SE Purchase dongalia
SE Purchase dongalia
Procurement of spares of Siemens Make Electropneumatic positioners installed in 2x600MW, SSTPP, MPPGCL, Dongalia, Khandwa
2020_MPPGC_87835_1
PT-1133
Single
Miscellaneous Goods
Item Rate
90 days
dongalia
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Payable To
Exempted
1 Sept 2020
6 May 2020
23 May 2020
6 May 2020
20 May 2020
6 May 2020
180 days
Siemens make Single acting fail freeze Smart Positioner Specification-Positioner Model no – 6DR5210-0EN00-0AA0-Z F01 Inlet Air Pressure: 1.4 to 7 bar. Ambient Temp: -30 Deg C to +80 Deg C. Degree of protection – IP 66 according to EN 60529 / NEMA 4X Input: 2, 3, 4 Wire systems (0/4 to 20 mA) Positioner: With HART For actuator – single acting Housing: Makrolon
Position Feedback Transmitter Specification-Model No: 6DR4004-6J Rated Signal Range: 4 to 20 mA short circuit Proof. Power Supply: +12 to +30 V DC. Transmission Error: ≤ 0.3% Resolution: ≤ 0.1%
Single acting Gauge Block with 02 Gauges Specification-Gauge made of plastic and block made of Aluminium
Siemens make Double acting fail freeze Smart Positioner Specification-Model NO: 6DR5120-0NN00-0AA0-Z F01 Inlet Air Pressure: 1.4 to 7 bar. Ambient Temp: -30 Deg C to +80 Deg C. Degree of protection – IP 66 according to EN 60529 / NEMA 4X Input: 2 Wire (4 to 20 mA) with HART Protocol For actuator – double acting Housing: Makrolon
Position Feedback Transmitter Specification-Model No: 6DR4004-8J Rated Signal Range: 4 to 20 mA short circuit Proof Power Supply: +12 to +35 V DC. Transmission Error: ≤ 0.3% Resolution: ≤ 0.1%
Double acting Gauge Block with 03 Gauges Specification-Gauge made of plastic and block made of Aluminium
Siemens make SingleActing fail freeze flameproof Smart Positioner Specification-Positioner Model no – 6DR5225-0EN00-0AA0-Z F01 Qty: 01 no Inlet Air Pressure: 1.4 to 7 bar Ambient Temp: -30 Deg C to +80 Deg C. Degree of protection: IP 66 according to EN-60529 / NEMA 4X Input: 2, 3, 4-wire systems (4 to 20 mA) Positioner: With HART For Actuator – double acting type Enclosure Aluminum EEx d casing (flame-proof)
(b) Position Feedback Transmitter Specification-Model No: 6DR4004-6J Rated Signal Range: 4 to 20 mA short circuit Proof. Power Supply: +12 to +30 V DC. Transmission Error: ≤ 0.3% Resolution: ≤ 0.1%
Single acting Gauge Block with 02 Gauges Specification-Gauge made of plastic and block made of Aluminium
Siemens make Single acting fail freeze Smart Positioner with remote position Specification-Positioner Model no – 6DR5210-0EN00-0AA0-Z F01 Inlet Air Pressure: 1.4 to 7 bar. Ambient Temp: -30 Deg C to +80 Deg C. Degree of protection – IP 66 according to EN 60529 / NEMA 4X Input: 2, 3, 4 Wire systems (0/4 to 20 mA) Positioner: With HART For actuator – single acting Housing: Makrolon
Position Feedback Transmitter Specification-Model No: 6DR4004-6J Rated Signal Range: 4 to 20 mA short circuit Proof. Power Supply: +12 to +30 V DC. Transmission Error: ≤ 0.3% Resolution: ≤ 0.1%
Single acting Gauge Block with 02 Gauges Specification-Gauge made of plastic and block made of Aluminium
External Position detection system Specification-separate mounting of position sensor and controller unit Positioner housing with integral potentiometer & sliding clutch
EMC filter module Specification-EMC filter module forms the interface between external positions Sensors and the basic electronics of the positioner
Siemens make Double acting fail freeze Smart Positioner with remote position Specification-Model NO: 6DR5120-0NN00-0AA0-Z F01 Inlet Air Pressure: 1.4 to 7 bar. Ambient Temp: -30 Deg C to +80 Deg C. Degree of protection – IP 66 according to EN 60529 / NEMA 4X Input: 2 Wire (4 to 20 mA) with HART Protocol For actuator – double acting Housing: Makrolon
Position Feedback Transmitter Specification-Model No: 6DR4004-8J Rated Signal Range: 4 to 20 mA short circuit Proof Power Supply: +12 to +35 V DC. Transmission Error: ≤ 0.3% Resolution: ≤ 0.1%
Double acting Gauge Block with 03 Gauges Specification-Gauge made of plastic and block made of Aluminium
External Position detection system Specification-separate mounting of position sensor and controller unit Positioner housing with integral potentiometer & sliding clutch
EMC filter module Specification-EMC filter module forms the interface between external positions Sensors and the basic electronics of the positioner
stage.html
html • 0.04 MB
technical_103646.pdf
PDF • 0.29 MB
techsummary_103646.pdf
PDF • 0.08 MB
finance_103646.pdf
PDF • 0.40 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_103646.pdf
PDF • 0.51 MB
T-4958.pdf
PDF • 4.80 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .