| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L1 | Accepted-AOC Being lowest bid | |
| 2 | L2₹17.8 L+₹1.8 L (11.3%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹19.1 L+₹3.1 L (19.2%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹20.6 L+₹4.6 L (28.8%)Rejected-Finance PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹22.7 L+₹6.7 L (41.9%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
28 Sept 2024, 6:00 pmClosed
GE (North) Udhampur
GE (North) Udhampur, C/O 56 APO, PIN-182101
REPAIR TO INTERNAL E/M WORKS AND CONNECTED ITEMS AT JNE AND ADJOINING AREA UNDER GE (NORTH) UDHAMPUR
2024_MES_657113_2
GE/U(N)-37/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (North) Udhampur
As per NIT
6 documents required · 6 mandatory
₹500
GE North Udhampur
₹70,000
Yes
22 Nov 2024
6 Sept 2024
30 Sept 2024
6 Sept 2024
28 Sept 2024
15 Sept 2024
7 Sept 2024 - 10 Sept 2024
Amount
Taking down carefully the existing copper / aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling rose, regulators, bell etc by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good to disturb surface of walls, floors etc., complete all as specified and directed by Engr-in-charge. Note :- Old dismantled wiring and accessories (other than reuse) will be contractors property and credit will be charged against schedule of credit.
Taking down carefully by unscrewing from boards / outlet boxes fittings and fixture such as LED bulk head fitting, LED tube light fitting etc. for re use at site or carrying to the store (serviceable fitting shall be reuse), complete all as specified and directed by Engr-in-Charge.
Taking down old serviceable / unserviceable MCB DB any type/ size etc after disconnecting (serviceable DBs /MCBs shall be reuse), complete all as specified and directed by Engr-in-Charge.
M&L for point wiring for One light/fan/bell point controlled by one one way switch 5 Amp with 1.5 Sqmm single core multi standard copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn into and including concealed PVC rigid conduit of not less than 20mm dia and1.5mm wall thickness ISI marked terminated into annealed steel terminal boxes flush to surface including 3.00 mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc, complete all as specified and directed by the Engr-in-charge.
M&L for point wiring with 1.5 Sq. mm PVC Insulated unsheathed FRLS multi stranded copper conductor, medium grade ISI marked drawn into and including PVC concealed conduit with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drwan in to and including surface PVC rigid non metallic conduit for one ceiling fan point controlled by one switch with and also including 1.5 sqmm continuous earth wire connected to common earth dolly complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 4 here-in-above but for one bell / buzzer point controlled by one push button on the same board with other switch or independent one push button bell switch.
All as per Srl item Srl No. 4 here-in-before but for 3 pin socket outlet 5 Amp on same board, complete all as specified and directed by Engr-in-charge.
All as per Srl item No. 4 here-in-above but for one 5 Amps socket outlet on independent board.
All as per Srl item No. 4 here-in-above but wire size 2.5 Sqmm to controlled the 3 pin 5/15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLS 1100 volts grade un sheathed single core stranded copper conductor cable of size 2.5 Sqmm.
All as per Srl item No. 4 above but controle by 2 Nos.of two way switch.
M&L Point wiring with multi stranded copper conductor cable, PVC insulated and unsheathed (FRLS) size 1.5 sqmm drawn in and incl PVC casing and capping /PVC conduit with fixing accessories, to be fixed on wooden gutties or plastic rawal plug, for one light /fan/controlled by one switch with thickness not less than 1.25mm annealed steel boxes concealed on wall with and including 3mm thick laminated back lite sheet, complete all as directed by Engineer-in-charge.
All as per Srl item No. 11 here-in-above but for two way point wiring.
All as per Srl item No. 11 here-in-above but for one 3/5 pin socket 5 Amp on same board with cable1.5 sqmm size.
All as per Srl item No. 11 here-in-above but for one 3/5 pin socket 5 Amp on independent board with cable1.5 sqmm size.
All as per Srl item No. 11 here-in-above but for 3/5 pins socket outlet 15 Amps independent with 2.5 sqmm incl continuous earthing with multi stranded copper conductor PVC insulated unsheathed size 2.5 Sqmm, complete all as specified and directed.
All as per Srl item No. 11 here-in-above but for bell / buzzer on independent board controlled by one push button bell switch.
S&F in replacement switch piano flush type single pole 5 Amps one way, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket outlet two in one, 3/5 Pin piano type 5 Amp flush type, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch socket combination piano type 5 pin 5 Amps flush type, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch socket combination piano type 6 pin 16 Amps flush type, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch piano flush type for bell Push 5 Amps, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch piano flush type single pole two way 5 Amps, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch piano type single pole 16/20 Amps One way, complete all as specified and directed by Engineer-in-Charge.
S&F Ceiling rose, 3 terminal, PVC / polycarbonate, isolated body, complete all as specified and directed by Engineer-in-Charge.
S&F Electric bell (Ding dong) AC 230/250 volts grade single pole ISI marked, complete all as specified and as directed by Engr-in-Charge.
S&F Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch socket combination box type 5 pin 5 Amps flush type, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch socket combination box type 6 pin 16 Amps flush type, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket outlet Two in one, 3/5 Pin piano type 5 Amp and 15 Amp flush type, complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 1.5sqmm PVC insulated unsheathed multi stranded copper FRLS grade cable with one run of 1.5sqmm PVC insulated copper cable as earth continuity drawn in and including concealed PVC conduit not less than 20mm dia including modular spacers, saddles, junction boxes modular metal box and white cover plate for mounting of modular switches, Sockets etc and other accessories for one light / fan point/ Bell point controlled by one switch, complete all as specified and directed.
All as per Srl item No. 30 here-in-before but in same board.
All as per Srl item No. 30 here-in-before but one 5 Amp socket on independent board, complete all as specified and directed.
All as per Srl item No. 30 here-in-above but with 2.5sqmm PVC insulated unsheathed multi stranded copper FRLS grade cable with one run of 2.5 sqmm PVC insulated copper cable as earth continuity for power socket on independent board, complete all as specified and directed.
All as per Srl item No. 30 here-in-above but with 4 sqmm PVC insulated unsheathed multi stranded copper FRLS grade cable with one run of 4 sqmm PVC insulated copper cable as earth continuity for power socket on independent board, complete all as specified and directed.
All as per Srl item No. 30 here-in-before but one light point controlled two switches, complete all as specified and directed.
S&F Modular switch 01 way 06 A, 01 module including taking down unsv one, complete all as specified and directed by Engr-in-Charge.
S&F Modular socket, 6A-2/3 pin, 02 module including taking down unserviceable one, complete all as specified and directed by Engr-in-Charge.
S&F Modular switch 01 way 16A, 01 module including taking down unsv one, complete all as specified and as directed by Engr-in-Charge.
S&F Modular socket, 6A/16A-2/3 pin, 02 module including taking down unsv one, complete all as specified and directed by Engr-in-Charge.
S&F Modular bell push flush type 6A, 01 module including taking down unsv one, complete all as specified and directed by Engr-in-Charge.
S&F Modular fan step regulator 120W 02 module including taking down unsv one, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement Modular switch 01 way 06A, 01 module single pole 2 way 6 Amps, complete all as specified and directed by Engineer-in-Charge.
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location, complete all as specified and directed by Engr-in-Charge.
Hanging /fixing only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item No 43 here-in-above.
Fixing only LED tube light fittings of 5w/12W/20W/2'x2' panel light and LED bulk head fitting 9W as obtained from respective items of this BOQ, complete with all afixing accessories.
S&F in replacement LED light fitting with high output diffuser 1 feet, 5 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement LED light fitting mirror type with high output diffuser 2 feet, 10 /12 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement LED Bulk head (6500K) fitting of 09/10 Watt surface mounting type extruded aluminium body with diffuser complete with testing, complete all as specified and directed by Engr-in-Charge.
S&F in replacement surface/ recessed mounting LED luminarie 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed by Engr-in-Charge.
S&F Pristine spike LED light 7W suitable for outdoor environment IP66 protection including fixing arrangement like clamp nut bolts and washers and etc with necessary connection of suitable size copper conductor cable, complete all as specified and directed by Engr-in-charge.
S&F in replacement decorative wall light fixture made up of polycarbonate, suitable for 9W LED (B-22 base) complete with LED, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement energy saving LED garden light fitting, decorative, bollard type of capacity 9/11 watt with opal diffuser &aluminium reflector complete with all accessories and fixing arrangement on PCC block of size 45mm X 45 mm alogwith fixing nuts, bolts and PVC insulated aluminium conductor, stranded type of size 4.0 sqmm,2 -core including taking down old/Unsv garden light fittings any type and wattage, complete all as specified and directed.
S&F LED building security light fitting 25/35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
S&F in replacement decorative LED gate light fitting of 30/40 watt,240 volts, diecast aluminium housing in pure polyster powder coated grey finish,top maintainable product with opening die cast cover,anti corrosive stainless steel screws & silicon gasket,HET PMMA diffuser,IP65 protection driver duly prewired up to terminal on firms to IS 10322 part 5/sec, 1 :1987,suitable for pole of dia 65-75 mm in-built electronic driver complete including taking down old/Unsv gate light fitting complete all as specified and directed.
S&F in repair surface/recessed mounting LED warm light fitting POLARIS PAN NIO-III,PANEL 2'x2' PLR 36 FO-ww ,35/36 watt LED environmental friendly , new generation , aesthetically designed ,ultra modern recess mounting luminaire with high brightness SMD LEDs as light source suitable for Armstrong /grid /ceiling complete all as specified and directed.
S&F in replacement surface/recessed mounting LED down lighter round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Sub main wiring with two run single core 1.5 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia in PVC concealed conduit/PVC casing & capping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 1.5 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable sub main of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 1.5 sqmm and one run1.5 sqmm cable and one run of PVC conduit shall be measured as one RM
Sub main wiring with two run single core 2.5 sqmm FRLS copper conductor cable PVC insulated, 1100V grade including 25mm dia in PVC casing & capping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 2.5 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable sub main of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 2.5 sqmm and one run2.5 sqmm cable and one run of PVC casing and capping shall be measured as one RM
Sub main wiring with two run single core 4 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia PVC concealed conduit/PVC casing & capping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable submain of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 4 sqmm and one run 4 sqmm cable and one run of PVC conduit shall be measured as one RM
Sub main wiring with two run single core 6 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia PVC concealed conduit/PVC casing & caping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable sub main of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 6 sqmm and one run 6 sqmm cable and one run of PVC conduit shall be measured as one RM
Fixing only serviceable MCB DB of any type and capacity obtained from respective Item of this BOQ, complete all as specified and directed.
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 4 Way, complete all as specified and directed.
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 8 Way, complete all as specified and directed.
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 12 Way complete all as specified and directed.
S&F in replacement TPN 4 way sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 415V, 50Hz supply double door TPN system 4 way, complete all as specified and directed.
S&F VTPN MCCB Double door Distribution Board 04 way 415 volts grade IP 43 Protection Grade with provision for (MCCB) as incoming and Three/single phase (TP/SP) outgoings, complete with insulated bus bar arrangement fixed flush to wall complete including connections should be provide with necessary reducer lugs, complete all as specified and directed.
Fixing only serviceable MCB SPN/SP any capacity obtained from respective item of this BOQ, complete all as specified and directed.
S&F in replacement Thermal magnetic MCCB 4 pole 63 Amps 415 Volts 16 ka including making necessary arrangement, complete all as specified and directed.
S&F in replacementr thermal magnetic MCCB 4 pole 100 Amps 415 Volts 16 ka INCLUDING MAKING NECESSARY ARRANGEMENT, complete all as specified and directed.
S&F in replacement Thermal magnetic MCCB 4 pole 125/160 Amps 415 Volts 16ka including making necessary arrangement, complete all as specified and directed.
S&F in replacement connection and testing 'C' series SPN MCB 40 to 63 Amp 240V, 50Hz, 10kA for lighting and other domestic loads incl necessary copper lugs etc, complete all as specified and directed.
S&F in replacement 'C' series MCB SP 6-32 Amps, complete all as specified and directed.
S&F in replacement 'C' series MCB SP 40-63 Amps, complete all as specified and directed.
S&F in replacementr for MCB TPN 63 Amp, 415 Volts- C curve of 10kA, complete all as specified and directed.
S&F in replacement on load change over switch 4 pole, 415V in sheet metal enclosure 4 pole of capacity 100 Amps, complete all as specified and directed.
S&F in replacement Metal clad Plug socket single pole enclosure with two pin earth plug and socket with one single 20 Amp, 240 volts MCB, complete all as specified and directed.
S&F in replacement PVC insulated single core copper conductor of 1.5 sqmm, complete all as specified and directed.
S&F in replacement PVC insulated single core copper conductor of 2.5 sqmm, complete all as specified and directed.
S&F in replacement PVC insulated single core copper conductor of 6 sqmm, complete all as specified and directed.
S&F in replacement PVC insulated single core copper conductor of10 sqmm, complete all as specified and directed.
S&F in replacement Electrical PVC round plate cover complete all as specified and directed
S&F in replacementr PVC rectangular block for mounting switches, sockets, fan regulator etc. of size 200x150x50mm deep including making necessary cutting, complete all as specified and directed by Engr-in-Charge. Make : - Anchor/ Havells or equivalent ISI Marked make as approved by GE.
S&F in replacement PVC rectangular block for mounting switches, sockets, fan regulator etc. of size 250x200x50mm deep including making necessary cutting, complete all as specified and directed by Engr-in-Charge. Make : - Anchor/ Havells or equivalent ISI Marked make as approved by GE.
S&F in replacement 3 mm thick plastic laminated ebonite sheet cover of size 200x150mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc, complete all as specified and directed.
S&F in replacement 3 mm thick plastic laminated ebonite sheet cover of size 250x200mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc, complete all as specified and directed.
Taking down/removing existing damaged cable connection from MCB DB/Wall Mounted Panel Board by making cutting chases on wall/ floor to extend the shorten UG cable of any type/size from Loop and making fresh to reconnect the same with suitable aluminium lugs complete including distribute the load equally on each phase, complete all as specified and directed by Engr-in-Charge. Note : Cutting of Wall /Floor shall be measured and paid separately.
M&L for Cutting of hard standing n.exc 45 Cm depth, and n.exc 30 Cm width for taking out/laying UG Cable including making good disturbed surface as per existing, complete all as specified and directed.
M&L Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of MES Part-1 fixed in replacement including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil.(b) PCC Pit in cement concrete 1:2:4 type B-1.(c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm.(d) Funnel with watering pipe of GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering.(f) Requisite quantity of common salt and charcoal.(g) Testing of Earthing.Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be done by the contractor at his own risk and cost to the entire satisfaction ot the Engr-in-Charge.(b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
S&F in repair service wire unarmoured of size 10 Sqmm 2 Core, 1100V grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner shething of PVC tape and over all PVC Sheathed including taking down old/ Unsv serice wire, complete all as specified and directed.
S&F in repair service wire unarmoured of size 06 Sqmm 2 Core, 1100V grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner shething of PVC tape and over all PVC Sheathed including taking down old/ Unsv serice wire, complete all as specified and directed.
ARNABH ASSOCIATES (BID ID -3103547)
M/S BHARAT LIGHT ELECRIC.CO (BID ID -3100872)
DEV RAJ MAGOTRA (BID ID -3104883)
s l sharma and sons (BID ID -3119670)
MADAN LAL SHARMA AND SONS (BID ID -3118851)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .