the men shall be maintained. Supply only following flood light spares of branded make as mentioned in the list of make enclosed with Particular specifications for replacement :-
Supply only replacement Electronic driver for 250 watts flood lights Make :Crompton/Phillips/Havells/C&S/Bajaj
Supply only replacement Electronic driver for 150 watts flood lights Make Crompton/Phillips/Havells/C&S/Bajaj
Supply only replacement Electronic driver for 60-120watts street lights Make Crompton/Phillips/Havells/C&S/Bajaj
Supply only replacement Surge protection device (SPD) of capacity 10/20 KV compatible with industrail & outdooor LED fixtures Make should be as per the Existing manufacturer
Supply only replacement Metal Core Printed Circuit Board (MCPCB) of capacity 10/20 KV compatible with industrail & outdooor LED fixtures Make should be as per the Existing manufacturer
Supply only replacement Connector with pin suitable for LED Strip outdoor 12 W 24 V IP 68 fittings complete all as specified and directed.
S&F Power contactor 16/18 amps 3 pole a.c. With 230 volts coil Make: L&T/Legrand/Schnider/ABB/Siemens
S&F in replacement of 100 Amps street light power contactor 3 pole, current rating AC3-80A, AC1-100A, 415V, 50 Hz with inbuilt auxilary contactor as required including necessary internal wiring complete all as specified and as directed.Make :- L&T MNX 80 Cat Part No CS97077 or equivalent in Legrand/Schnider/ABB
S&F in replacement of 160 Amps street light power contactor 3 pole, current rating AC3-110A, AC1-160A, 415V, 50 Hz with inbuilt auxilary contactor as required including necessary internal wiring complete all as specified and as directed Make :- L&T MNX 110 Cat Part No CS94137 or equivalent in Legrand/Schnider/ABB
S&F in repairs timelite DB ,32 Amps,3 Pole, 230 Volts,Indoor/Wall mounted type, Consisting with and including Digital Time Switch Astronomical Programmable every 1 minute,backup of 6 years,28 memory locations, Current capacity 16 A, with 1 Changeover ( 1CO ), total 28 programmes complete all as specified and directed. Make- INDOASIAN/ L&T/SECURE/LEGREND.
S&F in repairs Astro Pro Digital timer switch 110-240 volts AC,1 Phase 2W, Base/DIN type 50ON/OFF with 2 change over (CO), 16 amps of Model No: AS2DCDS of GIC or equivalent Make : L&T/ Siemens/Indoasian
Supply and fix in replacement of 12V, 80 AH battery for solar light and size as per existing battery complete all as specified and directed by engr-in-Charge.Make:- Excide/ Luminious/ Amaron
S&F in replacement of 14/15 W LED bulb complete all as specified and as directed. Make :- Crompton Greaves / Havells /Philips
M&L for refilling distilled water in Solar Street Light batteries complete all as specified and as directed. Make : Exide or equivalent as approved
Materials and labour for Preparation of metalic surface with sand paper for street light pole and other steel surface one coat of steel primer and two coats of synthetic enamel paint (post top lantern to apply block colour and Solar street light pole to apply blue colour) and marking of pole numbers serially complete all as specified and as directed by Engr- in-Charge
Materials and labour for preparation of old decorated concrete/plastered surfaces and applying two coats of Cement based paint and marking of pole numbers serially complete all as specified and as directed by Engr- in-Charge
VAIKUNTHA PARIDA (BID ID -3119586)
M/S SOMANATH ENTERPRISES (BID ID -3109352)
PRASANTA KUMAR PANDA (BID ID -3106649)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .