Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 CrAccepted-AOC | ₹29.9 Cr | L1 | Accepted-AOC Lowest bid |
| 2 | L2₹31.2 CrRejected-AOC | ₹31.2 Cr | L2 | Rejected-AOC Not being lowest |
| 3 | L3₹31.9 CrRejected-AOC NO 157 14 13TH B MAIN ROAD 1ST STAGE PHASE I GOKULA BANGALORE 560 054 | BANGALORE | BANGALORE | KARNATAKA | 560054 | ₹31.9 Cr | L3 | Rejected-AOC Not being lowest |
| 4 | L4₹32.2 CrRejected-AOC | ₹32.2 Cr | L4 | Rejected-AOC Not being lowest |
| 5 | L5₹32.6 CrRejected-AOC | ₹32.6 Cr | L5 | Rejected-AOC Not being lowest |
Tender Value
₹30.5 Cr
EMD Value
₹15 L
Closing Date
22 Oct 2024, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
PROVISION OF DEFICIENT MD ACCN FOR OFFICERS PHASE I AND FOR JWO AND ABOVE AT AF STATION YELAHANKA
2024_MES_651084_3
801572/AF/E8
Open Tender
Civil Works
2460 days
GE (AF) YELAHANKA
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE (AF) YELAHANKA
₹15 L
Yes
19 Nov 2024
1 Oct 2024
25 Oct 2024
1 Oct 2024
22 Oct 2024
15 Oct 2024
2 Oct 2024 - 11 Oct 2024
Amount
BOQ Dated Sep 2024
GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XIII are prepriced by MES under Ser No. 1 to 13. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Building or works” as listed in Schedule ‘A’ Part–I
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for “Internal Electric Supply" as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “Site Clearance ” as listed in Schedule ‘A’ Part – IV.
Lumpsum price worked out by the contractor for “Road / Path / Culvert" as listed in Schedule ‘A’ Part V .
Lumpsum price worked out by the contractor for "Sewage Disposal" as listed in Schedule ‘A’ Part VI .
Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part – VII.
Lumpsum price worked out by the contractor for “Fencing & Gate” as listed in Schedule ‘A’ Part – VIII.
Lumpsum price worked out by the contractor for “Rain Water Harvesting” as listed in Schedule ‘A’ Part – IX.
Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – X.
Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – XI.
Lumpsum price worked out by the contractor for “Lightning Protection” as listed in Schedule ‘A’ Part – XII.
Lumpsum price worked out by the contractor for “Fire Fighting/Alarm System” as listed in Schedule ‘A’ Part – XIII.
Sch 'A' Part - XIV : DG SET Supply and installation, test and commissioning of acoustic proof diesel engine driven generating set fully wired 415 volts + 5% AC 3 phase 4 wire 50 Hz having capacity 12 KW/15 KVA continuous rating at power factor 0.8 (lagging) as per IS 4722 and connections as per IE rules complete with integrated AMF control panel of suitable capacity with microprocessor based relay and safety accessories as per the latest engineering practices . DG set shall be mounted on common base plate with anti vibration pads and placed on PCC foundation of required size as recommended by OEM. The Gen Set shall conform to CPCB norms II for noise and emission limits and necessary certificate from NAL or equivalent authority to this effect shall be submitted and all as specified and directed consisting of the following :-
[a] DIESEL ENGINE. The diesel engine shall be 4 stroke, water cooled, turbo charged developing minimum at 1500 RPM under NTP conditions of BS: 5514. The engine shall be provided with electrical starting arrangement & shall be suitable to produce an electrical output of 12 KW/ / 15 KVA at 0.8 power factor. The engine shall complete with :- Starter motor and charging alternator. Battery as recommended by OEM Dry type air cleaner Fuel pump with injectors A1 class governing Flywheel with flywheel housing Residential silencer First fill of lube oil suitable for 12 Hours continous running at full load Engine protections: Low lube oil pressure & High Water temperature.
[b] ALTERNATOR. The alternator shall be self excited self regulated brush less and self ventilating type designed for an output of 12 KW/15 KVA, 50 Hz, 415Volts 4 wire continous rating at 0.8 PF, with class 'F' or better insulation, screne protected, drip proof in IP- 21 enclosure and confirming to IS -4722 BS EN 60034-1 and directly coupled with the engine incl control panel with accessories complete with electric supply terminal box with gland plate, earth terminal etc all as specified.
[c] AMF Panel. AMF panel totally enclosed cubical type dust and vermin proof, with sloped canopy, standard industrial pattern, factory fabricated out of 2.0 mm thick CRCA steel sheet painted with one coat of red oxide primer and two coats of anticorrosive synthetic enamel powder coated of approved colour, complete with all mounting structures, insulators, bolts, nuts, washers etc, with necessary control wiring/internal connections with proper size of copper conductor cables / strips, suitable for 3 phase, 4 wire, 50Hz, 415 volts AC system, comprising of microprocessor based AMF relay unit with sensing on mains and DG with necessary safety / protection, MCCB 415 Volt 50 Hz 32 Amp 16 KA rating adjustable microprocessor based 4 pole (as incomming)-02 Nos and 2 Nos 4 pole power contactor of 32 Amps for Mains and DG supply, frequency meter, 3 Phase electronic type AC digital type KWH meter with suitable CTs, electronic earth fault protection relay.
All as per item No 14 above but capacity 32 KW/40 KVA and switchgear for AMF Panels MCCB 415 Volt 50 Hz 63 Amp 16 KA rating adjustable microprocessor based 4 pole (as incoming) - 02 Nos and 2 Nos 4 pole power contactor of 63 Amps.
M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6mm thick burried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to galvanised iron strip of size 32mm x 6mm as earth lead upto a length of 7.5 metre long by means of bolts,nuts, washers etc. and protected by GI pipe medium grade 20 mm dia and 40mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and including necessary earth work excavation in any type of soil ,PCC (1:3:6) type C2 bed and chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as directed. NOTE: (i) The unit rate includes earth wire and protection pipe up to (maximum 7.5 metre from earth plate) earth point/test point. (DG SET-18+Lift-8+E.W.S-16+E.E.S-32+Fire fighting-12+L.P-8
Sch 'A' Part - XV : LIFTS Design, supply, install testing & commissioning passengers lift suitable to carry 13 Passengers (884 Kgs), speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS 14665, suitable to serve G+7 upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) Car Dimension 2000mm wide x 1100mm deep x 2300mm high, Door opening : 900mm wide x 2000mm high, car flooring : 3mm thick aluminium chequered plate flooring, Handrail: Round handrail in stainless steel finish provided on one side. Car design : All car walls in 1.2mm thick stainless steel hairline finish, alarm button, car fan, door open, door close button in car operating panel, emergency light, infra red screen for car door, intercom, motor over hear protection, fire man switch, pit ladder other standard fittings and fixtures. Phase failure and Phase reversal protection etc all as conforming to IS 14665 (Part -I) 2000 all as specified and as directed.
Design, supply, install testing & commissioning passengers lift suitable to carry 8 Passengers (544 Kgs), speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS 14665, suitable to serve G+7 upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) Car dimension 1300mm wide x 1100mm deep x 2300mm high, Door Opening : 800 mm wide x 2000mm high, Car flooring : 3 mm thick aluminum chequered plate flooring, Handrail : Round handrail in stainless steel finish provided on one side Car design : All car walls in 1.2mm thick stainless steel hairline finish, alarm button, car fan, door open and door close buttons in car operating panel, emergency light, infrared screen for car door, intercom, motor overheat protection, fire man switch, pit ladder other standard fittings and fixtures. Phase failure and phase reversal protection etc all as conforming to IS 14665 (part-1) 2000 all as specified and as directed.
Sch 'A' Part - XVI : Aviation Obstruction Light: Supply and fix aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure of capacity 48watt Uniform illumination 360 Degree, ever lite LED, Color Red , Led life 100000 hours, operating voltage – 230V AC, power consumption 8.5watt, IP 65 vertical protection, special aluminum alloy body (LM-6) complete all as directed.
Supply and fix Digital time switch with battery backup, Single Pole module, 24 hours programmable every 20 min, backup of 100 hrs, current capacity 16 Amps, with 1 change over including distribution board and suitable contactor complete all as directed.
Sch 'A' Part - XVII : Fittings, Fixtures & Misc.items : Internal Water Supply : Supply and fix 15mm bore angle cock cast copper alloy fancy type chromium plated for PP-R/GI pipe complete all as directed.
Supply and fix 15mm bore fancy type long body bib tap cast copper alloy chromium plated for galvanised iron PP-R/GI pipe complete all as directed.
Supply and fix 15mm bore kitchen sink tap, brass chromium finish dual flow pattern with silicon black flexible hose swivel type all as directed.
Supply and fix 15mm bore washing machine tap, brass chrome for PP-R/GI pipe complete all as directed.
Supply and fix chromium plated shower rose 125mm size, roses with or without swivel joints any size including shower arm 15mm size, 195mm long with bend of 45 degree with flange and fixing to steel pipe or union complete all as specified and as directed.
Supply and fix 15mm dia, stop valve concealed type chromium plated fancy type with long shank and cup complete all as specified and as directed.
S & F 15mm bore two way bib tap, cast copper alloy chromium plated fancy type, screwed down, screwed for PP-R /GI pipe providing aerated flow of water complete all as directed.
Internal Electric Supply: Supply and fixing LED lights fitting 1x 20W, 6500K, cool light, Total 2000 Lumens, luminous efficacy 100 lumen/watt, AC decorative box type with driver, holder including retrofit LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED lights fitting 1x 10W, 220V, Lumen efficacy 110 Lumen / watt, Total Lumen 1100, 6500 K, Cool day light, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed .
S&F LED light fitting mirror type with high out put diffuser 2 feet, 05 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed .
Supply and fixing LED lamp 7 Watt B-holder type base with polycarbonate diffuser and aluminium heat sink complete all as specified and as directed.
Supply & fixing of 35/36 watts LED Security light fitting with pressure die cast IP 65 protection, luminous efficiency of 100 lm/watt, PF > 0.95, CRI > 80, colour temperature 5700 K suitable for primary roads with all connected accessories including bracket made out of GI tubing of 25mm outer dia, 1.2m length, light grade with GI clamps, nuts and bolts etc for fixing of fitting complete all as directed.
Supply and fix Wall mounting fan ,400 mm sweep, 70 CFM, power consumption 50 W all as directed.
M & L for Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized earth wire 4mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as directed. NOTE: (i) The unit rate includes earth wire and protection pipe up to (maximum 7.5 metre from earth plate) earth point/test point.
Design, supply, installation, integration, testing and commissioning of smart meters with pre-paid metering facility, AC three phase, four wire 415 volts, 50Hz, 10 to 60 Amps all as per BIS 16444 : 2015 ( Reaffirmed 2020 ) with plug-in type bi-direction communication Module (The plug-in Module shall be field swappable /replaceable)including necessary communication infrastructure suitable for integration with approved communication technology GPRS / RF / Hybrid (GPRS + RF) / any other advanced technology as per CEA / TRAI regulations etc. easily adaptable or network interface and integration with Advanced Metering Infrastructure (AMI)the project area complete in all respects, incl suitable mounting arrangements all as specified and as directed by Engineer-in-charge
Supply and fix Modular TV Socket, one module all as directed.
Supply and fix Modular Telephone socket ,RJ-11, one module all as directed.
M&L Telephone Wiring with unarmoured Solid annealed bare copper industrial cable in concealed of size 0.5 mm ,3 pair with PVC Conduit 25 mm dia all as directed.
M&L TV Wiring with unarmoured coaxial cable, RG-11 in concealed with PVC Conduit 25 mm dia all as directed.
M&L Mild steel Box for Telephone wiring including blocks , suitable for 35 Pair all as directed.
Supply and fix Electric Chimney of size 60 CM, Air suction capacity from 1000 to 1200 cubic mtr / Hr, filter less and dry heat automatic clean technology , Air pipe of size 150 mm dia all as directed.
Material and labour Aluminium ducting pipe of 150 mm dia including making necessary size hole in wall finishing to match with the surroundings all as directed. .
S&F Round shape 12 Watt, 220 Volts, Total 1200 Lumens, luminous efficacy 100 lumen/watt,AC surface type with high efficiency PMMA Diffuser, soft glare free light complete with drivers, holders, Led lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed.
BLANK
Design, supply, installation, integration, testing and commissioning of smart meters with pre-paid metering facility, AC single phase, two wire, 240 volts, 50Hz, 10 to 60 Amps all as per BIS 16444:2015 (Reaffirmed 2020) with plug-in type bi-directional communication Module (The plug-In Module shall be field swappable /replaceable), including necessary communication infrastructure suitable for integration with approved communication technology GPRS / RF/Hybrid (GPRS+RF) / any other advanced technology as per CEA / TRAI regulations etc. easily adaptable for network interface and integration with Advanced Metering Infrastructure (AMI) of the project area complete in all respects, incl suitable mounting arrangements all as specified and as directed by Engineer-in-charge.
BLANK
Road/Path/Culvert S & F solar stud, made of aluminium alloy and construction, size 125 x 125 x 25mm, solar powered by monocrystal solar panel, having one high capacity Ni-Cd rechargeable battery for power back upto 12 Hrs and 3 Nos LEDs-010mm each side total 06 nos, viewer distance 1000mtrs, fixing with nail/ screws/fastener/ polymer adhesive/ epoxy bond to the road surfaces, after preparation and making even surfaces, complete ( Make : Dark Eye/ /Green-lite/3M or equivalent)
S&F dual directional reflective road studs (cat eye) of impact resistant plastic stud 110mm X 110mm, double moulded solid state having ultra-voilet resistant colour (white/red/yellow) with four round disc containing 28x2-56 mini retro reflective glass beads of colour white/red/yellow to a side provided with L-key steel 12mm dia bolt along with ABS plastic stem of length 55mm for fixing on road with epoxy adhesive complete all as specified and directed by Engineer-in-Charge. ( Make : Dark Eye/ /Green-lite/3M or equivalent)
S&F of convex mirror size 80 to 100mm dia with and including stainless steel post length 2.10 mtr above GL and diameter of pole 100mm including necessary excavation, foundation ,filling the post hole with PCC 1:2:4 type B2 (using 40mm graded crushed stone aggregate) complete all as directed.
M & L Preparation of new road surfaces and applying reflective thermoplastic road marking paint (White or golden yellow) of minimum 2.50 mm thick (conforming to BIS-3262), single coat as in centre line and edge line road marking of 150/ 100mm width using 'HOT MARK' by indigenous modern propelled road marking machine as directed including all ingredients such as binder, glass beads, titanium dioxide, calcium carbonate, inter filler as specified in table 803.4 of MORTH specification, thermoplastic requirement for glass beads shall be as specified in (intermix) type-I, MOST/BS 6088A and road marking shall done as per provisions contained in IRC-35-1997, complete all as directed .
Rain water Harvesting: Development of trial bore holes of 200 mm dia up to 30m depth below ground level in any kind of soil strata including hard stone/boulder including electric logging MS cap MS flat iron clamps, reducing socket etc (3 bore holes 30x3 as required for each bore holes)
S & F nylon mesh of size 2mmx1mm all as directed .
M&L for UPVC (SCH-80) pipe 200 mm dia bore in any length laid in trench/bore well and all jointed all as directed.
M&L for perforated UPVC(SCH-80) pipe 200 mm dia bore in any length laid in trench/bore well and all jointed all as directed.
BLANK
External Water Supply: Cutting existing 150mm bore water mains and including inserting new Tee GI/CI/DI 150 mm x 150mm for taking branch connection, necessary fittings and joints complete all as directed .
Supply and lay pipe ductile Iron, S/S including specials, Class “K-9” ,150 mm (6”) dia complete all as specified and as directed .
Supply and lay pipe ductile Iron, S/S including specials, Class “K-9” ,100 mm (4”) dia complete all as specified and as directed .
Supply and lay pipe galvanized, “Medium grade”, including required necessary fittings of 63 mm(2.5") dia all as directed.
Supply installation testing and commissioning of manufactures factory assembled and testing electric driven centrifugal pump set of capable of discharge 300 LPM ( 5HP,415 Volt capacity) at head 30M, Bronze impeller , cast iron body inclusive of automatic starter Horizontal split casing pump multi stage coupled through a flexible coupling to a SPDP motor not less than 5 HP complete mounted on common MS Base plate frame and foundation of the pump set including PCC foundation , MS Bolts with nuts and anti vibration pads and all as specified and as directed by Engr-in- Charge.
Supply installation testing and commissioning of manufactures factory assembled and testing electric driven centrifugal pump set of capable of discharge 150 LPM at head 30M, Bronze impeller , cast iron body inclusive of automatic starter Horizontal split casing pump multi stage coupled through a flexible coupling to a SPDP motor 3000RPM complete mounted on common MS Base plate frame and foundation of the pump set including PCC foundation , MS Bolts with nuts and anti vibration pads and all as specified and as directed by Engr-in- Charge.
Supply and fix Cast Iron Air Valves with two air Outlets, 50 mm dia bore and fixing up in cast iron water supply mains complete all as specified and as directed .
M&L for Construction of new valve chamber of size 900x900x900mm with foundation cement concrete brick / bricks in cement mortar 1:6 , with PCC 1:4:8 type D2 sub base plaster internally and exposed external surface in cement mortar 1:4 (15 mm thick and provision of valve chamber cover made out of MS sheet 3.0 mm thick welded on angle iron frames 40 x 40 x 5 mm made out of double door type with hinges and locking arrangement duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer all as directed complete with good finishing.
All as per item No.62 above, but of size 600x600x600mm.
Supply and fix pressure gauge standard dia 4" dial 0-14 kgs rating including stop cock etc complete all as specified and directed by Engr-in-Charge.
Supply installation testing and commissioning of manufactures factory assembled and testing electric driven centrifugal pump set of capable of discharge 700 LPM ( 10 HP,415 Volt capacity) at head 30M, Bronze impeller , cast iron body inclusive of automatic starter Horizontal split casing pump multi stage coupled through a flexible coupling to a SPDP motor 2850 RPM not less than 10 HP complete mounted on common MS Base plate frame and foundation of the pump set including PCC foundation , MS Bolts with nuts and anti vibration pads and all as specified and as directed by Engr-in- Charge.
Supply installation testing and commissioning of manufactures factory assembled and testing electric driven centrifugal pump set of capable of discharge 350 LPM( 5 HP,415 Volt capacity) at head 30M, Bronze impeller , cast iron body inclusive of automatic starter Horizontal split casing pump multi stage coupled through a flexible coupling to a SPDP motor 2850 RPM not less than 5 HP complete mounted on common MS Base plate frame and foundation of the pump set including PCC foundation , MS Bolts with nuts and anti vibration pads and all as specified and as directed by Engr-in- Charge.
External Electric Supply: Supply, install, test and commissioning of transformer step down 200 KVA outdoor type Oil immersed, ONAN copper wound complete with all standard accessories, vector group DYN 11KV/0.415V suitable for continuous duty for operation on AC 3 phase, 50 HZ with off load Tap changer to vary secondary voltage ±7.5 % in steps of 2.5% including transformer oil upto appropriate level all as per IS 1180(Part-I) : 2014 (amendment No 4 Mar 2021) energy efficiency level-2, Max Losses at 50% Loading : 670 Watts and Max Losses at 100% Loading: 2100Watts, Impedance shall be 4.5%. - 01 No with energy efficiency level-2 and complete with and including PCC platform of size 1.50 Mtr x 1.50 Mtr x 1.20 Mtr (above GL) with the following fitting/accessories all as directed:-
[a] Conservator with oil filling hole, drain plug, oil level indicator. [b] Two nos earthing terminal. [c] Rating and diagram plate. [d] Air release plug. [e] Off load tap changer. [f] Silica gel breather. [g] Four nos Bi-directional rollers. [h] Drain cum filter valve . [j] Top filter valve. [k] Thermometer pocket. [l] Radiator with butterfly valves. [m] Explosion vent with single diaphragm. [n] HV cable box. [o] LV cable box. (P) Fencing , gate and other safety requirements as per IS 732 (1989) and IEC 60364 and all as specified and as directed by Engr-in- Charge. Note : - Necessary provision is required to entry box of transformer for LT cable 3.5 core 185 Sqmm single run on LT side and 3 core 95 sqmm cable on HT side including fixing arrangement in transformer with terminal box etc.
Supply, install, testing & commissioning of HT cubical/panel, 11 KV 630 amps, 25KA, IP 54 protection outdoor type consisting of 3 Nos load break switch floor mounted incoming - 1 No and out going - 2 Nos and equipped with earth switches, fuse tripping mechanism with 2 No+2 NC auxiliary contract. Spring charged mechanism manually operated with suitable HT HRC fuse mechanical ON/OFF indication, manual trip push button, control wing with appropriate colours, Bus connection 630 amps, aluminium busbar manually trip. Earth switch operating port, view glass earth switches interlock to prevent hazardous access to the fuse links MS sheet enclosure suitable for outdoor installation, lifting hook, provision for incoming/outgoing cables through bottom entry along with adopter extendable type including necessary PCC platform, operating handle, Fencing , gate and other safety requirements as per IS 732 (1989) and IEC 60364 and all as specified and as directed by Engr-in- Charge. all as directed.
(a) TPN MCB 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA, C curve, Incomer-1 No. (b) TP MCB 16 Amp, C type, 50 Hz, 415 V with rupturing capacity 10 KA C curve-3 Nos. (c) DOL starter 2HP -02 Nos . (d) Digital Volt meter (0-500 V)-1 No .(e) Digital Ammeter-01 No (f) CT's 100/5A - 03 Nos (g) LED type Indication lamps (RYB)-3 Nos (h) Fire detection & supression system (1 Kg Cylinder, Power supply indication panel 230V 50Hz AC, fire sniper tube-6mm outer dia, 4mm inner dia of adequate length)
(a) 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA, C curve (Incomer)-01 No. (b) 3 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA, C curve (standby power supply Panel Bldg)-01 No.(c) TP MCB 32 Amp, B type, 50 Hz, 415 V with rupturing capacity 10 KA -09 Nos. (d) Digital Volt meter (0-500 V)-01 No (e) Digital Ammeter-01 No.(f) CT's 400/5- set of 3Nos .(g) Fire detection & supression system (1 Kg Cylinder, Power supply indication panel 230V 50Hz AC, fire sniper tube-6mm outer dia, 4mm inner dia of adequate length)
M&L for Fabricate, supply ,install testing and commissioning of LT panel No 3 indoor type 415 Volts, 50 Hz, 3 phase, 4 wire for accommodating the following accessories totally enclosed self supporting structure fully compartmentalized suitable for indoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 2mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for aluminium bus bars 200 Amps capacity, hinged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following accessories suitable for incoming/outgoing arrangements complete all as specified and directed:-
(a) 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity 35 KA, Incomer -1 No.(b) 3 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA, (Fire Main Pump)-1 No (c) TPN MCB 32 Amp, C type,50 Hz, 415V with rupturing capacity 20 KA-4 No.(d) Star Delta Starter for 70HP (Fire Main Pump)-1No.(e) DOL Starter for 7.5HP (Jockey)-1No (f) Star Delta Starter for 5HP (water supply pump)-2No.(g) On load Changeover switch 25 Amps , 415v, 4pole,3Ph-1No.(h) Digital Volt meter (0-500 V)-01 No (j) Digital Ammeter-01 No.(k) CT's 200/5- set of 3 No.(l) LED type Indication lamps (RYB)-one set (m) Fire detection & supression system (1 Kg Cylinder, Power supply indication panel 230V 50Hz AC, fire sniper tube-6mm outer dia, 4mm inner dia of adequate length)
(a) 4 Pole MCCB 12- 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA-01No (stand by power supply Panel Bldg). (b) TP MCB 16 Amp, B type, 50 Hz, 415 V with rupturing capacity 10 KA (Terrace pump-2 Nos, Lift - Nos, Spare -1 No) -05 No. (c) Onload Chageover switch 63amps , 415v, 4pole,3Ph-01 Nos.(d) SP MCB 6 to 32 Amp, 50 Hz, 230 V with rupturing capacity 10 KA , B Curve-01 No.(e) Star Delta Starter for 15HP (Terrace pump)-2 No.(f) Digital Volt meter (0-500 V)-01 No (g) Digital Ammeter-01 No.(h) CT's 100/5- set of 3Nos .(j) LED type Indication lamps (RYB)-01 Set of three (k) Fire detection & supression system (1 Kg Cylinder, Power supply indication panel 230V 50Hz AC, fire sniper tube-6mm outer dia, 4mm inner dia of adequate length)
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-66 protection including suitable GI bracket complete all as directed.
Supply and fixing PVC pole mounted junction box with hinged door and single phase with neutral bus bar 63 Amps capacity 20x3.3mm size of strip fixed on insulator including 6-32 Amps MCB SP 'B' Curve, 10 KA rupturing capacity, drilling fixing on pole, thimbles (for street light) complete all as directed.
M&L for 3 core x 2.5 sqmm copper conductor, 1100 volt grade, PVC insulated, sheathed, copper conductor for street light fittings from junction box to street light fittings compete all as directed.
Supply and fix cable route indicator made out of 3 mm thick MS sheet of suitable size (As approved by Engr-in-charge) duly painted with two coats black paint over a coat of red oxide primer and writing cable direction, size of cable (in SQMM), type of cable (OFC/PVC/LT cable) with white paint, mounted on angle iron 40x40x3 mm, angle height 45 cm, (30cm below ground level) with and including PCC 20cmx20cmx15cm all as directed. E.E.S-40+Fire fighting-75
(a) MCCB 315 AMP 35KA 4 pole - 01 No(Incomer). (b) MCCB 200 AMP 35KA 3 pole - 01 No. (c) MCCB 125 AMP 35KA 3 pole - 01 No (d) MCB 6-32 AMP 10KA SP - 01 No(for area light ) . (e)Timer switch 250 volts, 20 Amps . (f) Aluminium bus bar 400 Amp (g) Digital Voltmeter (0-500)- 01 No (h) Digital Ammeter - 01 No. (j) LED Indicating lamp set -01 Set of three (k) CT of suitable ratio 400/5 A - Set of 3 Nos.(l) Fire detection & supression system (1 Kg Cylinder, Power supply indication panel 230V 50Hz AC, fire sniper tube-6mm outer dia, 4mm inner dia of adequate length)
(a) MCCB 200 AMP 35KA 4 pole - 01 No(Incomer). (b) MCCB 63 Apms, 16 KA, 3P- 01No. (c) MCB 32 Amps ,10KA , 3P, C curve - 09 No. (d) Aluminium bus bar 300 Amp (e) Digital Voltmeter (0-500)- 01 No. (f) Digital Ammeter - 01 No. (g) LED Indicating lamp set - 01 Set of three. (h) CT of suitable ratio 300/5A - Set of 3 Nos (j) Fire detection & supression system (1 Kg Cylinder, Power supply indication panel 230V 50Hz AC, fire sniper tube-6mm outer dia, 4mm inner dia of adequate length)
(a) MCCB 125 AMP 35KA 4 pole - 01 No (Incomer).(b) MCCB 100 AMP 25KA 3 pole - 01 No (c) MCB 32 AMP ,TP ,10KA - 04 No. (d) Star delta Starter 5 HP -2 No . (e) Star delta Starter 7.5 HP - 1 No. (f) Star Delta Starter 70 HP - 01 No (g) Onload Chage over switch 4 Pole, 125 Amps -01 No (h) Aluminium bus bar 200 Amp (j) Digital Voltmeter (0-500)- 01 No (k) digital Ammeter - 01 No . (l) LED Indicating lamp set -01 Set of three (m) CT of suitable ratio 200/5 A - Set of 3 Nos (n) Fire detection & supression system (1 Kg Cylinder, Power supply indication panel 230V 50Hz AC, fire sniper tube-6mm outer dia, 4mm inner dia of adequate length)
S&F LT panel No 4 indoor type 415 Volts, 50 Hz, 3 phase, 4 wire for accommodating the following accessories totally enclosed self supporting structure fully compartmentalized suitable for indoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 2mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for aluminium bus bars200Amps capacity, hinged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following accessories suitable for incoming/outgoing arrangements complete all as specified and directed:-
(a) MCCB 63 Amps 16KA, Four pole - 01 No(Incomer) (b) MCB 16 AMP , C curve, TP , 10 KA - 05 No (c) MCB SP 6 -32 Ams, 10 KA, C curve -1 No( lcommon area lighting ) (d) Onload change over switch 63 Apms , 4Pole-01 No . (e) Star Delta Starter 15HP -1 No (Terrace Pump) (f) Aluminium bus bar 100 Amp (g) Digital Voltmeter (0-500)- 01 No (h) digital Ammeter - 01 No (j) LED Indicating lamp set - 01 Set of three (k) CT of suitable ratio 200/5 A - Set of 3 Nos (l) Fire detection & supression system (1 Kg Cylinder, Power supply indication panel 230V 50Hz AC, fire sniper tube-6mm outer dia, 4mm inner dia of adequate length)
S&F LT panel indoor type 415 Volts, 50 Hz, 3 phase, 4 wire for accommodating the following accessories totally enclosed self supporting structure fully compartmentalized suitable for indoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 2mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for aluminium bus bars200Amps capacity, hinged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following accessories suitable for incoming/outgoing arrangements complete all as specified and directed:-
(a) MCB 32 AMP 4 Pole, 10KA , C curve - 01 No(Incomer) (b) MCB 16 AMP 10KA, 3P, C curve - 03 No (out going for water Pump 5 HP & one spare) (c) DOL Starter 10 HP - 2 No (fresh water pump) (d) Aluminium bus bar 100 Amp (e) Digital Voltmeter (0-500)- 01 No (f) digital Ammeter - 01 No (g) LED Indicating lamp set -01 Set of three (h) CT of suitable ratio 100/5 A - Set of 3 Nos (j) Fire detection & supression system (1 Kg Cylinder, Power supply indication panel 230V 50Hz AC, fire sniper tube-6mm outer dia, 4mm inner dia of adequate length)
BLANK
BLANK
Fire fighting/Alarm System:- M& L for boring of holes under road, pavement, hard standing by using trenchless technology with and including HDPE pipe of 50 mm dia suitable for 0.4 mpa working pressure complete all as directed.
Supply, Installation, testing and commissioning of 50mm dia automatic air release valve with double ended complete with unions and all necessary accessories all as directed.
Supply and fix Fire Alarm control panel complying with BS EN54 two loop addressable peer to peer networkable analogue addressable type with minimum 1500 character/240x64 pixel/7 inch touch screen graphics LCD display, keypad, dual flash based microprocessor technology, inbuilt USB port for upload and download the configuration tools, RS232 series port for direct PC or modem connection, inbuilt NAC's minimum 20 programmable zonal LEDs and operate on 240V AC + 10%, 50 Hz with build in charger suitable for 99 detectors, & 99 modules & upto 240 detectors and modules per loop, suitable for minimum of 5000 event record facility complete all as directed . Make : IBL/Halma/Noveltech. Note : The rates of panels deemed to be included necessary cards, modules, panel enclosure, CPU and connected accessories to complete the system.
Supply and fix fault tolerance Network card for Fire Alarm control panel, fault tolerance the network operates as a true peer to peer system and allow information from any input or output device to be passed over the network and displayed on any axis EN control panel or remote terminal as required complete all as directed. Make : IBL/Halma/Noveltech.
Supply & Laying of 2 Core, 1.5 Sqmm Un-armoured PVC insulated & sheathed copper flexible cable complete all as directed.
Supply & Laying of 25 mm dia PVC conduit red colour complete all as directed.
Supply and fix Ad-Net/Fiber optic convertor single mode for optic fiber cable complete all as directed.
Supply and laying of 6 fibler single mode, armoured, ISO/IEC-11801, EN50173, ANSI/TIA-586-C3, fire optic cable complete all as directed.
Supply and laying HDPE Pipe 25mm dia complete all as specified and directed for OFC cables complete all as directed.
Supply, Installation, Testing & Commissioning of remote controlled terminal fault tolerant (Repeater Panel) complete all as specified and as directed by Engr-in-Charge. Make : IBL/Halma/Noveltech.
Supply, installation, testing & commissioning of 8 zones system controller Panel with built-in DVR, having priority facility, music and Pre recorded fire evac message.Controller can be extended upto 100 zones complete all as directed.
Supply installation, testing & commissioning of 8 zone Call Station keypad with for PA system Announcement with goose neck microphone and with LCD display to announce all the zones or individual zones complete all as directed. Make : IBL/Halma/Noveltech (PA System controller panel).
Supply & Laying of 4 Core 1.5 Sqmm Un-armoured cable complete all as directed .
Note : (i) Each shift have one operator. The operator shall be employed by the contractor must be of proper trade i.e duly Govt ITI qualified with relevant field experience. (ii) The contractor shall take over the installation from the department alongwith serviceability state of plant details of the installation in writing one day before starting the contract. (iii) The shift Operator shall not leave the installation without handing over to the next shift operator. (iv) The contractor shall provide stationeries like logbook, pen, pencil, cotton waste and conveyance for tradesmen and any other items required for day to day work. (v) The operator should clean the installations and installation area on every day. If the operator fails to clean the installations and surrounding area, penalty of Rs 500/- day will be deducted from the contracted amount. (vi) Necessary log book entries shall be maintained by the operator in each shift. Necessary handing taking over details between the shift operator shall also reflected in the log books. (vii) The contractor shall provide one Non camera phone with valid sim per installation for communicating with the concern Engr-in-charge and JE of the department. (viii) The operator should assist the department personnel for collecting and distributing the diesel engine oil/coolant etc to avoid any delay in day in day function. (ix) If the operator is found absent in any of the shift and the plant is not run at all in the shift, a penalty of double rate of per shift salary will be imposed on the contractor and will be deducted from his dues. (x) Contractor has to consider minimum wages act enacted by Govt of India. The tender shall be rejected if the tenderer quoted the rates below the minimum wages.
Note for serial item No. 101 to 103: (i) Each shift have one operator. The operator shall be employed by the contractor must be of proper trade i.e duly Govt ITI qualified with relevant field experience. (ii) The contractor shall take over the installation from the department alongwith serviceability state of plant details of the installation in writing one day before starting the contract. (iii) The shift Operator shall not leave the installation without handing over to the next shift operator. (iv) The contractor shall provide stationeries like logbook, pen, pencil, cotton waste and conveyance for tradesmen and any other items required for day to day work. (v) The operator should clean the installations and installation area on every day. If the operator fails to clean the installations and surrounding area, penalty of Rs 500/- day will be deducted from the contracted amount. (vi) Necessary log book entries shall be maintained by the operator in each shift. Necessary handing taking over details between the shift operator shall also reflected in the log books. (vii) The contractor shall provide one Non camera phone with valid sim per installation for communicating with the concern Engr-in-charge and JE of the department. (viii) The operator should assist the department personnel for collecting and distributing the diesel engine oil/coolant etc to avoid any delay in day in day function. (ix) If the operator is found absent in any of the shift and the plant is not run at all in the shift, a penalty of double rate of per shift salary will be imposed on the contractor and will be deducted from his dues. (x) Contractor has to consider minimum wages act enacted by Govt of India. The tender shall be rejected if the tenderer quoted the rates below the minimum wages.
Comprehensive maintenance of Passenger Lift of Capacity 544Kgs of 08 Passengers - 02 Nos (Office Md accn - 01 No and at JWO Md accn -01 No) for G+7 storey during the first year after Defects liability period : - To carry out periodical Maintenance once 30 days which Includes checking of Cables, gear, speed Governor, Gear Oil etc
Comprehensive maintenance of Passenger Lift of Capacity 884 Kgs of 13 Passengers - 02 Nos (Office Md accn - 01 No and at JWO Md accn -01 No) for G+7 storey during the first year after Defects liability period : - To carry out periodical Maintenance once 30 days which Includes checking of Cables, gear, speed Governor, Gear Oil etc.
Comprehensive maintenance of Passenger Lift of Capacity 544Kgs of 08 Passengers - 02 Nos (Office Md accn - 01 No and at JWO Md accn -01 No) for G+7 storey during the second year after Defects liability period : - To carry out periodical Maintenance once 30 days which Includes checking of Cables, gear, speed Governor, Gear Oil etc
Comprehensive maintenance of Passenger Lift of Capacity 884 Kgs of 13 Passengers - 02 Nos (Office Md accn - 01 No and at JWO Md accn -01 No) for G+7 storey during the second year after Defects liability period : - To carry out periodical Maintenance once 30 days which Includes checking of Cables, gear, speed Governor, Gear Oil etc.
Comprehensive maintenance of Passenger Lift of Capacity 544Kgs of 08 Passengers - 02 Nos (Office Md accn - 01 No and at JWO Md accn -01 No) for G+7 storey during the third year after Defects liability period : - To carry out periodical Maintenance once 30 days which Includes checking of Cables, gear, speed Governor, Gear Oil etc
Comprehensive maintenance of Passenger Lift of Capacity 884 Kgs of 13 Passengers - 02 Nos (Office Md accn - 01 No and at JWO Md accn -01 No) for G+7 storey during the third year after Defects liability period : - To carry out periodical Maintenance once 30 days which Includes checking of Cables, gear, speed Governor, Gear Oil etc.
Note for serial item No.104 to 109:- The work includes 11 services per annum and also any number of break downs in a year to be attended and rectified by the contractor. SCOPE OF WORK (a) Any part of the lift to be replaced whenever and where ever Necessary on normal wear and tear of the parts on free of cost. (b) Gear Oil, Gears, Bearings of Motor to be replaced whenever necessary and lubrication as the said parts to be carried out by the contractor at his own cost. (c) All electrical and mechanical parts of the lift to be checked, cleaned and lubricated to keep the lift in perfect working condition. CONDITIONS (a) Any part or in whole the lift may not be repaired if it is damaged, broken due to accident, due to misuse, willfully or negligence. (b) The following Works/Repairs are also within the scope of work :- (i) Refinishing/Painting (ii) Non-proprietary items of the lift equipments like Car enclosures, Car flooring, Hoist way enclosure, Hoist way and Car door, Door and gate handles, Door bearings, Door frames, sills push box covers in landings, Car buzzer, Emergency light, Alarm device and Batteries. (iii) Any Works/ Services/Repairs which are required to make the lift in serviceable if not considered in the scope of work but necessary to make the lift in serviceable as per recommendation of the OEM will be carried out for which no extra cost has to be paid in addition to the contract charges. Note : Old unserviceable/Retrieved Material are to be handed over to the department.
C R R CONSTRUCTIONS (BID ID -3146805)
N RAJEGOWDA and CO (BID ID -3147311)
SHRUSTI CONSTRUCTIONS (BID ID -3145825)
AFSON ENGINEERS & CONTRACTORS (BID ID -3146542)
CHHABINDRA KUMAR PRADHAN (BID ID -3146565)
Sukhdevraj Sharma Engineers & Contractors Pvt Ltd (BID ID -3141186)
SOOD ASSOCIATES PVT LTD (BID ID -3147053)
PROSPECTS INFRA PVT LTD (BID ID -3144509)
Jeet Construction (BID ID -3146665)
SREEKRISHNACONSTRUCTIONS (BID ID -3141952)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid