Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 CrAccepted-AOC | ₹46.5 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹53.5 CrRejected-AOC | ₹53.5 Cr | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not-Qualified |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not-Qualified |
| 5 | Rejected-Technical PLOT NO 110 2 CRYSTAL BUILDING SHARE PUNJAB COLONY ANDHERI EAST MUMBAI 400093 | - | - | Rejected-Technical Not-Qualified |
Tender Value
₹49.5 Cr
EMD Value
₹98.9 L
Closing Date
23 Dec 2021, 2:00 pmClosed
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Construction of Multi-Storied Assam Bhawan Complex including Convention Centre at Bangalore, Karnataka (Balance work)
2021_PWBNH_23574_1
SMC/75/2021/3 Dated Guwahati the 23th Nov. 2021
Open Tender
Civil Works - Building
545 days
Bangalore
Please refer Tender documents.
6 documents required · 6 mandatory
₹12,500
Assam State Road Board Maintenance (Road) Fund
₹98.9 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
24 Jun 2022
4 Dec 2021
23 Dec 2021
4 Dec 2021
23 Dec 2021
4 Dec 2021
14 Dec 2021
Amount
Clearing of wild vegetation growth, unwanted grass, etc removal and disposal of the rubbish to a suitable municipal dumping area including all lead and lift etc complete all as per direction of Engineer in charge. Payment for clearing will not be made for area covered under excavation of soil i.e. under item no. 1.3.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil (From 1.5 to 3 m depth)
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil (From 3 to 4.5 m depth)
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil (From 4.5 to 6 m depth)
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil (From 6 to 7.5 m depth)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Cartage of good earth for raising low site all around with approved soil obtained from outside by truck carriage including loading,unloading and stacking at Site,breaking clods, dressing etc. complete including paying necessary forest royalty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. complete as directed and specified.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : "1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size drived from natural sources).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : "1:4:8 (1 cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size drived from natural sources).
Providing and laying in position ready mixed or site batched design mix concrete for plain cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Note : (1) Excess/less cement used than specified in this item is payable/ recoverable separately. (2) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacement of OPC as per IS : 456. Uniform blending with cement is to be ensured in accordance with clauses 5.2 and 5.2.1 of IS: 456 -2000 in the items of BMC and RMC." All works upto plinth level : Concrete of M10 grade with minimum cement content of 220 kg/cum
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. Upto and including 12mm dia.
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). 12 mm average thickness.
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). 25 mm average thickness in 2 layers.
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). 50 mm average thickness in 3 layers.
Providing & Grouting of dowel tubes / Shear keys / Joints of precast members with M-60 grade cementitious grout (Non Shrink) of approved make by suitable means ( Free flowing / pump),curing etc. Complete as per directions of Engineer-incharge. (The payment shall be made on the basis of actual weight of approved grout injected.) Stirrer mixed cementitious grout (non shrink) of approved make in dowel tubes / Shear keys / Joints of precast members.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. without disturbing the other structural elements. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. without disturbing the other structural elements such as column, beams & slab.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Applying Rust remover & Passivator: Cleaning of einforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. Bars upto 12 mm diameter
Applying Rust remover & Passivator: Cleaning of einforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. Bars above 12 mm diameter
Providing the formwork including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts .
Grouting Nipples: Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Shelves (Cast in situ)
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Stairs, (excluding landings) except spiral-staircases
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Edges of slabs and breaks in floors and walls. Under 20cms wide
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Weather shade, chajjas, corbels etc. Including edges.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level- Concrete of M30 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level- Concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level- Concrete of M30 grade with minimum cement content of 350 kg/cum
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063). Floor Joint of 100 mm gap
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). Wall Joint of 100 mm gap
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). Roof Joint of 100 mm gap
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand).
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means. 5TH Floor- 8th Floor
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade - Area of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade - Area of Slab over 0.50sqm
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick.
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-incharge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing approved make Brass Pull Handle 300 mm size fixed with necessary screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved make bright finished brass 100mm Mortice latch and lock with 6 levers and a pair of lever handles with key cylinder(with keys in triplicate) fixed with necessary screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved make bright finished brass Tower bolt 250x10mm dia fixed with necessary screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete..
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per nufacture's specification and direction of engineer in charge all complete. 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces
Supplying and fixing rolling shutters of approved make and of required size, made of 80x1.25 mm M.S. laths with 1.25 mm thick MS top cover, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 complete all as required and as directed.++
Providing and fixing required size ball bearing for rolling shutters.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required, the fencing shall be supported with 65x65x8mm MS angle at 1.2m C/C embeded in ground in cement concrete 1:2:4 of size 300mmx300mmx600mm deep etc complete as per the direction of Engineer-in-charge
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slabs
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre .
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size -Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size -Size of Tile 800 x 800 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size- Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size- Size of Tile 800 x 800 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 800 x 800 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
12 mm cement plaster of mix : 1:6 (1 cement : 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 fine sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. - 10 to 13 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. - 13 to 16 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. - 16 to 19 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. - 19 to 22 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. - 22 to 25 m
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.
Providing and applying two or more coats of approved Premium Acrylic Smooth exterior paint with Silicone additives (of approved make and shade) over a base coat of Exterior primer of approved manufacture, as per manufacturer's specifications on external walls, chajja, parapets surfaces etc.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats.
Providing & fixing 150mm wide Chicken wire mesh on joints of RCC & Brick work before plastering complete in the direction of Engineer-in-charge.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls,reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm.
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) Epoxy injection grout in concrete/RCC work of approved make
Providing and placing in position suitable PVC water stops conforming to IS:12200 between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc complete. Serrated with central bulb (225mm wide,8-11mm thick)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around . (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Grading roof for water proofing treatment with : Cement mortar 1:4 (1cement : 4 coarse sand)
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75 x75 mm deep chase
Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, allcomplete as per direction of Engineer-in-Charge.
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS :1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portion Powder coated aluminum (minimum thickness of powder coating 50 micron)
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminum (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
Filling the gap in between aluminum frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks)
Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main "T" at 600mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum),including factory painted after bending and perforation,and backed with a black Glass fiber acoustical fleece.
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long Dry Wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/ mK.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000mm length and L-hape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be prepainted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre Antimicrobial false ceiling tile confirming to ISO 5 (class 100 ) specifications
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.. Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, ptimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineerin- charge.
Providing and laying 125 micron thick Membrane of impermeable plastic sheeting
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine
Painting runway/taxi track/apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete . New work (Two or more coats)
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line , level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except sharp curve shall not be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by engineer-in-charge).
Providing and filling in position bitumen mix filler of proportion 80 kg. of hot bitumen, 1 kg. of cement and 0.25 cubic metre of coarse sand for expansion joints.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20 mm
Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm
Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm
Fine dressing of the ground
Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge..
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 60 cm dia, and 60 cm deep.
Providing and stacking of Aspidistra, having 10 to 15 leaves well developed with fresh & healthy in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Cuphea chinensis of ht. 20-30 cm full of branches and healthy foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Ophiopogon, Green/Black full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge.
Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of plant Canna dwarf of height 25 to 30 cm., 2 to 3 suckers in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
Providing and displaying of Philodendron selloum having ht. 45 cm to 60 cm with 12 to 16 leaves, well developed, fresh and healthy foliage in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and displaying of Dracaena Kedarnath having ht. 30 cm & above, well developed with good colorful foliage in 20 cm size of Earthen pot/ Plastic pot. & as per direction of the officer-in-charge.
Providing and Displaying Bamboo Buddha vally variety with umbrella shape having 120 to 135 ht. with fresh & healthy foliage well developed in 40 cm Cement pot multy branch, bushy as per direction of the officer-in-charge.
Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Cycus revoluta in 35 cm challi, specimen , having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed as per direction of the officer-in-charge.
Providing and Displaying Ficus Retusa topiary well developed with fresh & healthy 5 to 6 big ball specific size and shape 180 to 210cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Furcaria Variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Zamia palm well developed with fresh & healthy leaves 90 cm ht in 35 cm cement pot as per direction of the officer-in-charge.
Providing and Displaying Travelers palm well developed with fresh & healthy foliage 120 to 150 cm ht. in 35 cm Cement Pot as per direction of the officer-in-charge.
Providing and displaying of Areca palm having ht. 1.50 m to 1.80 m with 6 to 8 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and stacking of Alstonia scholaris plant of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Bombax ceiba of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Bottle palm of ht. 210-240 cm bottom girth 30-35 cm well developed in big HDPE bags.
Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Chukrassia tabularis of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Erythrina indica of height 150-165 cm. in big polybag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Ficus benjamina (green) of height 120-135 cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Ficus Iyrata of height 45-60 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Foxtail palm of ht. 120-150 cm bottom girth 15- 20 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Magnolia grandiflora of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.v
Providing and stacking of Milletia ovalifolia of height 120-135 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge.
Providing and stacking of Plumeria alba of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge.
Providing and stacking of Spathodea campanulata of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Tecoma argentea of height 120-135 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing of Schefflera Green plant (three in one), mounted on moss stick 90 cm, well developed with full of fresh & healthy leaves from bottom to top with rich foliage in 25 cm size of Earthen pot/Plastic pot .& as per direction of the officer-in-charge. .
Providing and stacking of Ficus panda of height 30-45 cm. with 3-4 branches and healthy foliage in p.bag of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Ficus long Island of height 15 cm to 20 cm, full of branches and foliage in 20 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Thuja compacta of height 45-60 cm., well branched in earthen pots of size 25 cm as per direction of the officer-in-charge.
Providing and supplying the one component, Polymer modifed, cementitious anti-corrosive primer, formulated to provide dual protection of a polymeric barrier and an integral corrosion-inhibiting system, to the existing steel and additional steel provided before pathcing of damaged areas, using suitable tools and equipment inclusive of Material, Manpower and Equipment. (R. A. Attached)
Providing and Applying two coats of Advanced Organo Functional Corrosion Inhibitor with proven track record, and excellent depth of penetration reacting with the concrete substrate to form a permanent chemical bond on the prepared concrete surface using brush at a consumption rate of maximum 600ml per sq.m. inclusive of Manpower, Material and Equipment. (R. A. Attached)
Providing and Pouring into the fixed leak proof formwork to repair the damaged concrete portion with high flow, single component, duel shrinkage-compensated, cementitious microconcrete that acheives a compressive strength minimum of 25 MPa at 3 day and 40 MPa at 28 days. before the bonding agent becomes tack free, inclusive of Manpower, material and Equipment. (R. A. Attached)
Providing and Repairing the damaged concrete portion with single component, fibre reinforced, duel shrinkage-compensated, thixotropic, cementitious patch repair mortar that acheives compressive strength of 35 MPa at 7 day and 45 MPa at 28 days and capable of applying 25 to 30 mm avg. thick in single layer initially by hand and finishing with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface with an average thickness of 40mm inclusive of Manpower, Material and Equipment. (R. A. Attached)
Providing and Fixng Shear connectors of 8mm dia. HYSD steel with two component, styrene & cement free, epoxy-acrylate fixing and anchoring compound supplied in self mixing Cylinder-in-cartridge form that avoids site mixing using standard sealant applicator gun after drilling holes of 12mm diameter to a minimum depth of 100mm at required locations, inclusive of all material, manpower and equipment. (R. A. Attached)
Providing and Applying a single coat of two component solvent less epoxy resin based bonding coat complying to ASTM C881 Type 2, Grade 2, and Class B &C having a open time of 6 hours and shall exceed the tensile strength of concrete in terms of its adhesive bond strength using brush or roller before the application of repairing material inclusive of material, manpower and equipment. (R. A. Attached)
Polymer Bond Coat: By using acrylic polymer, cement in 1:1 proportion or in recommended proportion as per manufacturer’s specification including cleaning the surface, wetting etc. before applying cement plaster wherever required. (R. A. Attached)
Providing and Applying Single Ply Unidirectional Glass fibre of 900GSM after necessary surface preparation including rounding off edges to a radius of 10mm, priming and satuartion of fibre as per the dry lay up process and sprinkling of sand after the final saturant application for giving protection screed on the top as per the procedure mentioned including of Material, Manpower and Equipment. (The cost of Protection Screed shall be paid in Plaster quantity). (R. A. Attached)
Providing shear anchor of 10mm dia and 150mm long of high strength hybrid woven fiber glass fabric mesh with filling of hole with KRISHNA EPOXY or other equivalent & approved of SIKA/ BASF, removing/drawing out of the entrapped air etc. from the drilled hole all complete as per manufacturer’s specifications and directions of the Engineer in Charge. It shall include labour for mixing EPOXY resin, saturating the anchor with EPOXY, drilling the RCC members and inserting the saturated anchor inside the drilled hole and merging the bushes with the RCC members. (R. A. Attached)
Providing and Fixng standard injection packers of 10mm diameter after drilling holes of required diameter along the crack, sealing the packer with epoxy putty, removal of packer after grouting inclusive of all Material, manpower and equipment (R. A. Attached).
Providing and Injecting the fixed packer two-component low viscosity (<350 cps) epoxy resin system that acheives compressive strength in excess of 55 MPa at 1 day & 65 MPa at 7 days. and shall exceed 15 MPa in slant shear bond strength with minimum pot life of 30 minutes at ambient temperatures complying with ASTM C881, Type 1 & 4, Grade 1, Class B &C using any of the standard pressure grouting methods at a maximum pressure of 2kgs/sq.cm. till refusal and allowing the epoxy grout to cure before removal of packers inclusive of cost of Material, Manpower and Equipment. (R. A. Attached)
Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture Stainless Steel 304 grade CYLINDRICAL LOCKS - CLASSIC LOCK. Complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 300 mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Toilet Cubical Providing and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panels Finish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard. This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 316) as per manufacturer's specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs.
Providing and fixing approved brand and manufacture SS 304 grade Top & Bottom Patch fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade H type 900mm Pull Handle with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Glass to Glass Lock Round type with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Floor spring (weight approx 100-120kgs) fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge
Opaque Roller Shades : Providing & fixing of Blackout Roller Blinds fabric made up of 100% Polyester with Acrylic coated of 0.32mm(PVC free) of thickness 0.50mm ±5% and wieghing 270-295gsm with openess factor of 0% .Shrinkage % Warp<0.5 & Weft <0.5,Color fastness>5-6. The control clutch drive unit engineered heavy duty chain drive pulley operating system consisting of gear clutch housing and locking plug containing minimum 6 ribs and inserted at minimum of 37mm into roller tube. It is self-lubricating Exclusive clutch with safety pins for secure bracket installation and unlocking pin for quick manual removal. Universal clutch is most convenient for large windows down to the smallest windows. It shall be driven by a ball chain pulley with ball chain and can be positioned at Right hand or Left hand side of the shade. Clutch gear ration 1.75:1 for reduced operating force on larger blinds. Tube bearing plug idler Exclusive self-lubricating spring loaded plastic bearing end plug with positive locking wheel allows for adjustment and provides for a secure installation and removal of shade. Tube bearing plug contain minimum 6 ribs and inserted a minimum of 37mm into roller tube. Mounting hardware brackets universal brackets including end plug bracket with lock down retainer device. Brackets finish of powder coated metal installation brackets made of stamped and hardened steel with 46mm projection for wall, ceiling and side fitting with screws and end cap covers. Roller tube circular-shaped aluminum tube extruded from alloy 6060 and temper T66 – EN755 of 37mm inside diameter and outside diameter 40.2mm extruded tube to have a 1.6mm wall thickness with standard anodized natural finish. Heavily reinforced with minimum six internal ribs providing additional tensile strength and allows for secure placements of clutch and end plug. Bottom rail flat-shaped extruded aluminum from alloy 6060 and temper T66 – EN755 of dimension 13mm * 30mm and wall thickness of 1.5mm and weight of 390g/m. Rail standard finish of powder coat white color and provided cover. Ball chain shall be 2mm diameter cord with 4.5mm diameter acetal balls molded coaxially to it on 11.8mm pitch to form an endless ball chain. It is used for raising or lowering action of the shades. Plastic parts all plastic components are UV-stable compounds available white colour.
Designing, providing, installing/fixing skylight consisting of 16mm thick multiwall polycarbonate sheet "Danpalon" or equivalant in approved color (minimum 900mm wide) with standing seam on both sides & double tooth snap on locking system to ensure maximum uplift capability. The panel shall be co-extruded UV protected and antiglare/softlight to prevent glare/sun streak . The cross section of one cell should not be more than 4mmX4mm & weight of single panel shall not be less than 3250gm per square metre. The system shall be fitted on purlins with spacing as specified by manufacturer with stainless steel fastener & screws and supported on MS tube framework, complete as per specification, drawing and direction of Engineer in Charge. The rate includes cost of all the operations,labour materials and tests (as applicable) for proper completion of the work except the M.S tubular framework which shall be measured and paid separately (For payment purpose the area of finished polycorbonate sheet fixed in position shall only be measured).
Providing and fixing 18mm thick Granite stone work for wall lining upto 10 m height in cement mortar 1:3 (1cement : 3 coarse sand) including pointing with white cement mortor with an admixture of pigment to match the granite shade complete as per direction of Engineer-in-charge.
Extra for pre finished nosing to treads of steps of Granite stone.
Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre .
Providing and fixing 40mm thick cladding comprising of Wooden framwork using 25mx50mm sections at a maximum spacing of 600mm in any one direction (including adding members as required) covered with12mm thick BWP ply layered with 1 mm thk Laminate(Basic Rate Rs.25/-sqft)on one side pasted and pressed with adhesive to give a uniform and smooth finish, including top mouldings / margins, melamine polish etc. to finish the thickness, as shown complete in drawing. All members / ply etc. shall be treated with anti-termite solution as per norms. No extra shall be paid for making of openings, door / window frames and for making provisions for electric conduits.
Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge.
Providing and fixing 50 micron thick Etching strips (film) over glass Non-fade, self adhesive,easy to cut and trim to size and easy to install, of approved make and manufacturer, fixed as per manufacturer's specifications and as specified in Arch. drawing, all complete in all respects as per direction of the Engineer-in-charge.
Providing & fixing access panel is made out of Moist Bloc (Moisture Resistant) board for opening 600 x 600mm of thickness 12.5mm. All edges of the panel are reinforced with aluminium profiles and corners are guarded with stainless steel 304 grade clips to increase strength and prevent damages. complete in all respect as directed by Engineer-in-charge.
Providing construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine complete as per direction of engineer-in-charge.
Providing and stacking of Colocasia esculenta in 25 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.
Providing and displaying of Canna indica , well developed in 25 cm size Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and displaying of Alocasia macrorrhiza , well developed in 25 cm size Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and stacking of Salix babylonica of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. - 75 mm diameter
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. - 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single Push Fit Coupler - 75 mm dia
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single Push Fit Coupler - 110 mm dia
Plain bend 87.5 deg - 75 mm dia
Plain bend 87.5 deg - 110 mm dia
Shoe (Plain) - 75 mm dia
Shoe (Plain) - 110 mm dia
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. - 75 mm dia
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. - 110 mm dia
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink of approved make as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink with drain board -510x1040 mm bowl depth 250 mm
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing & fixing heavy quality PVC waste pipe for sink including PVC waste fitting Complete . Flexible Pipe - 40mm Dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing & fixing toilet paper holder - C.P. brass
Providing and fixing soil waste and vent pipes. 100 mm dia. - Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing soil waste and vent pipes. 75 mm dia. - Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing M.S. holder-bat clamps of approved design to sand cast iron/ centrifugally cast iron(spun) pipes embedded in and including cement concrete blocks 10x 10 x 10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls, etc. For 100mm dia pipe
Providing and fixing M.S. holder-bat clamps of approved design to sand cast iron/ centrifugally cast iron(spun) pipes embedded in and including cement concrete blocks 10x 10 x 10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls, etc. For 75mm dia pipe
Providing and fixing bend of required degree with access door insertion rubber washer 3mm thick, bolts and nuts complete. 100 mm dia - Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing bend of required degree with access door insertion rubber washer 3mm thick, bolts and nuts complete. 75 mm dia - Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing plain bend of required degree: 100 mm dia - Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing plain bend of required degree: 75 mm dia - Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing double equal plain junction of required degree. 100 x 100 x 100 x 100mm - Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905.
Providing and fixing single equal plain junction of required degree. 100 x 100 x 100mm - Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing single equal plain junction of required degree. 75x75x75 mm - Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing single unequal plain junction of required degree : 100x100x75 mm- Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing terminal guard 100 mm - Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 100 mm - SS 304 grade coupling with EPDM rubber gasket
Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 75 mm - SS 304 grade coupling with EPDM rubber gasket
Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipe of diameter: 100mm
Providing and fixing trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent, arm complete, including cost of cutting and making good the walls and floors. 100mm inlet and 100mm outlet - Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. Total bracket length 580 mm of approved shape and design (for single 100 mm dia pipe)
Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. Total bracket length 810 mm of approved shape and design (for two 100 mm dia pipes)
Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. Total bracket length 1040 mm of approved shape and design (for three 100 mm dia pipes)
Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00m spacing and also including cutting of chases and making good the walls including testing of joints complete as per direction of Engineer -in-charge. (The pipe length inserted in the fitting shall not be measured for payment). Internal work - Concealed Pipe 15.88 mm outer dia .Pipes.
Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00m spacing and also including cutting of chases and making good the walls including testing of joints complete as per direction of Engineer -in-charge. (The pipe length inserted in the fitting shall not be measured for payment). Internal work - Concealed Pipe 22.22 mm Outer dia pipes
Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer-in-charge. (The pipe length inserted in the fitting shall not be measured for payment). Internal work - Exposed on Wall 28.58 mm outer dia Pipe
Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer-in-charge. (The pipe length inserted in the fitting shall not be measured for payment). Internal work - Exposed on Wall 34.00 mm outer dia Pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Coupling/Socket- For 15.88 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Coupling/Socket- For 22.22 mm Outer dia pipes
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Coupling/Socket- For 28.58 mm outer dia Pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Coupling/Socket- For 34.00 mm outer dia Pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducer - For 22.22 mm x 15.88 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducer - For 28.58 mm x 15.88 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducer - For 28.58 mm x 22.22 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducer - For 34.00 mm x 15.88 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducer - For 34.00 mm x 22.22 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducer - For 34.00 mm x 28.58 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Slip Coupling/ Socket - For 15.88 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Slip Coupling/ Socket - For 22.22 mm Outer dia pipes
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Slip Coupling/ Socket - For 28.58 mm outer dia Pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Slip Coupling/ Socket - For 34.00 mm outer dia Pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Elbow 90° - For 15.88 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Elbow 90° - For 22.22 mm Outer dia pipes
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Elbow 90° - For 28.58 mm outer dia Pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Elbow 90° - For 34.00 mm outer dia Pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducing Elbow 90° - For 22.22 mm x 15.88 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducing Elbow 90° - For 28.58 mm x 15.88 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducing Elbow 90° - For 28.58 mm x 22.22 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducing Elbow 90° - For 34.00 mm x 22.22 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducing Elbow 90° - For 34.00 mm x 28.58 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Equal Tee - For 15.88 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Equal Tee - For 22.22 mm Outer dia pipes
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Equal Tee - For 28.58 mm outer dia Pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Equal Tee - For 34.00 mm outer dia Pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducing Tee - For 22.22 mm x 15.88 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducing Tee - For 28.58 mm x 15.88 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducing Tee - For 28.58 mm x 22.22 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducing Tee - For 34.00 mm x 15.88 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducing Tee - For 34.00 mm x 22.22 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Reducing Tee - For 34.00 mm x 28.58 mm outer dia pipe
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Valve Connector - For 28.58 mm outer dia x 25 mm nominal dia threaded
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Valve Connector - For 34.00 mm outer dia x 32 mm nominal dia threaded
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 15 mm nominal bore
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 20 mm nominal bore
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 25 mm nominal bore
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 32 mm nominal bore
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 40 mm nominal bore
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 50 mm nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work (Domestic, Flushing & Irrigation Water supply) 25mm nominal nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work (Domestic, Flushing & Irrigation Water supply) 32mm nominal nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work (Domestic, Flushing & Irrigation Water supply) 65 mm nominal nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work (Domestic, Flushing & Irrigation Water supply) 80 mm nominal nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
With common burnt clay F.P.S (non modular) bricks of class designation 7.5
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S (non modular) bricks of class designation 7.5
Painting G.I. pipes and fittings with synthetic enamel paint (approved shade) with two coats over a ready mixed priming coat, both of approved quality for new work : 15mm diameter pipe
Painting G.I. pipes and fittings with synthetic enamel paint (approved shade) with two coats over a ready mixed priming coat, both of approved quality for new work : 20mm diameter pipe
Painting G.I. pipes and fittings with synthetic enamel paint (approved shade) with two coats over a ready mixed priming coat, both of approved quality for new work : 25mm diameter pipe
Painting G.I. pipes and fittings with synthetic enamel paint (approved shade) with two coats over a ready mixed priming coat, both of approved quality for new work : 32mm diameter pipe
Painting G.I. pipes and fittings with synthetic enamel paint (approved shade) with two coats over a ready mixed priming coat, both of approved quality for new work : 40mm diameter pipe
Painting G.I. pipes and fittings with synthetic enamel paint (approved shade) with two coats over a ready mixed priming coat, both of approved quality for new work : 50mm diameter pipe
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 25mm diameter pipe
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 32mm diameter pipe
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 40mm diameter pipe
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 50mm diameter pipe
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : Width of sand filling = 300mmnDepth of sand filling Under the pipe = 75mm+ Above the pipe = 150mm+ 25mm diameter pipe
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : Width of sand filling = 300mm Depth of sand filling Under the pipe = 75mm+ Above the pipe = 150mm+ 32mm diameter pipe
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : Width of sand filling = 300mm Depth of sand filling Under the pipe = 75mm+ Above the pipe = 150mm+ 40mm diameter pipe
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : Width of sand filling = 300mm Depth of sand filling Under the pipe = 75mm+ Above the pipe = 150mm+ 50 mm diameter pipe
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : - 15 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : - 20 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : - 25 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : - 32 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : - 40 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : - 50 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : - 65 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore (Basic rate of Long Bib Cock= Rs. 500/- each. Excluding GST)
Providing and fixing C.P. brass angle valve for basin mixture and geyser points of approved quality confirming to IS: 8931.
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 50 mm dia
Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 100 mm dia nominal bore
Providing and laying D.I. specials of class K-12 suitable for push-on jointing as per IS : 9523 : Up to 600 mm dia
Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and the cost of rubber gasket : 100 mm dia pipes
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 : 100 mm dia Ductile Iron Double Flanged
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 coarse sand 6 graded stone aggregate 20 mm nominal size) including disposal of malba.
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified 100 mm nominal bore - 65 mm dia.
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified 100 mm nominal bore - 80 mm dia.
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified 100 mm nominal bore - 100 mm dia.
Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. - 80 mm dia.
Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. - 100 mm dia.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 150 mm diameter HDPE pipe/ RCC pipe / S. W. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 250 mm diameter HDPE pipe/ RCC pipe / S. W. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 450 mm diameter HDPE pipe/ RCC pipe / S. W. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180 x 150mm size P-type - With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : - 150mm dia RCC pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : - 250mm dia RCC pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : - 450mm dia RCC pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : - 500mm dia RCC pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : - 600mm dia RCC pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : - 700mm dia RCC pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : - 900mm dia RCC pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes: -Size 90 x 80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately): With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality . HD - 20 Circular shape 560 mm internal diameter
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : - For pipes 100 to 250 mm diameter
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : - For pipes 350 to 450 mm diameter
Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposing of surplus excavated soil as directed, within lead of 50m. All kinds of soil Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: Ordinary rock Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: Hard rock (requiring blasting) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. Ordinary Rock
Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. Hard Rock(requiring blasting)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : "1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil - 400 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 200 mm nominal size dia.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap/shoe or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. : 200 mm clamp.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). : 200 mm dia
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified. : 80 mm dia.
Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. : 80 mm dia.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including geting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by Engineer-in-Charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, helves,chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing & reinforcement with1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)
Centring and shuttering including stutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and acees platform
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of Grade Fe-500D or More.
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12mm dia steel bar conforming to IS :1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and heaving manufactures permanent identification mark to be visible even after fixing " including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6: (1 cement :3 coarse sand :6 graded stone aggregate 20mm nominal size )complete as per design.
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. HD-20 circular shape 560 mm internal diameter.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil - 400 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 200 mm nominal size dia.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia.
Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer –in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. : 200 mm Clamp.
Providing and fixing approved make hand shower (Health faucet) of 1.2mtr long with 8mm dia Easy Flex Tube with wall hook and flow restrictor with flow rate 6 litre per minute at 3 bar in chrome finish and wall hook.
Providing and fixing of fully automatic "NO TOUCH" durable & shock proof hand drier of approved make & manufacture suitable to operate on 220 volts, single phase 50 hz, A.C. power supply, 1500 Watt and directly plugged to power point complete in ABS plastic body having drying time 20-30 seconds complete as per direction of Engineer in Charge. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. ( MAKE JAQUAR MODEL NO.- HDR-SAP-M99ACS or EQUIVALENT.)
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing complete as required. (MAKE-ModiGuard Sparkle Mirror )
Supply, installation, testing and commissioning built with 50 LPH Drinking Water R.O. unit with micron filtration pre-treatment unit, skid mounted R.O. module with pressure pump and pressure tank, drinking water cooler (High quality SS Tank for Storage 80 lts) , complete in all respects. ( Make & Model No. Eureka Forbes Pure Chill RO Storage Cooler cum Purifier or Equivalent)
Providing, laying, Jointing, Testing and commissioning of UPVC pressure pipes of 10Kg/Sqcm pressure rating class 5 (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead upto 50m complete, compaction and consolidation Including laying cement concrete 1:2:4 alround UPVC pipe including bed concrete and thrust blocks at bends as per standard design (For garden hydrants). - 40 OD mm
Providing, laying, Jointing, Testing and commissioning of UPVC pressure pipes of 10Kg/Sqcm pressure rating class 5 (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead upto 50m complete, compaction and consolidation Including laying cement concrete 1:2:4 alround UPVC pipe including bed concrete and thrust blocks at bends as per standard design (For garden hydrants). - 50 OD mm
Providing, laying, Jointing, Testing and commissioning of UPVC pressure pipes of 10Kg/Sqcm pressure rating class 5 (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead upto 50m complete, compaction and consolidation Including laying cement concrete 1:2:4 alround UPVC pipe including bed concrete and thrust blocks at bends as per standard design (For garden hydrants). - 63 OD mm
Providing & fixing Nickel Chromium Plated liquid soap dispenser with metallic bottle of approved brand & make 112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge.
Providing, Fixing of CP brass Towel Ring with CP brass wall brackets and providing & fixing CP brass screws complete as required.
Providing, Fixing of CP brass Towel Rail 600mm long without hanger with 3 hooks and CP brass screws complete as required.
Providing & fixing soap dish holder of approved design.
Providing and fixing CP brass single lever low flow wall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required.
Providing and fixing of approved make following- a) Concelaed type CP Brass diverter(for hot and cold water), overhead shower with arm with rubit cleaning system with flow rate 6 litre per minute at 3 bar complete with all accessories as required and spout with flow rate 3.8 litre per minute at 3 bar, wall flange complete with all accessories as required and making good the walls wherever required.
Providing,Fixing wall mounted of approved make Double Coat hook on door complete.
Providing and fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar.
Providibng and fixing straight type approved make single body push fit type WC pan connector with factory supplied spring loaded seal guard of approved make with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector.
Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe.
Providing and fixing cast brass Floor cleanout plug with suitable insert keys for opening in brass cap, male threaded joint/reducer with G.I. socket caulked to Pipe/fittings of CI pipe including cost of lead joints etc. complete in all respect. - 100 mm dia
Providing and fixing GI inlet fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes and sockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete as directed by Engineer-incharge.
Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge. Circular Type - 125 mm nominal dia with 25 mm waste hole
Providing, Installing & fixing storage type water heater of approved make (vertical/horizontal type ) with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. Capacity15 litres (Basic rate = Rs.7290 /- each. Excluding GST)
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 65 mm diameter pipe
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 80 mm diameter pipe
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work. - 65 mm diameter pipe
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work. - 80 mm diameter pipe
Providing & fixing CI `Y' Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. - 65mm nominal bore
Providing & fixing CI `Y' Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. - 80mm nominal bore
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 25mm dia pipe, 600mm long with size of 250x250x6 mm MS plate
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 32mm dia pipe, 600mm long with size of 250x250x6 mm MS plate
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 40mm dia pipe, 600mm long with size of 300x300x6 mm MS plate
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 50mm dia pipe, 600mm long with size of 350x350x6 mm MS plate
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 65mm dia pipe, 600mm long with size of 350x350x6 mm MS plate
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 80mm dia pipe, 600mm long with size of 400x400x6 mm MS plate
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 100mm dia pipe, 600mm long with size of 400x400x6 mm MS plate
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 150mm dia pipe, 600mm long with size of 450x450x6 mm MS plate
AIR TO WATER HEAT PUMPS FOR GENERATING HOT WATER Supply, installion, testing and commissioning of Hot Water Generation Plant with Packaged type Air to Water Heat Pump. These units shall be completely factory assembled including 2 Nos. Scroll Hermatically Sealed Scroll Compressor(s), evaporator, Condenser and Microprocessor Control Panel etc with R410 Referigerant and COP between 3-4. The Heat Pump shall have inbuilt hot water heat exchanger, pumps, valves. expansion valve, integrated CIP system and other accessories.The Heat Pump should be capable of producing hot water at minimum 60°C temperaure at outlet (condenser circuit) temperatures at 10°C ∆T. The Machine should have an operating ambient temperature range of 5°C to 40°C. Location: Terrace Level a. Built in electric panel as per safety norms as manufacturer standard. b. All other mountings, fittings & controls with all accessories and safeties c. All other mounting, fittings and controls. d. Suitable for electric supply of 415 + 10% volts & 50 Hz. e. All interconnecting wiring / cabling between heat pump and electrical panel. f. The Heat pump shall have an in-built facility to start / stop depending on variation in demand at different periods. g. System shall be complete with SS 304 Tank of 2 Hrs Storage Capacity, Primary and Seconary Circualtion pumps, Heat Exchangers, Return Recirculation Pump, interconnecting piping, valves and all accessories as required. h. System shall have 20% of total capacity in electrical heating as standby. i. System shall have an integrated Solar Heating system with 20% of total capacity for energy saving including Flat Plate Solar Panels, Mixing Tanks, Recirculation Pumps, etc Heating capacity : Approx. 30 KW (1 working + 1 standby) Hot Water Storage Tank : 1000 Ltrs System as Described Above
Reverse Osmosis Plant (RO) (400 LPH)- suitable for 5hrs operation including filter feed pumps,multigrade sand filter, activated carbon filter, antiscalant dosing, acid dosing, micron cartridge filter, RO high pressure pumps, RO moules, RO Cleaning System, valves, interconnected piping and accessories. (1W+1S) Expected Treated water characteristics after RO Treatment PH - 6.0-7.0 Total dissolved Solids - < 50 ppm Suspended Solids - NIL Turbidity - As per IS:10500 Iron as Fe - NIL Total Harness - Less Than 5 ppm
Supply, installation, testing and commissioning drinking water cooler (High quality SS Tank for Storage 80 lts) complete in all respects.
Supplying and fixing in position of approved quality Solenoid Valve with by-pass arrangement, isolation cock etc. complete with all required accessories such as level sensor, level indicator, level controller and required cabling for the same. - 25 mm dia
Supplying and fixing in position of approved quality Solenoid Valve with by-pass arrangement, isolation cock etc. complete with all required accessories such as level sensor, level indicator, level controller and required cabling for the same. - 32 mm dia
Providing and fixing water meter with direct reading dial in "KL" with all internal parts in gunmetal , strainer, flanged distance piece for easy removal in future, 100 mm dia Bourden type pressure guage and isolation cock including necessary test certificate for the meter. (For water supply metering from source). - 32 mm dia
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 500 mm diameter HDPE pipe/ RCC pipe / S. W. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 600 mm diameter HDPE pipe/ RCC pipe / S. W. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 700 mm diameter HDPE pipe/ RCC pipe / S. W. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 900 mm diameter HDPE pipe/ RCC pipe / S. W. pipe
Providing and fixing F.R.P. Grating drain cover M.S. Angle ( 35 x35 x 5 mm). ( Load Bearing cap. 5 T, suitable for car parking, basement, Pump room, Parking Area ). 377mm wide and 30mm thick
Providing and fixing 80mm dia GI pipes to IS:1239 heavy class with fittings.
Supply, Lowering, installation & testing of KSB make submersible pumping set with 10 HP motor 18 stage pump suitable for maximum capacity of 20 m3 hr. at 100 mtr. Head respectively. With Three Phase.
Providing & fixing cable 6 sq.mm. From submersible pump to panel board.
Providing & fixing Panel Board for submersible pump fitted with DOL starter ammeter, voltmeter single phase preventer standard/indo/cop make MCB of off switch push bottom duly wired and made out of 16/18 SWG sheet.
Design, Supplying, installing, testing & commissioning of Sewage Treatment Plant of 50 KLD with ultrafilteration (excluding excavation, back filling & disposal of surplus earth MS / Civil construction work) for the following duty: Sewage treatment plant shall include the following items: a. Screen chambers with SS Screen b. Equalization Tank c. Aerobic & Anoxic tank d. MBBR TANK e. Air Blowers f. MBBR Media g. Recirculation pumps, backpulse pump, permeate pump etc. h. Dewatering system j. Electrical Panel, Cabling (Power & Control), Earthing k. Tertiary Treatment l. Clear Water tank and Flushing Water tank. L. Ultra Filteration Unit M. UF Water storage tank INLET SEWAGE CHARACTERSTICS (ASSUMED) pH - 6.0 – 8.5 BOD5 : 250 - 350 mg/lit Total Suspended Solids (TSS) : 250 - 450 mg/lit COD : 500 - 700 mg/lit Oil / Grease : upto 50 mg/lit Inflow time : 24 HRS Peak factor : 3 Temperature : Ambient Desired Sewage Quality After Treatment pH : 7 - 8 BOD5 : < 10 mg/lit Total Suspended Solids (TSS) : < 10 mg/lit COD : < 50 mg/lit Oil / Grease : < 5 mg/lit Colour : Colourless Odor : unobjectionable E.coli : Nil NH4-N :< 5 mg/lit N Total :< 10 mg/lit PO4-P : 2 mg/lit Note: Vendor shall ensure submission of detailed GA drawings (Plan & Section), P&I diagram, schematic diagram for the above said component and additional component if so required for the complete working of the STP for the full capacity.
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (For Underground) 150 mm. Dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Vertical Riser/Downcomer/Floor)- 25 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Vertical Riser/Downcomer/Floor)- 32 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Vertical Riser/Downcomer/Floor)- 40 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Vertical Riser/Downcomer/Floor)- 50 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Vertical Riser/Downcomer/Floor)- 65 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Vertical Riser/Downcomer/Floor)- 80 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Vertical Riser/Downcomer/Floor)- 100 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Vertical Riser/Downcomer/Floor)- 150 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 50mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 200 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 200 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 80 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 150 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 200 mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe. (FOR UG TANK & EXTERNAL RING MAIN)
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 150mm dia
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. - 700 mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. - 1000 mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. - 1200 mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. - 1500 mm
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump). (a) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. (c) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 80 m Head
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (For Underground) 100 mm. Dia
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (For Underground) 80 mm. Dia
Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete.
Providing and fixing hose BOX of size 900mmx2100mm made of 16 gause thick MS sheet with 4 mm thick frant glass doors in front painted "FIRE" in red paint i/c recessary locking /Key arrangement shall be painted with one coat of primer & two coat of finished stove enameled post office red colour paint .
Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted "FIRE" in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant.
Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm. - 25 mm Dia
Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass ,Reducer ,union, G.I PIPE. connection to drain pipe/riser.
Supply and fixing of 4 Nos G.I round bottom FIRE BUCKET of 9 LTR. Capacity field with sand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIRE complete in all respects as per direction of Engineer Incharge .
Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with internal charge.
Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge.
Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:910 .
Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEY confirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285.
Providing and fixing 2 kg capacity clean agent-HFC 236FA Stored Pressure type fire extinguisher ISI marked under IS:15683 complete with imported Novec 1230 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2x1.5 sq.mm. + 1x1.5 sq.mm. earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2x6 sq.mm. + 1x6 sq.mm. earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2x10 sq. mm + 1x6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4x6 sq. mm + 2x6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4x10 sq. mm + 2x6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4x16 sq. mm + 2x6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ conduit as required. - 6 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ conduit as required. - 3 x 2.5 sq. mm (For Lift Shaft)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ conduit as required. - 3 x 4 sq. mm (For Lift Shaft)
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet (near equipment point) and 25 A modular SP MCB, “C” curve (at accessible point) including connections, painting etc. as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. - 20 mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. - 25 mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. - 32 mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. - 40 mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. - 5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. - 15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. - 3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. - 6 pin 15/16 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) - For Telephone,TV outlet & Data
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm) - For Socket outlet.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 8 Module (125 mmX125 mm)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying, installing by suspension on ceiling/along the wall,testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq. cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every meter, adopter box and copper flexible for joints, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. - 800 A
Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. - 800 A 50kA SC for 1 sec
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated CompType bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB (but without MCCB) complete etc. as required. 125 A, Isc = 15 kA for 1 second (For 100A Tap off)
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in the cubical panel, making connections etc. as required. (for Rising Main Tap off Box, End Fed Unit) - 100 A,30KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in the cubical panel, making connections etc. as required. (for Rising Main Tap off Box, End Fed Unit) - 125 A,36KA,FPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 8 way, Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 12 way, Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 16 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 6 Way (4+18), Double Door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 8 Way (4+24), Double Door
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. - For 8 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. - For 14 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface / recess, complete with testing and commissioning etc.as required. - For 6 way, Double door TPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface / recess, complete with testing and commissioning etc.as required. - For 8 way, Double door TPN MCBDB
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Double pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Triple pole & neutral
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. -25 Amps
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. -40 Amp
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. -63 Amp
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. - Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. - Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. - Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. - Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. - Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. - Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. - Upto 35 sq. mm (clamped with cable tie)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. - Above 35 sq. mm and upto 95 sq. mm (clamped with cable tie)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. - Above 95 sq. mm and upto 185 sq. mm (clamped with cable tie)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. - Above 185 sq. mm and upto 400 sq. mm (clamped with cable tie)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 2 X 6 sq. mm (19mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 50 sq. mm (35mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 70 sq. mm (38mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 95 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 185 sq. mm (57mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 300 sq. mm (70mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4 X 16 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4 X 10 sq. mm (25mm) (The Termination including 4 x 6 sq. mm cable)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4 X 25 sq. mm (28mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. - 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. - 120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. - 160 mm dia (OD-160 mm & ID-135 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. - 200 mm dia (OD-200 mm & ID-175 mm nominal)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 100 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 300 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 450 mm wide x 50 mm depth x 2.0 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm wide x 50 mm depth x 2.0 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm wide x 50 mm depth x 2.0 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm wide x 50 mm depth x 2.0 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 600 mm wide x 50 mm depth x 2.0 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm wide x 50 mm depth x 2.0 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 600 mm wide x 50 mm depth x 2.0 mm thickness.
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth beyond 45 cm of brick masonry chamber For 600x850 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. The contractor shall submit the structure strength calculation for approval before execution. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. - TV antenna socket outlet
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying, installation, testing & commissioning of addressable phone control module complete as required.
Supplying, installation, testing & commissioning of addressable phone / monitor control module complete as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. - 2 x 1.5 sq. mm
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Supplying, installation, testing & commissioning of 6 inches dia, 2 watts, 70/100 volts ceiling speaker complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. - Speaker cable Single pair, 2-core, 1.5 sqmm
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. - 1 Run of Cable
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. - 2 Run of Cable
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. - 3 Run of Cable
Supply,Installation,Testingand Commissioning of on grid Solar Photo voltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono / Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium / GI structure of suitable strength with following components complete as required:- a)Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants / systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800V DC Input voltage range and 400V AC, three phase, 4wire, 50Hz +/-2. 5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable alongwith glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel / conduit lugs and other accessories etc. as required. The Solar PV described as above
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm atnominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. (As per site condition, outdoor type IP-55 required) - 1000 A 50kA SC for 1 sec
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm atnominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. (As per site condition, outdoor type IP-55 required) - 800 A 50kA SC for 1 sec
Supply, installation, Testing & Commissioning of 30 Watt Recess mount, 6500K, LED light fixture, of size 2' x 2', having minimum system lumen output of 100 Lumen / watt complete as requried.
Supply, installation, Testing & Commissioning of 15 Watt Recess mounted LED Down Light, 6500K, having minimum system lumen output of 100 Lumen / watt complete as requried.
Supply, installation, Testing & Commissioning of 40W Watt LED batten Light (1200mm), 6500K, weather proof (IP-65) having minimum system lumen output of 100 Lumen / watt complete as requried.
Supply, installation, Testing & Commissioning of 10 Watt Surface mounted LED Down Light, 6500K, having minimum system lumen output of 100 Lumen / watt complete as requried.
Supply, installation, Testing & Commissioning of 7-10 Watt Bulkhead LED Light, 6500K, having minimum system lumen output of 100 Lumen / watt complete as requried.
Supply, installation, Testing & Commissioning of 10 Watt LED batten Light (600mm), 6500K, having minimum system lumen output of 100 Lumen / watt complete as requried. (Mirror Light)
Supply, installation, Testing & Commissioning of 18-20 Watt LED batten Light (1200mm), 6500K, having minimum system lumen output of 100 Lumen / watt complete as requried.
Supply, installation, Testing & Commissioning of 10-12 Watt Recess mounted LED Down Light, 6500K, having minimum system lumen output of 100 Lumen / watt complete as requried.
Supply, installation, Testing & Commissioning of 18 Watt Recess mounted LED Down Light, 6500K, having minimum system lumen output of 100 Lumen / watt complete as requried.
Supply, installation, Testing & Commissioning of 36 Watt Recess mount, 6500K, LED light fixture, of size 2' x 2', having minimum system lumen output of 100 Lumen / watt complete as requried.
Supplying and fixing of 300 mm sweep decorative Fresh air fan with all accessories suitable for operation single phase 230 volt 50 cycle per second per sec. AC supply etc. as required. in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning earthing etc. as required.
Supply, installation, Testing & Commissioning of 15 Watt Decorative wall mounted Bracket Light, 6500K, LED light fixture complete as requried.
Supply, installation, Testing & Commissioning of Chandelier Light, Mushroom shape, Chrome colour, Clear curving glass mushroom strip, 6X42 Watt G9 Halogen Lamp complete as requried. (Philips Cat. No. 581861 or equivalent)
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in the cubical panel, making connections etc. as required. (for Rising Main Tap off Box, End Fed Unit) - 800 A,50KA,FPMCCB
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 12 way (4 + 36), Double door
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface / recess, complete with testing and commissioning etc.as required. - For 12 way, Double door TPN MCBDB
Supplying and fixing following rating, double pole, 240 volts, MCB complete with connections, testing and commissioning etc. as required. - 40 Amp
Supplying and fixing of following rating, 240/415 volts, "C" curve, four pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp Triple pole & neutral MCB
Supplying and fixing of following rating, 240/415 volts, "C" curve, four pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp Triple pole & neutral MCB
Supplying and fixing FP sheet steel enclosure on surface/ recessed, 415 V curve FP MCCB/MCB complete with connections, testing and commissioning etc. as required. - 63 Amp FP MCCB
Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. L+P PANEL-1 (GROUND FLOOR) INCOMING 1 No. 100 Amp FP Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with MCB. 1 Set of ON/OFF indicating lamps with MCB. 1 No. Digital MFM with CT's. BUSBAR 150 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 4 Nos. 63 Amp FP Miniature Circuit Breaker. 3 Nos. 40 Amp FP Miniature Circuit Breaker. 2 Nos. 25 Amp FP Miniature Circuit Breaker. Panel described as above
Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. L+P PANEL-2 (FIRST FLOOR) INCOMING 1 No. 125 Amp FP Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with MCB. 1 Set of ON/OFF indicating lamps with MCB. 1 No. Digital MFM with CT's. BUSBAR 150 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 2 Nos. 63 Amp FP Miniature Circuit Breaker. 3 Nos. 40 Amp FP Miniature Circuit Breaker. 3 Nos. 40 Amp DP Miniature Circuit Breaker. 14 Nos. 25 Amp DP Miniature Circuit Breaker. Panel described as above
Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. L+P PANEL-3 (SECOND FLOOR) INCOMING 1 No. 100 Amp FP Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with MCB. 1 Set of ON/OFF indicating lamps with MCB. 1 No. Digital MFM with CT's. BUSBAR 150 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 2 Nos. 63 Amp FP Miniature Circuit Breaker. 8 Nos. 40 Amp FP Miniature Circuit Breaker. 2 Nos. 40 Amp DP Miniature Circuit Breaker. Panel described as above
Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. L+P PANEL-4 (THIRD FLOOR) INCOMING 1 No. 125 Amp FP Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with MCB. 1 Set of ON/OFF indicating lamps with MCB. 1 No. Digital MFM with CT's. BUSBAR 150 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 2 Nos. 63 Amp FP Miniature Circuit Breaker. 5 Nos. 40 Amp FP Miniature Circuit Breaker. 10 Nos. 40 Amp DP Miniature Circuit Breaker. 2 Nos. 25 Amp DP Miniature Circuit Breaker. Panel described as above
Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. L+P PANEL-5 (FOURTH FLOOR) TYPICAL FOR 5TH FLOOR INCOMING 1 No. 125 Amp FP Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with MCB. 1 Set of ON/OFF indicating lamps with MCB. 1 No. Digital MFM with CT's. BUSBAR 150 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 2 Nos. 63 Amp FP Miniature Circuit Breaker. 4 Nos. 40 Amp FP Miniature Circuit Breaker. 10 Nos. 40 Amp DP Miniature Circuit Breaker. 12 Nos. 25 Amp DP Miniature Circuit Breaker. Panel described as above
Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. MAIN UPS PANEL (2X30 KVA) INCOMING 2 Nos. 100 Amp FP Moulded Case Circuit Breaker. 2 Set of phase indicating lamps with MCB. 2 Set of ON/OFF indicating lamps with MCB. 2 No. Digital MFM with CT's. BUSBAR 100 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 2 Nos. 40 Amp DP Minitaure Circuit Breaker. 15 Nos. 25 Amp DP Minitaure Circuit Breaker. Panel described as above
Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. LIFT PANEL INCOMING 1 No. 125 Amp FP Moulded Case Circuit Breaker.. 1 Set of phase indicating lamps with MCB. 1 Set of ON/OFF indicating lamps with MCB. 1 No. Digital MFM with CT's. BUSBAR 150 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 7 Nos. 63 Amp FP RCBO. 2 Nos. 32 Amp FP Miniature Circuit Breaker. 4 Nos. 25 Amp DP Miniature Circuit Breaker. Lift Panel described as above
Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. VENTILATION PANEL (OUTDOOR TYPE) INCOMING 1 No. 125 Amp FP Moulded Case Circuit Breaker.. 1 Set of phase indicating lamps with MCB. 1 Set of ON/OFF indicating lamps with MCB. 1 No. Digital MFM with CT's. BUSBAR 150 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 14 Nos. 25 Amp FP Miniature Circuit Breaker. Lift Panel described as above
Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. VRV OUTDOOR UNIT PANEL (OUTDOOR TYPE) INCOMING 2 Nos. 630 Amp FP Moulded Case Circuit Breaker. 2 Set of phase indicating lamps with MCB. 2 Set of ON/OFF indicating lamps with MCB. 2 No. Digital MFM with CT's. BUSBAR 1 Nos. 630 Amp FP Moulded Case Circuit Breaker. Mechanical interlock facility. OUTGOING 2 Nos. 160 Amp FP Moulded Case Circuit Breaker. 5 Nos. 125 Amp FP Moulded Case Circuit Breaker. 7 Nos. 100 Amp FP Moulded Case Circuit Breaker. 5 Nos. 63 Amp FP Moulded Case Circuit Breaker. Panel described as above
Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. KITCHEN PANEL-1 (GROUND FLOOR) (TYPICAL FOR KITCHEN PANEL-2 FIRST FLOOR) INCOMING 1 No. 160 Amp FP Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with MCB. 1 Set of ON/OFF indicating lamps with MCB. 1 No. Digital MFM with CT's. BUSBAR 200 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. Mechanical interlock facility. OUTGOING 1 Nos. 100 Amp TP+N Moulded Case Circuit Breaker. 1 Nos. 63 Amp TP+N Moulded Case Circuit Breaker. 5 Nos. 63 Amp FP Miniature Circuit Breaker. 7 Nos. 40 Amp FP Miniature Circuit Breaker. 10 Nos. 32 Amp DP Miniature Circuit Breaker. 4 Nos. 40 Amp DP Miniature Circuit Breaker. Panel described as above
Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. LIFT DB (TYPICAL) INCOMING 1 No. 63 Amp FP RCBO, 300 mA. 1 No. 16 Amp DP Miniature Circuit Breaker. 1 No. 10 Amp DP Miniature Circuit Breaker. Lift DB described as above
Supplying of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable (UE) complete as required. 3 core x 185 sq. mm
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : - 185 sq. mm
Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Aluminum Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. - 3.5 core, 300 sq.mm.
Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Aluminum Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. - 3.5 core, 185 sq.mm.
Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Aluminum Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. - 3.5 core, 50 sq.mm.
Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Aluminum Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. - 3.5 core, 35 sq.mm.
Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Aluminum Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. - 4 core, 25 sq.mm.
Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Aluminum Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. - 3.5 core, 120 sq. mm. Al. Fire Survival Cable
Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Aluminum Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. - 3.5 core, 70 sq. mm. Al. Fire Survival Cable
Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Copper Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. - 4 core, 16 sq.mm.Cu.Cable
Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Copper Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. - 4 core, 16 sq.mm.Cu. Fire Survival Cable
Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Copper Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. - 4 core, 6 sq.mm.Cu. Fire Survival Cable
Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Copper Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. - 2 core, 6 sq.mm.Cu. Cable
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification. 100 mm wide x 40 mm deep.
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification. - 150 mm wide x 50 mm deep.
Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor FRLS insulated wire including termination complete as required in existing cable tray. 1C x 16 sq.mm PVC Insulated cu wire including end termination.
30 KVA UPS WITH 30 MINUTES BATTERY BACKUP Supply, installation, testing & commissioing of 30 KVA UPS in paralleling mode at 0.99 input power factor with inbilt isolation transformer as per specification given in the document with following broad features. THD(i) shall be less than 3% in the entire loading range. UPS shall carry design output at 40 deg. Shall have soft start and hold of for incoming supply. Invertor capability to supply 150% load for 5 sec. Three Phase Input and Three Phase Output. (Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.) Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells. Battery shall be external type with rack and suitable for 30 minute backup on 100% load. UPS shall be compatible for minimum 3 nos unit in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS. Suitable size cable from UPS to battery bank. UPS described as above
Fabricating and supply, Installation, Testing & Commissioning of 6.0 metre long M.S. Ribbed steel tubular pole having 3 steps. Bottom portion shall be 2 metre long having outer dia 140 mm of thickness 4.0 mm, middle portion shall be 2.5 mm long having outer dia 114.0 mm with thickness of pipe 3.0 mm and top portion shall be 1.46 metre long having outer dia 89.0 mm with thickness of pipe 3.0 mm including providing and fixing MS plate 450mm x 450mm x 10mm, drilling holes for earthing and wire entry etc. as required. The pole shall be with in built cable loop-in box including 10/20 A SP MCB, terminal block earth stud, 1 meter long single arm etc. The diameter of arm shall be suitable for light fixture installation. The pole shall be PU painted with 90 micron thick of approved colour.
Supply and erection of 3 Mtr height Octagonal pole 140mm bottom & 70mm on top with openable door/window & the following size made with 3mm thick hot dip galvanised sheet with 200mm x 200mm x12mm thick base plate welded at bottom & making cement concrete ( 1 Cement : 2 coarse sand : 4 stone) CC foundation of size 500mm x 500mm x 750mm (LxWxD) with suitable reinforcement cement including supplying fixing of 4 Nos 16mm dia 700mm long J type foundation bolt with anchor plates & nuts HDPE/HARD 65mm dia pipe for cable entry and supplying and fixing of 1.00 Mtr long single arm suitable bracket for installation of fitting & supplying and fixing 1 Nos 16 Amp C serice MCB i/c suitable size 3 Nos aluminium bus bar strip, 6mm thick bakelite sheet, din bar with accessories etc. complete as reqd.
Supply, Installation, Testing & Commissioning of LED light fixture 45 watt, 4500 lumen, integral driver, protection IP 66, CLASS I as complete as required and as per tender specification.
Supply, Receiving, Unloading, Shifting, Installation, Testing & commissioning of 45W LED Post Top Light for Gate Light including all fixing accessories as required.
Supply, Installation, Testing & commissioning of outdoor type (IP 65) Bollard Light 100 mm dia, 800 mm height made out of cast aluminium, 8 up to 10 W LED Light with minimum 340 lumen, 100 lumen / watt, warm white, stainless steel screw, corrossion & UV resistant coat etc as complete as required.
Supply, Receiving, Unloading, Shifting, Installation, Testing & commissioning of 6-8W LED Planter Light complete as required.
11KV H.T. METERING PANEL (INDOOR TYPE): Supply, Installation, Testing & Commissioning of indoor type floor mounted, dust, damp and vermin proof, cubicle HT. Metering Panel made out of 14 gauge CRCA sheet steel complete with 5Amp electronic trivector meter, C.T.'s of 40/5Amp, 0.5 Class, 10VA Burden, and P.T's of 11KV/ /3, 110V/ /3, 100 VA conforming to relevant IS Standards and complete as required. H.T. Metering cubicle along with C.T.'s, P.T.'s and trivector meter shall be got tested and approved from local electricity supply authority. The GA drawing shall be got approved by Electricity Board authorities before fabrication.
500 KVA, 11KV/415V OIL TYPE TRANSFORMER Design, manufacture, supply, installation, testing and commissioning of 500 KVA, 11 KV /0.415 KV, 3 phase, 50 Hz delta/star-11 connected, Out Door Type, copper wound transformer, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent with on Load Tap changing (OLTC) arrangement on HV side with Tapping for variations of high voltage from (+) 5% to (-)15% in steps of 1.5% each with integrated microprocessor based RTCC Panel, bi-directional roller, diagrams & rating plate, Oil temperature indicator, & Winding temperature indicator, Buchholz relay, weather proof Marshalling Box, lifting lugs, first filling of oil, weather proof H.Tcable box & L.T Bus duct arrangement etc. complete as per specification. All relays, contacts & CT terminals to be wired upto marshalling box. Transformer Losses shall be as per latest ECBC Building requirements of draft ECBC 2017 (1600 Watt in 50% load and 4750 Watt in 100% load)
SAFETY EQUIPMENT First aid box as approved by St.John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963.
Shock treatment chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English).
Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652 -2006.
Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006.
Supplying and installing at approved location approved make fire buckets (6 No.) of 24 gauge galvanized steel sheet conforming to IS: 2546, standard 9.5 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer.
Supply & Laying of following sizes of 1.1KV grade multicore copper conductor PVC insulated and PVC sheathed armoured control cable conforming to IS:7098 (Part-I) 1988, including end termination with brass compression gland and copper lugs. - 2 core, 6.0 sq.mm
Supply & Laying of following sizes of 1.1KV grade multicore copper conductor PVC insulated and PVC sheathed armoured control cable conforming to IS:7098 (Part-I) 1988, including end termination with brass compression gland and copper lugs. - 4 core, 1.5 sq.mm
Supply & Laying of following sizes of 1.1KV grade multicore copper conductor PVC insulated and PVC sheathed armoured control cable conforming to IS:7098 (Part-I) 1988, including end termination with brass compression gland and copper lugs. - 8 core, 1.5 sq.mm
Supply & Laying of following sizes of 1.1KV grade multicore copper conductor PVC insulated and PVC sheathed armoured control cable conforming to IS:7098 (Part-I) 1988, including end termination with brass compression gland and copper lugs. - 12 core, 1.5 sq.mm
Design, Manufacturing, Supply, Installation, Testing and Commissioning of 600 KVA Radiator Cooled DG sets with Accoustic Enclosure, db level as per latest CPCB, 415 Volts, 3 phase 4 wire, 50 Hz AC alternator coupled to diesel engine with Electronic Governer Suitable for Auto Load Sharing and Auto Synchronizing System complete with all accessories, standard specifications tool kits, service manual, self starting device, fly wheel, coupling with guard, V velt, radiator, instrument panel (starting switch with key, Water Temperature indicator gauge, Lub OIl Pressure gauge, Lube oil temperature gauge, Battery Charging Ammeter, indicating lamp, hour counter etc.), residential silencer, common bed plate, anti vibration isolation pads, extended termination box for bus duct/Cable termination, grouting bolts, first charge of engine oil, gear oil, high speed diesel oil, 24 volt maintenance free chargeable battery set with Trickle/Boost Battery charger, interface card for BMS connectivity complete as required of rating 415 Volts, 3 phase 4 wire, 50 Hz. AC alternator coupled to Diesel Engine complete with all accessories. The alternator insulation shall be class 'H' with temperature rise limited to Class 'H' value suitable to with stand tropical conditions and shall generally comply with BS 5000 and IS 4722. The over load capacity shall not be less than 110% of rated capacity for 1 hour in every 12 hours. NOC from concerned goverment authority for installation and operation of D.G. set shall be taken by contractor. D.G. Set shall be as per Latest CPCB.
Supply, Installation, Testing and Commissioning of following sizes MS exhaust piping heavy duty conforming to IS:3589 complete with all accessories such as bends, flanges, stainless steel flexible bellows etc. as required. - 250 mm dia MS pipe. (5.0 mm thick)
Providing & Fixing of Insulation and aluminium cladding for exhaust piping using 75 mm thick rockool of density 150 Kg/ M3 & 24 SWG Aluminium Sheet.
Supply, erection, testing and commissioning of following sizes of splitter of aluminium die cast body in suitable size of G.I. Box. - 4 way
Supply, erection, testing and commissioning of following sizes of splitter of aluminium die cast body in suitable size of G.I. Box. - 6 way
Supply, erection, testing and commissioning of following sizes of splitter of aluminium die cast body in suitable size of G.I. Box. - 8 way
Supply ,Installation ,Testing & Commossioning of 3 MP Dome Camera, ONVIF profile S & G , UL,CE,FCC certified , Motorized varifocal 3mm to 9 mm ,1/2.8" CMOS sensor , Quad stream, frame rate : H.264 3M (2048 X 1536) @25/30 fps, 2 MP (1920 X 1080) @ 50/60 FPS, Shutter speed : 1 ~1/10000 sec , P-iris , Min illumination : Color 0.04 lux , B/W 0.002 lux , Auto ICR ,Two way audio support ,Video compression : H.264/H.265 ,MJPEG ,120 dB WDR ,Auto white balance , SD Card support ,Support upto 20 user accounts , 1 X BNC analog output ,Digital Zoom ,Digital PTZ ,2D / 3D Noise reduction, Edge analytics : Abandoned Object, Intrusion Detection, Tampering, Wrong Direction, Loitering Detection, Object Counting, Stopped Vehicle, Object Removal , InbuiltIR LEDs , IR distance upto 40 mtrs , IP 66 weather proof , IK 10 Vandal proof ,POE.
Supply ,Installation ,Testing & Commossioning of 3 MP Bullet Camera , ONVIF profile S & G , UL,CE,FCC certified , Motorized varifocal 2.8mm to 12 mm ,1/2.8" CMOS sensor , Quad stream, frame rate : H.264 3M (2048 X 1536) @25/30 fps, 2 MP (1920 X 1080) @ 50/60 FPS, Shutter speed : 1 ~ 1/10000 sec , P-iris , Min illumination : Color 0.1 lux , B/W 0.01 lux , Auto ICR ,Two way audio support ,Video compression : H.264/H.265 , MJPEG ,120 dB WDR ,Auto white balance , SD Card support ,Support upto 20 user accounts , 1 X BNC analog output ,Digital Zoom ,Digital PTZ ,2D / 3D Noise reduction, Edge analytics : Abandoned Object, Intrusion Detection, Tampering, Wrong Direction, Loitering Detection, Object Counting, Stopped Vehicle, Object Removal InbuiltIR LEDs , IR distance upto 40 mtrs , IP 67 weather proof ,IK 10 , POE
Supply, Installation, Testing & Commissioning of 6TB HD.
Supply, Installation, Testing & Commissioning of 65" LED panels as per Specification.
Supply , Installtion , Testing and comissioning of CAT6 information outlet (I/O) for CCTV.
Supply , Installtion , Testing and Comissioning of CAT 6A F/UTP cable solid copper conductors as per technical specification.
Supply , Installtion , Testing and Comissioning of CAT6A Shielded information outlet (I/O) for Data, Voice & Wi-Fi rack end etc as per technical specification.
Supply , Installtion , Testing and Comissioning of loaded 24 port CAT 6A jack panel for CAT6A cable termination etc as per technical specification.
Supply , Installtion , Testing and Comissioning of loaded 48 port CAT 6A jack panel for CAT6A cable termination etc as per technical specification.
Supply , Installtion , Testing and Comissioning of CAT 6A Shielded patch cord 3 feet for rack side switch termination for user End etc as per technical specification.
Supply , Installtion , Testing and comissioning of CAT 6A Shielded patch cord 7 feet for user termination to information outlet Rack End etc as per technical specification.
Supply , Installtion , Testing and comissioning of 1, 2 and 4 port face plate white for I/O fixing at user side in cluding back box etc as per technical specification.
Supply , Installtion , Testing and comissioning of 42 U (800W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts, power distribution system etc etc as per technical specification.
Supply , Installtion , Testing and comissioning of 15U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts, power distribution system etc as per technical specification.
Supply, Installation, Testing & Commissioning of 12 Core, Multi Mode, OM4 etc as complete as required and as per technical specification.
Supply, Installation, Testing & Commissioning of LC-LC, OM4 MM Patch Cord, 10 Feet 50/125etc as complete as required and as per technical specification.
Supply, Installation, Testing & Commissioning of 12 port LC multimode loaded LIU including pigtail etc as complete as required and as per technical specification.
Supply, Installation, Testing & Commissioning of Core Switch with switching capacity of 1.4Tbps, forwarding performance of 1Bpps with 32x 1/10G SFP+ ports plus 4x 40G QSFP+ ports from day 1, dual hot swappable internal power supply, 60K IPv6 routes and 48K IPv6 multicast routes. Should support advance layer 3 (RIPng, OSPF, BGP and MPLS) with 1 year support. Stack Module/40 Gig Optics and all other Cables should be included in Day 1.
Supply, Installation, Testing & Commissioning of L3 distribution Switch with switching capacity of 1.4Tbps, forwarding performance of 1Bpps with 32x 1/10G SFP+ ports plus 4x 40G QSFP+ ports from day 1, dual hot swappable internal power supply, 60K IPv6 routes and 48K IPv6 multicast routes. Should support advance layer 3 (RIPng, OSPF, BGP and MPLS) with 1 year support. Stack Module/40 Gig Optics and all other Cables should be included in Day 1.
Supply, Installation, Testing & Commissioning of 24 Port PoE Access Switches with switching capaticy of 128 Gbps, forwarding performance 95 Mpps, having 24 x 10/100/1000BASE-T PoE-plus(RJ45) with minimum PoE budget of 370W and 4x 10G SFP+ uplink ports . Should support min 2GB internal DRAM, 2GB internal Flash memory,32K MAC address, 1K IPv6 Multicast Routes, Should have static Routes from day 1.One year support etc as complete as required and as per technical specification.
Supply, Installation, Testing & Commissioning of 48 Port POE Access Switches with switching capaticy of 256 Gbps, forwarding performance 190 Mpps, having 48 x 10/100/1000BASE-T PoE-plus (RJ45) with minimum PoE budget of 740W and 4x 10G SFP+ uplink ports . Should support min 2GB internal DRAM, 2GB internal Flash memory,32K MAC address, 1K IPv6 Multicast Routes, Should have static Routes from day 1.One year support etc as complete as required and as per technical specification.
Supply, Installation, Testing & Commissioning of 24 Port Non-PoE Access Switches with switching capaticy of 128 Gbps, forwarding performance 95 Mpps, having 24 x 10/100/1000BASE-T PoE-plus(RJ45) with minimum PoE budget of 370W and 4x 10G SFP+ uplink ports . Should support min 2GB internal DRAM, 2GB internal Flash memory,32K MAC address, 1K IPv6 Multicast Routes, Should have static Routes from day 1.One year support etc as complete as required and as per technical specification.
Supply, Installation, Testing & Commissioning of 48 Port Non-POE Access Switches with switching capaticy of 256 Gbps, forwarding performance 190 Mpps, having 48 x 10/100/1000BASE-T PoE-plus (RJ45) with minimum PoE budget of 740W and 4x 10G SFP+ uplink ports . Should support min 2GB internal DRAM, 2GB internal Flash memory,32K MAC address, 1K IPv6 Multicast Routes, Should have static Routes from day 1.One year support etc as complete as required and as per technical specification.
Supply, Installation, Testing & Commissioning of fiber Modules 10G.
Supply, Installation, Testing & Commissioning of Internet Security solution with minimum of 500 users from day one with one year subscription/license and flexibility to scale up to 1000 users in future having 99% uptime with each level redundancy, single pane of glass for reporting multi-location and roaming users environment for all the asked features with minimum 3 months of logs retention capacity. OEM must be Leaders in Gartner Magic Quadrant in the latest report (2017 and above) and must have features etc as complete as required and as per technical specification.
Supply, Installation, Testing and Comissioning of 4x4 MIMO AP Ac/a/b/g/n technology Support ,Should be able to act as controller in case of main controller failure and the failover should eb automatic with no manual intervention . Should have complete distributed architecture with Controller for traffic management. Stateful Firewall, IPSEC, RADIUS server support, NAT support and integrated PoE support, IDS support in hardware etc as complete as required and as per technical specification.
Supply, Installation, Testing and comissioning of Load Balancer as per technical specification and tender makes.
Supply, Installation, Testing and comissioning of IP Based voice Communication System with 04 Port Voicemail ,04 Port FXS ,04 Port FXO ,1 PRI Trunk lines (30 Ch) Circuit with CLIP Facility , 300 IP users License ,01 Nos. IP Operator Console,100 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference, Call Barring, Call Pickup, Redundant server in active-Active mode.
Supply, Installation, Testing and comissioning of Type 1 IP Phone. Graphic LCD display with backlight 3 user accounts with multi-line appearance keys Local and company-wide phone directories.
Supply, Installation, Testing and comissioning of Type 2 IP Phone 1 VoIP account , Full duplex speaker phone, IPV6, 2xLAN, PoE.
Machinery Variable Refrigerant Volume / Flow Air-conditioning System Supply, Instalaltion, testing and commissioning of Variable Refrigerant Flow /Volume (VRF/VRV) (with the latest technology/version) with All-Inverter driven Compressor, modular type airconditioning system with stepless modulation for both heating & cooling modes, complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping with insulation, Y joints, full charge of refrigerant gas including additional top up and oil, control cabling etc. as per detail given in specifications and having following items. The prices to be given in Indian rupees including all taxes and duties and delievered at site. Refrigerant to be used shall be - R 410 A only. It shall be complete as per specifications,with connectivity to automation for A/M status, RUN status & Remote start/stop command. (Bacnet/IP) with multi connection kits for each outdoor unit & First charge of refrigerant gas for the VRF/VRV Units & required MS frame work or required foundation & anti vibration pads for mounting the outdoor units. installation, testing & commissioning of air cooled VRV/VRF system shall include pipe pressure testing & flushing with nitrogen, charging of gas/oil etc. & will include all lifting/shifting etc. Air Cooled VRV / VRF Outdoor Unit Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at50°Cambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 . 18 H.P Cool / Heat Pump Unit
20 H.P Cool / Heat Pump Unit
24 H.P Cool / Heat Pump Unit
32 H.P Cool / Heat Pump Unit
40 H.P Cool / Heat Pump Unit
42 H.P Cool / Heat Pump Unit
44 H.P Cool / Heat Pump Unit
50 H.P Cool / Heat Pump Unit
54 H.P Cool / Heat Pump Unit
58 H.P Cool / Heat Pump Unit
Indoor Units Supply, Instalaltion, testing and commissioning of Indoor units equipped with pre-filter, fan section with suitable static fan to distribute the air as per approved shop drawings, multispeed motor, coil section with DX coil, outer cabinet / cassette panel, drain pan, insulation, pipe connections etc. of various capacities as per specifications and drawings. Cassette Unit - Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 0.8 TR
Ductable Unit - Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Low static ductable units (minimum 25 pascal external static pressure) 0.8 TR, Low Static Ductable units (minimum 25 pascal external static pressure)
Low static ductable units (minimum 25 pascal external static pressure) 1.0 TR, Low Static Ductable units (minimum 25 pascal external static pressure)
Low static ductable units (minimum 25 pascal external static pressure) 1.3 TR, Low Static Ductable units (minimum 25 pascal external static pressure)
Low static ductable units (minimum 25 pascal external static pressure) 1.6 TR, Low Static Ductable units (minimum 25 pascal external static pressure)
Mid Static Ductable units (minimum 45 pascal external static pressure) 2.0 TR, Low Static Ductable units (minimum 45 pascal external static pressure)
Machinery 2.6 TR, Low Static Ductable units (minimum 45 pascal external static pressure)
Machinery 4.0 TR, Low Static Ductable units (minimum 45 pascal external static pressure)
High Static Ductable units (minimum 110 pascal external static pressure) 8.0 TR, High Static Ductable units (minimum 110 pascal external static pressure)
Indoor Units (Ceiling Mounted Low / Medium / High Static Ductable / FCU / Outdoor Air Processing Unit (TFA) & Cassette Units) Medium Static Ductable Unit 4.6 TR (1624 CFM) Ductable Type VRV Indoor Unit
High Staitc Ceiling Mounted Outdoor Air Processing Unit (TFA) 4.0 TR (650 CFM) Ductable Type VRV TFA Unit
High Staitc Ceiling Mounted Outdoor Air Processing Unit (TFA) 6.4 TR (1000 CFM) Ductable Type VRV TFA Unit
High Staitc Ceiling Mounted Outdoor Air Processing Unit (TFA) 8.0 TR (1200 CFM) Ductable Type VRV TFA Unit
Ceiling Mounted Corner Type Cassette Units Ceiling Mounted Cassette Type : 0.8 TR
Ceiling Mounted Corner Type Cassette Units Ceiling Mounted Cassette Type : 1.6 TR
Ceiling Mounted Corner Type Cassette Units Ceiling Mounted Cassette Type : 2.0 TR
Ceiling Mounted 2 Way Type Cassette Units Ceiling Mounted Cassette Type : 0.8 TR
Ceiling Mounted 2 Way Type Cassette Units Ceiling Mounted Cassette Type : 1.6 TR
Ceiling Mounted 2 Way Type Cassette Units Ceiling Mounted Cassette Type : 2.0 TR
Y-joints For Indoor Unit Supply,installation,testing and commissioning of Imported Y/T refnet Joints with insulation to connect indoor units with main header as per drawing. It should be complete as per manufacturing standards & as per directions of Engineer-in-charge . (1 Set will comprise of 2 Y/T Refnet Joints each for sution & discharge side)
Machinery Self Diagnostic Type Individual Remote Controllers (Corded Type) Supply, Installation, Testing & Commissioning of Corded Wall Mounted Type Self Diagnostic Type Digital Programmable Individual Remote Controllers of latest generation for setting required temperature for various Indoor Unit.
Main Intelligent Programmable Central Controller (Corded Type Suitable for 64 Units) Supply, installation, testing and commissioning of Main centralized controller / manager digital type of latest generation for VRV/VRF system for controlling all the indoor & outdoor units installed in building with adapters (for connecting additional indoor units, cost for the same is deemed to be included in this item) with On / Off, touch screen and Temparature Controls, fan speed, scheduling, air flow direction setting, operation history etc. The controller should be compatible with automation system (Bacnet/IP) with all accessories. It should be complete as per manufacturing standards & as per directions of Engineer-in-charge.
400 to 700 CFM (15mm static pressure, single phase)
800 to 1000 CFM (15mm static pressure, single phase)
1100 to 1500 CFM (15mm static pressure, single phase)
400 to 800 CFM
12000 CFM (25mm static pressure, Axial Fan, 1000 RPM, 3.7 Kw Fan Motor or as required, 800 MM Fan Dia)
8000 CFM (25mm static pressure, Axial Fan, 1000 RPM, 2.2 Kw Fan Motor or as required, 700 MM Fan Dia)
Kitchen Scrubber Unit Dry Type in Double Skin Construction: Supply, installation, testing and commissioning of Double Skin Dry Scrubber Unit comprising of Electrostatic Precipitator Module, SISW Exhaust Air Fan & Accessories as required. Electrostatic section shall in double skin construction made of 22 gauge galvanized sheet with inner sheet high bake epoxy powder coated, washable type Aluminum mesh pre filters, Suitable SISW Backward Curved Kitchen Exhaust Air Fan complete with TEFC Induction Motor, Drive Assembly, Base Frame, Vibration Isolators and other accessories, wire ionizers to create high voltage DC field, aluminum collector plates which should be alternatively charged positive and negative with large collecting area, to work as magnet for charged smoke and oil particles. Average efficiency of 90-95% as per DOP test method. Electrostatic Precipitator should be able to charge the particles from 0.01 micron to 10 microns through stable power supply. Collector cell should be of permanent type and incorporate facility for easy removal for cleaning. The system should be fitted with appropriate overload protection and safety interlock. Operating Voltage – 220V, 50 Hz. Ionizing Voltage – 12.5 – 13 KVDC. Collector Cell Voltage – 6 – 7 KVDC. 7,000 CFM, 1 x 500 mm Dia. Fan, 1 x 5.6 Kw Fan Motor, 80 mm St. Pressure
Factory Fabricated Double Skin Airwasher: Supply, installation, testing and commissioning of factory fabricated Double Skinned Air-washer unit floor mounted type fabricated out of extruded aluminium section with 0.6mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.6 mm plain Galvanised steel sheet inside with blower, blower section and blower motor TEFC (EFF1) type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, belt drive package, wet section & tank shall be made of 18 G stainless steel. The Air-washer shall be complete with fill of depth 200 mm & face velocity across the fill shall be limited to 152 MPM. The Air-washer shall have an efficiency of 90% & shall be complete with water circulation pump GI B Class interconnecting piping & valves Aluminum viscous filters. The Air-washer shall have an efficiency of 90% & shall be complete with water circulation pump GI B Class interconnecting piping & valves Aluminum viscous filters. The airwasher panels shall be insulated with 23mm thick & 36 Kg/m³ density PU foam. The Airwasher shall conform to specication given in the tender & shall be of following capacity. 6,000 CFM, 1 x 450 mm Dia. Fan, 1 x 3.7 Kw Fan Motor, 50 mm St. Pressure, Monoblock Pump.
Condensate Drain Piping: Supply, installation, testing and commissioning of UPVC condensate drain water piping of density 20 Kg/m³ complete with fittings like elbows, tees, reducers, bends, flanges, supports, insulation etc. as required and of following sizes. 25 mm dia pipe, 13 mm Insulation
32 mm dia pipe , 13 mm Insulation
40 mm dia pipe , 13 mm Insulation
Refrigerant Piping for VRV / VRF System Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Rectangular GI Ducting (Factory Made - L Shape): Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 24 G, Thickness 0.63 mm sheet (Up To 750 mm)
22 G, Thickness 0.80 mm sheet (751 to 1500 mm)
20 G, Thickness 1.0 mm sheet (1501 to 2250 mm)
18 G, Thickness 0.80 mm sheet (Above 2250 mm)
Site Fabricated GI Ducting: Supply, installation, balancing and commissioning of site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 24 G, Thickness 0.63 mm sheet (Up To 750 mm)
22 G, Thickness 0.80 mm sheet (751 to 1500 mm)
20 G, Thickness 1.0 mm sheet (1501 to 2250 mm)
18 G, Thickness 0.80 mm sheet (Above 2250 mm)
Duct Accoustic Lining: Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
Duct Insulation: Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19 mm
Grilles, Diffusers, VCD: Supply, installtion and testing of Powder coated Aluminium extruded grills / diffusers as per specifications given in tender and of following sizes. Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Fresh / Exhaust air louvers with bird screen & damper
Supplying, fixing testing commissioning of Volume control GI Dampers to be provided in Supply / Exhaust air registers / terminals.
Supplying, fixing testing commissioning of Fixed bar linear air register of following sizes 150 mm
Constant Air Volume Regulator Supply, installation, testing and commissioning of constant air volume regulator having a plastic control flap with stainless steel balancing spring, self regulating PVC valve, piston and spring stream of following CFM for fresh air / exhaust air collar. 40 CFM
Under Deck Insulation of Exposed Roof : Supplying and fixing of thermal insulation on exposed roof (underdeck) with 19 mm thick Cross Linked Closed Cell Polyethylene FR-XPE insulation of density 33 Kg/m³ with adhesive (pidilite SR -998) etc. as required & finally fixed with the help of rawl plug & dash fasteners in ceiling.
Electrical Sub Panel : Supply, installation, testing and commissioning of cubical wall / floor mounted type switch board as detailed below & switch gears suitable for AC-23 duty with digital energy meter on incoming feeders of all Sub-Panels covered under this Item, including making interconnection etc as required. BMS compitable dual source energy meter with maximum demand shall be taken in main incomer of HVAC Panels. M.C.C. For 22 To 40 HP VRV Outdoor Units (Panel Suitable For Outdoor Type - IP54), Location Near ODU
40 / 63 A 4 pole RCBO for VRV Outdoor Units with sheet metal enclosure, rain protection etc. as required to suit the site condition. Axial Fan Motor Up to 3.7 KW
Starter for Propeller / Inline fan (Single Phase) Supply, Installation, Testing & Commissioning of modular type single phase motor starter up to 6 A / 10 A / 16 A (Rating shall be as per motor) including suitable size G.I. Box with modular, modular cover plate, conduiting and wiring from starter to fan etc as required at site.
Power & Control Cabling Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. Power cabling of XLPE insulated Aluminium conductor armoured cables of 1.1 KV Grade including cable end termination with brass compression glands & aluminium lugs etc as per specification. For Motor Up to 3.73 Kw 1 x 3C x 4 Sq. mm
Power & Control Cabling Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. Power cabling of XLPE insulated Aluminium conductor armoured cables of 1.1 KV Grade including cable end termination with brass compression glands & aluminium lugs etc as per specification. For Motor of 5.5 Kw 1 x 3C x 6 Sq. mm
Power & Control Cabling Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. Power cabling of XLPE insulated Aluminium conductor armoured cables of 1.1 KV Grade including cable end termination with brass compression glands & aluminium lugs etc as per specification. For Motor of 7.5 Kw 2 x 3C x 6 Sq. mm (Rate for Single Run)
For VRV ODU Unit (From Panel to Isolators near ODU) 4C x 16 Sq. mm Copper Conductor (Unarmoured) For VRF Unit
For VRV ODU Unit (From Panel to Isolators near ODU) 4C x 25 Sq. mm Copper Conductor (Unarmoured) For VRF Unit
HVAC Electric Work For Inline Fan / Propeller Fan (From MCB to Unit) 1 x 3C x 2.5 Sq. mm Copper Flexible Cable
For VRV Indoor Units (Cable shall be laid running in the PVC conduit through wall & ceiling along with the approved route. AC Contractor shall include the cost of chiselling & finishing the wall / ceiling. Cable from ODU electrical feeder panel shall run along with refrigerant piping on common cable tray) 3C x 2.5 Sq. mm Copper Conductor (PVC insulated, PVC sheathed flexible wire)
For VRV Indoor Units (Cable shall be laid running in the PVC conduit through wall & ceiling along with the approved route. AC Contractor shall include the cost of chiselling & finishing the wall / ceiling. Cable from ODU electrical feeder panel shall run along with refrigerant piping on common cable tray) 3C x 4 Sq. mm Copper Conductor (PVC insulated, PVC sheathed flexible wire)
For VRV Indoor Units (Cable shall be laid running in the PVC conduit through wall & ceiling along with the approved route. AC Contractor shall include the cost of chiselling & finishing the wall / ceiling. Cable from ODU electrical feeder panel shall run along with refrigerant piping on common cable tray) 3C x 6 Sq. mm Copper Conductor (PVC insulated, PVC sheathed flexible wire)
Transmission & Control Wiring For VRV System Providing & fixing of control cum trans-mission wiring of copper between indoor and outdoor unit in 20 mm PVC Conduit. AC Contractor shall include the cost of chiselling & finishing the wall / ceiling . 2C x 1.5 Sq mm (PVC insulated, PVC sheathed flexible wire)
Earthing Strip / Wires as per specs. Supply & laying of 8 SWG GI wire or in recess for loop earthing as required.
Earthing Strip / Wires as per specs. Supply & laying of 6 SWG GI wire or in recess for loop earthing as required.
Earthing Strip / Wires as per specs. Supply & laying of Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006.
Cable Tray Supplying and installing following size of perforated GI cable trays including bends. tee, reducers etc with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, suspenders etc as required. 100 mm wide x 50 mm depth x 1.6 mm thickness.
Cable Tray Supplying and installing following size of perforated GI cable trays including bends. tee, reducers etc with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, suspenders etc as required. 150 mm wide x 50 mm depth x 1.6 mm thickness.
Cable Tray Supplying and installing following size of perforated GI cable trays including bends. tee, reducers etc with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, suspenders etc as required. 300 mm wide x 50 mm depth x 1.6 mm thickness.
Cable Tray Supplying and installing following size of perforated GI cable trays including bends. tee, reducers etc with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, suspenders etc as required. 450 mm x 50 mm x 2.0 mm
RNR CONSTRUCTIONS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid