Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-Finance 28 HARISAVA ROAD BARRACKPORE KOLKATA 700122 | 24 PARAGANAS NORTH | WEST BENGAL | 700122 | ₹48.0 L | L1 | Accepted-Finance L1, Financially Qualified as Lowest Bidder |
| 2 | L2₹49.8 LRejected-Finance 87 20 BOSE PUKUR ROAD KOLKATA 700042 | KOLKATA | KOLKATA | WEST BENGAL | 700042 | ₹49.8 L | L2 | Rejected-Finance L2, Financially disqualified |
| 3 | L3₹51.4 LRejected-Finance 15E CHAULPATTI ROAD KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | ₹51.4 L | L3 | Rejected-Finance L3, Financially disqualified |
| 4 | L4₹51.9 LRejected-Finance 138 PURBA PALLY KOLKATA 700078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | ₹51.9 L | L4 | Rejected-Finance L4, Financially disqualified |
| Sl No | Description | Qty | Unit | J S CONCLAVE PVT.LTD. L1 | THE SHOPP L3 | Bharat Construction L4 | M/S UDAYAN CONSTRUCTION L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | TOTAL QUOTED AMOUNT | 1 | LS | 48,01,137 ₹48.0 L | 51,42,758 ₹51.4 L | 51,88,463 ₹51.9 L | 49,77,628 ₹49.8 L |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
2 Feb 2026, 3:00 pmClosed
Superintending Engineer
DG Block, Sector- II, Salt Lake City, Kolkata-700091
Development and Beautification works on River Embankment at the junction point of the Damodar and Hooghly River at Purba Basudevpur, Garchumuk.
2026_WBTDC_989992_1
NIT No.108/WBTDCL OF 2025-26 (Technical)
Open Tender
CIVIL AND ELECTRICAL WORKS
120 days
Gorchumukh
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹1 L
27 Feb 2026
16 Jan 2026
4 Feb 2026
16 Jan 2026
2 Feb 2026
16 Jan 2026
TOTAL QUOTED AMOUNT
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Civil
Supplying,fitting and fixing double swing (made with -MS Circular hollow section) with iron twisted hanging chain including colour and necessary tools for fixing
Supplying,fitting and fixing iron Circular swing with colour and necessary tools and as per choice of EIC
Supplying,fitting and fixing Plain slide (made with FRP and MS hollow section) including colour and necessary tools for fixing and as per choice of EIC
Supplying,fitting and fixing double slide (made with FRP and MS hollow section) including colour and necessary tools for fixing and as per choice of EIC
Supplying,fitting and fixing jungle gym (made with FRP and MS hollow section) including colour and necessary tools for fixing and as per choice of EIC
Supplying,fitting and fixing seat MGS (made with FRP and MS hollow section) including colour and necessary tools for fixing and as per choice of EIC
Supplying,fitting and fixing spiral slide (made with FRP and MS hollow section) including colour and necessary tools for fixing and as per choice of EIC
Supplying,fitting and fixing Elephant model (made with FRP and MS hollow section) including colour and necessary tools for fixing and as per choice of EIC
Supplying,fitting and fixing Zebra model (made with FRP and MS hollow section) including colour and necessary tools for fixing and as per choice of EIC
Supplying, fitting and fixing CAST IRON decorative chain of dwarka make of model no DBL-109-L or equivalent and as per choice of EIC
Electical
Light Fittings:
Cable, Gland & Socket:
SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF1.1 KV GRADE AS PER IS7098 (PART1) 1988 WITH UPTO DATE AMENDMENTS. (Make: Polycab/Finolex/ KEI/ RR Kabel ) (a) 4 Core 6 sq. mm
(b) 4 Core 35 sq. mm
Lighting Panel :
SITC of Feeder pillar box, Outdoor type, IP65 protection, MS powder coated (RAL 7032), sheet steel thickness 1.6 mm, Free standing, MS stand for easy operation (panel bottom should be 300 mm from Ground level), interconnection, Cabling, Terminals, DIN Rail, cable entry bottom with detachable gland plate, Openable hinged double/single door as per relevant IS with suitable foundation & net cement polising (min 1.5 cum required), having following incoming and out going feeder. (Make: L&T/ ABB / Legrand) INCOMING: 1. Busbar: 4 bars, 415 V, 63 A-4 Set 2. 22.5 mm dia LED indicating lamps-1 Set 3. 240 VAC analog times witch for ON-OFF control-6 Set 4. 3 pole power contactor type ML3, 40A-6 Set 5. 3 pole Thermal overload Relay type MN-2, Relay range 20A to 33A-6 Set OUTGOING: 1. Side Cable Box- 4 ways 100A-2 Nos. 2. 240/415 V MCB of Breaking capacity 10kA & C characteristics (A) 6-32 A FP- 4 Nos (B) 6-32 A SP- 12 Nos 3. Danger board (15 cm. x 10 cm. )-2 Nos. 4. WIRES (i) 3 x 22/0.3 (1.5 sqmm)-40 Mtr. (ii) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC-25 Mtr. (iii) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC-20 Mtr. 5. socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes (a) 2.5 Sq.mm-40 Set (b) 4 Sq.mm-10 Set FOUNDATION: (i) Brock work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)- 4 Cum. (ii) 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4 (1 cement : 6 fine sand)- 2.5198 Sqm Including FABRICATION, WASTAGE MATERIAL, TRANSPORTATION (LOADING & UNLOADING) INCL.
Foot Lamp and strip Light:
Supply of LED 22W smart batten tube light 6500K/4000k extruded aluminum housing, Longer life of 25k hrs, with wide voltage protection 140-270V. [Make: Philips (SmartBrite Batten) / Bajaj/ Crompton / equiv make as per choice of EIC.]
Supply of 400 mm sweep 3 blade non decorative Wall fan, Pull cord control for speed and oscillation On-Off, High speed motor for higher air delivery, Thermal Overload Protection. [Make: Havells (Swing off-white) / Usha/ Crompton / equivalent make as per choice of EIC.]
Supplying of different types of LED lamps (9W)- Make : Philips, 9.0 Watt, Base B22/ E27, 825 Lm.
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Civil
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared)
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. (b) above 150 mm. thick
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
ordinary Cement concrete(1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes with Pakur Variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Reinforcement for reinforced concrete work in all shorts of structure including distribution bars , stirrups, binders etc. initial straightening and removal of loose rust (if necessary) cutting to requisite length, hooking, and bending with 16 gauge black anealed wire at every intersection , complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4m. i) Tor steel/Mild steel
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows railing etc. fitted and fixed with necessary screws and lugsinground floor.(Add extra @1% for each addl. floor upto 4th floor and @1.25% for each addl. floor above 4th floor) (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. (MODE OF MEASUREMENT): The weight of grill per sq.m. will be determined by taking the physical weight of fabricated grill and dividing the same by covered area of the same. (ii) Grill weighing above 16 Kg./sq.mtr and above
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (a) One Coat
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved makeand brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) (iv) Two coats (with any shade except white)
Brick work with 1st class bricks in cement mortar (1:4) (a) In foundation and plinth
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in- Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5. (c) Supplied and laying in the specified pattern of Interlocking Concrete Block Pavement (ICBP) with concrete blocks (with Concrete as specified as per Table-1 of IS :15658 : 2006) manufactured from BIS Licence Manufacturer, with spacer nib (Small protruding profiles on the vertical face of a Paver Block used as a device for keeping minimum joint gap between the Paving Blocks, as per Cl. No. 3.26 of IS 15658) and of specifed size and shape with aspect Ratio (The ratio of length to thickness of a Paver Block, as per Cl. No. 3.3 of IS 15658) as per Table - 2 of IS :15658 : 2006 with flexural strength / breaking load as per Annexure - G of IS 15658 on the prepared Base Course of specified CBR as per Table-1 of IRC SP 63 (2018) or else as mentioned in design and drawing with a cushing of compacted bedding sand of 25-35 mm thick (grading of the bedding sand as per Cl. No. 6.5.1 of IRC SP 63) and filling up the gaps in between Paver Blocks with joint filling sand (grading of the bedding sand as per Cl. No. 6.5.2 of IRC SP 63) and completing the edges with cut blocks as per Cl. No. 8.7 of IRC SP - 63 (2018) with proper confinement of bedding and joint filling sand, compacting, levelling and filling up the edge gap. 60 mm thick
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface (i) With 1:6 cement mortar (b) 20 mm thick plaster
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter.
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.
Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for nonpressure underground Drainage, Sewerage & Cross drainage application (i) 150mm internal dia.
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 ( 8 parts of stacked volume of earth after reduction by 20%, one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary watering and finally fine dressing, levelling etc.,including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50m lift upto 1.5m complete.This includes supply of labour, tools & plants including materials.Planting hedge plants in two rows at 30cm apart
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
Supplying and Planting of different plant / trees ( Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift, carriage, handling, manuring, applying presticide and fertilizer etc xiv) Acalypha species ( Red/Green) of height 30cm-90cm in earthen pots of size 25cm.
xvii) Bougainvillea (mix variety) of height 30cm-90cm in polybag of size 10cm-15cm.
xx) Croton (broad leaves) 3-5 branches of height 90cm- 120cm in cement pots of size 30cm.
xxviii) Dracaena (Mahatma) of height 30 cm to 90 cm in earthen pots of size 20 cm.
xxxiii) Dracaena Reflexa of height 30 cm to 90 cm in earthen pots of size 20 cm.
xxvi) Areca Palm 4 - 5 suckers of height 90 cm to 105 cm in earthen pots of size 25 cm.
Electical
Supplying and fixing Sheet steel Main Switches on angle iron frame on wall (415V TPN with fuse on L&N)- 125 A (Make: Havells)
Supplying and Drawing 1.1 KV single core stranded 'FRLSH' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. (Make- Polycab/Finolex/ KEI/ RR Kabel) (u) 4x36/0.3 (2.5 sqmm) + 2x22/0.3 (1.5 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. (a) 2.5 Sq.mm
(b) 4 Sq.mm
Light Fittings:
Erection of Single Steel tubular pole of length as given below with /without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly (a) Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene /polythene pipe entry, for street light wiring, without Loop Box
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting (a) 200 x 150 x 100 mm
Painting Block Letters or Digits within a circle/square as required, with ”Black Japan” paint of approved make & brand, the size of letters and digits as given below 40 mm and upto 50 mm
Cable, Gland & Socket:
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : (a) 4 Core 6 sq. mm
(b) 4 Core 35 sq. mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : (a) 4 Core 6 sq. mm
(b) 3½ Core 35 sq. mm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required: (a) 80 mm dia
Earthing:
Excavation of soil for installation of Earth Electrode and filling & ramming. (a) For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: (a) By ISI-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages: (a) No. 8 SWG
Foot Lamp and strip Light:
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. (u) 4x36/0.3 (2.5 sqmm) + 2x22/0.3 (1.5 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. (a) 2.5 Sq.mm
Cutting Channel of size (40mmx40mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3mm thick Polythene pipe by means of anchoring chemical (Hilti /Sika ) and GI 'U' hooks of 8SWG incl. supplying and drawing 18 SWG GI wireas Fish wire and mending good damages to original finish by using own tools and tackles
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 9 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. On Board
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles 25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm)
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment - 2 Way
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection - 6-32A DP
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Fixing only bulk head/ ceiling fitting/ surface mounted on wall /ceiling by screws etc.
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Sub Total
Add GST @18% .
Sub Total
Add labour welfare Cass @ 1%
INR Twenty Seven Lakh Seventy Seven Thousand One Hundred & Ninety Seven Only
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.91 MB
2911.pdf
Tender Documents • 0.50 MB
BOQ_2419349.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid