Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | Admitted-Finance |
| 2 | Admitted-Finance 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | Admitted-Finance |
| 3 | Admitted-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 Dec 2021, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
PERIODICAL MAINTENANCE AND SERVICING OF REFRIGERATOR ACs WATER COOLER DESERT COOLER WATER HEATER AND REPAIR REPLACEMENT OF STREET LIGHT AND CONNECTED WORKS AT AF STN RAJOKRI UNDER AGE EM AF RAJOKRI OF GE AF GURGAON
2021_MES_491256_1
CA NO GE/GUR-/NIT-76/2021-22
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹90,000
4 Jan 2022
29 Nov 2021
29 Dec 2021
29 Nov 2021
27 Dec 2021
13 Dec 2021
Amount
Comprehensive maintenance of electric Desert cooler , 230 volts single phase AC having nominal air flow capacity of 4000 cfm and cleaning inside the surface insluding brazing /welding if required ,replacement of worn out parts,reassembling and refixing on site ,including preparation of surface of Desert cooler and painting with 2 coat of white enamelled paint by spray painting machine complete all as specified and directed.
S&F in replacement of 18" , 230 volts , single phase fan motor of desert cooler with copper winding complete all as specified and directed.
M&L for replacement of Bush bearing of fan motor for desert cooler complete all as specified and directed.
M&L for replacement of tullu pump with pipe for desert cooler complete all as specified and directed.
M&L for replacement of fan motor blade suitable of any size of desert cooler complete all as specified and directed.
M&L of cotton wood pad set of superior quality for desert cooler complete all as specified and directed.
S&F of wastage water tray of any capacity of water cooler complete all as specified and directed.
S&F in replacement of new indoor unit of split AC of capacity 1.5 ton with suitable for existing out door unit from authorized dealers of company complete all as specified & directed.
S&F in replacement of new outdoor unit of split AC of capacity 1.5 ton with suitable for existing indoor door unit from authorized dealers of company complete all as specified & directed.
Comprehensive maintenance of electric geyser ,storage type 230 volts single phase AC ,25/50 lts capacity and descaling of inner tank of geyser ,insluding brazing /welding if required ,replacement of worn out parts,reassembling and refixing on site ,including preparation of surface of geyser and painting with 2 coat of white enamelled paint by spray painting machine complete all as specified and directed
S&F in replacement of geyser assembly suitable to fix thermostate , heating element as of the existing size including six nos. of clamps with bolts and nuts etc complete all as specified and directed.
S&F in replacement of heating element 2000 watt capacity triangular type complete all as specified and directed. .
S&F in replacement of heating element 1500 watt capacity triangular type complete all as specified and directed. .
S&F in replacement of heating element 1500 watt capacity circular type complete all as specified and directed. .
S&F in replacement of thermostate suitable for storage type water heater complete all as specified and directed. .
Supply and fix stainless steel tank for 25 ltr storage type water heater complete all as specified and directed..
Supply and fix Copper tank for 25 ltr storage type water heater complete all as specified and directed. .
M&L for Servicing, Oiling, Greasing and Cleaning of window type/ split type AC1.5/2 Ton with high pressure pump of any capacity, checking of defects/ leaking and adjusting setting to work and testing complete all as specified & directed.
M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.5 ton Split/W/T type AC complete all as specified and directed.
M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 2.0 ton Split/W/T type AC complete all as specified and directed.
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water of W/T and split type AC 1/1.5 Ton capacity complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of Sch "A"
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water of W/T and split type AC 2 Ton capacity complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of Sch "A"
M&L for replacement running capacitor of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
M&L for replacement of starting relay of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
M&L for replacement starting capacitor of existing make and capacity duly ISI marked for window type A/C 1.5 ton and split type AC 1/1.5/2 ton capacity complete all as specified and directed.
S&F in replacement of Electronic control (PCB) of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
S&F in replacement of blower motor of capacity 1.5/2.0 Ton complete all as specified & directed.
S&F in replacement of new rotary type AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 1.5Ton capacity complete all as specified & directed.
S&F in replacement of new rotary type AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 2.0 Ton capacity complete all as specified & directed.
S&F in repair replecement new sealed compressor reciprocatng type suitable for 1.5 Ton capacity single phase, 230 Volt, 50 Hz split/ window type airconditoner in and including refilling refrigerant gas R-22 filling up to required pressure and testing complete all as specified and directed.
S&F in repair replecement new sealed compressor reciprocating type suitable for 2.0 Ton capacity single phase, 230 Volt, 50 Hz split/ window type air conditoner in and including refrigerant gas filling up to required level complete all as specified and directed.
S&F in replacement of Evaporator coil complete all as specified and directed.
S&F in replacement of Suction/Discharge valve complete all as specified and directed.
S&F in replacement of Copper tube for 1.5 /2.0 Ton split AC 1/4 complete all as specified and directed.
S&F in replacement of Copper tube for 1.5 /2.00 Ton split AC 1/2 complete all as specified and directed.
S&F in replacement of Copper tube cover complete all as specified and directed.
Material and labour for drain pipe rigid and flexible 20mm dia with clamps of suitable size as per site requirement all as specified and directed.
S&F in replacement of insulation pipe size ¾” or 1” dia for split AC 1.5 / 2 Ton complete all as specified and directed.
M&L for servicing, oiling, Greasing and Cleaning of water cooler of capacity 40/80 ltr with high pressure pump , checking of defects/ leaking and adjusting setting to work and testing complete all as specified & directed.
M&L for shifting/relocating of split/window type AC 1.5/2 Ton from one location to another location as required including all connected works complete all as specified and directed by Engr-in-charge. Note :- (i) The cost of dismantling and refixing of Split/Window type AC deemed to be included in unit rate.
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of capacity 40/80 ltr complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of Sch "A" (iv) Refilling and toping up of refrigenrant (type and quantity) as required on site is measured and paid separately.
S&F compressor reciprocating type (hermetically) sealed for capacity 40/80 litre water cooler complete all as specified and as directed.
S&F in repair of thermostat switch suitable for existing water cooler any make and capacity complete all as specified and as directed. Make: Renutrol/Indofos/Annapurna/Totaline
M&L in replacement of starting relay and overload relay suitable for existing size and make water coolercomplete all as specified and as directed. Make: Epcos/Asian
M&L in replacement of starting capacitor for water cooler suitable for existing size & make water cooler complete all as specified and as directed.
M&L in replacement of running capacitor suitable for existing size & make water cooler complete all as specified and as directed.
M&L for Dismantling of old defective condenser fan motor of water cooler of any make and capacity and refixing and testing the same after rewinding with super enameled copper wire of existing gauge or gauge as approved by Engineer-in-Charge including replacement of shaft/ bush etccomplete all as specified and as directed.
S&F in replacement of fan blade of condenser motor of any make and capacity of water cooler complete all as specified and as directed.
M&L for servicing of deep freezer any capacity and size by cleaning greasing including painting with one coat of super synthetic enameled paint including preparation of surfaces complete all as specified and as directed.
S&F of starting relay of deep freezer of any size & make complete all as specified and as directed.
M&L for gas charging in deep freezer any make and capacity including testing of leakage complete all as specified and as directed.
S&F of thermostat switch for deep freezer any make & capacity complete all as specified and as directed.
M&L for refrigerator of any capacity including replacement of following UNSV Parts starting relay - 01 No., over load relay-01 No, capacitor 20 mfd -01No, thermostate switch - 01 No, Door rubber beeding set - 01 Set complete all as specified and directed.
S&F in repair replecement new sealed compressor of suitable for Refrigerator of single phase, 230 Volt, 50 Hz of Refigerator in and including refrigerant gas filling up to required level complete all as specified and directed.
Supply & fix in replacement ceiling fans complete with accessories 230 V,1200 mm sweep. BEE 5 star rated complete all as specified & directed by engr - in- charge
Supply & fix in replacement exhaust fans single phase 230/ 240 V of size 450 mm sweep with louver Steel body complete all as specified & directed by engr - in- charge
M&L for rewinding of following fans with same gauge of super enameled copper wire complete varnishing ,baking ,connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with nots /bolts/washer /split pin and blade screw s etc testing , complete all as specified and directed. NOTE: (i) Spare parts like bearing,capacitor,bushes if required will be measured and paid separately. (ii) The rates shall be deemed to include dismantling of fan and reassembling after repair /replacement of worn out parts.
Ceiling fan 1200 /1400 mm sweep
Exhaust fan 300 mm sweep
Exhaust fan 450 mm sweep
Wall mounted fans 400 mm /450mm sweep
Supply and fix in repair ball bearing suitable for the following fans : Make :-NBC/SKF/Tata
Ceiling fan 1200 /1400 mm sweep
Exhaust fan 300 mm sweep
Exhaust fan 450 mm sweep
Wall mounted fan 400 mm sweep
Supply and fix in repair capacitor 2.5 mfd, 230 volt ,50 hz all as specified and as directed.Make : Tibcon
Supply and fix in repair capacitor 3.15 mfd, 230 volt ,50 hz all as specified and as directed.Make : Tibcon
Supply and fix in repair capacitor 4 mfd, 230 volt ,50 hz all as specified and as directed Make : Tibcon
Supply and fixing in replecement of 63 to 160 Amp, 415 Volts, 50 Hz Power contactor of coil voltage 240 Volts, complete all as specified and directed. Make: L&T/Schineider/Havells
Supply and fix GI pipe light grade of following sizes for cable protection in trenches/ at PCC poles for loopin/ loopout of cable and cable entry at bldg/block end,all as per specified and directed.
i) 80 mm dia
ii) 40 mm dia
Supply & install in repair testing , commissioning of feeder pillar board Kiosk type ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) floor mounted , factory assembled, outdoor type weather and vermin proof (Protection Class IP-54) made out of 40m x 40mm x 6mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement ,powder coated externally and internally after seven tanks treatment and lifting channel, fully compartmentalized design comple Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding complete all as specified and as directed.
M&L for cutting,clearing bushes/small plants and grass surrounding the E/M installations and removing the debris to a distance of 50m complete all as specified.
S&F MCCB 100 A ,3 pole ,16 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F MCCB 125 A ,3 pole ,16 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F MCCB 250 A ,3 pole ,16 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified.
M&L for excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out soil all as specified and directed.
M&L for returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
M&L for removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete as specified and directed.
Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted. Note : Punned down thickness shall be measured and paid .
Supply and laying un-reinforced precast concrete LV cable cover class Type I with 250 x 150 x 40 mm, as specified and directed.
Supply, laying and testing in replacement cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade with following cross sectional area complete all as specified and as directed. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
XLPE LT Cable 3.5 core 120 Sqmm
XLPE LT Cable 3.5 core 50 sqmm
XLPE LT Cable 4 core 25 sqmm
XLPE LT Cable 2 core 16 sqmm
Taking down the existing cables from trenches of any type (LT/HT) and size complete all as specified and directed.
S & F in replacement of Aluminium Cable lugs/Thimbles upto size 16 to 150 sqmm complete all as specified.
M&L for Boring of holes under road, 600 mm below the ground level to pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
Taking down and dismantling HPSV street/flood/garden light fitting with GI bracket for 70/150/250 watt capacity of any make/type from pole/GI pipe unserviceable items to be kept in safe custody and taken as credit complete all as specified and directed.
Supply and Fixing in replecement LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant.complete all as specified and as directed . Note : Any reducer to suit the manufacturer mounting dia for fixing of fitting to existing bracket shall be deemed to be included in the rates quoted by the Contractor
Supply and Fixing in replecement circular LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant.complete all as specified and as directed . Note : Any reducer to suit the manufacturer mounting dia for fixing of fitting to existing bracket shall be deemed to be included in the rates quoted by the Contractor.
Supply and Fixing LED street light luminaire 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed .
Supply and Fixing LED street light luminaire 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed .
Supply and Fixing LED post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed .
Supply and Fixing in replecement LED Decorative Garden/post-top light for 360 degree indirect light IP-65 grade of proterction with High power LED of 10 watt with resistance to impact and corrosion. Glare free and better uniformity.Milky version .complete all as specified and as directed . Note : Any reducer to suit the manufacturer mounting dia for fixing of fitting to existing bracket shall be deemed to be included in the rates quoted by the Contractor.
M&L for GI bracket for street light fitting made of 40mm bore light grade GI tube bent to shape required, fixed with and including MS flat iron clamps, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete including taking down the existing bracket and refixing and connecting up the light fitting etc all as directed.
Supply and fixing weather proof street light junction box PVC of size 300 x 200 x 105mm including MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and as directed. Make : Hensel/Sintex/Universal Switch Gear control Note : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection.
M/S Anand Enterprises
Saini Enterprises
R R Associates
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .