| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹61.4 LAdmitted-Finance KHATI SAHI PO CHILIKA NUAPADA DS KRUSHNA PRASAD GANJAM ODISHA PIN 752011 | PURI | ODISHA | 752011 | -25.01% | ₹61.4 L | L1 | Admitted-Finance |
| 2 | L2₹66.5 LAdmitted-Finance AT KHARIAR PO KHARLAR DIST NUAPADA | NUAPADA | ODISHA | 766104 | -18.70% | ₹66.5 L | L2 | Admitted-Finance |
| 3 | L3₹69.6 LAdmitted-Finance | -14.99% | ₹69.6 L | L3 | Admitted-Finance |
| 4 | L4₹73.1 LAdmitted-Finance | -10.70% | ₹73.1 L | L4 | Admitted-Finance |
| 5 | L5₹73.7 LAdmitted-Finance CONSTRUCTION OF BOUNDARY WALL AND MAIN GATE OF GOVT AYURVEDIC DISPENSARY BUILDING AT BHUSKUNDA IN THE DISTRICT OF MAYURBHANJ | BALESHWAR | ODISHA | 756028 | -9.99% | ₹73.7 L | L5 | Admitted-Finance |
Tender Value
₹81.8 L
EMD Value
₹81,834
Closing Date
3 Feb 2026, 5:00 pmClosed
SE (A), SZ, Berhampur
Office of the Superintending Engineer (Agril.), Southern Zone, Brahmapur, Rangeilunda, Ganjam, Odisha - 760007
Construction of Soil Testing Laboratory, Berhampur at Rangeilunda, Dist - Ganjam
2026_AGRIL_124678_1
SE(Agril.) SZ 06/2025-26
Open Tender
Civil Works - Buildings
240 days
Rangeilunda
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
Superintending Engineer (Agril.), Southern Zone
₹81,834
Yes
10 Mar 2026
19 Jan 2026
5 Feb 2026
19 Jan 2026
3 Feb 2026
19 Jan 2026
Excavation of foundation in hard soil within 50 m initial lead and 1.5 m initial lift including rough dressing and levelling as per the direction of engineer in charge
Filling foundation and plinth with sand well watered and rammed including cost and conveyance of materials.
C.C.(1:4:8) with 4 c.m. size h.g. metal in F&P.
Brickwork (1:6) with 23 cm FA Bricks having crushing strength 75 kg/sqcm in F&P including cost conveyance and royalty of materials curing etc complete
Brickwork (1:6) with 23 cm FA Bricks having crushing strength 75 kg/sqcm in Super Structure including cost conveyance and royalty of materials curing etc complete
Ground Floor
First Floor
Second Floor
R.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusherbroken) stone chips including hoisting and laying in ground floor
(a) Column base, frustum, plinth band
(b) Bed Block
(c) Lintel
(d) Column and beam
(e) Sun shade, loft and Chajja
(f) Roof Slab
(g) Stair
R.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusherbroken) stone chips including hoisting and laying in first floor
(a) Bed Block
(b) Lintel
(c) Column and beam
(d) Sun shade, loft and Chajja
(e) Roof slab
(f) Stair
R.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusherbroken) stone chips including hoisting and laying in second floor
(b) Lintel
(c) Column and beam
(d) Sun shade, loft and Chajja
(e) Roof slab
Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification
Ground Floor
First Floor
Second Floor
16 mm thick cement plaster in c.m(1:6) over brick masonry
Ground Floor
First Floor
Second Floor
12 mm thick cement plaster in c.m(1:6) over brick masonry
Ground Floor
First Floor
Second Floor
6 mm thick cement plaster (1:4) to RCC Surfaces finished smooth including closed deep chipping and slurry treatment
Ground Floor
First Floor
Second Floor
Priming 1-coat with any approved primer over wall surface including cost of primer
Finishing plastered surface of walls with Cement based wall putty (Water Based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc. complete
Ground Floor
First Floor
Second Floor
Finishing walls with weather coat-2 coats of approved shade to give an even shade including cost of paint etc.
Ground Floor
First Floor
Second Floor
Wall painting -2 coats with plastic emulsion paint of approved shade on new work to give an even shade including cost of paint.
Ground Floor
First Floor
Second Floor
Supplying, fitting & fixing of Industrial Vitrified tiles (30 x 30) cm in floors laid on 20mm thick CM (1:4) and filling joints with white cement of aproved quality including cost of all materials
Supplying, fitting & fixing Vitrified tiles (60 x 60) cm in floors laid on 25mm thick CM (1:4) and filling joints with white cement of aproved quality including cost of all materials
Ground Floor
First Floor
Fixing of ceramic glazed tiles 30cmx20cm/20cmx20cm special plain/printed series in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete including cost of tiles.
Ground Floor
First Floor
Fixing of ceramic glazed tiles 30cmx20cm/20cmx20cm special plain/printed series in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete including cost of tiles.
Fixing of ceramic glazed tiles 30cmx20cm/20cmx20cm special plain/printed series in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete including cost of tiles.
Fixing Vitrified tiles (60 x 60) cm in dado, skirting & risers of steps of 12 mm thick CP (1:3) joined wth neat cement slurry mixed with pigments to match th shades of the tiles including rubbing and polishing complete including cost of tiles
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90m C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect
Supply, fitting and fixing of MS grill and ventilators including painting two coats over a coat of primer including cost of transportation.
Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures
Providing, fitting & fixing of Aluminium door with OEL anodized Al door section of 9202 as vertical member, 9201 as top member and 9200 as bottom & middle member and 12mm prelaminated board fixed on door frame by means of tapered clip No 4660 and the frame to be completed by means of jointing angle No 1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges etc complete.
Providing fitting and fixing of false ceiling with Aluminum anodised T Section No. 3215 with 2'-0 center to center, L section NO. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2-0 x 2" - 0" with India Gypsum board of 125mm thick. etc. complete.
Supplying, fitting and fixing of factory-made WPC CHOUKATH provided with plug in socket arrangement and joined together by screws including all fittings with cost of all materials, labour,T&P etc. all complete required for the work
Providing and fitting fixing of 32mm thick flush door made out of 32mm thick block board including cost conveyance of all materials and labour for fitting, cost of iron fittings etc. Complete including cost of Sal frame of 10cmx8 cm fitting fixing of frame in position and Aldrops, Hinges, Tower bolts,Handles all complete for Door as per the direction of engineer-in-charge, excluding labour cess and GST.
Providing and applying of post construction antitermite treatment by drilling 12mm dia holes at a distance of 30cm and at junctions of wall and floor about 300 apart and deep enough to reach the soil below and chemical emulsion (PREMISE, IMIDACHLOPRIED 30.5 SC OF BAYER MAKE mixed with 475 ltrs water) pumped these holes to soak the soil @ 1ltr. solution of each hole as per manufactureers specification and the holes should be plugged with filling materials including cost of all materials, labour charges, conveyance and all taxes and hiring charges of machineries etc. complete as per direction of Engineer-incharge.
Supplying and fixing of Roller blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60 mm thick fabric of approved design and quality etc. complete. (vide item no 5 of Misc Item pg no 234 of SoR-22)
Electrification
Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider (Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
Group-A, short point
Group-B, medium point
Group-C, long point
Recessed wiring to 5A /6Amp Modular socket outlet with 2 X 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess 20mm dia non metallic PVC flexible conduit with Modular Switch phenolic laminated sheet suitable size ISI marked MS box and earthing point with 1 X1.5sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc. as required (Make of wire -Finolex/ L&T/ Anchor/ Havells/V-Guard/Great White/HPL)
Supply & Fixing of 5/6 amp, 3-pin Modular socket with 6 Amp Switch on existing board.
Separate Modular Plug point with switch
Supply & Fixing of Modular metal box on surface or in recess wirh suitable size of modular cover in front icluding providin and fixing of 5 pin 6 Amp & 6 Amp modular switch connections (Make of wire -Finolex/ L&T/ Anchor/ Havells/V-Guard/Great White/HPL)
Supply & Fixing of Modular metal box on surface or in recess wirh suitable size of modular cover in front icluding providin and fixing of 6 pin 6 Amp & 16 Amp modular Socket outlet and 16 Amp Switch connections (Make of wire -Finolex/ L&T/ Anchor/ Havells/V-Guard/Great White/HPL)
Wiring of circuit/Recessed Sub-main wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor, ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit, 1.6 mm in recessed PVC conduit as required (Make of wire- Finolex/L&T/Anchor/Havells/V-Guard/Great White/Mescab/HPL)
2 X 1.5 sq.mm + 1 x 1.5 sq.mm
2 X 2.5 sq.mm + 1 x 1.5 sq.mm
2 x 4.0 sq.mm. + 1 x 1.5 sq.mm.
4 X 4sq.mm + 2 X 2.5sq.mm
4 x 6.0 sq.mm. + 2 x 4 sq.mm.
S/F of Power Point with 2 Modular & 4 Modular metal box with Modular base & Cover in recess including providing & fixing of 5 pin 15/16 Amp Modular Switch & Socket with Mini DP MCB connection as required for AC
S/F of 18 SWG Modular Metal Box with of following size in recess with suitable modular base & cover ijn front including cutting the wall as requieed.
2 modular Box with base & cover
4 modular Box with base & cover
S/F of 4 way single pole and neutral double door sheet Steel MCB Distribution Board (Without MCB)
Double door 4 way
8 way, Double door
S/F of 5 -32 amp rating, 240 volt 'B' series MCB for lighting and other loads in the existing MCB distribution board, ISI marked, complete with connection, testing and commissioning etc. as requierd(make-HPL/ Havells/ Legrand /L&T/C&S)
5 - 32 amp SP (SinglePpole) MCB
Supply and fixing of 32 Amp ICDP mainswitch with MS Board
Supply and fixing of 63 Amp ICDP mainswitch with MS Board
Supply and fixing of superior type Ding Dong call bell / buzzer of ISI marked, on 6" X 4" conforming to IS-2268/ 1994 and bell push of ISI marked , conforming to IS-1293/ 1988 (Make-Anchor / Cona/ Great white).
Ding dong calling bell with MS board and cover.
S/F of Ceiling Fan 48" (1200 mm) aluminium body, copper winding with accessories & connection without reglator(Make-Crompton/Havells/Usha/eqv.)
S/F of 400 mm Wall fan, aluminium body, copper winding with all accessories & connection (Make Crompton/Havells/ Usha/ Polycab/ Eqv.):-
S/F of Exhaust Fan of size 10"/12" along with accessories and connections
S/F of Exhaust Fan of size 9"/10" along with accessories and connections
S/F of eletronic step type regulator for ceiling fan in existing swich board including connections (Cona/Anchor/eqv. )
S/F of Bakelite angle holder/batten holder in place of ceiling rose
S/F of 9 watt LED Tube Light (Havels/Phillips/Crompton/Surya) with all complete
S/F of 18-25 watt LED Tube Light (Havels/ Phillips/ Crompton/ Surya)
S/F of 40 watt LED Street Light fitting (Make- Havells/ Phillips/ Bajaj/ Crompton) with all complete
S/F of 36 watt, (2'x2') LED Square Light, recessed fitting (Phillips/Bajaj/Havells) with all complete
S/F of 15 watt, (1'x1') LED Square light, recessed fitting (Phillips/Bajaj/Havells/PAC) with all complete
Supply and Fixing of 12 watt recess LED Cicular Light fitting in ceiling (Make- Havells/ Phillips/ Bajaj/ Crompton ) with all complete
S/F of Computer Board consisting 3 nos 5amp and 1 nos 15amp switch and socket (Piano Type)(Make:Cona/Grate White/ Anchor)
Supply and fixing of Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required as per the direction of Engineer-in-charge.
S/F of SWG No.6/No.8 copper wire for earth continuity.
Borewell
Labour for drilling a perfectly vertical bore well of 200mm dia below ground level by use of own rig with its accessories, tools and plant and consumables etc for lowering of PVC casing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (PVC casing pipe if required to prevent collapse of over burden.
from 00 m to 50 m
Labour for drilling a perfectly vertical bore well of 150mm dia below ground level by use of own rig with its accessories, tools and plant and consumables etc for lowering of PVC casing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (PVC casing pipe if required to prevent collapse of over burden.
from 50 m to 150 m
Cost of 200mm dia casing pipe of ISI No 12818/1992)
Cost of lowering of casing pipe (200mm dia PVCpipe)
Washing and developing charges
Cost of 1.5HP submerssible pump ISI marked (Lubi/Crompton/Greaves/Kirlosker)
Cost of PVC/HDPE column pipe (32mm)
Cost of submersible cable of ISI marked
Accessories for pump fitting (reducer, nipple, short piece, bore cover etc) upto overhead tank
Stainless steel wire rope for suspending the pump
Cost of control panel of approved make
Installation charges for pumpset, control panel and accessories.
Transportation of all PVC pipes, Pump, accessaries and fittings
PH & Sanitary works
Supplying all materials, labour, T & P for cutting holes in brick/stone masonry walls in all floors for taking GI/PVC pipes and fittings through & making good to the damages with CM(1:4) etc. all complete to pass through 125mm to 250 mm thick walls.
Supplying all labour T & P & materials & cutting grooves in pucca floors & walls veritically & horizontally to the required depth & width for fixing GI/PVC pipes & fittings, testing the pipe line against leakage & making good to damages etc. all complete.
Supplying all materials, labours, taxes and T&P etc for fitting & fixing of U-PVC/Sch. PVC pipes (ORIPLAST/Equvalent make) of following dia to walls,ceiling and floors with clamps/hooks & including making good to damages etc. all complete.
c) 25 mm dia PVC (ASTM) pipe
d) 32 mm dia PVC (ASTM) pipe
Supplying all materials, labour, T & P in all floors for fitting & fixing of U-PVC fixtures of the following diameter including supply of required jointing materials etc. all complete
25 mm dia Ball Valve
25 mm dia union
25 mm dia elbow
25 mm dia Tee
Supplying all materials, labour, T & P for fitting and fixing of different types of Brass/ CP fittings accessories including supply of jointing materials etc. all complete.
15 mm dia long body CP bib cock/pillar cock
15 mm dia short body CP bib cock/pillar cock
15 & 20 mm dia CP plain/angle/concealed stop cock
15 mm dia Twin (2-in-1) bib cock with hand spray for Europian pan
110 mm dia CP grating/Floor jally
15 mm CP 2 way Angle Cock
15 mm CP Angular Stop Cock
15 mm CP revolving Shower bend type
Supplying all materials, labour, T & P in all floors for laying in trenchs unplastisized PVC SW pipes confirming to IS:4985-2000 class-IV (4Kgf/Cm2) of following ominal bore including supply of jointing materials and testing etc. all complete
75 mm dia PVC pipe
110mm dia PVC pipe
Supplying all materials, labour, T & P in all floors for fitting and fixing of PVC SW pipe fittings of the following diameter to walls with nails, bobbins,wooden plugs laying in trenches including jointing with rubber lubricant by non-heat appliction method, testing, earthwork in excavation and refilling of trenches etc-all complete
110 mm dia door Tee
110 mm dia plain Tee
110 mm dia P -Trap/N-Trap
110 mm dia door bend
110 mm dia plain bend
110 mm dia cowl
75 mm dia door Tee
75 mm dia plain Tee
75 mm dia P -Trap/N-Trap
75mm dia door bend
75 mm dia plain bend
75 mm dia cowl
110/75/50 mm dia clamp
Supplying all materials, labour, T & P and fixing vitreous Water Closet European type squatting pan with 10 Ltr Flushing Cystern or commode duly embedded in C.C. (1:5:10) with P or S - trap including jointing of trap with pan in CM(1:1), cutting the floor and making good to the damages etc. all complete (One Set) (Johnson,Hindware,Parryware)
Supplying all materials, labour, T & P and fixing 10 Ltr Flushing Cystern only cutting the floor and making good to the damages etc- With all complete (Johnson,Hindware,Parryware)
Supplying all materials,labour and T&P for fixing bowl pattern urinal including connecting the urinal with waste pipe by means of white lead mixed with chopped hemp etc. all complete as per specification.[3.3.8./339] (Including cost of Gents standing urinal ) 380x580x350 (Johnson,Hindware,Parryware)
Supplying all materials,labour and T&P for fixing bowl pattern urinal including connecting the urinal with waste pipe by means of white lead mixed with chopped hemp etc. all complete as per specification.[3.3.8./339] (Including cost of Ladies Squating Urinal ) (600x355 mm) (Johnson,Hindware,Parryware)
Supplying all materials, labour, T & P and fixing Wash Basins with hole for pillar cock with cast iron or M.S. brackets including cutting holes in walls and making good to the damages with supply of wooden plugs, screws and cement etc. and connections to waste pipe /pillar cock / supply main line etc. all complete :- With Bib Cock & all fittings (Johnson,Hindware,Parryware)
Supplying all materials, labour, T & P and fixing Steel Kitchen Sink for Laborotory with hole for pillar cock with cast iron or M.S. brackets including cutting holes in walls and making good to the damages with supply of wooden plugs, screws and cement etc. and connections to waste pipe /pillar cock / supply main line etc.all complete:- (24" X 18" X 10") Size Steel Sink with Bib Cock & all fittings
Supplying all materials, labour, T & P and fixing Bevelled Edge Mirror of superior glass mounted on 6mm thick plywood sheet and fixed to wooden plugs with CP screws and washers complete :- 600mmx450mm mirror
Supplying & fixing standard size CP towel rails/ towel rings complete with CP brass brackets fixed to wooden plugs with CP screws
a) Towel Rail (24 " )
b) Towel Rail (18 " )
c) Towel Ring
Supplying all materials, labour, T&P and Constructing Gully Trap Chamber of the following inside sze with 8cm thick RCC precast cover slab in CC(1:2:4) mix using 12mm size hg chips ,foundation concrete (1:4:8) using 40mm size hg metal on bed around trap,FA brickwork in CM(1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmX100mm size gully trap,150mmX150mm C.I grating including watering, curing,conveyance of all materials to worksite,payment of royalty,taxes etc all complete as per approved drawing,specifications and direction of Engineer in charge
Supplying all materials, labour, T&P and Constructing Septic Tank of Size(2.5mx2mx1.8mdepth) of the following Outside sze with Sand &CC(1:3:6) mix both depth 0.125m using 40mm size hg metal on bed,1st class FA brickwork in CM(1:4),12mm Cement Plaster (1:4) with punning to inside,cement flush pointing (1:3) to outside, RCC cover slab of 5 inch in M20 using 12mm size hg chips with RCC man hole cover,earthwork in excavation in all kinds of soil and refiling the cavity around the chamber including watering, curing,conveyance of all materials to worksite,payment of royalty,taxes etc all complete as per approved drawing,specifications and direction of Engineer in charge
Supplying all materials, labour, T&P and Constructing Inspection Chamber of the following inside sze with CC(1:3:6) mix using 40mm size hg metal on bed,1st class FA brickwork in CM(1:6),moulding and shaping the channel inside and benching with CC(1:2:4) using 12mm size hg chips,12mm thick cement plastering (1:3) finished with punning to inside,cement flush pointing (1:3) to outside, RCC cover slab in (1:2:4) using 12mm size hg chips with RCC man hole cover,earthwork in excavation in all kinds of soil and refiling the cavity around the chamber including watering, curing,conveyance of all materials to worksite,payment of royalty,taxes etc all complete as per approved drawing,specifications and direction of Engineer in charge (Inside Size-760mmX760mmX460mm)
Supplying & fixing standard size CP Soap case/ Soap stand fixed to PVC plugs & screws etc.
Supplying all materials, labour, T &P etc and filling/fixing of ( 60 cm x 12.5 cm) plate glass shelf with brackets and all accessories.
Supplying all materials, labour, T & P and fixing SINTEX/Equivalant OH water storage tank including cutting holes through the tank and fixing PVC tubes, fittings, sockets etc including hoisting upto a height of 5 m. above ground level and placing in required position over RCC beam and R.C.C. slab along with provision of brick work in CM (1:6) for circular protection wall around the tank including centering, shutering, watering, conveyance of all materials etc- all complete.
a) 1000 lit PVC tank
b) Staging with RCC and brick work
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.81 MB
BOQ_576152.xls
BOQ • 0.62 MB
Download all tender documents and submit your bid