Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹39.2 Cr
EMD Value
₹78.5 L
Closing Date
28 Nov 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer MID Srinagar
Zaldagar, Srinagar, JK, India
Revamping / Modernization of Marval Lift Irrigation Scheme, Pulwama
2025_IFC_295626_1
e-NIT 26
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
1095 days
Budgam Districts
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Executive Engineer MID Srinagar
₹78.5 L
19 Dec 2025
18 Nov 2025
29 Nov 2025
18 Nov 2025
28 Nov 2025
18 Nov 2025
Providing and fitting of FMC steel wire rope 22 mm diameter 6x36 construction having a tensile strength of 1770 N/sqmm as per IS 2266 to be fitted over rope drum and gate pulleys. The cost is inclusive of allied fixtures for fitting the rope as per requirement.
Providing and fitting of chequered plate 06mm thick - 03 nos. at specified locations for walkway on hoist platform.
Painting of the super structures such as gearing & drum covers, couplings, railings, lifting gantries, etc with specified shades of enamel paint (orange/ black) in two coats after applying two coats of steel primer. Job includes surface preparation by scrapping off the old/ loose paint with the help of sand paper/ wire brush, etc.
Spray painting with two coats of synthetic enamel paint of complete distribution panel with RAL 7035 shade (Siemens grey) including two undercoats of steel primer.
Revamping of Main distribution panel by way of the following:
Supplying and laying of 3Cx400 sq.mm XLPE insulated, armoured cable 1100V grade with ISI mark (IS 7098-I), solid/ stranded aluminium conductor of suitable lengths from O/G feeder – Voltage stabilizer – Starter – Motor. The job shall include providing and crimping of 400 sq.mm Aluminium lugs at all cable terminations/ connections.
Supplying and laying of 1Cx400 sq.mm XLPE/ PVC insulated, armoured cable 1100V grade with ISI mark, solid/ stranded aluminium conductor of suitable lengths from L.T side of transformer to main control panel. The job shall include providing and crimping of 400 sq.mm Aluminium lugs at all cable terminations/ connections. The job also includes providing of L.T insulators, clamps and other allied works.
DC supply: Providing, installation, testing and commissioning of DC supply including following main components: i. Battery bank: One set 110V comprising of 55 nos. 2V SMF VRLA batteries of capacity 300AH at 10 hr rate discharge to 1.80 V
per cell at 27 deg C, One set of inter tier connectors for batteries; modular stand and accessories. First filling of the acid and distrilled water shall be supplied at site. ii. Battery charger: 01 no. industrial Float cum boost Battery Charger (30A/ 110V) mounted in a floor mounting type sheet steel cabinet, spray painted with proper ventillation. The battery charger shall have Single pole mains ON/ OFF switch, pilot lamp for mains supply ON, digital ammeter, DC under/ over voltage indicator, Battery reverse polarity indicator, mains fail indicator, overcharging protection, overload protection, I/P & battery overvoltage protection, undervoltage protection, battery low, RS485 port,etc. The charger must be complete with suitable main cord and heavy duty terminal blocks.
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift up-to 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil
Providing/filling of dry-stone soling tightly hand packed under foundation and under floors, including all carriages /head load upto site of work complete.
Providing/ laying in position M7.5 cement concrete mix using graded stone aggregate including all carriages /head load upto site of work complete.
Providing/laying in position M20 reinforced cement concrete mix using graded stone aggregate excluding cost of centering/shuttering etc, but including all carriages /head load upto site of work complete.
Reinforcement for RCC work including straightening, cutting, bending & placing in position & binding complete (using TMT bars) including all carriages/ head load upto site of work complete @ 100kg/cum. Weight = 9.14 x 100 = 914 kg
Providing/laying in position M10 cement concrete mix in trenches using graded stone aggregate excluding cost of centering/shuttering etc, but including all carriages /head load upto site of work complete.
Centering & shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns etc. for mass concrete. (12mm thick water proof ply board) including all the carriages /head load upto site of work complete.
Providing, laying, watering levelling and compacting (GSB Nallah muck) with aggregate size not exceeding 90mm granular sub-base material to specified lines, grades, and density finished work to be measured including carriage of materials by mechanical transport from source of supply upto site of work also includes all leads, lifts, loading, unloading and stacking charges complete.
Structural steel work welded in built up sections, trusses and framed work, doors and windows purlins including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer. i. 12 Nos. Vertical Posts/ Pillars of hollow steel section 150x150x6 ii. Base plate and top plate of vertical posts fabricated from 10mm thick plate welded for pipe reinforcement iii. 02 Nos pedestals to each vertical post for secure anchoring of posts fabricated out of ISA 50x50x5 2 ft long each. iv. Cladding runners of ISA 50x50x5 = (4x40’) + 2(4x13’.6”) + (1x40’) = 308’ v Door frame & door (01 No.) of ISA 50x50x5 = {4x7’} vi Window frame & windows (03 Nos.) of ISA 50x50x5 = {2x4’} each vii. 06 No. of trusses fabricated of double ISA 50x50x5 having rafter of double ISA 65x65x5:- Gusset plates fabricated out of 8mm thick plate viii. Purlins fabricated out of ISMC75x40, 44’ long:- 12 Nos ix. Cleats fabricated of ISA50x6, 0’.6” long:- 60 Nos x. Soffits/ Chajja and Gables out of ISA25x4
Providing and fitting reputed make HI rib profiled sheets suitable for walls and roof of shed, 1000 to 1200mm overall width and total painted thickness of >= 0.5mm.
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Supplying and fixing rolling shutters of approved make, made of required size M.S laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing ball bearings and necessary 27.5cm long wire springs manufacture from high tensile steel wire of adequate strength confirming to IS 4454 part 1 and M.S top cover of required thickness for rolling shutters out of 80x1.20 mm M.S laths with 1.20mm thick top cover, including all the carriages /head load upto site of work complete.
Providing and laying Cement concrete flooring in M15 mix finished with a floating coat of neat cement including cement slurry 50 mm thick with 20 mm nominal size crushed stone aggregate, including all the carriages /head load upto site of work complete.
Providing and applying 20 mm thick cement plaster in 1:4 mix with coarse sand to sides of plinth, ramp and staircase etc, including all the carriages /head load upto site of work complete.
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
Replacement, Providing / Fitting of MS bolts and nuts, washers, spring washers of different size.
Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian oil Servo/HPCL)
BASIC RATE In Figures To be entered by the Bidder Rs. P
Earthing:
Supplying and erection of 33 KV polymeric composite pin insulator 36KV, 10KN, lighting impulse170KV positive and 180KV Negative, creepage distance 900mm with fitting.
Providing and fitting of 33 KV 400A 3-ph Gang operated Air Break Switch
Supplying and erection of single piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. The job also includes lightening arrestor for the pump house.
Supply and erection of horn gap fuse set with post insulators suitable for 33 wire, 33 KV overhead lines.
G.I Nuts & Bolts
Providing and fixing of 'DANGER' plate of standard size for 440V/ 11KV/ 33KV.
Spray painting with two coats of Red Oxide over the surfaces of sub-station poles, channels, and allied things etc.
Providing facilities to pump operators by way of:
Spray painting with two coats of Aluminium Paint after applying the red oxide over the surfaces of sub-station poles, channels, and allied things etc.
B. Commercial Cylinder security, cooktop 2-burner and allied.
C. Blankets
D. Bedding (mattress and quilt, pillow)
Providing and fitting of M.S nuts and bolts (assorted sizes)
"Pumping Unit LL: Replacement of jhonston make 35 cusec vertical mixed flow single stage vertical turbine line shaft type pumping assembly by way of Design, Manufacturing, Supply, retrofitting, testing & commissioning of Vertical Turbine pump lineshaft motor set of specified duty parameters along with column pipe and bowl assembly, discharge head, base channeletc complete as per relevent IS in existing pump bay with specified capacity vertical solid shaft TEFC squirrel cage induction motor of Specifications mentioned in Annexure"A part I of II "
"Sludge pump: Providing and installation of sewage pump of 3-phase 40000 GPH (UK) x 12m head coupled with suitable sized motor. The job includes providing and installation of FASD starter panel with requisite protection devices, suitable cable for electrical connection, canvas hose 6” – 30 mtrs, hose clamps, jointer. The job also includes fitting of necessary devices for SCADA (Supervisary Control and Data Acquisition), RTDs for temperature monitoring and dry run protection." Material of Construction: Impeller – SS; Shafts – SS 410
Revamping of 10-Ton EOHT Crane by way of the following: a. Complete revamping of electrical components including replacement of damaged control wiring, terminal blocks, p/f of pendant switch, etc. and replacement of crane duty contactors. b. Complete servicing/replacement of crane motors, worm gear, etc. c. Providing of U-clamps, bulldog grips, slings, etc as per requirement.
Supply, retrofitting, testing and commissioning of Sluice valve (SCADA compatible) of 600mm size, PN 1.0 generally conforming to IS 14846 or equivalent international standard of following specification: - Material of construction: - Body, Bonnet, Wedge: S.G Iron as per IS 1865 Spindle/Stem: Stainless Steel as per IS 6603 Stem nut, seat ring: High tensile brass The job also includes providing and fitting of rubber gaskets for end connections. Make: VAG/ IVC/ KIRLOSKAR/ TALIS/ AVK/GM/equivalent make
Supply, retrofitting, testing and commissioning of Reflux (Non-Return) valve (SCADA compatible) of 600mm size PN 1.0 generally conforming to IS-5312 or equivalent international standard with latest amendments. Material of construction: - Body, cover, door, hinge: Ductile Iron Hinge pin: SS 304/ SS 316 Body ring, disc face: SS 410 Surface Protection: Electro static epoxy powder coating. The job includes complete replacement of 65mm By-pass arrangement for NRV. Make: VAG/ IVC/ KIRLOSKAR/ TALIS/ AVK/GM/equivalent make
LED frequency meter Class 0.2
Digital VAF + PF meter Class 1 96x96mm with RS485 port
Current transformer 2000/5A - Class 1 - Burden 15VA
Current transformer 800/5A - Class 1 - Burden 15VA
Providing and fitting of LED phase indicator 22.5mm dia with surge protection
Fault annunciation and alarm system comprising of alarm fascia panel with required number of fascia windows, one for each fault and flash type, complete with three push buttons for alarm acceptance resetting and testing & RS485 serial communication port. The individual panels shall be fitted with a common 4-inch size electronic panel hooter
Spray painting with two coats of synthetic enamel paint of complete distribution panel with RAL 7035 shade (Siemens grey) including two undercoats of steel primer.
ACB O/G Panel Supply, retrofitting in panel O/G feeders, testing and commissioning of 800A, 3-Pole ACB (Electrical Draw-out Type) with Microprocessor release having breaking capacity Icu of 50 kA at 415V along with complete control wiring for O/L, S/C, instantaneous, E/F protection release. The job also includes fitting of necessary devices for SCADA (Supervisary Control and Data Acquisition) compatibility.
Supplying and laying of 1Cx400 sq.mm XLPE/ PVC insulated, armoured cable 1100V grade with ISI mark, solid/ stranded aluminium conductor of suitable lengths from L.T side of transformer to main control panel. The job shall include providing and crimping of 400 sq.mm Aluminium lugs at all cable terminations/ connections. The job also includes providing of L.T insulators, clamps and other allied works.
Capacitors Bank HL: Providing and installation of shunt capacitor panel in parallel with motors consisting of following: · Capacitors of total rating 175kVAR · Capacitor duty contractors · MCCB 3P 400A · LED indicators R Y B Suitable size unarmoured aluminium cable for connection.
Ring Spanner set Size (6/7 to 30/32)
Combination spanners 33 to 41
Double ended Spanner Set of Size (12/13 to 40/41)
Combination Pliers, 8 inch, 12 inch: (01 No. each)
Long Nose Pliers 8 inch: (01 No.)
Insulated Screw Driver 10 inch/ 8 Inch/ 6 Inch/ 4 inch: (01 No. Each)
Hammer, 1.3 Kg and 3.6kg: (01 No each)
Pipe Wrench heavy duty type: 300 mm, 450 mm & 600 mm: (01 No. each)
Octagonal Chisels 200mm & 300mm : (01 No. each)
Cantilever tool box 8in x 8in x 20in
Bearing puller (sizes 8 to 10): (01 no. each)
Spirit level 1.0 mm accuracy (900mm): 01 No.
Bench vice fixed type (100mm opening)
Digital Clamp Meter (1000A AC range/ 1000V/ LCD 7 segment display): 01 No. (Meco/Rishabh/ Fluke make)
Vernier Calliper (Digital display 0-150mm): 01 No. (Freemans/ Mitutoyo/ Insize/ equivalent reputed)
Revamping of the Main distribution panel by way of the following:
Aluminium ladder telescopic type 20ft
Fire extinguishers (ABC type) 06 kg capacity as per IS 15683: 06 nos.
Safety gadgets including helmets, gloves, shock proof shoes, etc.
Digital Altimeter/ barometer altitude range upto 8000 Mtr, accuracy: 1m & pressure accuracy 1mbar (Make: BARIGO / HTC)
Capacitors Bank LL: Providing and installation of shunt capacitor panel in parallel with motors consisting of following: · Capacitors of total rating 50kVAR · Capacitor duty contractors · MCCB 3P 160A · LED indicators R Y B Suitable size unarmoured aluminium cable for connection.
Complete earthing of electrical motors, distribution panel, capacitor panel, voltage stabilizers, etc. with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and 20mm GI (medium class) watering pipe 2.7 meter long, funnel etc. with charcoal/ coke and salt as required.
Cable LL: Supplying and laying of 3Cx185 sq.mm XLPE/ PVC insulated, unarmoured cable 1100V grade with ISI mark, solid/ stranded aluminium conductor of suitable lengths from O/G feeder – Voltage stabilizer – Starter – Motor. The job shall include providing and crimping of 185 sq.mm Aluminium lugs at all cable terminations/ connections.
Cable HL: Supplying and laying of 3Cx400 sq.mm XLPE insulated, armoured cable 1100V grade with ISI mark (IS 7098-I), solid/ stranded aluminium conductor of suitable lengths from O/G feeder – Voltage stabilizer – Starter – Motor. The job shall include providing and crimping of 400 sq.mm Aluminium lugs at all cable terminations/ connections.
Engagement of hydraulic excavator for cutting, filling and levelling etc.
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift up-to 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil
Providing/filling of dry-stone soling tightly hand packed under foundation and under floors, including all carriages /head load upto site of work complete.
Providing/ laying in position M7.5 cement concrete mix using graded stone aggregate including all carriages /head load upto site of work complete.
Providing/laying in position M20 reinforced cement concrete mix using graded stone aggregate excluding cost of centering/shuttering etc, but including all carriages /head load upto site of work complete.
Reinforcement for RCC work including straightening, cutting, bending & placing in position & binding complete (using TMT bars) including all carriages/ head load upto site of work complete @ 100kg/cum. Weight = 9.14 x 100 = 914 kg
Providing/laying in position M10 cement concrete mix in trenches using graded stone aggregate excluding cost of centering/shuttering etc, but including all carriages /head load upto site of work complete.
Centering & shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns etc. for mass concrete. (12mm thick water proof ply board) including all the carriages /head load upto site of work complete.
Providing, laying, watering levelling and compacting (GSB Nallah muck) with aggregate size not exceeding 90mm granular sub-base material to specified lines, grades, and density finished work to be measured including carriage of materials by mechanical transport from source of supply upto site of work also includes all leads, lifts, loading, unloading and stacking charges complete.
Structural steel work welded in built up sections, trusses and framed work, doors and windows purlins including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer. i. 12 Nos. Vertical Posts/ Pillars of hollow steel section 150x150x6 ii. Base plate and top plate of vertical posts fabricated from 10mm thick plate welded for pipe reinforcement iii. 02 Nos pedestals to each vertical post for secure anchoring of posts fabricated out of ISA 50x50x5 2 ft long each. iv. Cladding runners of ISA 50x50x5 = (4x40’) + 2(4x13’.6”) + (1x40’) = 308’ v Door frame & door (01 No.) of ISA 50x50x5 = {4x7’} vi Window frame & windows (03 Nos.) of ISA 50x50x5 = {2x4’} each vii. 06 No. of trusses fabricated of double ISA 50x50x5 having rafter of double ISA 65x65x5:- Gusset plates fabricated out of 8mm thick plate viii. Purlins fabricated out of ISMC75x40, 44’ long:- 12 Nos ix. Cleats fabricated of ISA50x6, 0’.6” long:- 60 Nos x. Soffits/ Chajja and Gables out of ISA25x4
Providing and fitting reputed make HI rib profiled sheets suitable for walls and roof of shed, 1000 to 1200mm overall width and total painted thickness of >= 0.5mm.
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing pre coated coloured MS eaves boarding 200mm wide 1.2mm thick including all necessary screws, J or L hooks, nuts with washers all as complete job. Length = (2 x 44’) + 4 x10’ = 128 rft = 39 mtrs
Supplying and fixing rolling shutters of approved make, made of required size M.S laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing ball bearings and necessary 27.5cm long wire springs manufacture from high tensile steel wire of adequate strength confirming to IS 4454 part 1 and M.S top cover of required thickness for rolling shutters out of 80x1.20 mm M.S laths with 1.20mm thick top cover, including all the carriages /head load upto site of work complete.
Providing and fixing by way of welding, drilling, nuts with bolts etc SS window hinges 3” long , door hinges 4” long, window latches, tower bolts, door lock/bolt of reputed make with locking arrangement, 90 mm padlocks (04 Nos), 70 mm padlock (03 Nos) or and other unforeseen items.
Providing and laying Cement concrete flooring in M15 mix finished with a floating coat of neat cement including cement slurry 50 mm thick with 20 mm nominal size crushed stone aggregate, including all the carriages /head load upto site of work complete.
Providing and applying 20 mm thick cement plaster in 1:4 mix with coarse sand to sides of plinth, ramp and staircase etc, including all the carriages /head load upto site of work complete.
"Starter HL: Supply, installation, testing & commissioning of 415 V Fully automatic Microprocessor based 425 H.P soft starter with built in bypass arrangement for pump control application as per specifications mentioned in Annexure "D".
Providing, fitting and installation of 50-watt LED flood lights inside and outside the pump house walls and wherever necessary as per requirement, comprising of brackets and necessary fixtures required for fitting the flood lights etc. Make: BAJAJ/Havells /Philips. (JETA Type or similar as per choice of Department) The job includes wiring of required size & S/W of required amperage.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with piano type switch, phenol laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for heating point 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with switch socket combine, phenolic laminated sheet, suitable size MS box and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Fabrication, providing and fitting of Sub-main panel board of size 2’x2’. The frame of the board shall be fabricated out of 35x35x5mm M.S angle iron and fitted with ply sheet 12mm thick and face covered with ACC sheets. The panel board shall have suitable legs which shall have to be embedded into the pump house wall.
Providing & fitting of 1200mm sweep ceiling fan. (Havells/ Orient/ Bajaj) with controller
Providing & fitting of 300mm sweep metal exhaust fan. (Havells/ Orient/ Bajaj)
LED 12-watt lamps (Havells/ Syska /Wipro/ Philips)
Providing and fitting of service line for electrification of pump house and station premises. The service line shall be 2 Core-16 mm sq. Armoured Aluminium XLPE cable including suitable size & rating of thimbles to be drawn from Electric transformer sub-station/Main panel board to sub-main panel board or as per requirement.
Complete earthing of the electrification of pump house and station premises with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arr
angement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. The job includes providing and laying 6SWG GI wire as earthing conductor.
Providing and fitting of MCBs for electrical circuit with 100A as Incomer, 10A MCBs for lighting circuits of rooms, pump room, floodlighting, store shed, etc, 20A MCB for heating circuits. The MCBs shall be mounted on a MCB distribution box 12-way fitted on panel board for Central control of electrification of pump house and station premises. (MCB makes: Havells/ Legrand/ L&T/ Schneider/ equivalent)
Providing and fitting of 415V 100 Amp. Capacity 4-pole change over switch along with allied wiring for the lighting system of the pump house. The changeover switch shall be of reputed make (Anchor/ Havells/ L&T/ SSK).
Providing and fitting of 7.5 KVA fully automatic Oil-cooled voltage stabilizer ranging from 90-300 Volts giving output voltage of 200-230 Volts. The job also includes P/F of 12-volt DC battery 200 AH (Exide) along with 1100 VA sine wave Inverter (Microtek/ APC/ Sukam make) along with leads terminals and necessary wiring complete in all respects.
"Starter LL: Supply, installation, testing & commissioning of 415 V Fully automatic Microprocessor based 125 H.P soft starter with built in bypass arrangement for pump control application as per specifications mentioned in Annexure "D".
E. Utensils and crockery item
Providing, fitting and installation of 50-watt LED Street lights outside the pump house on light poles wherever necessary as per requirement, comprising of brackets and necessary fixtures required for fitting the street lights etc. Make: BAJAJ/Havells /Philips. (JETA Type or similar as per choice of Department) The job includes wiring of required size & S/W of required amperage.
Replacement, providing/fitting of top cover gasket and gaskets of oil gauge. Replacement, Providing/ fitting of insulating materials such as Press Board, Cotton Tape, Kraft Paper. The job includes cost of all sundry items required.
Replacement, Providing / Fitting of MS bolts and nuts, washers, spring washers of different size.
"Insulation mats Providing and laying at site of high Voltage synthetic insulating mats as floor covering around Electro-mechanical gadgets for safe guarding life and limb of workmen due to possible leakage of current and short circuiting. The mats shall have the following characteristics/technical specifications:" · Confirming to IS -15652-2006 with latest amendments · Thickness- 3.0 mm · Width – 1 Mtr · Length 2 Mtr · Anti- skid Type · Material- PVC Elastomer · Application: suitable for both AC and DC Electric installations. · Class – C · Colour- Black
Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian oil Servo/HPCL)
BASIC RATE In Figures To be entered by the Bidder Rs. P
Earthing:
Supplying and erection of 33 KV polymeric composite pin insulator 36KV, 10KN, lighting impulse170KV positive and 180KV Negative, creepage distance 900mm with fitting.
Providing and fitting of 33 KV 400A 3-ph Gang operated Air Break Switch
300 A single phase IGBT welding machine with lead, holder, clamps, etc. & MS electrodes (10 kg 3.2mm)
Supply and erection of horn gap fuse set with post insulators suitable for 33 wire, 33 KV overhead lines..
G.I Nuts & Bolts
Providing and fixing of 'DANGER' plate of standard size for 440V/ 11KV/ 33KV.
Spray painting with two coats of Red Oxide over the surfaces of sub-station poles, channels, and allied things etc.
Providing and fitting of G.I Nuts & Bolts (assorted size)
Providing facilities to pump operators by way of:
Spray painting with two coats of Aluminium Paint after applying the red oxide over the surfaces of sub-station poles, channels, and allied things etc.
B. Commercial Cylinder security, cooktop 2-burner and allied.
C. Blankets
D. Bedding (mattress and quilt, pillow)
Providing and fitting of M.S nuts and bolts (assorted sizes)
"Pumping Unit LL: Replacement of jhonston make 35 cusec vertical mixed flow single stage vertical turbine line shaft type pumping assembly by way of Design, Manufacturing, Supply, retrofitting, testing & commissioning of Vertical Turbine pump lineshaft motor set of specified duty parameters along with column pipe and bowl assembly, discharge head, base channeletc complete as per relevent IS in existing pump bay with specified capacity vertical solid shaft TEFC squirrel cage induction motor of Specifications mentioned in Annexure"A part I of II "
GI strip for earthing: Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supply, retrofitting, testing and commissioning of Sluice valve (SCADA compatible) of 600mm size, PN 1.0 generally conforming to IS 14846 or equivalent international standard of following specification: - Material of construction: - Body, Bonnet, Wedge: S.G Iron as per IS 1865 Spindle/Stem: Stainless Steel as per IS 6603 Stem nut, seat ring: High tensile brass The job also includes providing and fitting of rubber gaskets for end connections. Make: VAG/ IVC/ KIRLOSKAR/ TALIS/ AVK/GM/equivalent make
Supply, retrofitting, testing and commissioning of Reflux (Non-Return) valve (SCADA compatible) of 600mm size PN 1.0 generally conforming to IS-5312 or equivalent international standard with latest amendments. Material of construction: - Body, cover, door, hinge: Ductile Iron Hinge pin: SS 304/ SS 316 Body ring, disc face: SS 410 Surface Protection: Electro static epoxy powder coating. The job includes complete replacement of 65mm By-pass arrangement for NRV. Make: VAG/ IVC/ KIRLOSKAR/ TALIS/ AVK/GM/equivalent make
LED frequency meter Class 0.2
Digital VAF + PF meter Class 1 96x96mm with RS485 port
Current transformer 2000/5A - Class 1 - Burden 15VA
Current transformer 800/5A - Class 1 - Burden 15VA
Providing and fitting of LED phase indicator 22.5mm dia with surge protection
Fault annunciation and alarm system comprising of alarm fascia panel with required number of fascia windows, one for each fault and flash type, complete with three push buttons for alarm acceptance resetting and testing & RS485 serial communication port. The individual panels shall be fitted with a common 4-inch size electronic panel hooter
Spray painting with two coats of synthetic enamel paint of complete distribution panel with RAL 7035 shade (Siemens grey) including two undercoats of steel primer.
Facelifting and Electrification of pump house, its premises and store shed:
The job further included P/F of Bakelite plate of 25 mm thick of the size 1800mm x 1800mm. The job included cutting of 04 No. groves to the Bakelite plate for placing of the bus bars at equal spaces.
Supplying and laying of 1Cx400 sq.mm XLPE/ PVC insulated, armoured cable 1100V grade with ISI mark, solid/ stranded aluminium conductor of suitable lengths from L.T side of transformer to main control panel. The job shall include providing and crimping of 400 sq.mm Aluminium lugs at all cable terminations/ connections. The job also includes providing of L.T insulators, clamps and other allied works.
Revamping of Main distribution panel by way of the following:
Ring Spanner set Size (6/7 to 30/32)
Combination spanners 33 to 41
Double ended Spanner Set of Size (12/13 to 40/41)
Combination Pliers, 8 inch, 12 inch: (01 No. each)
Long Nose Pliers 8 inch: (01 No.)
Insulated Screw Driver 10 inch/ 8 Inch/ 6 Inch/ 4 inch: (01 No. Each)
Hammer, 1.3 Kg and 3.6kg: (01 No each)
Pipe Wrench heavy duty type: 300 mm, 450 mm & 600 mm: (01 No. each)
Octagonal Chisels 200mm & 300mm : (01 No. each)
Cantilever tool box 8in x 8in x 20in
Bearing puller (sizes 8 to 10): (01 no. each)
Spirit level 1.0 mm accuracy (900mm): 01 No.
Bench vice fixed type (100mm opening)
Digital Clamp Meter (1000A AC range/ 1000V/ LCD 7 segment display): 01 No. (Meco/Rishabh/ Fluke make)
Vernier Calliper (Digital display 0-150mm): 01 No. (Freemans/ Mitutoyo/ Insize/ equivalent reputed)
Aluminium ladder telescopic type 20ft
Fire extinguishers (ABC type) 06 kg capacity as per IS 15683: 06 nos.
33KV CT/PT combined Unit, 3-phase, 50Hz, ONAN cooled, outdoor type. The combined unit, CTs and PTs specification as per requirement. Along with Metering cubicle for 3-phase 4 wire metering system suitable for 3 phase, HT, tri-vector meter with other allied materials like Copper wire, lugs, GI channels, earthing. as per specification approved by KPDCL.
Capacitors Bank LL: Providing and installation of shunt capacitor panel in parallel with motors consisting of following: · Capacitors of total rating 50kVAR · Capacitor duty contractors · MCCB 3P 160A · LED indicators R Y B Suitable size unarmoured aluminium cable for connection.
Complete earthing of electrical motors, distribution panel, capacitor panel, voltage stabilizers, etc. with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and 20mm GI (medium class) watering pipe 2.7 meter long, funnel etc. with charcoal/ coke and salt as required.
Cable LL: Supplying and laying of 3Cx185 sq.mm XLPE/ PVC insulated, unarmoured cable 1100V grade with ISI mark, solid/ stranded aluminium conductor of suitable lengths from O/G feeder – Voltage stabilizer – Starter – Motor. The job shall include providing and crimping of 185 sq.mm Aluminium lugs at all cable terminations/ connections.
Marval Stage 3rd Pumping Unit: Replacement of jhonston make 35 cusec vertical mixed flow single stage vertical turbine line shaft type pumping assembly by way of Design, Manufacturing, Supply, retrofitting, testing & commissioning of Vertical Turbine pump lineshaftmotor set of specified duty parameters along with column pipe and bowl assembly, discharge head, base channeletc complete as per relevent IS in existing pump bay with specified capacity vertical solid shaft TEFC squirrel cage induction motor of Specifications mentioned in Annexure"A part I of II "
Engagement of hydraulic excavator for cutting, filling and levelling etc.
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift up-to 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil
Providing/filling of dry-stone soling tightly hand packed under foundation and under floors, including all carriages /head load upto site of work complete.
Providing/ laying in position M7.5 cement concrete mix using graded stone aggregate including all carriages /head load upto site of work complete.
Providing/laying in position M20 reinforced cement concrete mix using graded stone aggregate excluding cost of centering/shuttering etc, but including all carriages /head load upto site of work complete.
Reinforcement for RCC work including straightening, cutting, bending & placing in position & binding complete (using TMT bars) including all carriages/ head load upto site of work complete @ 100kg/cum. Weight = 9.14 x 100 = 914 kg
Providing/laying in position M10 cement concrete mix in trenches using graded stone aggregate excluding cost of centering/shuttering etc, but including all carriages /head load upto site of work complete.
Centering & shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns etc. for mass concrete. (12mm thick water proof ply board) including all the carriages /head load upto site of work complete.
Providing, laying, watering levelling and compacting (GSB Nallah muck) with aggregate size not exceeding 90mm granular sub-base material to specified lines, grades, and density finished work to be measured including carriage of materials by mechanical transport from source of supply upto site of work also includes all leads, lifts, loading, unloading and stacking charges complete.
Safety gadgets including helmets, gloves, shock proof shoes, etc.
Providing and fitting reputed make HI rib profiled sheets suitable for walls and roof of shed, 1000 to 1200mm overall width and total painted thickness of >= 0.5mm.
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing pre coated coloured MS eaves boarding 200mm wide 1.2mm thick including all necessary screws, J or L hooks, nuts with washers all as complete job. Length = (2 x 44’) + 4 x10’ = 128 rft = 39 mtrs
Supplying and fixing rolling shutters of approved make, made of required size M.S laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing ball bearings and necessary 27.5cm long wire springs manufacture from high tensile steel wire of adequate strength confirming to IS 4454 part 1 and M.S top cover of required thickness for rolling shutters out of 80x1.20 mm M.S laths with 1.20mm thick top cover, including all the carriages /head load upto site of work complete.
Providing and fixing by way of welding, drilling, nuts with bolts etc SS window hinges 3” long , door hinges 4” long, window latches, tower bolts, door lock/bolt of reputed make with locking arrangement, 90 mm padlocks (04 Nos), 70 mm padlock (03 Nos) or and other unforeseen items.
Providing and laying Cement concrete flooring in M15 mix finished with a floating coat of neat cement including cement slurry 50 mm thick with 20 mm nominal size crushed stone aggregate, including all the carriages /head load upto site of work complete.
Providing and applying 20 mm thick cement plaster in 1:4 mix with coarse sand to sides of plinth, ramp and staircase etc, including all the carriages /head load upto site of work complete.
"Starter HL: Supply, installation, testing & commissioning of 415 V Fully automatic Microprocessor based 425 H.P soft starter with built in bypass arrangement for pump control application as per specifications mentioned in Annexure "D".
Providing, fitting and installation of 50-watt LED flood lights inside and outside the pump house walls and wherever necessary as per requirement, comprising of brackets and necessary fixtures required for fitting the flood lights etc. Make: BAJAJ/Havells /Philips. (JETA Type or similar as per choice of Department) The job includes wiring of required size & S/W of required amperage.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with piano type switch, phenol laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for heating point 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with switch socket combine, phenolic laminated sheet, suitable size MS box and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Fabrication, providing and fitting of Sub-main panel board of size 2’x2’. The frame of the board shall be fabricated out of 35x35x5mm M.S angle iron and fitted with ply sheet 12mm thick and face covered with ACC sheets. The panel board shall have suitable legs which shall have to be embedded into the pump house wall.
Providing & fitting of 1200mm sweep ceiling fan. (Havells/ Orient/ Bajaj) with controller
Providing & fitting of 300mm sweep metal exhaust fan. (Havells/ Orient/ Bajaj)
LED 12-watt lamps (Havells/ Syska /Wipro/ Philips)
Providing and fitting of service line for electrification of pump house and station premises. The service line shall be 2 Core-16 mm sq. Armoured Aluminium XLPE cable including suitable size & rating of thimbles to be drawn from Electric transformer sub-station/Main panel board to sub-main panel board or as per requirement.
Complete earthing of the electrification of pump house and station premises with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arr
angement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. The job includes providing and laying 6SWG GI wire as earthing conductor.
Providing and fitting of MCBs for electrical circuit with 100A as Incomer, 10A MCBs for lighting circuits of rooms, pump room, floodlighting, store shed, etc, 20A MCB for heating circuits. The MCBs shall be mounted on a MCB distribution box 12-way fitted on panel board for Central control of electrification of pump house and station premises. (MCB makes: Havells/ Legrand/ L&T/ Schneider/ equivalent)
Providing and fitting of 415V 100 Amp. Capacity 4-pole change over switch along with allied wiring for the lighting system of the pump house. The changeover switch shall be of reputed make (Anchor/ Havells/ L&T/ SSK).
Providing and fitting of 7.5 KVA fully automatic Oil-cooled voltage stabilizer ranging from 90-300 Volts giving output voltage of 200-230 Volts. The job also includes P/F of 12-volt DC battery 200 AH (Exide) along with 1100 VA sine wave Inverter (Microtek/ APC/ Sukam make) along with leads terminals and necessary wiring complete in all respects.
Greasing: Providing and applying multipurpose industrial grease conforming to IS 7623 for crane lifting mechanism, ball bearings, etc. (Castrol/ HPCL/ Champion/ equivalent make)
Tools and other items:
Structural steel work welded in built up sections, trusses and framed work, doors and windows purlins including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete i. 12 Nos. Vertical Posts/ Pillars of hollow steel section 150x150x6 ii. Base plate and top plate of vertical posts fabricated from 10mm thick plate welded for pipe reinforcement iii. 02 Nos pedestals to each vertical post for secure anchoring of posts fabricated out of ISA 50x50x5 2 ft long each. iv. Cladding runners of ISA 50x50x5 = (4x40’) + 2(4x13’.6”) + (1x40’) = 308’ v Door frame & door (01 No.) of ISA 50x50x5 = {4x7’} vi Window frame & windows (03 Nos.) of ISA 50x50x5 = {2x4’} each vii. 06 No. of trusses fabricated of double ISA 50x50x5 having rafter of double ISA 65x65x5:- Gusset plates fabricated out of 8mm thick plate viii. Purlins fabricated out of ISMC75x40, 44’ long:- 12 Nos ix. Cleats fabricated of ISA50x6, 0’.6” long:- 60 Nos x. Soffits/ Chajja and Gables out of ISA25x4
Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian oil Servo/HPCL)
Supply, retrofitting, testing and commissioning of Reflux (Non-Return) valve of 600mm size PN 1.0 generally conforming to IS-5312 or equivalent international standard with latest amendments. Material of construction: - Body, cover, door, hinge: Ductile Iron Hinge pin: SS 304/ SS 316 Body ring, disc face: SS 410 Surface Protection: Electro static epoxy powder coating. The job includes complete replacement of 65mm By-pass arrangement for NRV. Make: VAG/ IVC/ KIRLOSKAR/ TALIS/ AVK/GM/equivalent make
Earthing:
Supplying and erection of 33 KV polymeric composite pin insulator 36KV, 10KN, lighting impulse170KV positive and 180KV Negative, creepage distance 900mm with fitting.
Providing and fitting of 33 KV 400A 3-ph Gang operated Air Break Switch
300 A single phase IGBT welding machine with lead, holder, clamps, etc. & MS electrodes (10 kg 3.2mm)
Supply and erection of horn gap fuse set with post insulators suitable for 33 wire, 33 KV overhead lines..
G.I Nuts & Bolts
Galvanized iron Channel /Angle/ Flat of various sizes including clamps for LA Set/ GO Set, Horn Gap with fitting.
Providing and fixing of 'DANGER' plate of standard size for 440V/ 11KV/ 33KV.
Cement bottoming of poles 1:2:4 mix as per Standards 0.66 cum /pole
Providing and fitting of G.I Nuts & Bolts (assorted size)
Spray painting with two coats of Aluminium Paint after applying the red oxide over the surfaces of sub-station poles, channels, and allied things etc.
100 sq mm ACSR conductor along with all allied fittings including lugs, jumpers, binding tape, nuts & bolts etc as per requirement.
Providing and fitting of aluminum bus bars of the size 100mm x 15mm having 20 meter entire length. The job includes cutting / fitting of the bus bar as per site requirement. Including drilling of holes of the dia 12mm (16 Nos.). The job also includes providing and fitting of 12mm dia bolts along with nuts and washers for fastening of bus bars to the bushes of 1600 KVA HT transform
Providing facilities to pump operators by way of:
Spray painting with two coats of Aluminium Paint after applying the red oxide over the surfaces of sub-station poles, channels, and allied things etc.
B. Commercial Cylinder security, cooktop 2-burner and allied.
C. Blankets
D. Bedding (mattress and quilt, pillow)
O/G Panel Supply, retrofitting in panel O/G feeders, testing and commissioning of 800A, 3-Pole ACB (Electrical Draw-out Type) with Microprocessor release having breaking capacity Icu of 50 kA at 415V along with complete control wiring for O/L, S/C, instantaneous, E
/F protection release. The job also includes fitting of necessary devices for SCADA (Supervisary Control and Data Acquisition) compatibility.
Capacitor Bank: Providing and installation of shunt capacitor panel in parallel with motors consisting of following: · Capacitors of total rating 125kVAR · Capacitor duty contractors · MCCB 3P 400A · LED indicators R Y B Suitable size unarmoured aluminium cable for connection.
Cable:
"Starter: Supply, installation, testing & commissioning of 415 V Fully automatic Microprocessor based 300 H.P soft starter with built in bypass arrangement for pump control application as per specifications mentioned in Annexure "D".
"Insulation mats Providing and laying at site of high Voltage synthetic insulating mats as floor covering around Electro-mechanical gadgets for safe guarding life and limb of workmen due to possible leakage of current and short circuiting. The mats shall have the following characteristics/technical specifications:" · Confirming to IS -15652-2006 with latest amendments · Thickness- 3.0 mm · Width – 1 Mtr · Length 2 Mtr · Anti- skid Type · Material- PVC Elastomer · Application: suitable for both AC and DC Electric installations. · Class – C · Colour- Black
Fabrication, erection of CGI shed of size 41ft x 9ft by way of below mentioned sub-works:
Creation of 1.6 MVA H.T Sub-Station and revamping of existing 1.6 MVA H.T sub-station by way of:
Earthing of Substation -- Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonry with RCC slab cover.
Providing and fitting of M.S nuts and bolts (assorted sizes)
Revamping of mechanical works of delivery side along with supply, retrofitting of 900mm Mild steel flap valve on the exit of delivery pipe line. The job also includes 2 coats of paints.
E. Centring and shuttering including strutting, propping etc. and removal of foam work for o=foundations including strutting, propping etc and removal of formwork
GI strip for earthing: Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supply, retrofitting, testing and commissioning of Sluice valve (SCADA compatible) of 600mm size, PN 1.0 generally conforming to IS 14846 or equivalent international standard of following specification: - Material of construction: - Body, Bonnet, Wedge: S.G Iron as per IS 1865 Spindle/Stem: Stainless Steel as per IS 6603 Stem nut, seat ring: High tensile brass The job also includes providing and fitting of rubber gaskets for end connections. Make: VAG/ IVC/ KIRLOSKAR/ TALIS/ AVK/GM/equivalent make
Supply, retrofitting, testing and commissioning of Reflux (Non-Return) valve (SCADA compatible) of 600mm size PN 1.0 generally conforming to IS-5312 or equivalent international standard with latest amendments. Material of construction: - Body, cover, door, hinge: Ductile Iron Hinge pin: SS 304/ SS 316 Body ring, disc face: SS 410 Surface Protection: Electro static epoxy powder coating. The job includes complete replacement of 65mm By-pass arrangement for NRV. Make: VAG/ IVC/ KIRLOSKAR/ TALIS/ AVK/GM/equivalent make
LED frequency meter Class 0.2
Digital VAF + PF meter Class 1 96x96mm with RS485 port
Current transformer 2000/5A - Class 1 - Burden 15VA
Current transformer 800/5A - Class 1 - Burden 15VA
Providing and fitting of LED phase indicator 22.5mm dia with surge protection
Fault annunciation and alarm system comprising of alarm fascia panel with required number of fascia windows, one for each fault and flash type, complete with three push buttons for alarm acceptance resetting and testing & RS485 serial communication port. The individual panels shall be fitted with a common 4-inch size electronic panel hooter
Spray painting with two coats of synthetic enamel paint of complete distribution panel with RAL 7035 shade (Siemens grey) including two undercoats of steel primer.
Facelifting and Electrification of pump house, its premises and store shed:
Supplying and laying of 3Cx400 sq.mm XLPE insulated, armoured cable 1100V grade with ISI mark (IS 7098-I), solid/ stranded aluminium conductor of suitable lengths from O/G feeder – Voltage stabilizer – Starter – Motor. The job shall include providing and crimping of 400 sq.mm Aluminium lugs at all cable terminations/ connections.
Supplying and laying of 1Cx400 sq.mm XLPE/ PVC insulated, armoured cable 1100V grade with ISI mark, solid/ stranded aluminium conductor of suitable lengths from L.T side of transformer to main control panel. The job shall include providing and crimping of 400 sq.mm Aluminium lugs at all cable terminations/ connections. The job also includes providing of L.T insulators, clamps and other allied works.
Capacitors Bank HL: Providing and installation of shunt capacitor panel in parallel with motors consisting of following: · Capacitors of total rating 175kVAR · Capacitor duty contractors · MCCB 3P 400A · LED indicators R Y B Suitable size unarmoured aluminium cable for connection.
Ring Spanner set Size (6/7 to 30/32)
Combination spanners 33 to 41
Double ended Spanner Set of Size (12/13 to 40/41)
Combination Pliers, 8 inch, 12 inch: (01 No. each)
Long Nose Pliers 8 inch: (01 No.)
Insulated Screw Driver 10 inch/ 8 Inch/ 6 Inch/ 4 inch: (01 No. Each)
Hammer, 1.3 Kg and 3.6kg: (01 No each)
Pipe Wrench heavy duty type: 300 mm, 450 mm & 600 mm: (01 No. each)
Octagonal Chisels 200mm & 300mm : (01 No. each)
Cantilever tool box 8in x 8in x 20in
Bearing puller (sizes 8 to 10): (01 no. each)
Spirit level 1.0 mm accuracy (900mm): 01 No.
Bench vice fixed type (100mm opening)
Vernier Calliper (Digital display 0-150mm): 01 No. (Freemans/ Mitutoyo/ Insize/ equivalent reputed)
Fire extinguishers (ABC type) 06 kg capacity as per IS 15683: 06 nos.
Safety gadgets including helmets, gloves, shock proof shoes, etc.
Digital Altimeter/ barometer altitude range upto 8000 Mtr, accuracy: 1m & pressure accuracy 1mbar (Make: BARIGO / HTC)
Capacitors Bank LL: Providing and installation of shunt capacitor panel in parallel with motors consisting of following: · Capacitors of total rating 50kVAR · Capacitor duty contractors · MCCB 3P 160A · LED indicators R Y B Suitable size unarmoured aluminium cable for connection.
Complete earthing of electrical motors, distribution panel, capacitor panel, voltage stabilizers, etc. with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and 20mm GI (medium class) watering pipe 2.7 meter long, funnel etc. with charcoal/ coke and salt as required.
Cable LL: Supplying and laying of 3Cx185 sq.mm XLPE/ PVC insulated, unarmoured cable 1100V grade with ISI mark, solid/ stranded aluminium conductor of suitable lengths from O/G feeder – Voltage stabilizer – Starter – Motor. The job shall include providing and crimping of 185 sq.mm Aluminium lugs at all cable terminations/ connections.
"Starter HL: Supply, installation, testing & commissioning of 415 V Fully automatic Microprocessor based 425 H.P soft starter with built in bypass arrangement for pump control application as per specifications mentioned in Annexure "D".
Providing, fitting and installation of 50-watt LED flood lights inside and outside the pump house walls and wherever necessary as per requirement, comprising of brackets and necessary fixtures required for fitting the flood lights etc. Make: BAJAJ/Havells /Philips. (JETA Type or similar as per choice of Department) The job includes wiring of required size & S/W of required amperage.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with piano type switch, phenol laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for heating point 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with switch socket combine, phenolic laminated sheet, suitable size MS box and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Fabrication, providing and fitting of Sub-main panel board of size 2’x2’. The frame of the board shall be fabricated out of 35x35x5mm M.S angle iron and fitted with ply sheet 12mm thick and face covered with ACC sheets. The panel board shall have suitable legs which shall have to be embedded into the pump house wall.
Providing & fitting of 1200mm sweep ceiling fan. (Havells/ Orient/ Bajaj) with controller
Providing & fitting of 300mm sweep metal exhaust fan. (Havells/ Orient/ Bajaj)
LED 12-watt lamps (Havells/ Syska /Wipro/ Philips)
Providing and fitting of service line for electrification of pump house and station premises. The service line shall be 2 Core-16 mm sq. Armoured Aluminium XLPE cable including suitable size & rating of thimbles to be drawn from Electric transformer sub-station/Main panel board to sub-main panel board or as per requirement.
Complete earthing of the electrification of pump house and station premises with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arr
angement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. The job includes providing and laying 6SWG GI wire as earthing conductor.
Providing and fitting of MCBs for electrical circuit with 100A as Incomer, 10A MCBs for lighting circuits of rooms, pump room, floodlighting, store shed, etc, 20A MCB for heating circuits. The MCBs shall be mounted on a MCB distribution box 12-way fitted on panel board for Central control of electrification of pump house and station premises. (MCB makes: Havells/ Legrand/ L&T/ Schneider/ equivalent)
Providing and fitting of 415V 100 Amp. Capacity 4-pole change over switch along with allied wiring for the lighting system of the pump house. The changeover switch shall be of reputed make (Anchor/ Havells/ L&T/ SSK).
Providing and fitting of 7.5 KVA fully automatic Oil-cooled voltage stabilizer ranging from 90-300 Volts giving output voltage of 200-230 Volts. The job also includes P/F of 12-volt DC battery 200 AH (Exide) along with 1100 VA sine wave Inverter (Microtek/ APC/ Sukam make) along with leads terminals and necessary wiring complete in all respects.
B. Sand an average lead of 35 Kms
E. Utensils and crockery item
Providing, fitting and installation of 50-watt LED Street lights outside the pump house on light poles wherever necessary as per requirement, comprising of brackets and necessary fixtures required for fitting the street lights etc. Make: BAJAJ/Havells /Philips. (JETA Type or similar as per choice of Department) The job includes wiring of required size & S/W of required amperage.
Replacement, providing/fitting of top cover gasket and gaskets of oil gauge. Replacement, Providing/ fitting of insulating materials such as Press Board, Cotton Tape, Kraft Paper. The job includes cost of all sundry items required.
Replacement, Providing / Fitting of MS bolts and nuts, washers, spring washers of different size.
Greasing: Providing and applying multipurpose industrial grease conforming to IS 7623 for crane lifting mechanism, ball bearings, etc. (Castrol/ HPCL/ Champion/ equivalent make)
Tools and other items:
Structural steel work welded in built up sections, trusses and framed work, doors and windows purlins including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete i. 12 Nos. Vertical Posts/ Pillars of hollow steel section 150x150x6 ii. Base plate and top plate of vertical posts fabricated from 10mm thick plate welded for pipe reinforcement iii. 02 Nos pedestals to each vertical post for secure anchoring of posts fabricated out of ISA 50x50x5 2 ft long each. iv. Cladding runners of ISA 50x50x5 = (4x40’) + 2(4x13’.6”) + (1x40’) = 308’ v Door frame & door (01 No.) of ISA 50x50x5 = {4x7’} vi Window frame & windows (03 Nos.) of ISA 50x50x5 = {2x4’} each vii. 06 No. of trusses fabricated of double ISA 50x50x5 having rafter of double ISA 65x65x5:- Gusset plates fabricated out of 8mm thick plate viii. Purlins fabricated out of ISMC75x40, 44’ long:- 12 Nos ix. Cleats fabricated of ISA50x6, 0’.6” long:- 60 Nos x. Soffits/ Chajja and Gables out of ISA25x4
Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian oil Servo/HPCL)
Supply, retrofitting, testing and commissioning of Reflux (Non-Return) valve of 600mm size PN 1.0 generally conforming to IS-5312 or equivalent international standard with latest amendments. Material of construction: - Body, cover, door, hinge: Ductile Iron Hinge pin: SS 304/ SS 316 Body ring, disc face: SS 410 Surface Protection: Electro static epoxy powder coating. The job includes complete replacement of 65mm By-pass arrangement for NRV. Make: VAG/ IVC/ KIRLOSKAR/ TALIS/ AVK/GM/equivalent make
Earthing:
Supplying and erection of 33 KV polymeric composite pin insulator 36KV, 10KN, lighting impulse170KV positive and 180KV Negative, creepage distance 900mm with fitting.
Providing and fitting of 33 KV 400A 3-ph Gang operated Air Break Switch
300 A single phase IGBT welding machine with lead, holder, clamps, etc. & MS electrodes (10 kg 3.2mm)
Supply and erection of horn gap fuse set with post insulators suitable for 33 wire, 33 KV overhead lines..
G.I Nuts & Bolts
Galvanized iron Channel /Angle/ Flat of various sizes including clamps for LA Set/ GO Set, Horn Gap with fitting.
Providing and fixing of 'DANGER' plate of standard size for 440V/ 11KV/ 33KV.
Cement bottoming of poles 1:2:4 mix as per Standards 0.66 cum /pole
Providing and fitting of G.I Nuts & Bolts (assorted size)
Spray painting with two coats of Aluminium Paint after applying the red oxide over the surfaces of sub-station poles, channels, and allied things etc.
Supply, retrofitting, testing and commissioning of DI Reflux Non-Return valve of 600mm size PN 1.0 generally conforming to IS-5312 or equivalent international standard with latest amendments. Material of construction: - Body, cover, door, hinge: Ductile Iron Hinge pin: SS 304/ SS 316 Body ring, disc face: SS 410 Surface Protection: Electro static epoxy powder coating. The job includes complete replacement of 100mm By-pass arrangement for NRV. Make: VAG/ IVC/ KIRLOSKAR/ TALIS/ AVK/ GM/equivalent make
Providing and fitting of aluminum bus bars of the size 100mm x 15mm having 20 meter entire length. The job includes cutting / fitting of the bus bar as per site requirement. Including drilling of holes of the dia 12mm (16 Nos.). The job also includes providing and fitting of 12mm dia bolts along with nuts and washers for fastening of bus bars to the bushes of 1600 KVA HT transform
Providing facilities to pump operators by way of:
Spray painting with two coats of Aluminium Paint after applying the red oxide over the surfaces of sub-station poles, channels, and allied things etc.
B. Commercial Cylinder security, cooktop 2-burner and allied.
C. Blankets
D. Bedding (mattress and quilt, pillow)
O/G Panel Supply, retrofitting in panel O/G feeders, testing and commissioning of 800A, 3-Pole ACB (Electrical Draw-out Type) with Microprocessor release having breaking capacity Icu of 50 kA at 415V along with complete control wiring for O/L, S/C, instantaneous, E
C. Stone aggregate (20mm) by an average lead of 30 KM
Capacitor Bank: Providing and installation of shunt capacitor panel in parallel with motors consisting of following: · Capacitors of total rating 125kVAR · Capacitor duty contractors · MCCB 3P 400A · LED indicators R Y B Suitable size unarmoured aluminium cable for connection.
Cable:
"Starter: Supply, installation, testing & commissioning of 415 V Fully automatic Microprocessor based 300 H.P soft starter with built in bypass arrangement for pump control application as per specifications mentioned in Annexure "D".
"Insulation mats Providing and laying at site of high Voltage synthetic insulating mats as floor covering around Electro-mechanical gadgets for safe guarding life and limb of workmen due to possible leakage of current and short circuiting. The mats shall have the following characteristics/technical specifications:" · Confirming to IS -15652-2006 with latest amendments · Thickness- 3.0 mm · Width – 1 Mtr · Length 2 Mtr · Anti- skid Type · Material- PVC Elastomer · Application: suitable for both AC and DC Electric installations. · Class – C · Colour- Black
Fabrication, erection of CGI shed of size 41ft x 9ft by way of below mentioned sub-works:
Creation of 1.6 MVA H.T Sub-Station and revamping of existing 1.6 MVA H.T sub-station by way of:
Earthing of Substation -- Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonry with RCC slab cover.
Providing and fitting of aluminum bus bars of the size 100mm x 15mm having 40 meter entire length. The job includes cutting / fitting of the bus bar as per site requirement. Including drilling of holes of the dia 12mm (16 Nos.). The job also includes providing and fitting of 12mm dia bolts along with nuts and washers for fastening of bus bars to the bushes of 1600 KVA HT transformer.
D. Stones by an average lead of 20Km
Marval Stage 4th Providing and replacement of deteriorated section of rising main by MS pipe 900mm ND 10mm thick, ERW. (Grade-FE 410)
11 Mtr. Long Pole (ST-410 SP56)
GI V cross-arm with top Bracket including Clamp
33KV Polymeric composite Pin insulator 36KV, 10KN, Lighting Impulse 170 Positive and 180KV Negative, Creepage Distance 900mm
33KV Polymeric composite Disc insulator 36KV,min falling load 70KN, Lighting Impulse 170 Positive and 180KV Negative, Creepage Distance 900mm with fitting
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing complete by GI Pipe 40mm 3 mtr long through GI Strip 25x3 mm
Red Oxide
Aluminium Paint
Cement Bottoming 1:2:4 mix as per Standards 0.66 cum/pole
Stone Pad (300 mm x 300 mm x 75 mm)
Aluminium Jointing Sleeves
Galvanized Stay Set with 50x8 mm stay clamp, guy insulator (2Nos.), anchor plate (300x300x8) mm, nut bolts, 2 Nos turn-buckles, 1.8m long, 20mm diameter solid GS Stay rod & 7/4mm dia GI Stranded wire complete
SCADA Control Room & staff quarter for mechanical field staff:
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead up to 50 meters and lift up to 1.5 m, as directed by Engineer-in-Charge, in All kinds of soil.
Dumping of dry stone soling excluding cost of stones
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Crushed.
A). PVC Connections for wash basin, Cistern, Geyser etc
Providing and fixing of sanitary fittings and pipe especially like C.P tubes, bends, collar, Cowel, etc.
Carriage of materials by means of mechanical transport from source upto actual site of work including loading, unloading and stacking of materials at site.
Centering and shuttering including strutting, propping etc. and removal of form work for:-
Suspended floors, roofs, landings, balconies and access platforms.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).
Extra over item no. 124.06 towards allowance for form-work
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows of 35 mm fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). Full Panelled Shutters with Kiln seasoned & chemically treated hollock wood.
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. 5.0 mm thick glass pane (weighing not less than 12.50 kg/sqm).
Extra over Item no, 124.05 towards allowance for form-work
Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete.( 75x47x1.70 mm)
Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete of 200x10 mm.
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodized (anodic coating not less than grade AC 10 as per IS : 1868) aluminum lever handles of approved quality with necessary screws etc. complete.
Providing and fixing bright finished brass hard drawn hooks and eyes of 300 mm.
Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M
.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete, 0.80 mm thick with zinc coating not less than 275 gram/m2.
Providing valleys of 90cm wide overall in plain G.S. sheets fixed with polymer coated J. or L. hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete, 1.25 mm thick with zinc coating not less than 350 gram/m2.
Providing and fixing plained eaves boarding, 2nd class kail wood with 250x32 mm (nominal size ).
12mm Cement plaster of mix 1 : 4 ( 1 cement : 4 fine sand)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete of Size of tile 600x600 mm.
Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels ,Granite of any colour or shade .( 18 mm)
Providing and fixing of PVC ( Super heavy with round moulding) panelling lining on wall including cost of nails, screws etc. all carriage upto the site, complete job.
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete, 2 mm thick.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content, With water thinnable cement primer on wall surface having VOC content less than 50 grams/liter.
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm).
Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5sqm per liter per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant.
Applying priming coat With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc complete, On steel work.
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick , Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II IS : 14587 .
Providing and fixing sliding arrangement in racks/cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section (the payment for C or E channel shall be made separately).
Providing and fixing powder coated telescopic drawer channels 300mm long with necessary screws etc. complete as per directions of engineer-in-charge.
Providing and fixing magnetic catcher of approved quality in cupboard/ward robe shutters including fixing with necessary screws etc. complete, Triple strip (Vertical type).
Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete.
Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete, 65mm
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters with 80x1.20 mm M.S. laths with 1.20 mm thick top cover. Complete Job.
Providing and fixing ball bearing for rolling shutters.
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., 25 mm diameter, wherever necessary complete
Supplying and fixing in position the krewal curtains of superior quality and design , as specified and directed by Engineer-in-Charge.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required, Stainless Steel AISI- 304 (18/8) Orissa pattern W.C. pan of size 585x480mm with flush pipe and integrated type foot rests.
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required , White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for
the reception of pipes and fittings.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete, Flexible pipe 32 mm dia.
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge, 15 mm nominal dia.
Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms.
Providing and fixing PTMT grating of approved quality and colour, 150 mm nominal size square 100 mm diameter of the inner hinged round grating.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required, 510x1040mm bowl depth 250mm.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. 20 mm dia. nominal bore, medium.
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work), 20 mm nominal bore.
Providing and fixing 20 mm dia G.I. Elbows
Providing and fixing 20 mm dia G.I. plugs
Providing and fixing 20 mm G.I. Tee (equal)
Providing and fixing 20 mm dia G.I. crosses
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete, 20 mm nominal bore.
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc.
Providing and fixing PVC Sewage Pipe for carriage of sewage of approved brand and specifications (4" & 3") .
B). PVC plain bend 110 mm
C). PVC plain bend 90 mm
D) . PVC Collar 110 mm
E) PVC Collar 90 mm
F). PVC Floor Trap
G). PVC P Trap
H). PVC Door bend
I). PVC Cowel
J) PVC Tee
Making soak pit of cement concrete rings of each 900 mm diameter and 200 mm height 3.0 meter deep with cement concrete lid over top and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design; as directed by engineer in charge.
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 25 Ltr water heater geyser of approved make like , Jaquar, venus, jupiton, Racold or equivalent make including all necessary fittings complete Job.
Providing and fixing of lighting points, 1 lighting point should include wiring for lighting points in 1.5 square mm PVC installed copper wire of approved brand (Havells, Anchor, Finolex) and 2.5 Square mm PVC installed multi standard copper wire for lighting sub mains 6 AMP one way modular switch of approved brand (Havells, GM, Anchor) 2mm thick PVC Conduit / Channels with bends and junction boxes etc 6AMP. Spol DB for housing MCB and Hylam sheets with wooden boxes recessed involved with all accessories of approved brand i.e 15 watts lED Light, also shall include inverter wiring complete Job.
Providing and fixing of heating points, 1 heating poing should include wiring for heating points in 4 square mm PVC installed copper wire and 4 Square mm PVC installed multi standard copper wire of approved brand (Havells, Anchor, FiNolex) for heating sub mains 16 AMP one way modular switch of approved brand (Havells, GM, Anchor) 2mm thick PVC Conduit/Channels with bends and junciton boxes etc 6AMP. Spol DB for housing MCB and Hylam sheets with wooden boxes recessed involved with all accessories of approved brand complete Job.
Providing and fixing of fan point including the fan (Ceiling / Exhaust) One Fan point shall include wiring for fan points in 1.5 Sqmm PVC insulated multi strand copper wire of approved brand (Havells, Anchor, FiNolex); 1200mm ceiling fan / 225mm exhaust fan of approved brand (Havells, Orient, Bajaj) with ceiling roses and PVC square block, 350 watts junction boxes etc, fan control switch, 6 AMP Spol MCB, 10 AMP DB MCB, 2 way DB for housing MCB for lighting circuits and hylam sheets with wooden boxes recessed involves with accessories of approved brand, complete job.
Supply and installation of Exide UPS/Inverter 2.5 KVA along with Exide double battery 200 AH.
Supply and Installation of 7 KVA step up transformer, connecting the mains of reputed make, as per the directions of engineer in charge. (Non Servo type).
Supply, Installation, Testing and commissioning of Air Conditioning System of 1.5 T Capacity with all accessories (Stabilizer, Conduiting, Compressor unit wall stand) of make Diakin, Bluestar, Voltas, Haier, including making requisite holes in the wall and making them good after installation, all complete as specified and directed by engineer in charge.
Sofa 2 Seater Fabric Over all Dimension 1500mm X 900mm X 820mm understructure is made up of pinewood members cross sections 22x64mm, 34x64mm & 16x35mm,Seat is made of PU foam with density 28 kg/m3 with a top layer of supersoft PU foam with density 32 kg/m3. Non woven fabric upholstry is stapled on the seat structure of frame.
Supplying and placing in position the center table (4 feet x 2 feet) made up of solid wood with toughened glass top, as specified and directed by engineer in charge.
Supplying and fixing in position the L-Shaped Executive Office Table of superior quality and design, as specified and directed by engineer in charge.
Providing of high back revolving Officer’s chair with head rest.
Providing and fixing ISI marked
oxidized M.S. handles conforming to IS : 4992 with necessary screws etc. complete of 125 mm.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) with Kiln seasoned and chemically treated hollock wood of ( 5’’ x 3’’)
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required, 0.80 mm thick with zinc coating not less than 275 gram/m2.
Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood).
A. Stone avg. lead of 7 km
Providing of Cushioned office chairs
Supplying and placing in position the steel almirah medium size made up of steel with lock arrangement, shelving, doors, of approved brand as specified and directed by engineer in charge.
Providing and placing in position wall to wall matting of superior quality.
Supply of power cable wire from main supply line upto the structure
Level Transmitter for Sump Compatible to transmit Sump level to PLC system
Power analyzer interfacing to PLC Panel
Pressure Transmitter for Individual and Common Delivery header, compatible to transmit Pressure to PLC System
Non redundant PLC system with touch screen HMI
GSM Modem (for data transmission from Pumping station to Main SCADA System)
PSTN Modem (for data transmission from Pumping station to Main SCADA System)
Instrumentation & Communication Cable as per Site Requirement
Broadband Lines from broadband service providers for communication.
VSAT at Individual Pumpi
Supply, retrofitting, testing and commissioning of Reflux (Non-Return) valve of 900mm size PN 1.0 generally conforming to IS-5312 or equivalent international standard with latest amendments. Material of construction: - Body, cover, door, hinge: Ductile Iron Hinge pin: SS 304/ SS 316 Body ring, disc face: SS 410 Surface Protection: Electro static epoxy powder coating. The job includes complete replacement of 100mm By-pass arrangement for NRV. Make: VAG/ IVC/ KIRLOSKAR/ TALIS/ AVK/ GM/equivalent make
"Control Valves: Supply, retrofitting, testing and commissioning of Sluice valve (SCADA compatible) of 600mm size, PN 1.0 conforming to IS 14846 or equivalent international standard of following specification: -" Material of construction: - Body, Bonnet, Wedge: S.G Iron as per IS 1865 Spindle/Stem: Stainless Steel as per IS 6603 Stem nut, seat ring: High tensile brass The job also includes providing and fitting of rubber gaskets for end connections. Make: VAG/ IVC/ KIRLOSKAR/ TALIS/ AVK/GM/equivalent make
Pumping Unit (Brounth Kul): Design, manufacture, supply, installation, testing and commissioning of standby pumping unit (Brounth Kul) along with all allied electro-mechanical equipments viz stabliser, FASD starter panel, 3-core copper cable from motor to starter of required size etc. As per specifications mentioned in Annexure A part II of II
"Incomer panel Supply, retrofitting, testing and commissioning of 2000A, 4-Pole ACB (Electrical Draw-out Type) with Microprocessor release having breaking capacity Icu of 50 kA at 415V along with complete control wiring for O/L, S/C, instantaneous, E/F protection release. The job also includes fitting of necessary devices for SCADA (Supervisary Control and Data Acquisition) compatibility."
GSM Communication for Individual Pumping Station
"Starter: Supply, installation, testing & commissioning of 415 V Fully automatic Microprocessor based 375 H.P soft starter with built in bypass arrangement for pump control application as per specifications mentioned in Annexure "D".
B. 40 mm aggregate avg. lead of 7 km
Non redundant UPS System for each Pumping Station
4 Nos. level switches for each Pumping Station.
CCTV 08 Ch NVR system with 5MP camera with 01 no. PTZ-10X and 07 no. IP cameras at each pump station with communication to Central SCADA.
Transducers for motors/ RTDs
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :
Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil :
Extra for every additional lift (2nd lift) of 1.5 m or part thereof in excavation/banking excavated or stacked material, All kinds of soil
Extra over item no 124.02 owards allowance for form-work
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil :(1 meter from cutting edge)
Extra for earth work in excavation in or under water/liquid mud incl.pumping out water as required (2m below water level @40%)
Extra for earth work in excavation in or under water/liquid mud incl.pumping out water as required (1m below water level @20%)
Carriage of materials by H/L for an average lead of 50M Stone Soling
Supplying and stacking at site. Good Earth
Filling empty cement bags with sand/ earth; including cost of sewing and strings; excluding cost of bags and earth / sand
Placing of earth filled EC bags In Dry
Add cost of EC bags .
Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared.
Carriage of materials by H/L for an average lead of 100M 20mm agg/sand
Silt clearance from canals. Inclusive of initial lead and lift ( 50m & 1.5m respectively ) Dry
Banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m in All kinds of soil:
Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered). Depth exceeding 1.5 m but not exceeding 3 m
Complete Job
Removal of unhygienic materials (so classified by the site engineer) from designated sites and its disposal as per directions, all inclusive.
Open timbering in trenches including strutting and shoring complete (measurements to be taken of the face area timbered): Depth exceeding 1.5 m but not exceeding 3 m
Open timbering in trenches including strutting and shoring complete (measurements to be taken of the face area timbered): Depth exceeding 3 m but not exceeding 4.50 m
Extra over Item no, 124.01 towards allowance for form-work
Hand-packing stones in wire-crates; excluding cost of crates and stones
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharg. Made of G.I. wire of dia 4 mm
Binding wire for binding crates
Extra for laying concrete in or underwater and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete Note for item No.:- The quantity will be calculated by multiplying the depth measured from the sub-soil water level up to centre of gravity of concrete under subsoil water level with quantity of concrete in cum executed under sub-soil water. The depth of centre of gravity shall be reckoned correct to 0.1m, 0.05m or more shall be taken as 0.1m and less than 0.05m ignored.
Providing and Dumping of dry stone soling .
Dumping stone excluding cost of stones. in Horizontal on level
On Slopes (Behind pitching)
Supply of stones
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Grouting of stone pitching using M-10 nominal mix concrete (max. size of aggregates; 20mm nominal) @ 3.65 cum per 100 sq m on horizontal/side slopes; complete including curing
Carriage of materials by means of mechanical transport from source upto actual site of work including loading, unloading and stacking of materials at site. A. Stone avg. lead of 13km
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
Actuators for following size Cast Iron Double Flanged Valves in Existing Pumping Stations. The Scope includes supply of gearbox assembly for operating through actuators: Actuator for 600mm
Central non redundant SCADA system including hardware, server, Engineering Station, Operator Station & Monitoring Screen as per technical specifications mentioned in Annexure E part I
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Ultrasonic insertion type Flowmeters: >=900mm
Ultrasonic insertion type Flowmeters: 600mm
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and laying in-situ concrete lining using M-10 nominal mix concrete (max. size of aggregates: 20mm nominal). In beds
In side slopes, - upto a height of 3.5 m above bed
Providing and laying in-situ concrete lining using M-20 nominal mix concrete (max. size of aggregates: 20mm nominal). In beds
Carriage of materials by H/L for an average lead of 50M Stone Soling
In side slopes, - upto a height of 3.5 m above bed
Curing canal lining for 28 days. In beds
In side slopes.
Providing and laying cement concrete in kerbs, steps and the like at or near ground level including curing, excluding the cost of centring, shuttering, and finishing. 1:1½:3(1 cement :1½ coarse sand :3 graded stone aggregate 20 mmnominal size)
12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Columns, pillars, piers, abutments, posts and struts.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Installation charges of complete SCADA system for Lift Irrigation Scheme including 04 No. pumping stations.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc complete On steel work
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Aircon for Scada control room as per technical specifications mentioned in Annexure E part II
Providing and fixing in position of MS J Bolts 20 mm dia of 1 m length including cost of nuts and washer.
Lubricating, oiling, greasing of two no. of gates including repairs to shutter by way of removing dents, Kinks and setting of iron gates, repairs to site channels by way of removal of bands and kings including setting and fixing complete, providing and fixing of rubber seal for shutters and painting of gates complete job.
Providing and placing in position of 100 mm Dia PVC type C) heavy duty pipe for weep holes to be provided in the Abutment and wing walls.
Provoiding and supplying of auto levels of well reputed brand including all accossories required for the execution of project.(complete job)
Hire Charges including operational charges for Total Station required during execution of work till its completion, Complete Job .
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in charge. 1:3:6 or richer mix (i/c equivalent design mix)
supplying , hoisting and fixing in position single winch machine with lifting screws having double square threads capable of lifting the load of gate.Winch machine shall consist of mill cut worm and gear arrangement incl. handle and locking accessories. The machine shall be of approved brand and make Bosch. The work includes all sorts of carriages upto site of work incl. cost of one coat of primer and two coats of paint, cost G.I or MS caseing pipes for caseing of lifting screw with lid and cost of greasing, oiling,testing and commissioning (complte job)
Providing and fixingof rubber seal to gate for checking of leekages PVC -Ist ,Ist -quality
Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete 450 mm dia. R.C.C. pipe
Engagement of unskilled labour for removing of dead stock/debris from rooms ,including cleaning etc
Providing and fixing of PVC (super heavy with round moulding) tonugue and -groove , rib reinforced wall and ceiling pannells with nailing fins of 100% virgin , exterior grade PVC of min thickness 12.7 mm panelling lining on wall including cost of nails ,screws etc all carriage upto the site.complete job.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size of tile 500x500 mm
Providing and fixing wallpaper of standard quality design pattern & shade approx 53-56 sft per roll( of heavy duty,100%opacity ,completely covers whatever is under neath ,textured finsh, great image clarity and colour properly and of manimum thickness of 0.25mmincluding necessary adhesives/wastage/carriage complete job as directed by engineer incharge
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work
Finishing walls with Acrylic smooth exterior paint of required shade: Old work (one or more coats applied @ 0.90 liters/ 10sqm)
Providing and fixing of lighting points, 1 lighting point should include wiring for lighting points in 1.5 square mm PVC installed copper wire of approved brand (Havells, Anchor, Finolex) and 2.5 Square mm PVC installed multi standard copper wire for lighting sub mains 6 AMP one way modular switch of approved brand 2mm thick PVC Conduit / Channels with bends and junciton boxes etc 6AMP. Spol DB for housing MCB and Hylam sheets with wooden boxes recessed involved with all accessories of approved brand i.e 15 watts lED Light, also shall include inverter wiring complete Job.
Providing and fixing of heating points, 1 heating poing should include wiring for heating points in 4 square mm PVC installed copper wire and 4 Square mm PVC installed multi standard copper wire of approved brand (Havells, Anchor, FiNolex) for heating sub mains 16 AMP one way modular switch of approved brand (Havells, GM, Anchor) 2mm thick PVC Conduate/Channels with bends and junciton boxes etc 6AMP. Spol DB for housing MCB and Hylam sheets with wooden boxes recessed involved with all accessories of approved brand complete Job.
Providing and fixing of fan point including the fan (Ceiling / Exhaust) One Fan point shall include wiring for fan points in 1.5 Sqmm PVC insulated multi strand copper wire of approved brand 1200mm ceiling fan / 225mm exhaust fan of approved brand (Havells, Orient, Bajaj) with ceiling roses and PVC square block, 350 watts junction boxes etc, fan control switch, 6 AMP Spol MCB, 10 AMP DB MCB, 2 way DB for housing MCB for lighting circuits and hylam sheets with wooden boxes recessed involves with accessories of approved brand, complete job
Providing and fixing of water heater of capacity 25 lt of reputed make; all complete including fittings, as per the direction of engineer incharge.
Carriage of materials by H/L for an average lead of 100M 20mm agg/sand
Complete Servicing of 1.6 MVA H.T transformer of Stage 4th by way of:
Supplying and placing in position the steel almirah medium size made up of steel with lock arrangement, shelving, doors, of approved brand as specified and directed by engineer in charge. (H 198 X W 87 X D 48) Cm
Providing of high back revolving officer chair with head rest centre tilt with single lock including S- Shaped lumber support. Back rest and sitting material of Vegan Leather with Aluminium arms.
Providing of non revolving officer chair sitting material of Vegan Leather with Aluminium arms
Providing of walnut finished Office wooden table with side tables
Repairs and renovation of water closet / bathroom for Zildari office (Complete job) LS
A. Stone avg. lead of 12km
A. Stone/boulder avg. lead of 11 km
A. Stone avg. lead of 10 km
A. Stone avg. lead of 7 km
A. Stone avg. lead of 6 km
A. Stone avg. lead of 3 km
B.40 mm aggregate avg. lead of 13 km
B.40 mm aggregate avg. lead of 12 km
B.40 mm aggregate avg. lead of 10 km
B.40 mm aggregate avg. lead of 7 km
B. 40 mm aggregate avg. lead of 5 km
B. 40 mm aggregate avg. lead of 2 km
C. 20mm ggregate avg. lead of 13 km
C. 20mm ggregate avg. lead of 12 km
C. 20 mm aggregate avg. lead 10 km
C. 20 mm aggregate avg. lead of 7 km
C. 20 mm aggregate avg. lead of 6 km
C. 20 mm aggregate avg. lead of 5 km
C. 20 mm aggregate avg. lead of 2km
D. Sand avg. lead of 12 km
D. Sand avg. lead of 10 km
D. Sand avg. lead of 9k
D. Sand avg. lead of 8km
D. Sand avg. lead of 5 km
D. Sand avg. lead of 4 km
Carriage of materials by H/L for an average lead of 200M Stone
B. Dumping stone including cost of stones in Horizontal on level
D. Sand avg. lead of 3 km
E. Cement /Steel avg. lead of 2 km.
E.Cement/steel avg.lead of 5km
E.Cement/steel avg.lead of 8 km
100 mm2 ACSR Conductor
F. earth for 10 Kms lead
F. earth for 8 Kms lead
Aggregates 40mm
PG Clamps for 100 mm2 ACSR Conductor
D. Sand avg. lead of 3 km
E. Cement /Steel avg. lead of 2 km.
Aggregates 20mm + Sand
Cement
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.75 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.96 MB
BOQ_957060.xls
BOQ • 0.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .