| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC 11 SANJIV BAUG SOCIETY NEW SHARDA MANDIR ROAD PALDI AHMEDABAD GUJARAT 380007 | AHMADABAD | GUJARAT | 380007 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹25.2 L+₹2.2 L (9.42%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹25.3 L+₹2.2 L (9.69%)Rejected-Finance D 1 A 72 UPPER GROUND FLOOR JANAK PURI JAI ROAD NEW DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | L3 | Rejected-Finance Other than lowest |
Tender Value
₹28.2 L
EMD Value
₹56,400
Closing Date
23 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE New Delhi
HQ CWE New Delhi, Rao Tula Ram Marg, Delhi Cantt-10
Provn of lift for specially abled children at NCS, Chanakyabagh, New Delhi under GE New Delhi Delhi Cantt
2021_MES_488692_1
CWE-ND/35/2021-22
Open Tender
Miscellaneous Works
Item Rate
120 days
Delhi Cantt
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE New Delhi
₹56,400
Yes
23 Feb 2022
18 Nov 2021
25 Dec 2021
18 Nov 2021
23 Dec 2021
9 Dec 2021
60 days
Amount
Design supply, install, testing and commissioning of environmental friendly passenger machine room less elevator/lift for 08 passenger, speed 1 metre/sec, Lift with Synchronous axial motor 415 V, 3 phase AC 50 Hz supply conforming to IS- 14665, suitable to serve G+02 upper floors with AC V3F drive complete with all standard accessories, simplex automatic & neutral duel controlled operation with/without attendant , entry through centre opening frameless glass doors with door drive (electric motor driven mechanism). Automatic rescue drive (ARD) system, 3D infrared door sensor in full height of door & built in announcing system without handset (02) Nos, one each in car & near ground floor landing door all as specified. The elevators AC gearless housing unit so compact can be mounted onto the guide rail in a standard shaft and the controller is built into the door on the top landing . Braille buttons to be integrated in COP and surface mounted LOP. complete all as specified including accessories and necessary equipment (gear placed directly above the hoist way)catering to 2 floor for opening on the same side with following:-
Car enclosure :- (a) Car Design - MIPHP002; Midrange Premium HP2 (b) Car Panel finish- side walls: Black Beads Blast StSt Rear wall; Black Beads Blast StSt Front wall; Black (c) Handrail: Flat straight painted Traffic Black at Rear Wall (d) Ceiling & Lighting: -Turbo Spot light straight black Beads Blast StSt Turbo spot LED light. (e) Flooring: 20 mm. (f) Car door finish : stainless steel AISI441 (g) Landing Door Finish: Floor Number: 1-3 Floor Mark:-0,1,2 inter floor distance: 4000 mm Landing door Material: stainless steel AISI441 (h) Car operating panel - 1 Full Height Black mirror polish StSt ST4: silver brushed StSt (TYP_COP_DISPLAY_1(1))Round surface mounted with braille KDS93 (i)Landing signalization: stainless steel 1-Dot Matrix display surface Mounted ST4-silver brushed Round surface mounted with braille KDS93
Standard:-Car Emergency Light, Fireman drive, curtain of light 169 Beams, Automatic closed doors Additional: Emergency Rescue Device, 2 way dedicated intercom, attendant service, Lift Announcer, Turbo spot LED light
Safety measures as per manufacturer's design: (i) Over load relays and warning device. (ii) Contacts and fuses of suitable size and capacity. (iii) Electrical terminals, of suitable size and capacity. (iv) Limit switch with accessories on each door /cage. (v) Gravity /counter weight limit switches for top most position. (vi) Electro magnetic brake of suitable size with manned released arrangement. (vii) Phase sequence corrector & single phase preventer. (viii) Painting work with super enamelled synthetic pain to all the exposed surfaces all as directed by GE/Engineer-in-Charge. (ix) Provision of necessary electrical wiring of lift well / shaft with FRLS copper cable multistranded 1.5 Sqmm, LT 1100 Volts grade for minimum 5 points including bulk head luminary LED 15 watt. Make : Bajaj / Philips / Crompton Greaves. (x) One inspection lamp and one power socket 5/15 Amps on top of car. (xi) Display of wiring diagram of lift control panel.
Note :- (i) "Press & Speak" system to be connected with lift (ii) Intercom in the cabin & machine room shall be connected with existing communication network as desired. (iii) Dos & Don'ts chart on steel plates have to be installed inside car cabin. (iv) Contractors must check the details and dimensions at site before quoting the rates. The lift car door opening and landing door opening must be aligned with lift well opening so that maximum lift well opening is available at each floor. No addition/alteration to existing RCC columns will be permitted to provide necessary lift car/landing gate opening. (v) 415 Volts 3 Phase 50 Hz, AC supply shall be made available by MES and the contractor has to make necessary connections to the lift panel board. (vi) The rate quoted by the contractor is deemed to be inclusive of preventive and periodical maintenance for 02 years after completion of work as per the manufacturer's guide lines.
(vii) Provide of Automatic Rescue Device (ARD) by providing UPS of adequate capacity with SMF battery(s) having a power back up for minimum 30 minute stop at the car a get at the nearest floor level for auto opening of door & for ejaculation of passenger & to operate car cabin fan, car lights, emergency lights, and alarm bell and intercom in the event of electric break down all as directed by GE. (viii) Provn of voltage fluctuation with standing capacity to new microprocessor controller to safe guard the electric circuit and to enable smooth functioning of the light in case of voltage fluctuation in the system. (ix) Provision of safety guard equipment such as two Nos pit switches controller guarding pit pulley, guarding pit ladders, fascia plates to cover free space between car cabin and hoist way & switches.
S&F in Heavy duty Exhaust fan for shaft 450 mm (Metal Body) size with louvers suitable for ,1400 rpm, 90 W, 1710 cubic m/hr, 240V, 50 Hz single phase AC supply including fixing on wall with nut, washer etc. complete and necessary electrical connection from ceiling rose to fan connecter with three core sheathed wire of required length complete all as specified and directed.
S&F MCBs 16 Amps DP, 10 kA rupturing capacity and fixing in DBs complete all as specified and directed.
S&F LED bulkhead fitting of 10 W extruded aluminium heat sink provided foe efficient heat dissipation & integrated electronic driver in AC complete all as specified and directed.
S & F of TPN Metallica 4 way DB door with MCB TPN 63 Amp as incomer for LIFT suitable for MCCB/RCCB/isolator as incomer and should be properly fixed in the wall with the help of hooks and connecting all required connections for proper electric supply complete all as specified and directed.
S&F Wiring of circuit /submain wiring FRLS copper conductor 2x4 Sqmm for phase wire & 1x4 Sqmm for earth wire of copper armoured conductor for single phase supply complete all as specified and laying with PVC conduit fixing on the wall with proper saddle complete all as specified and directed.. Note:- Phase should be of Red /Yellow/Blue, neutral should be of back and earthing wire should be of green colour. 2. Two runs of cable for phase/ neutral , 1 run for earth lead & PVC conduit will be measured and paid as unit length).
Supply and fixing ELCB, 4 pole, 240/415 volt of capacity 63 amp, breaking capacity not less than 300 mA with 10kA short circuit withstand capacity JEC-61008-I, IS-12640-I , including thimbles, nuts, bolts ,washers etc. and connections,. complete all as specified and directed.
M&L in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing as required 25x4 mm galvanised iron strip complete all as specified and directed.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25x4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board / test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil all as specified.
Supply, Installation, Testing & Commissioning of 10 KVA/8 KW factory assembled unpacked silent DG set of 16 BHP Diesel Engine directly coupled alternator mounted on common base frame fitted with AVM pads complete with fuel tank, standard Manual control panel, Battery with leads and acoustic enclosure(canopy) as per latest CPCB Norms along with K-oil premium & K-cool(coolant) complete all as specified & directed .
M&L for reinforced cement concrete in foundation 1:2:4 type B-2 with 40 mm graded stone aggregate complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq. mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq. mm 3.5 core complete all as specified and directed.
Supply, installation, testing and commissioning of LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel, weather & vermin proof fabricated of 3.15 mm thick CRCA sheet, duly powder coated inside & outside over one coat of red oxide primer, mounted on an angle iron frame made out of size (50 x50 x6) mm having 90 cm high legs, including welding on all four corners with locking arrangement comprising of 50 mm size Godrej padlock with duplicate keys, two earthing terminals, suitable glands for incoming / outgoing cables, including grouting of panel 60 cm above GL, embedded in PCC (1:2:4) using 20 mm graded stone aggregate up to 30 cm, prewired, connectors etc. complete all as specified & directed with following accessories.
(a) 4 Nos Aluminium bus bars, 03 Nos for phase (R,Y,B) of rating 400 Amp and 01 No for neutral of rating 50 Amps mounted on heavy duty rubberized / porcelain support:- 01 set. (b) MCCB 250 Amp rating, 25 KA, four pole Adjustable type (for incoming ) – 01 No. (c) MCCB 4 pole 63 Amp for lift-01 Nos. (d) MCCB 4 pole 160A Amp for Fire pump-01 Nos. (e) MCCB 4 pole 63 Amp for water supply-01 Nos. (f) Ammeter (0 to 100) amp, Digital type having scroll type switch with CT’s. (g) Voltmeter (0 to 500) V, Digital type scroll type switch. (h) Indicator lamp LED type.
M/s Dhapola Elevator and Engineering
Choice india
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .