Executive Engineer, Bardhaman Electrical Division,
Purta Bhavan, 1st Floor, Purba Bardhaman
Emergent replacement of non-functional parts/ components incl. checking, testing, rectification, re- installation and re-commissioning of the existing Fire Detection and Alarming System at Burdwan Medical College and Hospital in the District of Purba
2025_WBPWD_884445_1
WBPWD/EEBED/NIQ-14/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Purba Bardhaman
Please refer Tender documents.
4 documents required · 4 mandatory
₹62,000
24 Sept 2025
29 Jul 2025
14 Aug 2025
29 Jul 2025
12 Aug 2025
29 Jul 2025
Amount
Cleaning, servicing and checking of all existing Intelligent Multisensor Fire Detectors inbuilt with optical smoke sensor as well as additional Heat Detector Sensor as per direction of EIC incl. labour charge for dismaintaling the existing fire detection system / equipments & others such as PVC pipe,wire,dector,device and other accessories etc. by Co's own tools, tackles & equipments in different buildings within camous of BMCH.
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Make : Siemens / Edward / Honeywell / Bosch / Secutron - Make as per choice of EIC or Compatible with existing / same as existing dectector) in replacement of old damaged one in different buildings within camous of BMCH.
Supply and installation of glass protection cover of existing Addressable Manual Call Point with in built fault isolator in replacement of old damaged one (Make : Siemens / Edward / Honeywell / Bosch / Secutron - Make as per choice of EIC or Compatible with existing / same as existing dectector) in different buildings within camous of BMCH.
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP-42 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Make : Siemens / Edward / Honeywell / Bosch / Secutron - Make as per choice of EIC or Compatible with existing / same as existing dectector) in different buildings within camous of BMCH.
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / Polycab / RR Cable) with 20 mm NB PVC rigid conduit pipe MMS (Make: Precisson MMS) on the surface of the wall in different buildings within camous of BMCH.
Testing, rectification and rechecking of all the Loop lines connected with the existing & newly installed Microprocessor based Intelligent Addressable Fire Alarm Control Panel, Detectors and other Devices for addressing the entire fire detection system as per direction of EIC in different buildings within camous of BMCH and make the system healthy. (For Loop Lines of all the 9 Nos. Panel)
Supply and installation of 12 Volt 7Ah capacity VRLA Battery of Lead Acid, Sealed Maintenance Free (SMF) and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning (Make- Exide or equivalent model of Amaron/Luminous) for the existing fire alarm control panel in replacement of old defective one in different buildings within camous of BMCH.
Checking, testing, reprogramming and recommissioning of existing Microprocessor based Intelligent, addressable existing fire alarm control panel ( VDS / UL / LPCB & FM approved ) and done total system healthy with all detector and hooters (Make of FD Panel: Siemens / Edward / Securton) in different buildings within camous of BMCH and make the system healthy.
Supply, Installation, Testing & Commisioning of Microprocessor based Intelligent, soft addressable, (VDS/UL/FM/ULC approved), ethernet ready fire alarm control panel, with each loop capable of taking minimum 120 devices. The panel shall be able to give pin point location of all fire/ fault conditions. The Panel should be able to store minimum 1000 log events in its Memory as per recommended standards.
The panel shall have in-built rectifier, Loop cards, interface card for connecting external serial printer, 4 line, 40 charecter/line alphanumeric LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working or capable of operating the system for 2 hours during alarm condition, with integral battery charger complete as required. The panel shall have extra loop card to serve as stand by in case of burntout or malfunctioning of any operating loop cards. The FACP shall be capable of being networked with other similar FACP located at different part of the premises through ethernet (LAN). The panel should have necessary Ethernet card installed in it for bidirectional communication with 3rd party BMS/Scada and 3rd party public address system. All necessary memory map (incl. device address) should be provided. Minimum 4 potential free spare contacts should be provided with the panel.The system must be preloaded with open source licenced software & all the ID, Password, License Key etc. should be provided to PWD before handover. (Make : Siemens / Edward / Honeywell / Bosch / Secutron - Make as per choice of EIC or Compatible with existing / same as existing dectector) 4 Loop Panels
Terms & Conditions: (i) The Agency must procure the materials from the Manufacturer for the standard product Warranty/Manufacturer should have authorized the bidding agency directly for the project’s supply and installation support/ Bidding Agency Must have submit the authorization certificate with tender document from the Manufacturer which they quoted. (ii) Documents that authenticates such procurement from the Manufacturer/Standard product warranty document from Manufacturer Product related documents authenticate by Manufacturer or OEM directly through Agency. (iii) If any refurbished material is supplied and installed, panel action will be taken as per existing rule. iv) Every panel must be safeguarded with a grill guard or grill housing and fitted with an appropriate locking mechanism as per direction of EIC.
Making necessary Auto CADD proper drawing (maintaining symbol & other points as per International Norms / NBC 2009) of total installation of Fire Detection System (existing & new) in different buildings within camous of BMCH in A2 / A3 Page, 4 Copy Each & submitted to the office as per direction of EIC.
Cost for periodical checking arrangement by 1(one) no skilled and 1(one) no Un-skilled person for cleaning of all detector, MCP and trobleshooot the fault if anything happened as & when informed by concerned AE / JE should be carried out by for 1 (one) year after the date of completion of the total Cleanning , Checking, Testing , Re-programming and Re-commissioning job.
Supply & Installation of 24V adopter for hooter with all other necessary accessories. Wattage rating as per existing (Make : Siemens / Edward / Honeywell / Bosch / Secutron - Make as per choice of EIC or Compatible with existing / same as existing dectector)
NOTE: 1. The Fire Alarm system shall comply with latest requirements of, 1. National Fire Protection Association (NFPA) Standards 2. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm Code 5. local Statutory Regulations 6. Original Equipment Manufacturer Recommendation
TESTS: 1. The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer (OEM) of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults. continuity, and insulation and other tests as per above standards must be done.
Rates to be quoted will be inclusive of all the taxes incl. GST. No other additional charges will be applicable in addition to the quoted rates.
TAPAN KUMAR SARKAR (BID ID -6796115)
UJJWAL MUKHERJEE (BID ID -6796086)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .