Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC NO 23 SECOND MAIN ROAD RAJAMMAL NAGAR MADAMBAKKAM CHENNAI 600 126 | CHENNAI | CHENGALPATTU | TAMIL NADU | 600126 | L1 | Accepted-AOC FULL FILL THE CONDTION OF CA | |
| 2 | L2₹24.6 L+₹4.4 L (21.5%)Rejected-Finance D NO 5 13 24 1 BEHIND SAHUWALA CYLINDERS IDA AUTONAGAR VISAKHAPATNAM 530 012 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | L2 | Rejected-Finance Rejected being not the lowest |
Tender Value
₹19.1 L
EMD Value
₹38,160
Closing Date
13 Apr 2020, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I)(CG) Military Engineer services Second Floor CG DHQ No 5(TN) No 4 and 4 A Clive Battery complex Rajaji Salai Chennai 600001
REPAIR AND ROUTINE MAINTENANCE OF ELECTRIC LIFTS INSTALLED AT CHENNAI AREA UNDER GE (I) (CG) CHENNAI
2019_MES_297445_1
8739/GE(I)(CG)
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Garrison Engineer (I)(CG) Chennai
All as per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹38,160
Yes
19 Nov 2020
19 Mar 2020
17 Apr 2020
19 Mar 2020
13 Apr 2020
26 Mar 2020
Amount
SCHEDULE 'A' - PART I (MAINTENANCE)
Comprehensive maintenance and repairs including renewal/ replacement of defective parts including Automatic Rescue Device (ARD) of electrically operated goods lift make OTIS Lifts with a capacity of 2000 Kgs for 3 stops/ 3 landings 0.50 M/Sec speed Thyristoried dual push button control system service ground floor and two upper floors installed at Coast Guard Royapuram Store Depot Chennai (Royapuram Store Depot). (01 No Lift) Serial No/SM MES No: MES 850/7013- LF/1/05, MES 850/7013LF/EM-1/05
Comprehensive maintenance and repairs including renewal/ replacement of defective parts including Automatic Rescue Device (ARD) and Over Load Warning Device (OLWD) at Bldg No - 7B where available of electrically operated passenger lift make M/s SUPRIYA ELEVATORS with a capacity of 6 passengers 408 Kgs for 4 stops / 4 landings, 0.65 M/Sec per single speed single push button control system with micro processor control system (152 flats Ragamalika Mogappair west ) ( 07 No lifts) ground floor and three upper floors. Serial No/SM No Building No 7 (A) : 850/7001-LF/03B and 850/7001-LF/EM-01/03 LIFT MOTOR, Building No 7(B) : 850/7002-LF/03B and 850/7002-LF/EM-01/03 LIFT MOTOR, Building No 8: 850/7003-LF/03B and 850/7003-LF/EM-01/03 LIFT MOTOR, Building No 10 (A) : 850/7004-LF/03B and 850/7004- LF/EM-01/03 LIFT MOTOR, Building No 10 (B) : 850/7005-LF/03B and 850/7005-LF/EM-01/03 LIFT MOTOR Building No 11 (A) : 850/7006-LF/03B and 850/7006-LF/EM-01/03 LIFT MOTOR, Building No 11 (B) : 850/7007-LF/03 B and 850/7007-LF/EM-01/03 LIFT MOTOR.
All as per Item No :3 here in before and including Automatic Rescue Device (ARD) and Over Load Warning Device (OLWD) at Bldg No 9 make M/s JAYABHARATH LIFTS ( 152 flats Mogappair west ) ( 01 No lift) Serial No/ SM No : SM No : 850/7008-LF/03B and 850/7008-LF/EM-01/03 LIFT MOTOR.
Note for item No 2 to 4 : (i) The spares/electrical items as listed in Sch 'A' Part II will be used whenever required only and measured and paid separately under respective items. (ii) The rate is inclusive of all items as required at site except those items given in Sch 'A' Part II to keep the lift operational round the clock including cleaning and greasing of all moving parts on monthly basis. (iii) If spare parts of original make is not available in the market , necessary suitable spare equivalent to existing lift part as approved by Engr-in-charge shall be used in the work so that lift will function smoothly . (iv) Cost of renewal of lift license by lift inspector from state Govt is deemed to be included in the quoted rate against Sl No 2 to 4 mentioned above.(v) Test certificate of each lift issued by Electrical Lift Inspector shall be produced,within three months from the date of commencement of work
SCHEDULE 'A' - PART II ( SPARE PARTS)
Supply only controller transformer - (0-440V)/(0-230 /110 /24/12V ) Make - Power tech or equivalent as approved by GE.
Supply only Main contactor 40A, 230V, 50HZ in the lift controller for display Make - Power tech/ TC or equivalent as approved by GE
Rewinding of magnetic brake coil 110V DC
Rewinding of main motor 5 /7.5 HP, 440V, 50HZ, 32A, 1.5 0m/sec to 0.65 m /per sec speed.
Rewinding of main motor 17.5 / 20 HP, 440V, 50HZ, 32A, 1.50m/sec to 0.65 m per sec speed.
Rewinding of door motor (110V-24V) AC
Rewinding of RCR coil
Supply only limit switches
Supply only auxillary relay 4A/9A 24V AC/DC Make : OEN
Supply only gate lock assembly for manually operated door
Supply only 4 Relay Board
Supply only Over load relay 440V, 40A/32A/16A suitable for 5HP/7.5HP/10HP 3 Phase motor.
Supply only Shoe liner 10 mm thick.
Supply only Door slipper
Supply only Main suspension Rope - 13 mm dia. Make - Usha Martin or equivalent as approved by GE
Supply only Over Speed Governer Rope - 8mm dia. Make - Usha Martin or equivalent as approved by GE.
Supply only thrust bearing for main gear box shaft. Make : SKF/ NBC
Supply and fix Travelling Cable 12 Core 0.5 sq.mm 1100V grade. Make : Macrotherm
Supply only Mother Board - Down Collective, Make - Power tech or equivalent as approved by GE.
Supply only 8 Relay Board
Supply only PF & RR Card 230V 50 HZ 15 A Make : Power Tech or equivalent as approved by GE.
Supply only lift fan 12" 230V 900 RPM. Make - Khaitan / Bajaj
Supply only emergency LED Light with inverter unit (rechargeable battery) 12V, 7AH for 2 hrs power back up. Make : Power Tech or equivalent as approved by GE.
Supply only position indication card suitable to work in 24 V for landing and car.
Supply only brake liner 5mm thick
Supply only lift LED light fittings 3 Watt. Make - Wipro / Philips /Surya
Supply only door operating buzzer 230V, 50HZ AC or 12/24 VDC. Make - Power tech or equivalent as approved by GE.
Supply only MS Maintenance box with Up/Down Push button, Lamp holder and 5 Pin socket of size 190 x 125 x 50 mm
Supply only door sill for collapsible gate / Auto door (120mm x 800mm)
Supply only Emergency alarm 230V AC/12V DC.
Supply only reed switches 230V AC (or) 24 VDC
Supply and fix lift car flooring , vinyl tiles 2mm thick fixed as per manufacturers instruction and as directed by GE.
Supply only guide shoes for car guide
Supply only guide shoes for counter weight
Supply only Variable Voltage Variable Frequency (VVVF) drive main suitable for 5.0 HP motor including software & necessary programming after fixing. Make : Fuji/ Toshiba/ Yasakawa
Supply only Variable Voltage Variable Frequency (VVVF) drive main suitable for 7.50 HP motor including software & necessary programming after fixing. Make : Fuji/ Toshiba/ Yasakawa
Supply only collapsible door of existing size (1650 mm width x 2000 mm height)
Supply only Imperforated door (IFG) of size (800mm width x 2000mm height)
Supply only ARD mother board Make - Power tech or equivalent as approved by GE.
Supply only ARD Transformer (0-20.8 Volt) / (0-440 Volt) for up to 20 HP
Supply only ARD Battery 12V 12 AH Make : Exide
Supply only ARD Battery 12V 7AH Make : Exide
Supply only over load warning device .
Supply only operating panel (COP)
Supply only landing operating panel (LOP)
Material and labour for Painting of lift car with two coats of anticorrosive black paint over a coat of red oxide primer including applying two coats of paster blue paint , inside and outside of sliding / IFG doors with synthetic enamel paint (ICL Dulux brand) duly approved by Engr-in-Charge complete all as specified and as directed.
INDUSTRIAL ENGINEERING SYSTEMS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .