| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.3 LAccepted-AOC | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹47.1 L+₹4.1 L (9.49%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹47.3 L+₹4.3 L (9.91%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹48.1 L+₹5.1 L (11.8%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | L5₹49.7 L+₹6.6 L (15.4%)Rejected-Finance | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
13 Sept 2022, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIRS TO LEAKAGE SEEPAGE OF ROOF AND SUNKEN FLOOR AND OTHER B/R WORKS IN SINGLE OFFRS JCOS ORS ACCN IN ZONE A INCLUDING REPAIR MAINTAINACE AND OVER HAULING OF DG SETS OF CAPACITY 7.5 TO 320 KVA AT GMS UNDER GE I GOS
2022_MES_547229_1
8000/19/2022-23/0918/E8
Open Tender
Civil Works
Item Rate
270 days
GOPALPUR-ON-SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹52,000
Yes
20 Oct 2022
24 Aug 2022
15 Sept 2022
24 Aug 2022
13 Sept 2022
7 Sept 2022
Amount
Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified & directed.
M&L for removing demolished material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified & directed.
M&L for Cleaning the concerned RCC surface by means of wire brush to expose the concrete surface which should be free from all loose particles, dust, laitance, etc complete all as specified & directed.
M&L for Making corner fillets with Polymer modified cementitious (PMC) mortar (PMC:C:M :: 1:2:4 by weight) at all joints of horizontal and vertical surface and doing bore packing with PMC mortar complete all as specified and directed.
M&L for the joints of pipes and concrete/masonry are to be sealed with epoxy putty or epoxy mortar (PMC:C :: 1:2 by weight) and the same is semi-rounded upto 5mm above surface level all along the periphery of PVC pipes complete all as specified and directed.
M&L for application of one coat of Acrylic Polymer Modified Cementitious (APMC) slurry (APMC:C :: 1:2 by weight) coating over the RCC slab surface and carried upto finished floor level on vertical portion (walls) complete all as specified and directed. (Note : This coat is allowed to get dry for 4-6 hours.)
M&L for application of one coat of Acrylic Polymer Modified Cementitious topping rendering (APMC:C:M :: 1:2:2) 1-1.5mm thick over the first coat Acrylic Polymer Modified Cementitious complete all as specified and directed. (Note : This coat is cured for 48 hours.)
M&L for rendering 15mm thick in CM 1:4 on brick or concrete surface, finishing even and smooth using extra cement incl Integral Waterproofing Compound (0.2 % or 100 ml per bag of cement) complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded brick coarse aggregate as in sunken floors etc complete all as specified & directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off premises complete all as specified and directed
M&L in repair Wash down water closet vitreous china white pedestal pattern with 'P' or 'S' trap including connecting to outgoing drain pipe & to flushing pipe excluding flushing cistern and flush pipe complete all as specified and directed.
S&F in repairs plastic water closet seat cover, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S & F in repair CP Jet spray for 15 mm bore all as specified and directed.
M&L in repairs vitreous china squatting pan , ‘Orissa’ Pattern, size 580 X 440 mm white, with integral foot rests etc. complete all as specified and directed.
S&F in repairs, PVC valveless syphonic action type low level flushing cistern, 10 ltrs capacity with inlet, ball valve, float and handle including bracket complete all as specified and directed.
S & F in repair internal fitting for low level flushing cistern (Syphon) complete all as specified and directed.
S&F in repairs flush pipe 32 mm dia of polyethylene of low or high density or PVC, for low level cistern complete all as specified and directed.
S & F in repairs Hand shower (Health faucet) with 1 mtr long Easy flex tube in crome finish & wall hook of approved quality complete all as specified and directed.
M&L in repairs for vitreous china wash basin, white,flat back, size 550 x 400 mm including supply & fixing of brass chromium plated coupling 32 mm etc complete all as specified and directed.
S&F in repair pillar tap cast copper alloy with capstan head chromium plated crewed down high pressure with or without lettered hot or cold with long screwed sharks and ply nuts 15 mm dia complete all as specified and directed
S & F in repair bottle trap chromium plated for WHB as per approved quality complete all as specified & directed.
S&F in repair PVC waste pipe for WHB etc complete all as specified & directed.
S&F in repairs 32 mm bore dia waste coupling of (min weight 32 mm-45 gm of PTMT) (half or full threaded) etc complete all as specified and directed
S&F in repair CP grating 100 mm dia with waste hole (minimum weight 40 gm) complete all as specified and directed
S&F in repair PVC connection 15 mm bore, 450 mm long complete with both ends unions complete all as specified and directed.
S & F in repair 75 mm PVC(SWR) floor trap with grating incl jointing with solvent cement complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 25 mm bore of pipe complete all as specified and directed.
S & F 15 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified & directed.
S & F 20 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified & directed.
S & F 25 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified & directed.
Making connection of PPR distrubtion branch with PPR main of following outer dia of pipe 16 to 40mm size by providing and fixing tee including cutting and making fusion joint etc complete all as specified & directed.
Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in Bricks/ stone Masonary wall complete all as specified and directed.
S&F in repair, 15 mm bore stop cock, cast copper alloy with long shank and cup (concealed type) fancy type chromium plated screwed down high pressure with crutch & butterfly handle screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 15 mm bore stop cock, cast copper alloy screwed down high pressure with crutch & butterfly handle fancy type chromium plated screwed both ends for iron pipe and fixed complete all as specified and directed
S & F in repair Brass chromium plated wall mixer non-telephonic shower arrangement with connecting legs & wall flanges for 15 mm bore of pipe complete all as specified & directed.
S & F in repair Brass chromium plated hole bidet mixer (Basin mixer) with pop-up waste system with 300 mm long braided hoses complete all as specified & directed.
S&F in repair 15 mm bore angle stop cock, cast copper alloy screwed down high pressure with crutch & butterfly handle fancy type chromium plated screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair Chromoium plated Two-way angular stop cock for 15 mm bore of approved quality complete all as specified and directed.
S&F in repair bib taps 15 mm bore, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed
S & F in repair Soap dish any type fixed to plug with chromoium plated brass screw of approved quality complete all as specified and directed.
S & F in repair Corner Glass Shelf with brackets of approved quality complete all as specified and directed.
S & F in repair chromium plated Towel ring with bracket of approved quality complete all as specified and directed.
S&F in repairs CP anodised tubular Towel rail, 20 mm dia, D type, 60 cm long between flanges etc complete all as specified and directed.
S&F in repair single door PVC Cabinet Mirror of size 350 mm x 450 mm with internal shelves complete all as specified & directed.
S & F in repair Toilet Paper Holder with Flap of approved quality complete all as specified and directed.
S & F in repair sheet Glass Shelf assembly consisting of 5.5 mm glass sheet shelf 12 cm wide with cromium plated bracket guard and railing 60 cm long complete all as specified and directed..
Taking down shutter of any description exceeding 1 sqm but not exiding 2 Sqmeach leaf and refixing, in same opening after easing and adjusting building hard ware etc complete all as specified and directed
M&L in repairs Water proofing treatment on "Non approachable / non accessible and approachable roof" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment, properly cleaning & drying the concrete surfaces complete all as specified and directed. (i) Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm(ii) Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm incl cleaning surfaces.(iii) Laying unrolled over the bitumen coated surface, polymeric water proofing membrane Hyperplas standard wt not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction.(iv) Applying two coats of bituminous aluminium paint including preparation complete all as specified & directed.
M&L for PCC 1:1.5:3 type A0 (Using 12.50 mm graded stone aggregate) in roof padding/kerbs/sunken slab etc complete all as specified and directed,
M&L 10 mm thick rendering on roof surfaces/ concrete surface in CM 1:3 finishing even and smooth complete all as specified and directed.
Taking down rain water pipe of any size or pattern incl all fitting head,shoe,band,swan neck etc complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F 110mm in repairs bore PVC (SWR) vent cowl complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F PVC stack clamps to walls or roof for 75 mm bore of pipe etc complete all as specified and directed.
S&F PVC stack clamps to walls or roof for 100 mm bore of pipe etc complete all as specified and directed.
S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 litres capacity hoisted and fixed in position including dismantling of old u/s water tank and removing to store complete all as specified and directed
S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 1000 litres capacity hoisted and fixed in position including dismantling of old u/s water tank and removing to store complete all as specified and directed
S&F ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed.
S&F ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed.
S&F in repairs ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed.
S&F in repairs ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed.
M&L for Disconnecting existing tanks 500 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed.
M&L for Disconnecting existing tanks 1000 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed.
S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed.
S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed
S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends (ISI marked) for Iron/ PP-R pipe of 20 mm bore dia of pipe complete all as specified and directed.
S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends (ISI marked) for Iron/ PP-R pipe of 25 mm bore dia of pipe complete all as specified and directed.
M&L Cutting holes into or through brick walls built in mud mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required superficial area n exc 150 sqcm complete all as specified and directed.
Demolition of brickwork built in cement or cement lime mortar including all quoins, arches pillar etc complete all as specified and directed.
M&L Brick work with flyash bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Demolition of RCC of any description and in any position not other wise specially provided for reinforcement cut as required to facilitate demolition complete all as specified and directed.
M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed.
Taking down cement or cement lime plaster, of any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered wall surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed
M&L for applying two coats of oil bound distemper on wall or concrete surfaces over & including a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed.
M & L for two coats of cement based paint over a coat of primer on new plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and apply three coat of white wash complete all as specified and directed.
S&F in replacement oil filter suitable for 7.5 to 30 KVA DG set capacity as per existing size complete all as specified and directed
All as per item. 97 above but 40 to 82.5 KVA capacity
All as per item 97 above but 100 to 320 KVA capacity
S&F in replacement diesel filter suitable for 7.5 to 30 KVA DG set capacity as per existing size complete all as specified and directed
All as per item. 100 above but 40 to 82.5 KVA capacity
All as per item 100 above but 100 to 320 KVA capacity
S&F in replacement fan belt suitable for DG set of 7.5 to 82.5 KVA capacity complete all as specified and directed ,
All as per item 103 above but 100 to 320 KVA capacity
M&L for draining out oil from engine of DG set of any capacity, cleaning the oil chamber, supply and filling of lubricant in replacement GENSET OIL multi-grade 20W40 complete all as specified and directed.
S&F in replacement of coolant suitable for DG sets complete all as specified and directed.
Checking and inspecting of the DG set Metering AMF panel board system throughly, including removing of the unserviceable damaged control coiling,rewiring of the same with suitable size and carried out of necessary painting matching with existing colour including tightining for all the loose contacts, reconnecting back and testing complete all as specified & directed.
S & F rotating rectifier unit diode kit suitable for 30 KVA to 82.5 KVA DG set by taking out the unserviceable rectifier from excitation system and fixing and connecting, starting and testing on load complete all as specified & directed.
S & F rotating rectifier unit diode kit suitable for 100 KVA to 320 KVA DG set by taking out the unserviceable rectifier from excitation system and fixing and connecting, starting and testing on load acomplete all as specified & directed.
Taking down Unseviceable Digital metering unit of DG set of any capacity and S&F the same as existing make and capacity complete all as specified and directed.
Taking down Unseviceable Engine Relay unit of DG set of any capacity and S&F the same as existing make and capacity complete all as specified and directed.
Routine/general check-up by one skilled technician, complete testing of DG set once in every qtrly at GMS complete all as specified and directed. Note:(minimum maintenance cost up to Rs 300 deemed included in unit rate)
S&F in replacement of battery 12 Volts 180 Ah complete all as specified and directed
S&F in replacement of battery 12 Volts 150 Ah complete all as specified and directed
S&F in replacement of battery Copper Lead Cable with brass thumble complete all as specified and directed
Dismantlling the unserviceable hose pipe with tightning clamps S&F in replacement of the same size hose with clamp complete all as specified and directed
S & F 3 pole power contactor with 2 NO+2NC capacity 110 AMPs
S & F 3 pole power contactor with 2 NO+2NC capacity 185 AMPs
S & F 3 pole power contactor with 2 NO+2NC capacity 250AMPs
S & F 3 pole power contactor with 2 NO+2NC capacity 300 AMPs
S & F 3 pole power contactor with 2 NO+2NC capacity 400A MPs
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position for the capacity of DG set 7.5 KVA to 30 KVA complete all as specified & directed.
All as per item 122 above but 40 to 82.5 KVA capacity
All as per item 122 above but 100 to 320 KVA capacity
Replacement of existing unsv air cleaning element inner with necessary 'O' rings for the DG sets ofcapacity 7.5 KVA to 82.5 KVA as that of existing make and model .
Replacement of existing unsv air cleaning element inner with necessary 'O' rings for the DG sets ofcapacity 100 KVA to 320 KVA as that of existing make and model .
Dismantling radiator of 7.5 to 30 KVA DG Set complete from engine mounting frame, opening and clearing with use of acid, to clear the choked tubes, over hauling of the same, arresting the leakages with soldering, replacing the gasket including replacement of water pump seal, lub oil filter, corrossion resistor filter, reefixing back the radiator in the original position, reconnecting back and testing complete all as specified & directed.
All as per item 127 above but 40 to 82.5 KVA capacity
All as per item 127 above but 100 to 320 KVA capacity
Taking down unserviceable self-starter 12 volts from engine,dismantling and opening of stater and armature,replace the wornout carbon brush,pinion,ignition coil bearing,bushing, including servicing, varnishing of stater after repairing assembling,refixed to same position complete all as specified & directed.
All as per item No.130 above but 24 volts
Dismantling and taking out unserviceable dynamo/alternator of charging unit of battery 12 volts including opening and seviceing of field coil of stator,rotor unit, replace wornout carbon brush,bushes, Bentex pinion complete all as specified and directed.
All as per item No 132 above but 24 volts
M & L for Dismantling, Lifting & transportation of Alternator of DG Set capacity 20 KVA to 82.5 KVA and keeping the core inside oven chamber to removing of moisure and increasing of the insulation value of core and drying the core assembly for minimum 3 days at a temp of 120oC including Re-fixing and alighnment all as specified and directed . Note :- (a) Cost for lifting/lowering the core of Alternator by crane is inclusive. (b) Labour for fixing the connection/removal of connection inside the heating chamber is inclusive. (c) Power consumption for heating core for improving insulation value is inclusive. (d) Temperature 120oC to be maintained and inclusive in rate quoted.
All as per item No. 134 above but 100 to 320 KVA capacity
Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified and directed.
Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer complete all as specified and directed.
Removing excavated material to a distance not exc 50M and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and fix double wall corrugated HDPE pipe 50mm outer dia for protection of UG cable complete all as specified and directed
M&L PCC 1:4:8 type D 2 using 40 mm graded stone aggregate for filling of pole & stay complete all as specified and directed.
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for copining of pole complete all as specified and directed.
M & L for tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 50 mm bore including removing the rusted old one complete all as specified and directed.
Taing out old usserviceable PCC pole of any size and supply and fixing in repairs Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l02mm x 279mm at bottom, class 10 and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of weather proof paint complete all as specified and directed.
Taking out old UNSV and Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for 10 Sqmm 2 Core, including taking down old, complete all as specified and directed.
All as per item No 144 above, but 16 Sqmm 2 Core.
All as per item No 144 above, but 16 Sqmm 4 Core.
M&L for replacement of Earthing complete with GI earth plate 60x60cmx6mm thick electrode and 4mm dia GI wire as earthing lead.burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point complete all as specified and directed.
M&L for replacement of Earthing complete with GI earth plate 60x60cmx6mm thick electrode and using galvanised iron strip 32 x 6 mm as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to iGI strip 32x6 mm as earthing lead means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 100 Amps 16 KA capacity 415V 50Hz with Ics = 50% Icu as per IEC 60947-II suitable for isolation class II front face fixed overload and fixed short circuit setting. taking out the old unserviceable complete all as specified and directed.
Supply and fixing of digital voltmeter 0 to 500 volts 96 x96mm flush type in LT Panels incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of digital ammeter range as per existing 96 x96mm flush type in LT panels incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of LT current transformer ratio from 200/5 Amps or 100/5 or 400/5 in LT panels incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing indicator assembly (RYB) LED type in LT panel boards incl taking out the old unserviceable complete all as specified and directed.
S & F in replacement of new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedde PC coverhaving bottom opening seperate driver compartment with IP 66 protection and impact resistance of IK08 with suitable for pole dia 42 mm of capacity 45 watts complete all as specified and directed. Note :- CA no to be written on the light by the contractor in the quoted rate
S & F in replacement of new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedde PC coverhaving bottom opening seperate driver compartment with IP 66 protection and impact resistance of IK07 with suitable for pole dia 42 mm of capacity 45 watts complete all as specified and directed. Note:- CA No to be written on the light by the contractor in the quoted rate
Supply and fixing in replacement of LED driver for suitable for 45W to 60 W complete all as specified and directed.
Supply and Fix in repair for PVC junction box of size 270 x 225 x 135 mm with Aluminium bus bar 200 Amps capacity -4 No's . MCB SP 6 Amp - 1 No and having provision of cable hole in bottom for two to three armoured cables of size 25 Sqmm 3.5 core, connection box shall be fitted on street light pole and fixing arrrangements i.e. MS clamps etc deemed to be provided by the contractor complete all as specified and directed.
Taking down and replacement of existing unserviceable street light fitting bracket with new brackets made out of 32mm bore GI pipe, light grade, tubing bend to shape, 1.2 metre long, fixed to pole/wall, painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Taking down and replacement of existing unserviceable clamps with new clamps made out of 40x3 mm bending to shape, drilling holes for bolts suitable for fixing GI pipe bracket to steel pole, made in two halves, including nuts, bolts, washers and painting with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed.
M&L for painting steel tubular/ RS Joist/ Rail pole 9 mtrs long alongwith bends with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete all as specified and directed.
M&L for painting PCC pole 9 mtrs long alongwith bends with two coats of weather proof paint and two coats of black bituminous paint over a coat and including marking of pole number with black paint in yellow circle, complete all as specified and directed.
M&L for painting to Timer panel of any size with two coats of sky blue paint over a coat of red oxide primer outerside and two coats of off white paint over a coat of red oxide primer internally complete all as specified and directed. Note: 1. Before painting the contractor will ask for a shut down of the recpective feeder from the JE. 2. While painting of the panels protection of MCCB's and MCB's to be taken care of by the contractor. Any damage occured during the painting will be bear by the contractor.
S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16 to 25 sqmm complete all as specified and directed.
Checking of street/security lights breakdown maint of overhead lines/9 mtr pole/swan neck poles by checking out the cables/carbon removel /connectors/mcbs etc and locating the fault and replacing with necessary cables for jumpers/ clamps & connectors/terminal box etc, making good, cleaning and lubricating the parts etc complete all as specified and as directed Note 1: quoted rate inclusive of vehicle with ladder and manpower job card received from power house and after completion of work job card return to power house . 2. Drivers/PCBs/cables/fittings/terminal box/ disc/pin insulators, are measured and paid separately under relavent items
Supply and fix in replacement of Timer panel, made of MS Enclosure factory made consisting Astronomical timer with max load of 12 KW with 65 A TP contactor with MCB 63 Amp TPN three phase 415 volts conforming to IS/IEC 60947-4-1, provided with protection degree IP 54 with internal wiring FRLS copper cable, in built shor-circuit-protection, class H insulation complete as as specifed and directed. Make Havells, cat part No IHXTS0912A with suiteable size of angle iron frame and necessary PCC Wk complete all as specified and directed.
M&L for taking down the motorised / manual High Mast Lights circular grid accomodating MH/MV light fittings any cap over a ht of 15 mtr to the ground, taking aside, replacing the unsv control gears/ light fittings with LED fixtures and raising back to its original position upto 15 mtr etc complete all as specified and as directed (Rates quoted shall be incl of replacing required accessories where specifically not mentioned but required to complete the Job except LED fixtures)
S&F in replacement astronomical + digital time switch 3 years complete all as specified and directed.
Supply and fix in replacement of automatic modular contactor with 3NO+1NC, 40A, 3 module, 50HZ suitable for timer switch of street light complete all as specified and directed.
Boring of holes horizontally for laying of 40mm dia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed.
Supply and fix post-top lantern 25 watt ruby clear energy saving, environmental friendly, long life aesthetically designed with IP 65 symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed.
M&L in replacement of new generation energy saving and environmental friendly, long, life pressure die cast aluminium housing flood light with PC diffused lens enclusre over LED for glare free light of capacity 120 watts, 240 volts, 50Hz complete all as specified and directed. Note:- CA No to be written on the light by the contractor on the quoted rate
M & L for Cutting and trimming of tree branches 3 mtr all around of any size which is obstructing illumination of street light and touching LT Over head line by using required tools and plants incl removing trimmed tree branches. (Note : Each cleaning will be measured and paid separetely)
Supply and fixing in repairs SP 5-32 amp rating 240V, 10KA 'C' curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing in repairs SPN 32-40 amp rating 240V, 10KA 'C' curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing in repairs TPN 40-100 rating 415, 10KA 'C' curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
S&F in repairs PVC insulated and FR PVC round sheathed copper conductor(flexible), 1100 volts, conforming to IS 694 of size 1.50 Sqmm 3 core complete all as specified and directed
M&L for in repairs service wire sheathed flat 2 core aluminium conductor of size 4 Sqmm, 1100 volts grade complete all as specified and directed
M&L for in repairs service wire sheathed flat 2 core aluminium conductor of size 6 Sqmm, 1100 volts grade complete all as specified and directed
M&L for in repairs service wire sheathed flat 2 core aluminium conductor of size 10 Sqmm, 1100 volts grade complete all as specified and directed
S&F in repairs change over switch off load side handle in enclousre 200A 4 pole 415 Volts complete all as specified and directed
S&F in repairs PVC conduit pipes 19 mm outer dia corrsion free, thermal resistance -5 degree to +60 degree celcius, self extinguishing complete all as specified and directed
S&F in repairs change over switch off load with side handle in enclouser 63A 4 pole 415 volts complete all as specified and directed
Comprehensive maintenance and repairs of electrically operated overhead travelling cranes (EOT) consisting of main girder, cross travel, hoist crab, carriage, long travel drive mechanism, long and cross travel wheel pinions, bearings, rope drum, gear boxes, motors, wire rope, limit switches, overload and time delay relays/resistors, bottom control panels, contactors 3 pole, pendant push button suspension mechanism, etc complete of the EOT Crane 1 Ton to 3 Ton Capacity (Spares/items mentioned herein after shall be paid seperately. Cost of any other spares not included in items herein after shall be borne by the contractor).
Rewinding of 3 phase 415 Volts electric motor of main hoist, creep hoist, long traverse and cross traverse of following capacity with super enamelled copper conductor of gauge as per the existing for the Electric motor above 1 HP but upto and including 5 HP.
Supply only MCB SP 6 to 32 Amps, 240V of EOT cranes
All as per item No 187 above, but MCB two polel 16 to 32 Amps, 240V
All as per item No 187 above, but MCB triple pole 16 To 32 Amps, 240 V (Make : Schnider Eletric,, Havell's, indo asian, L&T)
All as per item No 187 above, but MCB triple pole and neutral 32 to 63 Amps, 240 V (MakeSchnider Eletric,, Havell's, indo asian, L&T)
All as per item No 187 above, but contactors 4 pole 25 Amps, 3Ph, 415V (Make: Schnider Eletric,, L&T, BCH)
All as per item No 187 above, but contactors 4 pole 32 Amps, 3Ph, 415V, (Make: Schnider Eletric,, L&T, BCH)
All as per item No 187 above, but aux contact block for ML Series 1 NO + 1 NC (Make: Schnider Eletric,, L&T, BCH)
All as per item No 187 above, but Illumanated push button switch LED type with accessories (Make Schnider Electric)
All as per item No 187 above, but Cable PVC insulated sheathed with copper conductor of size 4Core 2.5Sqmm with metal hose covered
All as per item No 187 above, but Cable PVC insulated sheathed with copper conductor of size 4Core 1.5Sqmm with metal hose covered
All as per item No 187 above, but Cable PVC insulated sheathed with copper conductor of size1.5 sqmm 16 core
All as per item No 187 above, but Ball bearing of Size 6208/6209.
All as per item No 187 above, but Topping up of Gear box oil 90 Grade Servo in sealed containers.
All as per item No 187 above, but Brake Unit for 100 mm dia for EOT/HOT cranes.
All as per item No 187 above, but Brake Unit for 150 mm dia for EOT/HOT cranes.
All as per item No 187 above, but Steel wire rope of size 10/12 mm dia construction 6x19 Fibre core suitable for EOT/HOT cranes .
All as per item No 187 above, but Over load relay range 4.5 to 6.5 Amps
All as per item No 187 above, but Over load relay range 6 to 8.5 Amps
All as per item No 187 above, but Limit switch 6A roller/lever type for EOT cranes
Carry out load and deflection test for each EOT crane from 1 to 3 TON capacity upto 125% full load with necessary instruments on hoisting, LT/CT for checking the performance of the cranes All as per item No 187 above, but by the engineer In Charge/and upto the users safisfaction. Note: (i) Load/deflection test is to be carried out by the Govt authorized inspector to carry out test in the relevant field in presence of the department rep and recording the test and issue necessary certificate. (ii) The load required for the testing and necessary transportation, will be arranged by the contractor at the location of testing as per ground requirement.
Painting of EOT crane complete with double girder by scraping the old surface and applying on coat of primer with two coat of emulsion paint as per existing colour as per direction of Engr-in-Charge complete all as specified and directed
M/s Bapujee Builders and Traders
M/s M M Engineering Systems
M/s Ats Electricals
M/s MAA BHAIRABI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .