Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC 74 103 DHANKUTTI KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.5 L+₹9,400 (1.27%)Rejected-Finance 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹7.6 L+₹21,875 (2.96%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹8.0 L+₹60,475 (8.19%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹8.4 L+₹1.1 L (14.5%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L5 | Rejected-Finance Being L5 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
1 Aug 2020, 6:00 pmClosed
GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR/ MAINT OF EXTERNAL ELECTRIC SUPPLY, LT,UG CABLE, AND CONNECTED ITEMS AT RV COLONY UNDER GE(I) R AND D KANPUR.
2020_MES_359181_1
8184/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RV Colony GE I R and D Kanpur
AS Per NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹24,000
Yes
30 Dec 2020
9 Jul 2020
3 Aug 2020
10 Jul 2020
1 Aug 2020
17 Jul 2020
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep in soft/loose soil and getting out for cable complete all as specified and directed.
Returning filling of excavated soil after laying the cable with spreading leveling watering and well ramming in layers not exceeding 25cm thick in loose/soft soil complete all as specified and directed.
Removal of surplus soil/excavated material obtained from ground level to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above from the starting point complete all as specified and directed.
Supply & spreading local sand obtained from ganga river in trenches for cable cushioning complete all as specified and directed.
Supply & laying /paving of dry well burnt bricks of sub class ‘B’ laid flat of whole brick over the cable after spreading the sand for cable protection complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, Type 2, flat, size 300mm x 180mm x 40mm over the cable after spreading the sand for cable protection complete all as specified.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) for foundation base complete all as specified and directed.
M&L for PCC(1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) for foundation of pole and stay assembly complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) for coping/finishing of pole foundation and plinth protection complete all as specified and directed.
Supply and fixing GI tubing of 100 mm dia bore, light grade conforming to IS 1239 Part-I and ISI marked fixed alongwith pole and embedded in hardstanding / pillar foundation including breaking /cutting PCC/hard standing not exceeding 20 cm girth or as required at site and making good with cement mortar of ratio 1 :3 complete all as specified and directed.
All as per item no 10 hereinbefore but 50 mm bore.
All as per item no 10 hereinbefore but 25 mm bore.
Cutting & Chasing required on concrete block /path/tile /floor/ wall not exceeding 20 cm girth to concealed the cable/GI wire and making good to disturbed surface with cement mortar 1:3 including facing / finishing where as required to match with existing surfaces complete all as specified and directed.
Takingout unserviceable cable any type from trenches,pole, road,duct etc including necessary joints(U/S)fittings and pipes etc complete all as specified and directed
Supply & laying XLPE insulated, PVC sheathed, strip armoured electric cable with aluminium conductor (stranded) working voltage upto 1100 volt of 185.0 Sqmm x 3.5 core as per IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of alluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed by Eng-in-charge.
Supply & laying XLPE insulated, PVC sheathed, strip armoured electric cable with aluminium conductor (stranded) working voltage upto 1100 volt of 120.0 Sqmm x 3.5 core as per IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of alluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed by Eng-in-charge.
Supply & laying XLPE insulated, PVC sheathed, strip armoured electric cable with aluminium conductor (stranded) working voltage upto 1100 volt of 95.0 Sqmm x 3.5 core as per IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of alluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed by Eng-in-charge.
Supply & laying XLPE insulated, PVC sheathed, strip armoured electric cable with aluminium conductor (stranded) working voltage upto 1100 volt of 35.0 Sqmm x 3.5 core as per IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of alluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed by Eng-in-charge.
Supply & laying XLPE insulated, PVC sheathed, strip armoured electric cable with aluminium conductor (stranded) working voltage upto 1100 volt of 25 Sqmm x 3.5 core as per IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of alluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed by Eng-in-charge.
Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated PVC bedded armored heavy duty electric cable 1100V grade with aluminum conductor of cross sectional are 10 Sq mm 2 core .complete all as specified and directed
M & L for Earthing complete with galvanised steel earthpipe of 3000mm long and 65mmouter x50mm inner dia laid in ground by drilling in the ground as required with filling the back fill compound complete with all as required and directed with 32x6mm GI strip up to testing point and making the earth pit of PCC as per sample as required at site and testing after completion complete all as specified and directed.Make HP earth or eqvt . Note : Earthing strip upto 7.5 metre length shall be deemed to be included in quoted unit rate.
S & F PCC LT cable route marker of size 800mm x 200mm x 150 mm complete all as specified and directed by GE(I)
Providing the cable fault locating Machine with necessary T&P at site for locating exact pin point of fault along with the length of armourd 1.1/ 6.6 /11 KV XLPE/PILCA insulated LT/HT cable complete all as required and directed at site
M&L for cold shrinkable type cable stright through joint outdoor type suitable for XLPE 185 Sqmm 3.5 to 240 sqmm core cable and testing all as specified and directed with terminate joint and jointing material all as specified directed. Make : Denson/ Raychem/ M - seal as approved by GE (I).
M&L for cold shrinkable type cable end joint outdoor type suitable for XLPE 95 Sqmm 3 core cable 11 KV and testing all as specified and directed with joint straight through and jointing material all as specified and directed. Make : Denson/ Raychem/ M - seal as approved by GE (I).
M&L for cold shrinkable type cable end joint indoor type suitable for XLPE 95 Sqmm 3 core cable 11 KV and testing all as specified and directed with terminate joint and jointing material all as specified and directed. Make : Denson/ Raychem/ M - seal as approved by GE (I).
Supply and Fix MCCB optimum 2.1 (Electronic/Microprocessor range with continuously adjustableThermal and Adjustable Magnetic Release, Four Pole, 415 VAC, Current rating- 400 Amps, Breaking capacity ( Ics ) - 50 KA,including suitable size aluminium bus bar for connection complete with extension bus bar of suitable size all as specified and directed by GE (I). Make cat part No 830541of Indo Asian or equivalent of Havells/Legrand / Seimens/Schneider/Hager as approved by GE (I).
Supply and Fix MCCB with continuously adjustableThermal and Adjustable Magnetic Release, Four Pole, 415 VAC, Current rating- 250 Amps, Breaking capacity ( Ics ) - 36 KA, complete all as specified and directed by GE (I). Make cat part No 830433 of Indo Asian /Havells/Legrand / Seimens/Schneider/Hager as approved by GE (I).
Supply and Fix MCCB with continuously adjustableThermal and Adjustable Magnetic Release, Four Pole, 415 VAC, Current rating- 200 Amps, Breaking capacity ( Ics ) - 36 KA,including suitable size aluminium bus bar for connection complete all as specified and directed by GE (I). Make cat part No 830355 of Indo Asianor equivalent of Havells/Legrand / Seimens/Schneider/Hager as approved by GE (I).
Supply and Fix MCCB with continuously adjustableThermal and Adjustable Magnetic Release, Four Pole, 415 VAC, Current rating- 63 Amps, Breaking capacity ( Ics ) - 25 KA,including suitable size aluminium bus bar for connection complete all as specified and directed by GE (I). Make cat part No 830256 of Indo Asian or equivalent of Havells/ Legrand / Seimens/Schneider/Hager as approved by GE (I).
Supply of FR PVC insulated, PVC sheathed flat twin core, solid aluminium conductor cable of size 6 sq mm for voltage grade upto 1100 volt confirming to IS- 694/1990 with latest amendments and ISI marked including removing old connection and making service connections to street light feeder of Make Polycab or its equivalent of EON (Indo Aian) / Havells/ Paragon Electron/ Plaza/Rallison as approved by GE(I).
Supply of Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminiumconductor of 10 sqmm , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular ® to street light feeder of Make Polycab or its equivalent of EON (Indo Aian) / Havells/ Paragon Electron/ Plaza/Rallison as approved by GE(I).
Supply and fixing the electronic energy meter electronic tamper proof design digital technology of three phase 3x240 volts volts 50 HZ 0.4% basic current for direct connected meter and 0.2% of basic current for CT operated meter LCD display class 1 accuracy as per IS 13779 temper proof Microprocessor based single phase energy meter of 10--60 amps /5 amps CT operated with CT with optical communication port with all accessories and including sealing with sealing wire, sealing materials and lead complete and connecting with all accessories all as directed at site. Make HPL socomec model PPEM 01 or equivt havells or as approved by GE
Supply, Errecting and fixing in replacement of in true Vertical position steel tubular swaged pole with iron square belded base plate, finial taper plug, bolt, nuts and screw,weld and reduced section and logitudional weld Seam through out entire length of pole including 2 coats of black bituminious paint through out intrnely and externely up to planting depth and remaining exterior portion of pole with two caot of aluminium paint over a coat of red oxide as specified type 410 SP 31 (9.00 Mtr long) all as specified and directed at site. NOTE - Excavation and Earth work and PCC in foundation shall be measured and paid seprately.
Supply and Fixing mild steel angle of size 50x50x6MM 'B' quality, Gde E-250, fixed independently, without connecting plates complete all as specified and directed. Note :- Excavation and PCC work will be measured and paid for separately under respective items of Schedule 'A'.
Supply and Fixing mild steel angle of size 50x50x6MM 'B' quality, Gde E-250 for Framed work of angle complete, drilled for fixing of steel angle gate to be prepared for hanging with and including hinges fittings and fixing complete all as specified and directed by Engr - In - Charge. Note :- Excavation and PCC work will be measured and paid for separately under respective items of Schedule 'A'.
DEO Traders
BRIGHT TRADRES
M/S PASHUPATI TRADERS
Bharat Sales Corporation
VEE KAY ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .