Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC RADHA NIKUNJ L 2 SOUTH CIVIL LINES ROORKEE HARIDWAR UTTARAKHAND 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹31.9 L+₹3.0 L (10.4%)Rejected-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹32.1 L+₹3.2 L (11.1%)Rejected-AOC 4 94D RAJA COTTAGE 1ST FLOOR KANYAKULAM PARVATHIPURAM NAGERCOIL KANNIYAKUMARI TAMILNADU 629 003 | KANNIYAKUMARI | TAMIL NADU | 629003 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹32.6 L+₹3.7 L (12.8%)Rejected-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹33.2 L+₹4.3 L (15.0%)Rejected-AOC 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L5 | Rejected-AOC Not Lowest |
| Sl No | Description | Qty | Unit | GS TRADERS L7 | Shiva Shakthi Electrical Enterprises L2 | Rama Electricals L4 | Vasavi Electricals L5 | RRK PROJECTS L8 | NRN GROUP L6 | EX SOLDIERS MECHANICAL WORKS L1 | ADR ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installtion,testing commisioning of LT panel, CPRI approved out door type of size not less than 1300x500x1900mm, platform mounted, totally enclosed, dust and vermin proof, openable from both- front and rear side, made out of 3.15 mm thick CRCA sheet including inner chambers/partitions to mount the following electrical accessories with angle iron 75x75x6mm frame work, having front & rear hinged doors, lifting lugs (2 Nos), provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The entire panel including cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Aluminium strip of suitable size and necessary grouting/ foundation all as required at site including dismantling and taking down of old unsv panel complete all as specified & directed :- | 4 | Each Job | 2,40,000 ₹9,60,000 | 2,14,999 ₹8,59,996 | 2,34,407 ₹9,37,628 | 2,68,000 ₹10,72,000 | 2,58,000 ₹10,32,000 | 2,65,440 ₹10,61,760 | 1,95,000 ₹7,80,000 Lowest | 2,45,400 ₹9,81,600 |
| 1.01BUS BAR - Aluminium bus bar system of capacity 600 amp four pole duly colour coded. INCOMER - MCCB, 4 pole of capacity 400 amps with breaking capacity of 36 KA . - 01 No. Outgoing - (a) MCCB, 4 pole of capacity 250 amps with breaking capacity of 25 KA . - 01 No. (b) MCCB, 4 pole of capacity 160 amps with breaking capacity of 25 KA . - 02 No. (c) MCB, 4 pole of capacity 32 amps with breaking capacity of 10 KA . - 02 No. (d) MCB, 4 pole of capacity 63 amps with breaking capacity of 10 KA . - 01 No. (e) MCB, 4 pole of capacity 6 amps with breaking capacity of 10 KA . - 01 No. (f) Timer switch and contactor for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates. Nos-01 (g) Digital multimeter - 01 No (h) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three | |||||||||||
| 2.00 | Supply, installtion,testing commisioning of LT panel, CPRI approved out door type of size not less than 1300x500x1900mm, platform mounted, totally enclosed, dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA sheet including inner chambers/partitions to mount the following electrical accessories with angle iron 75x75x6mm frame work, having front & rear hinged doors, lifting lugs 2 Nos, provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Aluminium strip of suitable size and necessary grouting/ foundation all as required at site including dismantling and taking down of old unserviceable panel complete all as specified & directed :-
'BUS BAR - Aluminium bus bar system of capacity 600 amp four pole duly colour coded.
INCOMER - MCCB, 4 pole of capacity 400 amps with breaking capacity
of 36 KA . - 01 No.
Outgoing -
(a) MCCB, 4 pole of capacity 250 amps with breaking capacity
of 25 KA . - 01 No. Contd... | 4 | Each Job | 2,58,000 ₹10,32,000 | 2,34,999 ₹9,39,996 | 2,30,985 ₹9,23,940 | 2,45,000 ₹9,80,000 | 2,78,000 ₹11,12,000 | 2,75,120 ₹11,00,480 | 2,15,000 ₹8,60,000 Lowest | 2,76,100 ₹11,04,400 |
| 2.01(b) MCCB, 4 pole of capacity 160 amps with breaking capacity of 25 KA . - 02 No. (c) MCCB, 4 pole of capacity 100 amps with breaking capacity of 25 KA . - 01 No. (d) MCCB, 4 pole of capacity 63 amps with breaking capacity of 25 KA . - 01 No. (e) MCB, 4 pole of capacity 32 amps with breaking capacity of 10 KA . - 02 No. (f) MCB, 4 pole of capacity 63 amps with breaking capacity of 10 KA . - 01 No. (g) MCB, 4 pole of capacity 6 amps with breaking capacity of 10 KA . - 01 No. (h) Timer switch and contactor for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates. Nos-01 (j) Digital multimeter - 01 No (k) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three | |||||||||||
| 3.00 | Supply, installtion,testing commisioning of LT panel, CPRI approved out door typeof size not less than 1300x500x1900mm, platform mounted, totally enclosed, dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA sheet including inner chambers / partitions to mount the following electrical accessories with angle iron 75x75x6mm frame work, having front & rear hinged doors, lifting lugs 2 Nos, provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Aluminium strip of suitable size and necessary grouting/ foundation all as required at site including dismantling and taking down of old unserviceable panel including replacement of lugs for incoming / outgoing cables as per existing all as specified & directed :- | 4 | Each Job | 2,46,000 ₹9,84,000 | 2,15,999 ₹8,63,996 | 2,12,164 ₹8,48,656 | 2,10,000 ₹8,40,000 | 2,48,000 ₹9,92,000 | 1,74,740 ₹6,98,960 | 1,85,000 ₹7,40,000 | 1,68,700 ₹6,74,800 Lowest |
| 3.01BUS BAR - Aluminium bus bar system of capacity 300 amp four pole duly colour coded. INCOMER - MCCB, 4 pole of capacity 250 amps with breaking capacity of 36 KA . - 01 No. Outgoing - (a) MCCB, 4 pole of capacity 160 amps with breaking capacity of 25 KA . - 01 No. (b) MCCB, 4 pole of capacity 100 amps with breaking capacity of 25 KA . - 02 No. (c) MCCB, 4 pole of capacity 63 amps with breaking capacity of 25 KA . - 02 No. (d) MCB, 4 pole of capacity 32 amps with breaking capacity of 10 KA . - 02 No. (e) MCB, 4 pole of capacity 63 amps with breaking capacity of 10 KA . - 01 No. (f) MCB, 4 pole of capacity 6 amps with breaking capacity of 10 KA . - 01 No. (g) Timer switch and contactor for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates -01No (j) Digital multimeter - 01 No (k) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three | |||||||||||
| 4.00 | Supply, installtion,testing commisioning of LT panel, CPRI approved out door type of size not less than 1900x1300x500mm, platform mounted, totally enclosed, dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA sheet complete including inner chambers/partitions to mount the following electrical accessories with angle iron 75x75x6mm frame work, having front & rear hinged doors, lifting lugs 2 Nos, provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Aluminium strip of suitable size and necessary grouting/ foundation all as required at site including dismantling and taking down of old unserviceable panel including replacement of lugs for incoming / outgoing cables as per existing all as specified & directed :-
BUS BAR - Aluminium bus bar system of capacity 300 amp four pole duly colour coded.
INCOMER - MCCB, 4 pole of capacity 160 amps with breaking capacity
of 36 KA . - 01 No.
Outgoing -
(a) MCCB, 4 pole of capacity 100 amps with breaking capacity of 25 KA . - 01 No.
(b) MCCB, 4 pole of capacity 63 amps with breaking capacity of 25 KA . - 02 No. contd... | 3 | Each Job | 1,90,000 ₹5,70,000 | 1,75,999 ₹5,27,997 | 1,83,077 ₹5,49,231 | 1,44,000 ₹4,32,000 Lowest | 2,16,500 ₹6,49,500 | 1,71,832 ₹5,15,496 | 1,70,000 ₹5,10,000 | 1,50,300 ₹4,50,900 |
| 4.01(c) MCB, 4 pole of capacity 32 amps with breaking capacity of 10 KA . - 02 No. (d) MCB, 4 pole of capacity 63 amps with breaking capacity of 10 KA . - 01 No. (e) MCB, 4 pole of capacity 6 amps with breaking capacity of 10 KA . - 01 No. (f) Timer switch and contactor for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates. Nos-01 (g) Digital multimeter - 01 No (h) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three | |||||||||||
Tender Value
₹38.4 L
EMD Value
₹76,700
Closing Date
12 Mar 2026, 6:00 pmClosed
CWE (ARMY) BANGALORE
CWE (ARMY) BANGALORE, 101 DICKENSION ROAD, BANGALORE-560042
SPECIAL REPAIR/ REPLACEMENT OF OLD UNSERVICEABLE PANEL AT ARMY UNITS UNDER GE (NORTH) BANGALORE
2026_MES_753282_1
86517/E8
Open Tender
Civil Works
Item Rate
180 days
CWE (ARMY) BANGALORE
AS PER TENDER
8 documents required · 8 mandatory
₹500
GE (NORTH) BANGALORE
₹76,700
21 May 2026
19 Feb 2026
19 Mar 2026
19 Feb 2026
12 Mar 2026
5 Mar 2026
19 Feb 2026 - 26 Feb 2026
Supply, installtion,testing commisioning of LT panel, CPRI approved out door type of size not less than 1300x500x1900mm, platform mounted, totally enclosed, dust and vermin proof, openable from both- front and rear side, made out of 3.15 mm thick CRCA sheet including inner chambers/partitions to mount the following electrical accessories with angle iron 75x75x6mm frame work, having front & rear hinged doors, lifting lugs (2 Nos), provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The entire panel including cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Aluminium strip of suitable size and necessary grouting/ foundation all as required at site including dismantling and taking down of old unsv panel complete all as specified & directed :-
BUS BAR - Aluminium bus bar system of capacity 600 amp four pole duly colour coded. INCOMER - MCCB, 4 pole of capacity 400 amps with breaking capacity of 36 KA . - 01 No. Outgoing - (a) MCCB, 4 pole of capacity 250 amps with breaking capacity of 25 KA . - 01 No. (b) MCCB, 4 pole of capacity 160 amps with breaking capacity of 25 KA . - 02 No. (c) MCB, 4 pole of capacity 32 amps with breaking capacity of 10 KA . - 02 No. (d) MCB, 4 pole of capacity 63 amps with breaking capacity of 10 KA . - 01 No. (e) MCB, 4 pole of capacity 6 amps with breaking capacity of 10 KA . - 01 No. (f) Timer switch and contactor for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates. Nos-01 (g) Digital multimeter - 01 No (h) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three
Supply, installtion,testing commisioning of LT panel, CPRI approved out door type of size not less than 1300x500x1900mm, platform mounted, totally enclosed, dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA sheet including inner chambers/partitions to mount the following electrical accessories with angle iron 75x75x6mm frame work, having front & rear hinged doors, lifting lugs 2 Nos, provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Aluminium strip of suitable size and necessary grouting/ foundation all as required at site including dismantling and taking down of old unserviceable panel complete all as specified & directed :- 'BUS BAR - Aluminium bus bar system of capacity 600 amp four pole duly colour coded. INCOMER - MCCB, 4 pole of capacity 400 amps with breaking capacity of 36 KA . - 01 No. Outgoing - (a) MCCB, 4 pole of capacity 250 amps with breaking capacity of 25 KA . - 01 No. Contd...
(b) MCCB, 4 pole of capacity 160 amps with breaking capacity of 25 KA . - 02 No. (c) MCCB, 4 pole of capacity 100 amps with breaking capacity of 25 KA . - 01 No. (d) MCCB, 4 pole of capacity 63 amps with breaking capacity of 25 KA . - 01 No. (e) MCB, 4 pole of capacity 32 amps with breaking capacity of 10 KA . - 02 No. (f) MCB, 4 pole of capacity 63 amps with breaking capacity of 10 KA . - 01 No. (g) MCB, 4 pole of capacity 6 amps with breaking capacity of 10 KA . - 01 No. (h) Timer switch and contactor for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates. Nos-01 (j) Digital multimeter - 01 No (k) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three
Supply, installtion,testing commisioning of LT panel, CPRI approved out door typeof size not less than 1300x500x1900mm, platform mounted, totally enclosed, dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA sheet including inner chambers / partitions to mount the following electrical accessories with angle iron 75x75x6mm frame work, having front & rear hinged doors, lifting lugs 2 Nos, provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Aluminium strip of suitable size and necessary grouting/ foundation all as required at site including dismantling and taking down of old unserviceable panel including replacement of lugs for incoming / outgoing cables as per existing all as specified & directed :-
BUS BAR - Aluminium bus bar system of capacity 300 amp four pole duly colour coded. INCOMER - MCCB, 4 pole of capacity 250 amps with breaking capacity of 36 KA . - 01 No. Outgoing - (a) MCCB, 4 pole of capacity 160 amps with breaking capacity of 25 KA . - 01 No. (b) MCCB, 4 pole of capacity 100 amps with breaking capacity of 25 KA . - 02 No. (c) MCCB, 4 pole of capacity 63 amps with breaking capacity of 25 KA . - 02 No. (d) MCB, 4 pole of capacity 32 amps with breaking capacity of 10 KA . - 02 No. (e) MCB, 4 pole of capacity 63 amps with breaking capacity of 10 KA . - 01 No. (f) MCB, 4 pole of capacity 6 amps with breaking capacity of 10 KA . - 01 No. (g) Timer switch and contactor for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates -01No (j) Digital multimeter - 01 No (k) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three
Supply, installtion,testing commisioning of LT panel, CPRI approved out door type of size not less than 1900x1300x500mm, platform mounted, totally enclosed, dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA sheet complete including inner chambers/partitions to mount the following electrical accessories with angle iron 75x75x6mm frame work, having front & rear hinged doors, lifting lugs 2 Nos, provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Aluminium strip of suitable size and necessary grouting/ foundation all as required at site including dismantling and taking down of old unserviceable panel including replacement of lugs for incoming / outgoing cables as per existing all as specified & directed :- BUS BAR - Aluminium bus bar system of capacity 300 amp four pole duly colour coded. INCOMER - MCCB, 4 pole of capacity 160 amps with breaking capacity of 36 KA . - 01 No. Outgoing - (a) MCCB, 4 pole of capacity 100 amps with breaking capacity of 25 KA . - 01 No. (b) MCCB, 4 pole of capacity 63 amps with breaking capacity of 25 KA . - 02 No. contd...
(c) MCB, 4 pole of capacity 32 amps with breaking capacity of 10 KA . - 02 No. (d) MCB, 4 pole of capacity 63 amps with breaking capacity of 10 KA . - 01 No. (e) MCB, 4 pole of capacity 6 amps with breaking capacity of 10 KA . - 01 No. (f) Timer switch and contactor for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates. Nos-01 (g) Digital multimeter - 01 No (h) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_843723.xls
BOQ • 1.88 MB
tender86517.pdf
Tender Documents • 0.88 MB
cor.pdf
PDF • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .