Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
9 Dec 2019, 4:00 pmClosed
Executive Engineer Electric SKIMS Soura
Executive Engineer Electric SKIMS SOura
Renovation Up-gradation of electric system which includes replacement of worn-out damaged wiring, safety devices various types of fans, lighting fixtures by new LED and geysers cabling in OPD Block ground floor and 1st floor at SKIMS MCH Bemi
2019_SKIMS_86439_1
eNIT SIMS HEE EET 15 of 2019-20 Dt.20.11.2019
Open Tender
Electrical Works
Item Rate
30 days
SKIMS MCH Bemina
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
CAO SKIMS MCH Bemina
₹37,000
Yes
2 Mar 2020
22 Nov 2019
12 Dec 2019
22 Nov 2019
9 Dec 2019
22 Nov 2019
Amount
Providing and fixing of Led 4 feet long batten 6000/6500k Light having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driver CRI greater than 80 with minimum sytem lumens 2000 and maximum wattage 20 including connection with multistrand copper conductor 3 core cable etc as required at site.(Philips/ zumbtobel /Trilux make)
Providing and fixing of Led 2 feet long batten 6000/6500k Light having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driver CRI greater than 80 with minimum sytem lumens 1300 and maximum wattage 12 including connection with multistrand copper conductor 3 core cable etc as required at site.(Philips /zumbtobel /Trilux make)
Providing and fixing of bakelite /phenlic sheet 3mm thick against damaged and for inspections holes of various sizes required at site. complete in all respects at site
Providing and fixing of laminated ply board 6mm thick suitable color match with existing ceiling of ENT ward to be fixed in existing place of Miror optic light 4 feet long double 15"x 54"x 36 nos required at site. complete in all respects at site.
P/F F/T 5 pin socket 6 amps (SSK /Havell's Reo make)
P/F F/T Switch 6 amps (SSK / Havell's Reo make)
P/F Fan dimmer Stepped type (SSK / Havell's Reo make)
P/F 5 pin Switch/ Socket combine 16 amps F/T (SSK / Havell's Reo make)
Providing and fixing Exhaust fan 250 mm sweep with plastic shutter complete (Havell's/ Bajaj/Crompton make) against damaged one.
Providing and fixing of Ply board 12mm thick suitable size with making of central hole for fixing of above mentioned exhaust fans complete with civil works for exhaust fans. Average Siz 15 " X 15 "or requried size as per site requriment
Providing and fixing of celling fans 1200 mm sweep ( Havells / crompton / Bajaj) make new creation and against nonfunctional/damaged The job includes cost of fixing of iron hook suitable size & connecting wire 2 core as required.
Providing, fixing of fresh lighting point (5-6 amp) exposed,using PVC in double locked PVC channel 25x1.6 mm thick or PVC conduit 1" dia 1.5 mm thick with accessories to be fixed on the surface of the wall with rowel plugs, saddles, screws, using multi-strand 3 x1.5 mm sq. pvc insulated copper wire (P+N+E) (Havells/Finolex/ Polycab/Paramount make FR) complete with P/F of switch 5/6 amps F/T (SSK/Havell's Reo make) to be fitted on 3mm Bakelite sheet suitable size,M.S/Wooden box, rowel plugs & screws etc. complete Point.( D.G Power Supply points )
Wiring for 16 amps power points using FR PVC insulated copper conductor , multistrand core cable 3 X 2.5 sq mm (P+N+E) (Havells make) in surface PVC cassing as required with P/F of 16/amp Switch and Socket comb.(Havell's reo make), bakelite sheet,wood or iron box ete. complete in all respects at site. .( D.G Power Supply points )
Supply & laying circuit wire FR PVC insulated copper conductor , single core cable 3 X 4 sq mm (P+N+E) in the existing surface/ recessed conduit as required for Fresh light point circuit and 16/amp power points. (Havells/polycab/ Finolex make) ( single wire)
Same as item no 14 but 2.5 sq. mm for light points.
Same as item no 14 but 6 sq. mm for sub main circuits
P/F Double locked pvc channel 25x 2mm with allied accessories.
P/F Flixable PVC pipe 1" dia
P/F 25 mm dia ISI marked pvc conduit 2 mm thick complete with bends, raval plugs, saddles etc.
Providing, laying,testing and commissioning of Al. cable 3.5 core 35 sq. mm XLPE PVC insulated, armoured,sheathed for indiual power supply to IT department from Main substation to sub DB IT deptt. Complete with P/F of iron clips, raval plugs and screws etc. The cable should be layed on existing iron hanger over head cable bridge and walls. complte job as per site requirement. (For Induual power supply to IT department )
Providing andmaking of end termination of above cable 35 sq. mm 3.5 core complete with thimbling, crimping,taping, connecting and testing.( For IT )
Providing and fixing of MCCB enclosure 4 pole metalic 16 SWG thick ( for fixing of above mantioned 63 A MCCB TPN ) size 1.5 x1.5'x1' complete wih painting, gland houles, hinged type, lockable door with painting to be fixing on wall. Complete with civil work at site. (01 Nos )
Providing and fixing of MCCB 63/ 100 amps TPN 25kA B/ capacity Legrand/Schneider acti-9/ Siemens make.( one MCCB to fixed in main substation panel and one in IT deptt. As main )
Supplying and fixing 12 way, single pole and neutral, sheetsteel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper insulated bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (SSK/Havells/Honeywell/Schneider make)
P/F of MCB TPN 63 amps 10 KA "C" curve (Legrand/Schneider acti-9/siemens ) for existing DB against isolater.
P/F of MCB TPN 40 amps 10 KA "C" curve (Legrand/Schneider acti-9/siemens) for existing DB.
P/F of MCB SP 6 to 32 amps 10 KA "C" curve (Legrand/Schneider acti-9/siemens) for existing DB.
Providing and laying of spans of 3 ½ core/2 core PVC insulated Al. cable Armoured of 25 sq. mm sizes as mentioned below in place of low capacity/damaged/burnt out wires. From power control room OPD to sub DB's of OPD Block Ground & first.(Polycab/Gloster Skytone/Paramount make)
Providing and laying of fresh 6/8 SWG G.I bear wire for earthing from power control to sub DB's both ground and first floor OPD.
Providing and making of end termination of the 25 sq. mm 3 ½ LT cable including Thimbling, crimping tapping, testing and connecting as per site requirements (dowels/3D make)
Providing and laying of span of 3.5 core PVC insulated Al. Cable armoured of 185 sq. mm size as main complete clamped with saddles on wall etc. ( fresh ones from main substation upto power control room CT scan (Polycab/Gloster/Skytone/Paramount make)
Providing and making of end termination of the 185 sq. mm 3 ½ LT cable including Thimbling, crimping tapping, testing and connecting as per site requirements (dowels/3D make)
Providing and fixing of fresh Changeover switch with advance Neutral 4 pole 400 amp ON load changeover switch with Enclosure to be fixedin power control room CT Scan complete in all respects at site (Havell's/Crompton/L&T make) for above cable 185 sq. mm/ existing cable.
Providing and fixing 250 amp rating and breaking capacity 36 KA and four pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.. (Legrand /Hager/ Schiender NSX/Siemens(3VL)/ABB make ) ( with Adjustable range from .7 to1) in L.T Panel of X-Ray and C.T Scan
K.J. Enterprises
M/S BHAT ELECTRICALS
M/s BILAL ELECTRIC GOODS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .