Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹51.4 L+₹10.0 L (24.1%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Being L2 |
Tender Value
₹60 L
EMD Value
₹1.1 L
Closing Date
3 Sept 2024, 6:00 pmClosed
CWE PATIALA
HQ COMMANDER WORKS ENGINEER BLDG No 26 NEW LALBAGH PATIALA 147001 Contact 01752200082
REPAIR/ MAINTENANCE OF HT DISTRIBUTION SYSTEM INSTALLATION, TRANSFORMER ALONGWITH CONNECTED ITEMS AT MIL STN DAPPAR
2024_MES_664011_1
CWE/PAT/T-12/2024-25
Open Tender
Civil Works
Item Rate
180 days
DAPPAR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
AGE(I) DAPPAR
₹1.1 L
Yes
14 Oct 2024
4 Jul 2024
5 Sept 2024
4 Jul 2024
3 Sept 2024
20 Jul 2024
4 Jul 2024 - 19 Jul 2024
Amount
Material & Labour for dehydration/filtration of transformer oil with mobile transformer filtration plant at site with all required accessories connected to transformer and carrying out filtration of old transformer oil for the desired dielectric strength of 60 KV at 2.5mm gap complete all as specified and as directed.
Material only transformer oil low viscosity EHV grade having 60 KV di-electric strength conforming to IS-335 in original company sealed drum for replacement or topping up to oil level mark at the conservator complete all as specified and as directed.
Disconnecting HT/LT and earth termination connections from transformer, taking down the transformers from plinth/platform and loading into the vehicle; transporting the same to workshop for carrying out necessary repairs and back reconnecting HT/LT connections at site and charging the transformer on load, commissioning and testing including meggar test at site complete all as specified and as directed.
Draining out transformer oil, dismantling top cover alongwith conservator tank, taking out core and coil assemblies after disconnecting connections, rewinding of burnt out HV/LV coil with same size and type of super enamelled copper conductor and number of turns to get the same rating and insulating material such as paper insulator sleeves, heating etc. Putting back the core and coil assemblies into the tank after removing sludge and replacement of HT & LT bushing complete with brass terminal, refixing top cover and conservator including replacement of gasket, nut, bolts & washers (filling new transformer oil having 60 KV dielectric strength and carring out tests as per IS 2026 in presence of Engineer - in - charge for transformer 50 to 100KVA. NOTE : (I) New transformer oil and its filling shall be measured and paid separately under relevant items of schedule.(ii) Cost of rewinding material, insulation material and spares of transformer shall be measured and paid separately under relevant item of Sch .(iii)Replacement of spares will be on required basis complete all as specified and as directed..
All as per item No. 4.00 here-in before but for 100 to 300 KVA
All as per item No. 4.00 here-in before but for 2000 KVA
Material & Labour for rewinding of HT coils with super enamelled copper winding wire of appropriate gauge and proper number of turns to get the same capacity along with insulating materials e.g. leathered paper insulation, cotton tape, empire tape, wooden blocks, PVC sleeves, soldering job, varnishing and heating, drying etc. complete all as specified and as directed.
All as per item No. 7.00 here-in before but of LT coils with super enamelled Class B copper strip with Electrical Grade Insulating Kraft paper all confirming to IEC-60554-3-5 (1984).
Supply & Fix tapping switch (tap changer) 7 positions suitable to vary secondary voltage ± 2.5% to ± 7.5% suitable for transformers of capacity upto 2000 KVA complete all as specified and as directed.
Supply & Fix in replacement bushing insulator made out of good superior quality ceramic, 1.1 kV, suitable for transformers of including 50 to 600 KVA complete all as specified and as directed.
Supply & Fix transformer HV bushing made out of good superior quality ceramic, 11 kV rating, 200 Amps complete all as specified and as directed.
Supply & Fix including with terminal rod made of brass both ends screwed with double washer and brass nut at both ends of superior quality including bushing insulator and gaskets for transformer 50 to 100 KVA complete all as specified and as directed.
All as per item No. 12.00 here-in before but for 100 to 300 KVA
All as per item No. 12.00 here-in before but for 2000 KVA
Material & Labour for replacement of arc horn surge arrester complete with mounting ring, nut bolt etc. of approved make suitable for transformer of rating upto 300KVA complete all as specified and as directed.
Material & Labour for heat shrinkable bus bar protection tubes suitable for 25kV to be applied on rectangular bus bars copper/aluminium after proper cleaning of the bus bar for the complete all as specified and as directed.
Supply & Fix Breather assembly for transformer complete all as specified and as directed.
Supply & Fix Dial type temperature gauge 100 mm dia. with dual calibration in degree Celsius and degree Fahrenheit, range 0 to 50˚c and equivalent degree Fahrenheit complete with capillary tube and sensor complete all as specified and as directed.
Material & Labour for replacement of existing unserviceable silica gel granules with new Self-indicating Orange to Green Silica Gel granules from transformer breather assembly complete all as specified and as directed.
Material & Labour for painting of transformers of rating 50 to 125 KVA with two coats of first quality synthetic enamel paint by spray painting technique after cleaning the body surface of transformer by rubbing with emery paper to remove oil stains, dust, etc. incl. writing SM/ MES numbers complete all as specified and as directed.
All as per item No. 20.00 here-in before but of rating 150 to 300 KVA
All as per item No. 20.00 here-in before but of rating 2000 KVA
Material & Labour for sheet metal work for repair to Transformer LV/HV cable termination box, mounting supports and other misc works, as directed by Engr-n-Charge, all as per existing size and shape of the boxes with 2 mm thick MS sheet duly painted with super enamelled paint - 02 coats over one coat of red oxide primer including necessary cutting, welding, fixing, nuts, bolts, washers, rubber sheets, etc. complete all as specified and as directed.
Supply & Fix inspection glass and gasket of conservator of transformers of capacity 50 KVA to 300 KVA after draining out oil and refilling the same after filtration complete all as specified and as directed.
Material & Labour for replacing unserviceable drain valve 50mm size of various transformers after draining out transformer oil and refilling the oil into the transformer after filtration to get required dielectric strength 60 KV complete all as specified and as directed.
Taking down plastering on lathing (other than wire-netting),without removing lathing,in cement mortar(one side only measured in cases where both sides are plastered).complete all as specified and as directed.
Rendering 15mm thick in Cement mortar 1:4 on one side of lathing complete all as specified and as directed.
Material & Labour for anti-fungus acrylic paint in two coats incl one coat of 100% acrylic primer over newly plastered surface complete all as specified and as directed.
Material & Labour for HT/LT under ground Cable fault detect by under ground cable fault locator including excavation the exact location for repair work and returning filling as existing after repair complete all as specified and directed. Note : contractor shall attend complaint with in 24 hrs & maintenence shall be carried out accordingly for smooth functioning of elect supply cost of the same shall deemed to be included in the above quoted rates.
Material & Labour for Heat shrinkable cable end termination joint including jointing Kit indoor type suitable for earthed 3 core 95/120 sqmm HT 11KV XLPE aluminium conductor cable and HV test after jointing and connecting up complete all as specified and directed.
Material & Labour for Heat shrinkable cable end termination joint including jointing Kit outdoor type suitable for earthed 3 core 95/120 sqmm HT 11 KV XLPE aluminium conductor cable and HV test after jointing and connecting up complete all as specified and as directed.
Material & Labour for extension to HV / LV bushing of transformer of any rating fabricated to required shape and size including drilling, fixing at location inclusive of nuts, bolts and washers and reconnecting the LV / HV cables all as specified and as directed.
Dismantling of earthing PCC chamber complete all as specified and as directed.
Material & Labour for construction of PCC earthing chamber (1:2:4), type B1,using (20mm graded stone aggregate),"mild steel angle iron frame" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle complete all as specified and as directed.
Material & Labour for repair / servicing of marshalling box including spares suitable to 2000 KVA transformer complete all as specified and as directed.
Material & Labour for repair / servicing of OLTC including spares suitable to 2000 KVA transformer complete all as specified and as directed.
Material & Labour for repair / servicing of OLG on load gear box including spares suitable to 2000 KVA transformer complete all as specified and as directed.
Material & Labour for replacement of Auxillary Switch of 2000 KVA transformer complete all as specified and as directed.
Material & Labour for replacement of Tripping Coil of 2000 KVA transformer complete all as specified and as directed.
Supplying, installing, testing and commissioning in replacement of old GODs complete HT 11 kV, 400 Amp Polymer outdoor type gang operated single air-break switch, triple pole, tilting type, vertical mounting, mechanically operated consisting of hot dip galvanised channel iron base having 3 Nos 11 KV Post type insulator in stack - 3 stack per phase, copper or copper alloy high pressure heavily tinned contacts, MS arcing horns capable of breaking the magnetizing current with operating mechanism worked from ground level complete with horizontal connecting square bar, GI pipe of size not less 25mm dia, medium grade and of suitable length as down rod levers coupling & operating handle with locking arrangement connected with new ACSR conductor (jumper) - set of 3 duly logged incoming and out going with steel nut bolts and washers incld. dismantling and taking out old switch and connections complete complying to IS 9921/1985 (Part I to IV) or its latest amendment all as specified and directed by Engr-in-Charge. NOTE - The quoted rate is deemed to be inclusive of cost of cutting, welding, drilling etc. and other jobs incld. cost of nut, bolts, washers, etc. minor items required for the efficient operation of GOD.complete all as specified and as directed.
Supply and install drop out fuse in replacement of old DOs complete, HT 11 kV, 400 Amps fuse link consisting of channel iron base having 1 No 11 KV polymer type insulators in stack & 2 stack per phase complete with fuse carrier of SRBP tube with heavily tinned non ferrous metal parts and spring loaded phosphor bronze contact complete manufactured as per IS 9385 complete all as specified and directed. NOTE - The quoted rate is deemed to be inclusive of cost of cutting, welding, drilling etc. and other jobs incld. cost of nut, bolts, washers, etc. minor items required for the efficient operation of DO fuse unit.
Taking out old unserviceable HT conductor/cable any size complete all as specified and as directed.
Supply, laying in replacement of HT cable/ conductor in trenches /ducts/fixing on pole/STR with suitable size of GI clamps made out of GI strip 32 mm x 6 mm, XLPE insulated, screened, earthed, PVC bedded, galvanised steel strip, electric power cable (heavy duty) of size 3 x 120 sqmm with aluminium conductor suitable for 11 kV (E) grade as per relevent IS including latest amendment for IS testing, commissionong complete all as specified and directed including taking out of old burnt out cable alongwith cable covers. Note:- (a) Earth work, EHV cable cover, sand coushioning & GI pipe will be measured and paid seperately. (b) High voltage test to be conducted at site with suitable voltage before and after laying of HT cable and reading shall be recorded jointly and test report to be submitted in triplicate to the Engineer-in-Charge. The cost of the same shall be deemed to be included in the unit rate quoted above.
All as per item No. 43.00 here-in before but XLPE insulated, screened, earthed, PVC bedded, galvanised steel strip, electric power cable (heavy duty) of size 3 x 150 sqmm with aluminium conductor suitable for 11 KV (E) grade.
All as per item No. 43.00 here-in before but XLPE insulated, screened, earthed, PVC bedded, galvanised steel strip, electric power cable (heavy duty) of size 3 x 185 sqmm with aluminium conductor suitable for 11 KV (E) grade.
All as per item No. 43.00 here-in before but XLPE insulated, screened, earthed, PVC bedded, galvanised steel strip, electric power cable (heavy duty) of size 3 x 95 sqmm with aluminium conductor suitable for 11 KV (E) grade.
All as per item No. 43.00 here-in before but XLPE insulated, screened, earthed, PVC bedded, galvanised steel strip, electric power cable (heavy duty) of size 3 x 240 sqmm with aluminium conductor suitable for 11 KV (E) grade.
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50m in depth for foundation, shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plain and getting out, complete all as specified and as directed.
Material & Labour for sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.). Complete all as specified and as directed. (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes).
Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and as directed.
Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
Factory made unreinforced Precast concrete cable covers class HV type 1, flat, Size 300x180x40mm laid in trenches as protection to cables complete all as specified and as directed.
Dismantling of over head ACSR conductors complete all as specified and as directed.
Supply only aluminium conductor, steel reinforced, of size 6/1 x 2.59 mm (Weasel) straining properly on insulators with and including aluminium tape/winding wire, clamps & jumpers etc. complete all as specified and as directed.. Note : 3% for sag shall be added in measurement
Supply & Fix in replacement Danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 11 kV of size 25 x 20 cm.complete all as specified and as directed.
Dismantling cross arms of Mild Steel channel or angle section etc and setting aside for reuse with in 50 m complete all as specified and as directed.
Material & Labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including painting two coats of aluminium paint over a coat of primer complete all as specified and as directed.
Dismantling of unserviceable insulator any type and any size.complete all as specified and as directed.
Material & Labour for disc insulator porcelain vitreous brown 145 mm height & 225 mm dia ball and socket type two in series assembly with cast aluminium 4 U bolt tension hardware and tension clamps for conductors working pressure HT 11 kV complete all as specified and directed.
Supply only pin type porcelain, vitreous, white, brown or green insulator incl one galvanised mild steel spindle, two galvanised iron washers and one galvansied iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed
Supply & Fix Male contact (gunmetal) suitable for vertical operating type GOD 11 kV grade, 200 Amps rating in position as in replacement including testing and commissioning complete all as specified and as directed.
All as per item No. 61.00 here-in before but Female gunmetal contact.
All as per item No. 61.00 here-in before but Tinned copper flexible jumper.
Material & Labour for fixed type top contact for DO fuse units 11 kV in replacement complete all as specified and directed.
Material & Labour for fixed type bottom contact for DO fuse units 11 kV in replacement complete all as specified and directed.
Dismantling rusted/unsv GI pipe operating handle of any size of GOD complete all as specified and as directed..
Material & Labour for GI pipe of size 25mm dia, medium grade, as down rod levers coupling & operating handle of the existing GOD cut to suitable length including fixing up the same and commissioning of the respective GOD complete all as specified and as directed.. NOTE - The quoted rate is deemed to be inclusive of cost of threading, cutting of pipe incld. cost of nut, bolts, washers, etc. minor items required for the efficient operation of GOD.
Material & Labour for GI pipe 100 mm bore, medium grade laid in trenches / fixed on pole with suitable clamp complete all as specified and as directed.
Material & Labour for servicing, greasing, cleaning of GOD, adjustment of its operation, cleaning and checking (for any type of damage) of insulators and lightening arresters incl. tightening of all loose nuts & bolts on the HT structure at site complete all as specified and directed. NOTE :- 1. All the necessary tools, tackles and ladder shall be arranged by the contractor for the subject work. 2. Contractor has to arrange for necessary cleaning agent (petrol, diesel, CRC 2-26 etc.) and lubricating material like grease, oil and lubricating sprays if any, as required for subject work. 3. Major spares required to be replace during servicing will be measured and paid under relevant item as specified in the schedule hereforth
Material & Labour for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanised iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate),"mild steel angle iron frame" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering and 40mm dia light grade, GI pipe for lead protection in and including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and as directed.
Supply & Fix in repairs earth continuity conductor or main earthing lead fixed to wall on batten or fixed to pole GI strip 32 x 6 mm complete all as specified and as directed.
Supply & Fix in replacement heavy duty station class, Gap less type Metal oxide lightning arrestors, 12 kV of 10kA rupturing capacity complete with all fittings distribution class suitable for 11KV earthed system discharge capacity 65 Kilo Amps complete all as specified and directed. Modifications to support structure as per OEM Requirements shall be the scope of Contractor. No Extra payment will be entertained on this account.
Material & Labour in repairs Heat shrinkable outdoor type end termination cable jointing kit suitable for earthed 3 core 120/185 sqmm HT 11KV XLPE aluminium conductor cable incld. disconnecting concerned cable, cutting out burnt/damaged jointing kit, jointing new kit including testing and commissioning of the cable complete all as specified and as directed. NOTE- (a) The quoted rate is deemed to be inclusive of cost of saddling or clamping of cable all as directed. (b) Contractor has to arrange proper electrical shutdown after informing to depratment concerned.
All as per item No. 73.00 here-in before but 95 sqmm 3 core cable.
All as per item No. 73.00 here-in before but 240 sqmm 3 core cable.
All as per item No. 73.00 here-in before but Heat Shrinkable indoor type end termination cable jointing kit suitable for earthed 3 core 95 Sqmm HT 11 KV XLPE aluminium conductor cable.
All as per item No. 73.00 here-in before but Heat Shrinkable indoor type end termination cable jointing kit suitable for earthed 3 core 120 Sqmm HT 11 KV XLPE aluminium conductor cable.
All as per item No. 73.00 here-in before but Heat Shrinkable indoor type end termination cable jointing kit suitable for earthed 3 core 240 Sqmm HT 11 KV XLPE aluminium conductor cable.
Material & Labour in repairs Heat shrinkable straight through cable jointing kit suitable for earthed 3 core 185/120 sqmm HT 11 kV XLPE aluminium conductor cable incld. disconnecting concerned cable, cutting out burnt/damaged jointing kit, jointing new kit inld. testing and commissioning of the cablecomplete all as specified and as directed. NOTE- (a). The quoted rate is deemed to be inclusive of cost of saddling or clamping of cable all as directed by Engr-in-Charge. (b). Contractor has to arrange proper electrical shutdown after informing to depratment concerned. (c). Cost of connected excavation, soil removal, returning filling in, sand cusshioning and cable covers will be measured and paid in the respective items of the Schedule.
All as per item No. 79.00 here-in before but straight through cable jointing kit suitable for earthed 3 core 95 sqmm HT 11 KV XLPE aluminium conductor cable.
All as per item No. 79.00 here-in before but straight through cable jointing kit suitable for earthed 3 core 240 sqmm HT 11 KV XLPE aluminium conductor cable.
Material & Labour for Anti-climbing device; spikes type square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and as directed.
Material & Labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. NOTE - (a). Cost of cutting out of trench for accomodating the machine and making good to the surface after completion of the job are deemed to be inclusive in the quoted rate. (b). Contractor has to rectify any damage to cables, pipes or other govt. property free of cost to the complete satisfaction of Engr-in-Charge. (c) Any extra excavation or any other connected jobs required other than as mentioned in the scope of work will be measured and paid under the relevant items of this schedule.
Material & Labour for application of aluminium paint two coats after removal of old paint, rust, dust, oil, grease and any other foreign deposits by paint removers or burning off by blow lamps and cleaning with scrapers and chemicals for removal of rust for any number of coats, any width or girth incl. painting five no. strips of 30 cm each on bottom of pole with black and red colour paint, alternately, complete all as specified and as directed. for 2 pole structure.
Material & Labour for writing letters or figures (Block. Roman, Italic or Indian) of 2cm high on any surfaces with any colour paint complete all as specified and as directed.
Supply & Fix ACP (aluminium composite panel) 4 mm thick composed of non combustible virgin LDPE laminated sandwitched between two fine aluminium sheets 0.25mm thick on both sides painted with blue colour polyster paint inclusive of folding and cutting with machine to obtain require shape and size fixing the same on M.S. channels/Poles, wall, etc. with nuts/bolts or screws/anchor fasteners, etc. complete all as specified and as directed.
Material & Labour for loop type insulators, porcelain, vitreous white, brown or green large size, with overall dimentsions 90mm x 140 mm, clearance of hole 25.5 mm complete all as specified and as directed.
Repairs and maintenence of 11 KV 400A HV VCB Crompton make, 50 Hz yearly as under :- (i). Ensuring the switching OFF operation of the VCB positively by racking it out at service position & testing its manual & electrical ON-OFF operations by applying control panel supply source, repair/replacement of the defective components. (ii). After ensuring the VCB is in isolated position, inspection of entire breaker mech parts like, breaker ON OFF operations, mech gear drive assy, closing & tripping mechanisms, spring charging indications, ON-OFF mechanical indications, condition of main closing & tripping spring assy, allied hardwares & it's tightness and alignments. (iii). Inspection of Electrical parts - motor assy, aux block operations, tripping & closing coil operations, main male-female contacts, insulating material, insulating oil healthiness, etc.(iv). Checking operation of relays. (vi). Checking and recording of IR value of VCB trolley and panel.(vii). Checking/repairing/rectification of the control wiring. . (xi). Checking & updating all mech + electrical critical settings of VCB like closing & tripping & trouble free operations. (xii). Checking VCB manual ON-OFF operations by local closing & tripping push assy. (xiii). Checking VCB electrical ON-OFF operations by applying control supply source. VCB should switch ON & OFF by breaker ON-OFF control switch which in installed on control panel. VCB tripping operations to be checked using protection relay units like LSIG realy + master trip realy units + other tripping units installed in the breaker. (xiv). Ensuring if VCB is in trip position, it should not re-close again, even when closing command is applied. (xv). Ensuring VCB's positive & trouble free performance in service position by switching ON the plant load. (xvi). Checking fibre plates, gaskets, , applying properly with LICOM 2 HPCL make/Balmier Lawire make grease or equivalent one using help of grease gun to VCB cradle, racking in-out assy, mech rubbing parts + bushing assy & dry graphite conductive sealant to contacts of PT etc. & re-assembling the same and commissioning complete to the entire satisfaction of Engr-in-Chrg. incld. testing of polarities of CTs. (xvii). High voltage testing with high voltage tester of CT & Breaker pole to with stand working pressure of HT 22 KV to ascertain servicieability and spare parts found defective to be replaced for smooth functioning as directed by Engr-in-Chrg. (xviii). Labour only for opening the busbar chamber of HT board cleaning the bus bar chamber, cleaning of entire dust in side the control panel + VCB by using dry air pressure, inspect the CT's wiring, spout insulator & bus-bar joints & tightening if required & heating up with hot air blower to remove moisture, meggering, HV testing applying TRTPPEX(B) Note : Spares used in this job should be paiid seperately
Supply only Charging Spring Motor as spares of VCB.
Supply only Closing Coil as spares of VCB.
Supply only Tripping Coil as spares of VCB.
Supply only Gear Set as spares of VCB.
Supply only Motor Cut Off Switch as spares of VCB.
Supply only ZZ Switch as spares of VCB.
Supply only LED Indicator as spares of VCB.
Supply only TNC as spares of VCB.
Supply only CT 100/5 as spares of VCB.
Supply only CT 200/5A for incoming as spares of VCB.
Supply only Over current + earth fault relay as spares of VCB. Make : CG Cat Part No CGI 14 C or equivalent.
Supply only PT 11 KV as spares of VCB.
Supply only Numerical Protection relay for incoming as spares of VCB.
Supply only Multifunction Energy meter (as spare of VCB) for measurement of Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh Make : Schneider Cat Part No. METSEEM6400NGRSCL2 or equivalent in HPL/L&T/Ashida Electronics complete as per existing opening. Modification of panel, if any, will be done by the contractor without any extra cost to the govt.
Supply only Fuse of VCB panel
Repairs and maintenence of 11 KV 800A HV VCB Crompton make, 50 Hz yearly as under :- (i). Ensuring the switching OFF operation of the VCB positively by racking it out at service position & testing its manual & electrical ON-OFF operations by applying control panel supply source, repair/replacement of the defective components. (ii). After ensuring the VCB is in isolated position, inspection of entire breaker mech parts like, breaker ON OFF operations, mech gear drive assy, closing & tripping mechanisms, spring charging indications, ON-OFF mechanical indications, condition of main closing & tripping spring assy, allied hardwares & it's tightness and alignments. (iii). Inspection of Electrical parts - motor assy, aux block operations, tripping & closing coil operations, main male-female contacts, insulating material, insulating oil healthiness, etc.(iv). Checking operation of relays. (vi). Checking and recording of IR value of VCB trolley and panel.(vii). Checking/repairing/rectification of the control wiring. . (xi). Checking & updating all mech + electrical critical settings of VCB like closing & tripping & trouble free operations. (xii). Checking VCB manual ON-OFF operations by local closing & tripping push assy. (xiii). Checking VCB electrical ON-OFF operations by applying control supply source. VCB should switch ON & OFF by breaker ON-OFF control switch which in installed on control panel. VCB tripping operations to be checked using protection relay units like LSIG realy + master trip realy units + other tripping units installed in the breaker. (xiv). Ensuring if VCB is in trip position, it should not re-close again, even when closing command is applied. (xv). Ensuring VCB's positive & trouble free performance in service position by switching ON the plant load. (xvi). Checking fibre plates, gaskets, , applying properly with LICOM 2 HPCL make/Balmier Lawire make grease or equivalent one using help of grease gun to VCB cradle, racking in-out assy, mech rubbing parts + bushing assy & dry graphite conductive sealant to contacts of PT etc. & re-assembling the same and commissioning complete to the entire satisfaction of Engr-in-Chrg. incld. testing of polarities of CTs. (xvii). High voltage testing with high voltage tester of CT & Breaker pole to with stand working pressure of HT 22 KV to ascertain servicieability and spare parts found defective to be replaced for smooth functioning as directed by Engr-in-Chrg. (xviii). Labour only for opening the busbar chamber of HT board cleaning the bus bar chamber, cleaning of entire dust in side the control panel + VCB by using dry air pressure, inspect the CT's wiring, spout insulator & bus-bar joints & tightening if required & heating up with hot air blower to remove moisture, meggering, HV testing applying TRTPPEX(B) Note : Spares used in this job should be paiid seperately
Supply only Charging Spring Motor as spares of VCB.
Supply only Closing Coil as spares of VCB.
Supply only Tripping Coil as spares of VCB.
Supply only Gear Set as spares of VCB.
Supply only Motor Cut Off Switch as spares of VCB.
Supply only ZZ Switch as spares of VCB.
Supply only LED Indicator as spares of VCB.
Supply only TNC as spares of VCB.
Supply only PT as spares of VCB.
Supply only CT 100/5 as spares of VCB.
Supply only Over current + earth fault relay as spares of VCB.
Supply only Multifunction Energy meter (as spare of VCB) for measurement of Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh Make : Schneider Cat Part No. METSEEM6400NGRSCL2 or equivalent in HPL/L&T complete as per existing opening. Modification of panel, if any, will be done by the contractor without any extra cost to the govt.
Supply, installing, testing and commissioning factory made HT Bus Bar box Outdoor type platform mounted, suitable for 11000 volts 3 phase , 50 Hz AC supply system fixed at a hight of 4 Ft (2ft under ground and 2 ft above the ground lavel) all as specified and directed having bus bar installed on HT insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet (inner and outer sheet) with front opening type with double door shutter and locking arrangement and stainless steel mannual lock (both type) (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface with aluminium bus bar of rating not less than 400 Amps, breaking capacity of 35KA, IP-54 protection and transparent acrylic sheet of 4mm sheet on both side full covered , on suitable foundation, all as specified and directed
Material & Labour for PCC 1:4:8 Type D-2 using 40 mm graded broken stone aggregate as in mass concrete in foundations etc . complete all as specified and as directed.
Material & Labour for cement concrete 1:2:4 type B - 1 using 20mm graded crushed stone aggregate in coping pedestal to poles including provision of necessary from work finishing the expossed surface even and smooth complete all as specified and as directed.
Dismantling and taking out steel poles/struts/PCC poles of any size complete all as specified and as directed..
Supply and erection of steel tubular swaged poles welded with with cast iron base plate of size 30cmx30cmx6mm thick finial taper plug bolts nuts & screws as specified type 410 SP 55, 11m long in truly vertical position till setting of PCC foundation complete including painting with two coats of aluminium paints of approved quality over one coat of red oxide primer as exposed surface & two coat bitu-mineous paint for embedded portion incl. painting five no. strips upto 30 cm on bottom of the pole with black and red colour paint alternately all as specified and directed. Note :- Excavation of post hole, PCC required for foundation and coping will be measured & paid under relevant items of Sch 'A'.
Material & Labour for complete overhauling, testing, calibrating and commissioning of numerical relay/electro-mechanical relay - 1 UV/OV relay + 1 earth fault/O/C + 1 master trip relay by secondary injection on each multiple settings of relays by injecting artificial load to ascertain correctness completely including primary injection through CTs by injecting artificial load on each multiple setting of relay to check correctness as well setting the relay at the settings which is inco-ordination with the MSEDCL sub-station (source) and as per the further downstream distribution of HV breakers complete all as specified and directed. NOTE - (a). The contractor has to test the functioning/tripping operations of relay caliberated to the complete satisfaction of Engr-in-Charge alongwith the two copies test reports. A total no. of three hard copies and one soft copy (CD) of the reports shall be submitted. (b). The contractor has to arrange for electrical shutdown prior to carry own repairs incld. switching OFF of VCB positively and racking it out at service position.
Supply only Charging Spring Motor as spares of RMU
Supply only Closing Coil as spares of RMU.
Supply only Tripping Coil as spares of RMU.
Supply only Gear Set as spares of RMU.
Supply only Motor Cut Off Switch as spares of RMU.
Supply only ZZ Switch as spares of RMU.
Supply only LED Indicator as spares of RMU.
Supply only Topping up of SF6 gas
Supply only Over current + earth fault relay as spares of RMU
Supply only Auxillary Relay as spares of RMU.
Raman Electric Trading Co (BID ID -3078462)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .