| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-AOC lowest Bidder | |
| 2 | L2₹29.4 L+₹4.2 L (16.6%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹29.7 L+₹4.4 L (17.5%)Rejected-Finance FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹30.6 L+₹5.3 L (21.2%)Rejected-Finance 173 RASTA PETH NIKHIL APARTMENT SHIRAL SETH CHOWK PUNE 411011 | PUNE | MAHARASHTRA | 411011 | L4 | Rejected-Finance High Rate | |
| 5 | L5₹31.9 L+₹6.6 L (26.2%)Rejected-Finance 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L5 | Rejected-Finance High Rate |
Tender Value
₹40.0 L
EMD Value
₹80,000
Closing Date
7 Mar 2025, 6:00 pmClosed
Garrison Engineer (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg Pin - 411001
8561A REPAIR/ REPLACEMENT OF INTERNAL ELECTRIC WIRING, FITTINGS, FIXTURES AND CONNECTED ELECTRICAL ITEMS AT OTM ACCN, ADM ACCN, TECH ACCN, NURSING COLLEGE, CERTAIN MESSES, E/M INSTALLATIONS AND OTHER AREA IN AFMC UNDER GE (CENTRAL) PUNE
2025_MES_696909_1
8561 (A) REPAIR/ REPLACEMENT OF INTERNAL ELECTRIC WIRING, FITTINGS, FIXTURES AND CONNECTED ELECT
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (Central) Pune
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune
₹80,000
Yes
20 Mar 2025
7 Feb 2025
10 Mar 2025
7 Feb 2025
7 Mar 2025
21 Feb 2025
Amount
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
M & L for concealed point wiring in wall and floor with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit including accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of suitable thickness with earth dolly and Bakelite laminated sheet ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:-
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane.
All as per item No 2 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
All as per item no 2 here-in -before but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/ side the switch board of light point in same vertical / Horzintal plane.
M & L for concealed point wiring in wall and floor with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit including accessories/ fittings such as junction boxes, bends, tee, elbow etc alongwith Modular sunken boxes including modular frame / cover plate suitable for mounting switches /sockets etc including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:-
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane.
All as per item No 3 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
All as per item no 3 here-in -before but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/ side the switch board of light point in same vertical / horizontal plane.
M & L for Surface point wiring on wall/ceilng with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia / PVC Casing & Caping not less then (20 x 12 ) mm including all accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of suitable thickness with earth dolly and Bakelite laminated sheet ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:-
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane.
All as per item No 4 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
All as per item No 4 here-in-before but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/ side the switch board of light point in same vertical / Horzintal plane.
M & L for Surface point wiring on wall / Ceiling with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia / PVC Casing & Caping not less then (20 x 12 ) mm including all accessories/ fittings such as junction boxes, bends, tee, elbow etc alongwith required size Modular sunken boxes including modular frame / cover plate suitable for mounting switches /sockets etc including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:-
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane.
All as per item No 5 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
All as per item No 5 here-in-before but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/ side the switch board of light point in same vertical / Horzintal plane.
Taking down old unserviceable/deteriorated point wiring aluminium/ copper (excluding PVC conduit/casing & caping & GI/PVC switch box any type and size) from existing place for light light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders sunken box, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
M&L for drawing the wire in existing conduit steel/PVC casing & caping any type and size ,complete with point wiring with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in old existing sunken terminal boxes pressed MS/GI/PVC boxes of any type and size for mounting switch, socket etc along with screw and cup washers with all accessories and making good to disturbed surface with cement mortar and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following: -
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane.
All as per item No 7 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
All as per item No 7 here-in-before but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/ side the switch board of light point in same vertical / Horzintal plane.
S & F as in repairs modular switch 6A SP one - way 230V white ivory finish complete all as specified
S & F as in repairs modular switch 16A SP one - way 230V white ivory finish complete all as specified
S & F as in repairs modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
S & F as in repairs modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
S & F as in repairs Modular type stepped electronic fan regulator all as specified & directed
M&L as replacement modular bell push,single pole,one way,6 Amp suitable for 1 module complete all as specified & directed
S & F as in repairs modular switch 6A SP Two- way 230V white ivory finish complete all as specified
M&L as in replacement modular white cover plate with frame and Flush box for 1 to 4 Module complete all as specified & directed
M&L as in replacement for modular white cover plate with frame and flush box for 6 to 12 module complete all as specified & directed
Supply & Fixing as in replacement medium step type fan regulator 80 Watt, 240 Volt AC, socket size, medium step" ISI marked complete all as specified and directed.
S&F as replacement switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed.
S&F as in replacement switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and as directed.
S&F as in replacement socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and as directed.
S&F as in replacement socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and as directed
S&F as in replacement bell push 5/6 Amps SP flush type complete all as specified and as directed.
S&F as in replacement Ding dong sound door call bell electric AC 240 volt, 50 Hz ding dong type including taking down unserviceable complete all as specified and as directed.
S&F as in replacement Angle lamp /batten holder fixed on wall /ceiling all as approved and directed by Engineer-in-charge.
S&F as in replacement ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed.
Supply and fixing as in repairs Metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps complete all as specified and directed by EIC.
S&F Ceiling Fan AC single phase 230 volts for size 1200 mm sweep, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV fan any type and size and deposited it in MES Store yard or as directed by EIC.
M & L as in repairs for Sub main wiring complete with two single core 2.5 sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 2.5 sqmm in and including PVC conduit/Casing caping incl accessories complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 2.5 Sqmm conductor and one run of PVC conduit/casing caping shall be measured as one unit length.)
M & L as in repairs Sub main wiring complete with two single core 4 sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 4 sqmm in and including PVC conduit /casing caping incl accessories complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 4 Sqmm conductor and one run of PVC conduit /casing caping shall be measured as one unit length.)
M & L as in repairs Sub main wiring complete with Two single core 6 sqmm and one core of 6 sqmm earth wire,1100volts FRLS grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor in and including PVC Conduit /casing caping including accessaries complete. (Note:- Making good of disturbed surfaces will be done by contractor without any claims.(ii) 3 runs of 6 Sqmm conductor and one run of PVC conduig/casing caping shall be measured as one unit length.)
supply and fixing as in replacement of MCCB 63 Amps TP/FP16 KA with fixed thermal magnetic release frame F2 optim 1.0 , 4pole all as specified and directed.
Supply and fix as in replacement of 3 Pin Plug Top 16A, White/Black 240V|3 Pin Top complete all as spd and directed.
M & L as in repairs Sub main wiring complete with four single core 10 sqmm and one core of 10 sqmm earth wire,1100volts FRLS grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor in and including PVC Conduit/casing caping including accessaries complete. (Note:- Making good of disturbed surfaces will be done by contractor without any claims.(ii) 5 runs of 10 Sqmm conductor and one run of PVC Conduit/casing caping shall be measured as one unit length.)
Supplied and fixing in replacement PVC conduit by Non Metallic Rigid PVC conduit, ISI Marked, medium grade of size 25 mm dia including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete all as specified and directed.
Supply and fix as in repairs LED Tube light fittings 18/20 W White/warm white Surface and wall mounted LED batten, 6500K colour temparature. Soft & uniform light, instant start electronic driver efficiency >85%, complete including all accessories internally pre-wired in and including connecting up with twisted flexible copper conductor cable of suitable size from ceiling rose to connector complete all as specified and directed.
S & F in replacement of LED light fittings 2'x2' of capacity 35/36 watts White/warm white LED surface/reccess environmental friendly, new genereation, aesthetically designed, ultra modern recess mounting luminaire with high brightness glare free soft illumination, white powder coated housing with LEDs, seamless front frame with flat white acrylic cover, 230 volts with all accessories internally pre wired and necessary mounting arrangements complete all as specified. .
S & F in replacement of round recessed mounted with in-built driver, power factor > .9 operating voltage 230 V, surface mounting in round shape 9/12W LED downlighter of white/neutral white/ warm white color temperature , of size as per site requirement etc along with 3 core prewired and all accessories complete all as specified and directed.
S & F in replacement of round recessed mounted with in-built driver, power factor > .9 operating voltage 230 V, surface mounting in round shape 15/18W LED downlighter of white/neutral white/ warm white color temperature, of size as per site requirement etc. along with 3 core prewired and all accessories complete all as specified and directed.
S&F as in repairs LED street/ Building light with pressure die-cast housing along with prismatic polycarbonate diffuser and LEDs with secondary optics and IP 65 protection 30 watt complete with all accessories and wall mounting bracket of suitable size including clamps, nut bolts etc. prewired 3 core flexible wire complete all as specified as directed.
S&F in replacement of LED light fitting surface and wall mounted LED batten with PVC housing & integrated electronic sensor complete in all respect of 10W cap complete all as specified and as directed
S&F in replacement of LED bulk head light fitting surface and wall mounted LED batten with complete in all respect and as per sample approved by EIC of 10W cap complete all as specified and as directed
Supply & fix as in repairs Electric Storage water heater of capacity 25 Ltr , 230 V energy efficient complete all as specified and directed by Engineer-in-charge.
Man and material for removing of Stage lighting like COB/RGBW/Spot/Beam/flood light along with its connecting cable from a hight upto 12 Mtr by removing is all electricial /data cable connection along with connected accessories from light and its digital lighting console (management system) along with its power cable safely and handed it over to the AGE E/M store yard.
Material and labour for Installation serviceable Stage lighting like COB/RGBW/Spot/Beam/flood light at a hight upto 12 Mtr. Securing necessary equipment for safely reaching heights of up to 12 meters, such as scaffolding or ladders deemed to be included in the job duly ensuring proper positioning and alignment of the light fitting, providing safe and secure electrical connections for each light fixture incl making any necessary extensions to the power cables and perform any cutting or taping work required. Connecting light to the digital lighting management system (console) as per the user's requirements. Ensuring the entire setup is safe, functional, and in line with the provided specifications. The entire job will be supervised by an authorized stage lighting technician, Each installed light will be provided with suitable ADDRESS to connect with spliter and console any type and make all as spd and directed by Engineer-in-Charge.
M&L for the replacement of the existing GI structure used for stage lighting of any type and size. The job involves dismantling the current structure and rearranging it using GI pipes, clamps, nuts, bolts, washers, and welding as required. The new structure will be fastened securely and grouted properly to ensure it can support the weight of the complete lighting system. The structure will be designed to hold the weight of approximately 35 or more stage lights like COB, RGBW, spotlights, beam lights, and floodlights etc. The job includes surface preparation, application of primer, and two coats of paint to protect the structure. Note: All work will be carried out as per specifications and instructions provided by the Engineer in Charge (EIC).
Removal and Replacement of Ceiling Lighting any type and size by providing labor and material from an existing ceiling lighting of any type and kind, including its connecting accessories, from a height of up to 12 meters. This includes disconnecting all electrical connections. Supply and install new downlights of any type and size in the existing false ceiling, ensuring proper connections and functionality as before. Securing the necessary equipment, such as scaffolding or ladders, for safely reaching heights up to 12 meters is included in the job. The contractor is responsible for the safety of all personnel and materials during the execution of the job. Any new or serviceable lights will be provided under their respective columns all as spd and directed by the Engineer in Charge (EIC).
Comprehensive maintenance of Stage Lighting Console (DMX 512 Compatible) by providing labor and materials for the upgradation, resetting, and reprogramming of a DMX 512 compatible stage lighting console. This includes configuring and integrating the system with a Digital DMX Splitter (HQ), ensuring compatibility and seamless communication between lighting fixtures. The job also involves Full integration of the DMX 512 console with the digital DMX splitter, the stage lighting console will be reprogrammed to ensure control of all lighting elements, any necessary firmware updates, software calibration, and system optimization to enhance performance. Note: The extra set of program backup will be provided. All work will be carried out according to the technical specifications and as directed by the Engineer in Charge (EIC).
S&F Exhaust fan AC single phase 230 volts for size 300 mm sweep, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed inluding removing and dismentaling of old UNSV ex fan any type and size and deposited it in MES Store yard or as directed by EIC.
S&F Exhaust fan AC single phase 230 volts for size 200 mm sweep Plastic body along with louvers, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV ex fan any type and size and deposited it in MES Store yard or as directed by EIC.
S&F Exhaust fan AC single phase 230 volts for size 250 mm sweep plastic body along with louvers, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV ex fan any type and size and deposited it in MES Store yard or as directed by EIC.
S&F as in repairs vertical 4 way TPN double door, recess mounted/wall mounted, MCCB as incomer and outgoing MCB SP/TP is 3 pole V-Tec of 100A rating & 16KA breaking capacity, MCCB is pre-fitted at factory & including price of MCCB, all as specified. (Note : Empty space shall be covered by blanking plate and connect with lugs without any extra cost )
S&F as in repairs MCB TPN DB 4 way double door with 200 amps rated busbar 415 V, all as specified.
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way complete all as specified and directed.
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12 way complete all as specified and directed.
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way complete all as specified and directed.
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 2 way complete all as specified and directed.
supply and fixing as in replacement of MCCB 100 Amps TP/FP16 KA with fixed thermal magnetic release frame F2 optim 1.0 , 4pole all as specified and directed.
Supply & Fixing as in replacement MCB SPN, 5 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,complete all as specified and directed.
Supply & Fixing as in replacement MCB SP, 06 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked complete all as specified and directed.
Supply and fixing as in replacement of MCB TPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and complete all as specified and directed.
Supply and fixing as in replacement of MCB Tripple pole of rated capacity 40/63 amps, 415 volts breaking capacity 10 KA, C-curve complete all as specified.
Material and labour to perform core drilling on brick/masonry walls with a thickness of up to 18 inches, drilling shall crate holes with a diameter ranging from 2 to 4 inches, using suitable machinery and equipment. The contractor shall provide all necessary materials, labour, and eqpt reqd to perform the work. The contractor shall ensure that the drilling prices is executed without damaging the surrounding structure, any scaffolding, ladders, or additional support structures necessary to perform the job shall be arranged by the contractor under the job complete all as spd and directed by the EIC.
M & L as in replacement for earthing with galvanised steel earth plate electrode 60cmx60cmx 6.3 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete (NOTE:-GI earth wire and protection pipe beyond 7.5m will be measured and paid separately)
M & L in replacement for earthing with GI Electrode 3 Mtr long consist of GI pipe outer dia 76mm and GI pipe inner dia 32mm , inner space should be compacted with dry chemical compound for enhancing conductivity all including boring installation, transportaion, concrete pit including excavation and earth work in any type of soil and sufficient quantity of ground enhancing backfil compound testing of soil condition, PVC pit cover and GI strip 32 x 6mm up to 7.5 Mtrs long etc and testing on completion etc complete all as specified and directed.
S & F as in repairs service connection with twin core 10 Sqmm 240 volt heavy duty un armured PVC insulated solid aluminium conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connection in replacement of old unseriveable conductor cable complete.
S & F as in repairs service connection with twin core 6 Sqmm 240 volt heavy duty un armured PVC insulated solid aluminium conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connectionin replacement of old unseriveable conductor cable complete.
S&F in replacement of old sketch fitting/any type by decorative wall mounted LED lamp (white/ warm) complete all as specified and directed as per sample approved
Supply, installation, testing and commissioning as in replacement of exterior RGBW Linear LED Wall Washer luminaire suitable for facade lighting with extruded aluminium housing, powder coated finish, clear toughened glass Appx System wattage 40 Watt with system Lumileds output should be more than 3000 Lm with all LEDs on. Luminaire shall be capable of producing dynamic color changing light, the light fixture should be programmable using DMX512 protocol/ ethernet based control. Luminaire should be complete with dedicated Lens made offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement including surface mount base with constant locking hinges for simple position control from various angles without special tools. DMX enabler circuit should be inside the luminaire only. The rated voltage of the Luminaire should be 230 VAC. Luminaire shall be offered with a BIS approved potted driver of IP-66/67 rating made of extruded aluminium to make it more thermal efficient, LED driver should have operating input voltage range: 90-305 VAC, PF > 0.9, all as per present sample complete all as spd and directed by EIC. Note (i) The product should be BIS approved (ii) Cost of scafolding/ladders/T&P required for fixing of wiring, light fittings, MS brackets, pipes, MS fabrication work etc at site for execution of complete work shall be deemed to be included in the quoted rates. Make: Havells, or equivelent make in Philips/ Jaquar
Comprehensive maintenance of Fasad Lighting system consisting of RGBW liner LED wall washer luminaire , M15 female connector, M15, extension connector, CS junction box 3 way, DMX controller system expandable from 2 to 4 DMX 512 universes by providing technician labour and routine maintenance materials for the upgradation, resetting, and reprogramming of a DMX 512 compatible Facade lighting . The job also involves Full integration of the DMX 512 console with all the Fasad lights and its connected assessories. All work will be carried out according to the technical specifications and as directed by the Engineer in Charge (EIC).
S&F in replacement of decorative wall mounted LED lamp (white/ warm) for main gate complete all as specified and directed as per sample approved
Note for all above :- (a) Contractor will daily detail minimum one qualified electrician assisted by a helper at complaint cell. They will carry a ladder and necessary electrical tools to check and troubleshoot electrical complaints for various location of AFMC. (b) Complaint related to no lights, replacing of switches, sockets, , replacing burnt MCB, short circuit, voltage fluctuation due to internal wiring, repair to faulty earthing etc will be attended withing 8 hour of raising complaint. (c) The complaint can be registered Telephonic/complaint slip, WhatsApp and any other mode of communication. (d) Sufficient store shall be procured by the contractor for day to day issue to complaint.
PURVA ELECTRICALS AND ENGINEERS (BID ID -3250614)
GANGA ENTERPRISES (BID ID -3251884)
M/S - SUJIT ELECTRICALS (BID ID -3251683)
SBS Enterprises (BID ID -3256447)
M/s Asrani and sons (BID ID -3252114)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .