Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹49.2 L+₹3.1 L (6.79%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹49.3 L+₹3.2 L (6.89%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹50.9 L+₹4.8 L (10.5%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹51.6 L+₹5.5 L (12.0%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
29 Jun 2021, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR MAINT OF CEILING FAN EXHAUST FAN WALL MOUNTED FAN AND MISC EM WORKS AT SI LINES AND CLEANING OF WATER TANK OHT UG SEMI UG AND ALLIED WORKS AT BAIRAGARH UNDER GE BHOPAL
2021_MES_450351_1
8789/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
BHOPAL
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹99,000
Yes
30 Jul 2021
10 Jun 2021
1 Jul 2021
10 Jun 2021
29 Jun 2021
24 Jun 2021
Amount
Note: This work comprises of (i) Repair/maint of ceiling fan, exhaust fan, wall mounted fan and Misc E/M works at SI Lines and (ii) Cleaning of water tank (OHT, UG, Semi UG) and allied works at Bairagarh. The qty of individual part shall not vary beyond deviation limit specified in tender. NOTE for Repair/maint of ceiling fan, exhaust fan, wall mounted fan and Misc E/M works: - (i) The quoted rate deems to include for all minor expenses required for making the complaint functional. (ii) Repairing/ rewinding of ceilling fan/ exhaust fan shall be carried out in the AGE E/M Bairagarh subdivision in present of concern JE E/M. (iii) Space/room will be provided by AGE E/M in the E/M yard for carring out repair work. (iv) Contractor staff will collect defective fans from concern JE E/M, check the fans after opening it, and intimate the defects in the fan to JE E/M before carring out the repairs. (v) The bearing of fan should be of NBC/SKF/FAG make only. No other make will be accepted.
Dismantling of ceiling fans AC single phase 230 volts of sizes 1200mm/1400mm (collected from MES fan store ) any make / model except old vintage, dismantling its stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish, cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws etc as required and reassembling and depositing the repaired fan to MES fan store after testing complete all as specified and directed.
All as per BOQ serial item No.1.10 above but exhaust fan, 400/450 mm sweep, AC single phase, 230/240 volts.
All as per BOQ serial item No.1.10 above but exhaust fan, 300/380 mm sweep, AC single phase, 230/240 volts.
All as per BOQ serial item No.1.10 above but exhaust fan, 230/250 mm sweep, AC single phase, 230/240 volts.
All as per BOQ serial item No.1.10 above but wall / pedestal fan, of any sweep and capacity
S&F in replacement condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed.
S&F in replacement upper set of clips for down rod with rubber Bush (Garari) including set of nut bolts and washer, pin complete all as specified and directed.
S&F in replacement rubber bush (Garari) for mounting at upper side of down rod clip complete all as specified and directed
S&F in replacement gun metal bush self lubricated, any size, suitable for ceiling and wall fans complete all as specified and directed
S&F in replacement flexible copper conductor stranded 1100 Volt PVC insulated cable twin core twisted 23/0.0076 size complete all as specified and directed.
S&F in replacement Fan condenser 2.5 mfd, 230 volts complete all as specified and directed. [Make: Epcos/Tibcon as approved by GE]
S&F in replacement Fan condenser 3.15 mfd, 230 volts complete all as specified and directed. [Make: Epcos/Tibcon as approved by GE]
S&F in replacement Fan condenser 4.0 mfd, 230 volts complete all as specified and directed. [Make: Epcos/Tibcon as approved by GE]
Supply only the following items for fixing against defective parts of fan taking down under item No 1 here in before complete all as specified and directed.
Bearing No 6201'ZZ' [Make : SKF/NBC/FAG as approved by GE]
Bearing No 6202'ZZ' [Make : SKF/NBC/FAG as approved by GE]
Bearing No 6203'ZZ' [Make : SKF/NBC/FAG as approved by GE]
Bearing No 6204'ZZ' [Make : SKF/NBC/FAG as approved by GE]
Taking down ceiling / wall fan from fan hook and disconnection from ceiling rose, dismantling of fan parts i e. down rod and connector/condenser, nut bolts, split pins, rubber bush (garari), condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re - fitting / reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
Taking down exhaust fan and disconnection from ceiling rose, dismantling of fan parts i e. connector/ condenser, nut bolts, condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re - fitting / reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
S&F in replacement down rod for ceiling fans duly painted with synthetic enameled paint 300 mm long19 mm outer dia with holes on both ends of the rod for connection wire replacement complete all as specified and directed.
S&F in replacement down rod for ceiling fans duly painted with synthetic enameled paint 600 mm long19 mm outer dia with holes on both ends of the rod for connection wire replacement complete all as specified and directed.
S&F in replacement Exhaust fan blade duly powder coated suitable for 450 mm/380mm sweep as per existing complete all as directed .
S&F in replacement Exhaust fan blade duly powder coated suitable for 300 mm/230mm sweep as per existing complete all as directed .
S&F in repairs blade assembly of celling fan of 1200 mm sweep (set of three) of make, colour and pattern as per existing complete all as specified and directed.
S&F in repairs blade assembly of celling fan of 1400 mm sweep (set of three) of make, colour and pattern as per existing complete all as specified and directed.
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 450 mm /380 mm sweep exhaust fans complete all as specified and directed.
S&F in repairs top and bottom canopy of ceiling fan ( any sweep) of make , colour and pattern as per existing model all as specified and directed
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 230 mm /300 mm sweep exhaust fans complete all as specified and directed.
M&L for painting of following Item with two coats of DUCO paint (ISI grade) white using spray machine.Spray painting including cleaning, washing and preparation of old painted surfaces including writing MES Nos in all ceiling and Exhaust fan complete all as specified and directed. Note:- Taking down and fixing of fan will be measured under item No. 1 here-in-before.
Ceiling fan upto 1200/1400 mm sweep complete.
Exhaust fan upto 280/300/380/450 mm sweep with smoke grey paint
S&F ceiling fan regulator electronic step type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/ LEGRAND/ HAVELLS as approved by GE]
Dismantling of cabin fan of any sweep and overhauling by means of cleaning of stator, oiling & greasing including replacement of nut and bolt, etc and reassembling, re-fixing and testing the fan complete all as specification and directed.
Removing unserviceable fan / bearing shaft (of any type & fan) and shaft welding broken area and threading in lathe machine at appropriate size and refixing in ceiling fan, any type complete all as specified and directed.
Taking down unservicable sub main wiring including service connections, of any size and any description including conduit pipe and making good disturbed surface of walls/ ceiling to match with existing surface after necessary rewiring complete all as specified and directed .
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with four single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
Taking down carefully existing point wiring (any type viz. aluminum or copper) with wooden batten/surface PVC conduit (with its fittings)/PVC casing-capping or any other type for light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in & including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No.39.00 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No.39.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No.39.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way, 5/6 Amps, 230 volt AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Socket outlet multipurpose having provision for 3 pin, 5 Amp and 2 pin, 5 Amp, piano flush type, 230 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch socket combination, multipurpose, 6 pin, 5-15 Amp, flush type, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Dismantling geyser of 25 ltrs capacity and of any description, M&L for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet, overflow, geyser element, thermostat, U assembly etc. with brush & cleaning rods and using and circulating concentrated de-scaling solution mixed with water in suitable proportion till the complete deposits/scale is removed and approved by the Engineer-in-Charge, brazing for stopping the leakage of copper inner tank/ gas welding for stopping the leakage of inner steel tanks, fixing the serviceable parts in position, setting insulation properly as required, reassembling the complete geyser after cleaning, repairing and painting, fixing & installation of the geyser in position and its testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. NOTE:- (i) De-scaling chemical shall be concentrated HCL of make as approved by GE. (ii) Painting of Geysers shall be on requirement basis and shall be measured and paid for separately under appropriate item of BOQ (iv) Old disturbed insulation shall be made good by the contractor with using old retrieved glass wool and additional quantity of glass wool for insulation, if any required, is deemed to be included in the quoted unit rate. (v) Spares as required shall be measured and paid seperately.
All as per BOQ Sl No. 46.00 above but geyser of capacity 50 Ltrs .complete all as specified and directed.
S&F 1.5 KW capacity Heating Element, Push/ Screw type with ‘O’ ring including making electrical connection complete all as specified and directed. [Make: Bajaj/ Usha /Theta or as recommanded by manufacturer or equivalent as approved by GE.]
S&F 2.0 KW capacity Heating Element, Push/ Screw type with ‘O’ ring including making electrical connection complete all as specified and directed. [Bajaj/ Usha /Theta or as recommanded by manufacturer or equivalent as approved by GE.]
S&F in replacement Geyser assembly suitable for 25 ltr capacity, ISI marked complete all as specified & directed.
S&F in replacement Geyser assembly suitable for 50 ltr capacity, ISI marked complete all as specified & directed.
S&F in replacement thermostat suitable for 25/50 Ltr Geyser ISI marked with setting range 30 C to 80 C suitable for 230 volts AC electric supply complete all as specified & directed. [Make : Danfoss / Ranco / Indfoss or as recommanded by manufacturer or equivalent as approved by GE.]
S&F in replacement inner tank made of stainless steel suitable for 25 Ltr geyser complete all as specified & directed.
S&F in replacement inner tank made of stainless steel suitable for 50 Ltr geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement Indicating lamp (set of two) 230 volts 50 HZ AC suitable for geyser any type (round, square or rectangular type) any capacity complete all as specified and as directed.
M&L for painting of following Item with two coats of DUCO paint (ISI grade) white using spray machine.Spray painting including cleaning, washing and preparation of old painted surfaces including writing MES Nos complete all as specified and directed.
Geyser 25 ltr capacity
Geyser 50 ltr capacity
S&F in replacement single pole and neutral enclosure with two pin and earth, plug and socket, suitable for single phase 240 V,complete with and including one single pole MCB of capacity 20 amps having `C` charactristic, breaking capacity 10 KA, including industial plug top complete all as specified and as directed. [Make : Legrand cat part No. 607841 or equivelent in Schinder/ L&T as approved by GE.]
S&F in replacemnt PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed. [MAKE:-PRAYAG/ POLYTUFF as approved by GE]
S&F in replacemnt PVC connection Nylon braided, heavy duty, 450mm long including rubber washers (suitable for hot water) complete all as specified & directed.
S&F in replacement pressure release valve suitable for 25/50 Ltr capacity geyser complete all as specified & directed.
S&F in replacement Steel water tubes, medium grade, ISI marked, galvanised, 15 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. [MAKE: TATA/ SURYA/ JINDAL/ PRAKASH as approved by GE]
S&F in replacement Steel water tubes, medium grade, ISI marked, galvanised, 20 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. [MAKE: TATA/ SURYA/ JINDAL/ PRAKASH as approved by GE]
S&F in replacement GI socket 15mm dia ISI marked complete all as specified & directed.
S&F in replacement GI union 15mm dia ISI marked complete all as specified & directed.
S&F in replacement GI Elbow 15mm dia ISI marked complete all as specified & directed.
S&F in replacement GI Nipple 15mm dia 100 mm long ISI marked complete all as specified & directed.
S&F in replacement GI Tee equal15x15x15mm dia ISI marked complete all as specified & directed.
S&F in replacement GI Tee 20x20x15mm dia ISI marked complete all as specified & directed.
S&F in replacement GI socket reducer 20 x 15mm ISI marked complete all as specified and directed.
S&F in replacement stop valves ISI marked, 15mm dia cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends fancy type, chromium plated for iron pipe or for unions etc complete all as specified and directed. [Make: Prayag / PRIMA / Jainko as approved by GE]
S&F in replacement Bib tap, ISI marked, 15mm dia cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends fancy type, chromium plated for iron pipe or for unions etc complete all as specified and directed. [Make: Prayag / PRIMA / Jainko as approved by GE]
S&F in replacement PVC insulated multistranded copper conductor, 3 core of size 2.5 Sqmm, 1100 volts grade complete all as specified & directed. [Make:-Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE]
S&F in repairs LED ultra slim decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2, luminaire 36 watt with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core complete all as specified & directed. [Make :- Havells Cat No VENUSNEOHE2X2R36WLED840PIRSENSOR or Equivalent in Crompton/Syska/ Bajaj/Wipro
S&F in repairs LED Sleek round recess mounting LED ceiling light 1 x 1 decorative type aluminium casted edge ceiling light, recess mounting LED, luminaire 18 watt with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core complete all as specified & directed. [Make :- Havells Cat No PLUTOSURFACE1x1PLS15WLED840S or Equivalent in Crompton/Syska/ Bajaj/Wipro
S&F in repairs Coral post top lantern fitting 25 Watt ( for Gate light) , energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with complete accessories all as specified and directed by Engineer in charge. Make: Havells , Cat NO: CORALPT25WLED757PSYMTOPC or equivalent in Bajaj.
S&F in repairs LED tube light complete fitting , surface mounted luminanaires , 1x 20 watt, 240V, decorative ultra slimround/square profile LED lighting fixture with extruded polycarbonate body, environmental friendly , energy efficient ready to use pack with bipin holders, LED Lamps ,connector block, etc complete with all accessories internally prewired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed. Make : Havells Cat No: LHEXBLP7PN1W020 Equivalent in Crompton/Syska/ Bajaj/Wipro
Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium conductor of size 10 sqmm, 2 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc complete all as specified and directed. [MAKE:- POLYCAB /HAVELLS INDIA LTD/V-MARC as approved by GE]
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed. at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. [Note:-Compacted/punned thickness shall be measured & paid]
Supplying and laying sub class 'B' bricks (modular) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed
CLEANING OF WATER TANKS (OHT, UG, SEMI-UG) INCLUDING ALLIED WORKS AT BAIRAGARH
M&L for cleanng, disinfection & carefully washing out settled mud, alum, flocculant, etc from sedimentation tank (2 x 1.50 lakh & 1 x 1.25 lakh gallon capacity) of size 19.50m x 9.75m x 4.35m depth internal size of each tank having 2 Nos buffer walls of size 15.15m x 0.15m x 4.0m height in each tank; drainning out complete waste water from tank mannually and by mechanical arrangments; cleaning of bottom, all internal side walls, channel using brooms, wiper or nylon brush, sludge removal , high pressure cleaning, anti bactrial spray, UV radiation including scrapping out and applying one coat of super quality lime wash on outer stone wall surface of sedimentation tank and wirting the date of cleaning on the wall of tank on blue base with white colour; including cleaning of the surrounding area of the tank upto a distance of 3 mtrs from the outer edge of tank by cutting of grass, digging out roots, filling holes with earth, levelling of ground and removing waste material to a distance not exceeding 50m complete all as specified and directed. Note:- 3 tanks shall be measured as one job for payment purpose.
M&L for cleanng, disinfection & carefully washing out settled mud, alum, flocculant, etc from FLOCCULATOR TANK of 15.16 mtr dia & 4.5 mtr depth including external channels, chambers and outlet, etc; drainning out complete waste water from tank mannually and by mechanical arrangments; cleaning of bottom, all internal side walls, channel using brooms, wiper or nylon brush, sludge removal , high pressure cleaning, anti bactrial spray, UV radiation including scrapping out and applying one coat of super quality lime wash on outer stone wall surface of sedimentation tank and wirting the date of cleaning on the wall of tank on blue base with white colour; including cleaning of the surrounding area of the tank upto a distance of 3 mtrs from the outer edge of tank by cutting of grass, digging out roots, filling holes with earth, levelling of ground and removing waste material to a distance not exceeding 50m complete all as specified and directed.
All as per BOQ serial item No. 91.00 above but flocculator tank (0.5 lakh gallon capacity) including lime & Alum mixing chambers 03 Nos, intake chamber complete all as specified and directed.
Cleaning & disinfection of semi UG sump 1 Lakh gallon capacity mannually and by mechanical arrangments at main filter pump house at Bairagarh complete all as specified and directed. NOTE:- Quoted rates is deemed to include for:- (i) Cleaning inside walls, floor, dome, ceiling with wire steel brush removing pile/sludge/ silt/ alge and other forgein material, sludge removal, high pressure cleaning, anti bactrial spray, UV radiation and washout with clear water all as specified and upto the satisfaction of EIC . (ii) Applying one coat of super quality lime wash on inner wall surface after cleaning of tank (iii) Cleaning the surrounding area of the reservoir to a distance of 3 mtrs all around its circumference including cutting of grass, digging out roots, filling holes, levelling of ground and removing waste material to a distance not exceeding 50m complete all as specified and directed.
All as per BOQ serial item No.93.00 above but for clear water semi UG sump 1.5 lakh gallon capacity at main filter pump house at Bairagarh complete all as specified and directed.
All as per BOQ serial item No. 93.00 above but for clear warer semi UG sump 3 lakh gallon capacity at main filter pump house at Bairagarh complete all as specified and directed.
All as per BOQ serial item No. 93.00 above but for clear water semi UG sump 2 lakh gallon capacity at New MH pump house complete all as specified and directed.
All as per BOQ serial item No. 93.00 above but for sump .75 lakh gallon capacity at tank No 2 at 1 TB area complete all as specified and directed.
All as per BOQ serial item No. 93.00 above but for semi UG sump 6.0m x 6.0m x 2.6m at MH pump house complete all as specified and directed.
All as per BOQ serial item No. 93.00 above but for semi UG sump 6.0m x 6.0m x 3m at TRS pump house complete all as specified and directed.
All as per BOQ serial item No. 93.00 above but for semi UG sump 6.0m x 6.0m x 2.6m at MH pump house complete all as specified and directed.
All as per BOQ serial item No. 93.00 above but for RCC OH tank of 1 Lakh gallon capacity up to 18 mtr staging at 3 EME centre area complete all as specified and directed.
All as per BOQ serial item No. 93.00 above but for RCC OH tank of 17000 gallon capacity on 18m staging at TRS complete all as specified and directed.
All as per BOQ serial item No. 93.00 above but RCC OH tank of 0.5 lakh gallon capacity up to 16.0m staging MAP Offrs Qtr at 3 EME centre area complete all as specified and directed.
All as per BOQ serial item No. 93.00 above but RCC OH tank of 0.5 lakh gallon capacity up to 16.0m staging MAP JCOs/ORs Qtr at 3 EME centre area complete all as specified and directed.
All as per BOQ serial item No. 93.00 above but RCC OH tank of 1.0 lakh gallon capacity up to 16.0m staging at New MH accn complete all as specified and directed.
All as per BOQ serial item No. 93.00 above but for 3 x 10000 Ltr HDPVC tank at key personnel qtrs complete all as specified and directed. Note:- 3 x 10000 ltr HDPVC tanks shall be measured as one job for payment purpose.
M&L for cutting/treeming grass, buses, and cleaning complete inside area of Main filter pump house and 2 meter outside fencing including cleaning of fencing from grass /treeming carefully taking proper precautions of electric cables, pipe lines, etc including using own T&P reqd at site, etc complete all as specifed and directed. (Approx area of pump house 500m x 150m).
M&L for cleaning/taking out sludge, soil, stones, grass, etc from open drain (1 feet to 3 feet in width and 1 feet to 4 feet in depth and approx 600 m in length) and spreading /leveling outside 10 meter from drain with & including applying one coat of white wash on walls at main filter pump house complete all as specified and directed.
M&Lcleanng, disinfection for washing /cleaning of rapid sand gravity filter (02 Nos) by mannually and by mechanical arrangments;by scrapping out upper layer (appx 10 cm) mannually and by mechanical arrangmentsfor removing forigen material/mud, etc and cleaning side wall / tiles portion,mannually and cleaning of bottom, all internal side walls, channel using brooms, wiper or nylon brush , sludge removal, high pressure cleaning, anti bactrial spray, UV radiation including flushing mud water by using valve & compressor; and laying fresh sand to makeup level of sand in filter bed up to required level (which decreases due to daily backwashing of filter bed) complete all as specified and directed.
M&L for cleaning/taking out sludge, soil, stones, grass, etc from open jack well (3.5 mtr dia, 4 mtr depth) tank mannually and by mechanical arrangments; and spreading /leveling outside 10 meter from well with & including applying one coat of white wash on walls at Raw water pump house complete all as specified and directed. Note:- 5 Nos. of jack wells of Raw Water PH shall be measured as one job for payment purpose.
Deduct schedule of credit (calculation will be done off line) Rs.57860.00
M/s VIKAS TRADERS
ROYAL CONSTRUCTION
S Balwinder Singh
M/S AJAY JAIN
M/S Shanti Enterprises
SUNIL ENTERPRISE
MODI CORPORATION
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .