Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-Finance HOUSE NO 599 D SURYA NAGAR PHASE II SECTOR 91 FARIDABAD 121013 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121013 | L1 | Accepted-Finance Lowet | |
| 2 | L2₹35.2 L+₹9,130 (0.26%)Accepted-Finance | L2 | Accepted-Finance Other than Lowest | |
| 3 | L3₹40.0 L+₹4.9 L (14.0%)Accepted-Finance | L3 | Accepted-Finance Other than Lowest | |
| 4 | L4₹44.9 L+₹9.8 L (28.0%)Accepted-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Accepted-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
21 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (U) Chandimandir
GE (U) Chandimandir Chandimandir Cantt Panchkula (HR)
GE(U)/CHM-17/2021-22 - PROVN OF REPAIRS / MAINTENANCE CUM PREVENTIVE MAINTENANCE OF LT SUPPLY SYSTEM AND CONNECTED ITEMS OF WORK AT CERTAIN LOCATIONS AT CHANDIMANDIR CANTT
2021_MES_449704_2
GE(U)/CHM-17/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Chandimandir Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (U) Chandimandir
₹90,000
Yes
24 Jul 2021
1 Jul 2021
23 Jul 2021
1 Jul 2021
21 Jul 2021
6 Jul 2021
60 days
Amount
Excavation in trenches for foundations, laying / taking out of cables, erecting of poles etc, in any type of soil, not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr in width and getting out, complete all as specified and as directed.
Returning, filling in soils, in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed
Removing excavated soils to a distance exceeding 50 metres and not exceeding 100 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point.
Cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregates), in foundation and mass concrete etc complete all as specified and as directed.
Cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregates) as in coping, blocks, bed plates, kerbs etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary formwork as required complete all as specified and directed.
Dry course sand , filled in trenches under and over underground cables as cushioning to cable complete all as specified and as directed.
Supplying and laying unreinforced precast concrete cable cover (ISI marked), class LV, type 1, flat, size 250mm x 150mm x 40mm, in trenches over sand as protection to cable complete all as specified and as directed.
100mm bore (internal dia) steel water tubing, galvanized light grade, laid in trenches /fixed to wall/ along pole or laid in trenches or under roads etc as protection to cable, with all fittings and fixtures like mild steel flat iron clamps of appropriate size and shape, nuts, bolts and washers as approved by Engineer-in-Charge complete all as specified and as directed, with and including taking up/down old damaged steel pipe and removing from site of work complete all as directed.
Double wall corrugated HDPE duct pipe of 100mm outer dia conforming to IS:14930 Pt-II with antirodant and non flame propergating properties of make and colour as approved by Engineer-in-Charge with fittings as protection to cable, laid in tranches or fixed to poles/walls complete all as specified and as directed.
MCCB four pole 400Amps, 415 volts, 50HZ breaking capacity not less than 36 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics = 100% of Icu, in replacement (taking down old damaged MCCB) complete all as specified and as directed. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-10 here-in-above but of 320 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-10 here-in-above but of 250 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-10 here-in-above but of 200 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-10 here-in-above but of 160 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-10 here-in-above but of 125 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-10 here-in-above but of 100 Amps. Make : L&T/ABB/Schnieder/Siemens
Change over switch ON LOAD type, 415 volt, 50 Hz, AC 4 pole, in steel metal enclosure, capacity 600 Amps rated current manually operated conforming to IS : 13947 or latest edition with high thermal and dynamic strength to withstand short circuit current level of 80 KA rms, in replacement, (taking down old damaged change over switch) complete all as specified and as directed.
All as per the description of serial item-17 here-in-above but capacity 400 Amps
Disconnecting and taking out old damaged/defective LT cable from trenches or taking down from poles or taking out from pipes below or above ground level, or for rerouting of cable aluminium conductor 1100 volts grade, size 50.00 sqmm, 3.5 core and removing unserviceable cable from site of work including taking out cable cover and pipe segregating serviceable/reusable cable cover and pipe, complete all as specified and as directed.
All as per the description of serial item-19 here-in-above but of size 70.00 sqmm 3.5 core
All as per the description of serial item-19 here-in-above but for of size 95.00 sqmm 3.5 core
All as per the description of serial item-19 here-in-above but of size 120.00 sqmm 3.50 core
All as per the description of serial item-19 here-in-above but for of size 150.00 sqmm 3.50 core
All as per the description of serial item-19 here-in-above but for of size 185.00 sqmm 3.50 core
All as per the description of serial item-19 here-in-above but for of size 240.00 sqmm 3.5 core
All as per the description of serial item-19 here-in-above but of size 300.00 sqmm 3.50 core
All as per the description of serial item-19 here-in-above but for of size 400.00 sqmm 3.50 core
Laying only, jointing and testing LT cable PVC insulated armoured, heavy duty 1100 volts grade with aluminium conductor of size 50.00 Sqmm 3.50 core, in trenches or thorugh ducts/ pipes or fixed to poles or walls through pipes under road, jointing to OH conductor, LT panle, main swithces etc, complete as specified and as directed. NOTE (i) Cable shall be issued under Sch-'B', free for fixing / laying only. (ii) Unit rate quoted is inclusive of cutting chases,if any in wall or under floor. (iii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-28 here-in-above but of size 70.00 sqmm 3.50 core NOTE (i) Cable shall be issued under Sch-'B', free for fixing / laying only. (ii) Unit rate quoted is inclusive of cutting chases,if any in wall or under floor. (iii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-28 here-in-above but of size 95.00 sqmm 3.50 core NOTE (i) Cable shall be issued under Sch-'B', free for fixing / laying only. (ii) Unit rate quoted is inclusive of cutting chases,if any in wall or under floor. (iii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-28 here-in-above but of size 120.00 sqmm 3.50 core NOTE (i) Cable shall be issued under Sch-'B', free for fixing / laying only. (ii) Unit rate quoted is inclusive of cutting chases,if any in wall or under floor. (iii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-28 here-in-above but of size 150.00 sqmm 3.50 core NOTE (i) Cable shall be issued under Sch-'B', free for fixing / laying only. (ii) Unit rate quoted is inclusive of cutting chases,if any in wall or under floor. (iii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-28 here-in-above but of size 185.00 sqmm 3.50 core NOTE (i) Cable shall be issued under Sch-'B', free for fixing / laying only. (ii) Unit rate quoted is inclusive of cutting chases,if any in wall or under floor. (iii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-28 here-in-above but of size 240.00 sqmm 3.50 core NOTE (i) Cable shall be issued under Sch-'B', free for fixing / laying only. (ii) Unit rate quoted is inclusive of cutting chases,if any in wall or under floor. (iii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-28 here-in-above but of size 300.00 sqmm 3.50 core NOTE (i) Cable shall be issued under Sch-'B', free for fixing / laying only. (ii) Unit rate quoted is inclusive of cutting chases,if any in wall or under floor. (iii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-28 here-in-above but of size 400.00 sqmm 3.50 core NOTE (i) Cable shall be issued under Sch-'B', free for fixing / laying only. (ii) Unit rate quoted is inclusive of cutting chases,if any in wall or under floor. (iii) Excavation and earth work if required shall be measured and paid for seperately.
Supply, laying , jointing and testing LT underground electric cable XLPE insulated, PVC sheathed armoured heavy duty 1100 volts grade heavy duty multystranded aluminium conductor laid in trenches / ducts or passing through under road or fixed to poles or walls complete all as specifed and as directed of following size :--
Cross sectional area 50.00 sqmm 3.50 core
Cross sectional area 70.00 sqmm 3.50 core
Cross sectional area 95.00 sqmm 3.50 core
Cross sectional area 120.00 sqmm 3.50 core
Cross sectional area 150.00 sqmm 3.50 core
Cross sectional area 185.00 sqmm 3.50 core
Cross sectional area 240.00 sqmm 3.50 core
Cross sectional area 300.00 sqmm 3.50 core
Cross sectional area 400.00 sqmm 3.50 core
Material and labour for cutting existing bituminous/cement concrete road/hard standing/pavement of size 30 cm x 30cm for passing through the cables/pipes and surrounding /filling the entire cut space with cement concrete 1:3:6 type C-I after laying of pipe/cable and finishing the top surface fair and even complete all as specified and as directed.
Supply, installation, testing and commissioning of out door type LT feeder pillar/ distribution boards in replacement (including taking up / down old feeder pillar) thermoplastic polycarbonate IP 65 in accodance with EN 60 529, dust proof, rust proof, water proof & weatheproof, metering panel shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extinguishing, UV resistant, Silica and halogen free recyclable material, glow wire tested at 9600 C in accordance with IEC 60 695-2-11. Type tested as per IEC 60 439-1. Total insulated with system. The manufacture of boar/panel shall submit a copy of CPRI test report of degree of ingress protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane ; while the gasket shall be internally embedded. The manufacture of board/ panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC60439-1. The report shall mention the following tests performed and passed out satisfactory:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric Properties. (d) Short circuit withstand current. (e) Effectiveness of protective circuits. (f) Clearance & creepage distance. (g) Mechanical operation. Polycarbonate enclosure shall be fire retardant & self extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3,UL subject 94 for Flammability V-2. It shall be tested at Glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08.
Srl Item No 39 Contd..... The lid closing and opening shall be done by quick fastering spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel. These accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit. The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. Each board shall have individual routine test report of the manufacture & the panel board will have the following accessories. (a) 4 Nos heat shrink insulated bus bar of 1.5 times of incoming MCCB including all connection with aluminum strip. Incoming: (i) MCCB four pole, 415 Volts, 50 HZ, 400 Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu -01 Nos Make : ABB/Schnieder/L&T/Siemens.. Outgoing (i) MCCB four pole 415 Volts ,50 HZ, 100Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 02 Nos . Make : ABB/Schnieder/L&T/Siemens. (ii) MCCB four pole 415 Volts ,50 HZ, 160Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 03 Nos . Make : ABB/Schnieder/L&T/Siemens. Note :-All the switchgear to be used in the panel will be of same make.
Supply, installation, testing and commissioning of out door type LT feeder pillar/ distribution boards in replacement (including taking up / down old feeder pillar) thermoplastic polycarbonate IP 65 in accodance with EN 60 529, dust proof, rust proof, water proof & weatheproof, metering panel shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extinguishing, UV resistant, Silica and halogen free recyclable material, glow wire tested at 9600 C in accordance with IEC 60 695-2-11. Type tested as per IEC 60 439-1. Total insulated with system. The manufacture of boar/panel shall submit a copy of CPRI test report of degree of ingress protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane ; while the gasket shall be internally embedded. The manufacture of board/ panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC60439-1. The report shall mention the following tests performed and passed out satisfactory:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric Properties. (d) Short circuit withstand current. (e) Effectiveness of protective circuits. (f) Clearance & creepage distance. (g) Mechanical operation. Polycarbonate enclosure shall be fire retardant & self extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3,UL subject 94 for Flammability V-2. It shall be tested at Glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08.
The lid closing and opening shall be done by quick fastering spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel. These accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit. The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. Each board shall have individual routine test report of the manufacture & the panel board will have the following accessories. (a) 4 Nos heat shrink insulated bus bar of 1.5 times of incoming MCCB including all connection with aluminum strip. Incoming: (i) MCCB four pole, 415 Volts, 50 HZ, 400 Amps microprocessor based with LIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu -01 Nos . Make : ABB/Schnieder/L&T/Siemens. Outgoing (i) MCCB four pole 415 Volts ,50 HZ, 100Amps microprocessor based withLIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 09 Nos . Make : ABB/Schnieder/L&T/Siemens. (ii) MCCB four pole 415 Volts ,50 HZ, 200 Amps microprocessor based with LIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 01 Nos . Make : ABB/Schnieder/L&T/Siemens. Note :-All the switchgear to be used in the panel will be of same make.
Supply, installation, testing and commissioning of out door type LT Panel in replacement (including taking up / down old panel) factory made CPRI approved openable from front & rear double door type, dust and vermin proof, fabricated out of 3.15 mm CRCA sheet of duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer complete with 4 Nos heat shrink insulated bus bar of 1.5 times rating of incoming MCCB including all connection with aluminium strip pillar board shall be provided with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including , MS channel frame of ISMC 75 at base of panel only and 04 Nos legs of not less than 75 cm long each below the base of panel made of angle iron 50 x 5 0 x 6 mm for grouting purpose and grouted in PCC 1:2:4 type B1( using 20 mm graded stone aggregate) complete all as specified and directed by Engr-in- charge and comprising of following accessories:- Incoming:- (i) MCCB four pole, 415 Volts, 50 HZ, 400 Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu -01 Nos Make : ABB/Schnieder/L&T/Siemens. (ii) Onload type changeover switch 400 Amp - 01 Nos
Outgoing (i) MCCB four pole 415 Volts ,50 HZ, 400Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 01 Nos . Make : ABB/Schnieder/L&T/Siemens. (ii) MCCB four pole 415 Volts ,50 HZ, 160 Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 03 Nos . Make : ABB/Schnieder/L&T/Siemens. (iii) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (d) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear to be used in the panel will be of same make.
Taking down old unserviceable ACB any type and Supply, installation testing and commissioning new LT ACB of 630 415 Volts, 50 Hz, Amps four pole mannual draw out microprocessor based, with LCD display with complete set of LSIG protection with self power release with fault indication and with 20 trip history with time stamping suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar /nut bolts/lugs complete all as specified and directed by Engr-in-charge. Make : ABB/Schnieder/L&T/Siemens
Taking down old unserviceable ACB any type and Supply, installation testing and commissioning new LT ACB of 800 415 Volts, 50 Hz, Amps four pole mannual draw out microprocessor based, with LCD display with complete set of LSIG protection with self power release with fault indication and with 20 trip history with time stamping suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar /nut bolts/lugs complete all as specified and directed by Engr-in-charge. Make : ABB/Schnieder/L&T/Siemens
Supply and fix multimeter flush mounitng type, digital type, voltage range 0 to 750V and current rating 0 to 1000 Amp, 50 Hz, 96 x 96 mm complete all as specified and directed by Engr-in-Charge.
Supply and fix indicator lamp, LED type of colour red/ green complete all as specified and directed by Engr-in-Charge.
Supply and fix godrej pattern lock for LT panel matching with the existing complete all as specified and directed by Engr-in-Charge.
M&L for painting of LT out door panel in front, top, rear and both sides above ground level with two coats of synthetic enamel paint as per existing colour after preparation of surface and writing panel number complete all as specified and directed by Engr-in-Charge.
M&L, in repairs (including dismantling and taking out) electric panel doors fabricated from MS sheet as per existing size and shape and fixed with hinges by properly welding and checking for proper opening and closing complete all as specified and directed.
Supply, installation, testing and commissioning of out door type LT feeder pillar/ distribution boards in replacement (including takint up / down old feeder pillar) thermoplastic polycarbonate IP 65 in accodance with EN 60 529, dust proof, rust proof, water proof & weatheproof, metering panel shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extinguishing, UV resistant, Silica and halogen free recyclable material, glow wire tested at 9600 C in accordance with IEC 60 695-2-11. Type tested as per IEC 60 439-1. Total insulated with system. The manufacture of boar/panel shall submit a copy of CPRI test report of degree of ingress protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane ; while the gasket shall be internally embedded. The manufacture of board/ panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC60439-1. The report shall mention the following tests performed and passed out satisfactory:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric Properties. (d) Short circuit withstand current. (e) Effectiveness of protective circuits. (f) Clearance & creepage distance. (g) Mechanical operation. Polycarbonate enclosure shall be fire retardant & self extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3,UL subject 94 for Flammability V-2. It shall be tested at Glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08.
The lid closing and opening shall be done by quick fastering spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel. These accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit. The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. Each board shall have individual routine test report of the manufacture & the panel board will have the following accessories. (a) 4 Nos heat shrink insulated bus bar of 1.5 times of incoming MCCB including all connection with aluminum strip. Incoming (i) MCCB four pole, 415 Volts, 50 HZ, 400 Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu -01 Nos Make : ABB/Schnieder/L&T/Siemens. Outgoing (i) MCCB four pole 415 Volts ,50 HZ, 250Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 01 Nos . Make : ABB/Schnieder/L&T/Siemens. (ii) MCCB four pole 415 Volts ,50 HZ, 160Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 03 Nos . Make : ABB/Schnieder/L&T/Siemens. Note :-All the switchgear to be used in the panel will be of same make.
Supply, installation, testing and commissioning of out door type LT Panel factory made CPRI approved openable from front & rear double door type, dust and vermin proof, fabricated out of 3.15 mm CRCA sheet of duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete with 4 Nos heat shrink insulated bus bar of 1.5 times rating of incoming MCCB including all connection with aluminium strip pillar board shall be provided with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including , MS channel frame of ISMC 75 at base of panel only and 04 Nos legs of not less than 75 cm long each below the base of panel made of angle iron 50 x 5 0 x 6 mm for grouting purpose and grouted in PCC 1:2:4 type B1( using 20 mm graded stone aggregate) complete all as specified and directed by Engr-in- charge and comprising of following accessories:- Incoming:- (a) MCCB four pole, 415 Volts, 50 HZ, 400 Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu -01 Nos Make : ABB/Schnieder/L&T/Siemens.
Outgoing (i) MCCB four pole 415 Volts ,50 HZ, 160Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB,breaking capacity 36 KA with Ics = 100% Icu - 01 Nos . Make : ABB/Schnieder/L&T/Siemens. (ii) MCCB four pole 415 Volts ,50 HZ, 100 Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 05 Nos . Make : ABB/Schnieder/L&T/Siemens. (iii) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (iv) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear to be used in the panel will be of same make.
Supply, installation testing and commissioning of out door type L T feeder piller box in replacement (including taking up/down old panel) CPRI approved openable from front & rear double door type, dust and vermin proof, fabricated out of 3.15 mm CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MS channel frame of ISMC 75 at base of panel only and 04 Nos legs of not less than 50 cm long each below the base of panel made of angle iron 50 x 50 x 6mm for grouting purpose and grouted in PCC 1: 2:4 type B1 (using 20 mm graded stone aggregate) alongwith incoming MCCB four pole, 415 volts, 25 KA 50 Hz, 200 amps - 01 Nos including 4 Nos heat shrink insulated aluminum bus bar of 1.5 times rating of incoming MCCB including disconnecting and taking out old unserviceable feeder pillar and removing from site of work complete all as specified and as directed. Make : ABB/Schnieder/L&T/Siemens.
Supply, installation testing and commissioning of out door type LT Panel factory made CPRI approved openable from front & rear double door type, dust and vermin proof, fabricated out of 3.15 mm CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer with 4 Nos heat shrink insulated bus bar of rating 1.5 of incoming MCCB including all connection with aluminium strip pillar board shlal be provide with danger notice plate with skull and bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including MS channel frame of ISMC 75 at base of panel only and 04 Nos legs of not less than 75 em long each below the base of panel made of angle iron 50 x 50 x 6 mm for grouting purpose in PCC 1 :2:4 type B1 [ using 20 mm graded stone aggregate) including disconnecting and taking out old unserviceable panel and removing from site of work complete all as specified and directed and comprising of following accessories :- Incoming:- (a) MCCB four pole, 415 Volts, 50 HZ, 320 Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu -01 Nos Make : BB/Schnieder/L&T/Siemens. Outgoing :-(a) MCCB four pole 415 Volts ,50 HZ, 200 Amps microprocessor based with LIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 01 Nos . Make : ABB/Schnieder/L&T/Siemens. (b) MCCB four pole 415 Volts ,50 HZ, 160Amps microprocessor based with LIG & LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 03 Nos . Make : ABB/Schnieder/L&T/Siemens. Note :-All the switchgear to be used in the panel will be of same make.
Removing wild grass vegetation, creeper etc around LT panel/transformer/poles, stay assembly, climbing upwards including cleaning bottom surfaces on ground of area not less than 1.00m x 1.00m including surface dressing n.exc 15cm deep in any type of soil and removing rubbish to outside mob lad complete all as directed.
Aluminium bus bar of different size and capacity as per site requirement and as directed by Engineer-in-Charge including PVC insulating materials and cutting, welding as required, making holes and fixed in position including taking down old bus bar and removing from site of work, all as directed.
Earthing complete with galvanized iron or steel plate electrode 600mm X600mm X 6.0 mm burried directly in ground vertially in a pit of depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth of not less than 1.50m below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to with and including GI/ Steel strip of size 32mmx6mm upto a length of 7.50 metre by means of bolts, nuts, check nuts & washers of galvanized iron /steel, earth strip protected by and including galvanized steel pipe light grade of bore 40 mm (internal dia) & connected to main control board / switch board or any other electrical equipment complete all as shown in electrical plate No : 3 MES SSR including necessary excavation & earth work, disposal of surplus soil not exceeding 50m, in any type of soil. (The rate also includes for cost of charcoal & salt in alternate layers of 15 cm thickness, 20 mm bore internal dia GI/steel pipe light grade) for watering, funnel, wire mesh, PCC chamber in cement concrete (1:3:6) type C-1, 40mm thick RCC(1:2:4) type B-0, reinforced with XPM of weight not less than 4.00 kg/Sqm and mild steel frame of angle 50mmx50mmx6mm and testing on competion including dismantling / taking out existing earthing and removing dismantling / taken out materials outside the defence land complete all as directed.
Note: Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit Revised in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
M/S BALWINDER SINGH
Vasudeva Trading Co.
R D Bansal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .