Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹31.6 L+₹3.8 L (13.5%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹32.2 L+₹4.3 L (15.3%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹33.3 L+₹5.4 L (19.3%)Rejected-Finance 0 NAGLA UDHA AZIJ PUR SOHALLA ROAD DHANOLI AGRA AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹33.4 L+₹5.5 L (19.7%)Rejected-Finance KE 100 B KAVERI KUNJ PHASE I KAMLA NAGAR AGRA 282005 | AGRA | AGRA | UTTAR PRADESH | 282005 | L5 | Rejected-Finance Being other than lowest |
| Sl No | Description | Qty | Unit | Balaji Associate L7 | M/s SCHOLASTIC ENTERPRISES L6 | durgey traders L4 | CHAHAR CONTRACTOR AND SUPPLIERS L2 | GUPTA ENGINEERING WORKS L8 | M/s Sumer Associates L5 | MUKTA AND COMPANY L3 | M/S GUPTA ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and Laying double walled corrugated (DWC) HDPE duct pipe in 6 mtr lenght conforming to IS 16205 Pt-24 of approved color complete with fittings for cable protection of size 50mm outer dia and 38mm inner dia complete all as specified and directed. Make:- Astral/ Universal/ Dutron/SFMC as approved by GE. | 1,450 | RM | 53.9 ₹78,155 | 45 ₹65,250 Lowest | 55 ₹79,750 | 90 ₹1,30,500 | 48.87 ₹70,861.5 | 75 ₹1,08,750 | 45 ₹65,250 Lowest | 65 ₹94,250 |
| 2.00 | Description all as per item No 1 above but 63mm outer dia and 50mm inner dia and ditto | 1,700 | RM | 72.9 ₹1,23,930 | 75 ₹1,27,500 | 85 ₹1,44,500 | 95 ₹1,61,500 | 71.56 ₹1,21,652 | 100 ₹1,70,000 | 60 ₹1,02,000 Lowest | 80 ₹1,36,000 |
| 3.00 | Description all as per item No 1 abovebut 75mm outer dia and 63mm inner dia | 1,250 | RM | 102.8 ₹1,28,500 | 107 ₹1,33,750 | 98 ₹1,22,500 | 100 ₹1,25,000 | 102 ₹1,27,500 | 100 ₹1,25,000 | 70 ₹87,500 Lowest | 100 ₹1,25,000 |
| 4.00 | Description all as per item No 1 above but 90mm outer dia and 75mm inner dia | 200 | RM | 119.99 ₹23,998 | 128 ₹25,600 | 130 ₹26,000 | 105 ₹21,000 | 121.14 ₹24,228 | 140 ₹28,000 | 95 ₹19,000 Lowest | 140 ₹28,000 |
| 5.00 | Supply, Fix & install MCCB with factory made sheet metal enclosure with provision of cable connection for incoming and outgoing complete all as specified and directed and consisting of the followings :-
a) MCCB 160 Amps, 25KA , 4 pole with thermal magnetic release -01 No
b) MCCB sheet steel enclosure 'A' Frame FP - 01 No | 7 | EACH | 10,500 ₹73,500 | 18,000 ₹1,26,000 | 16,000 ₹1,12,000 | 12,480 ₹87,360 | 13,500 ₹94,500 | 14,000 ₹98,000 | 12,000 ₹84,000 | 6,000 ₹42,000 Lowest |
| 6.00 | Supply, Fix & install MCCB with factory made sheet metal enclosure with provision of cable connection for incoming and outgoing complete all as specified and directed and consisting of the followings :-
a) MCCB 250 Amps, 25KA , 4 pole with thermal magnetic release -01 No
b) MCCB sheet steel enclosure 'A' Frame FP - 01 No | 5 | EACH | 12,500 ₹62,500 Lowest | 20,000 ₹1,00,000 | 18,000 ₹90,000 | 14,040 ₹70,200 | 16,500 ₹82,500 | 16,000 ₹80,000 | 14,000 ₹70,000 | 12,500 ₹62,500 Lowest |
| 7.00 | M&L for drilling suitable dia horizontal bore holes for insertion / laying of 50/100 mm bore GI tubing of any description below/under road surface/floors etc with using manual devices as required at site including making good disturbed surface to match with the existing strata after laying pipes complete all as specified and as directed. | 28 | RM | 400 ₹11,200 | 300 ₹8,400 | 450 ₹12,600 | 351 ₹9,828 | 250 ₹7,000 | 200 ₹5,600 Lowest | 500 ₹14,000 | 400 ₹11,200 |
| 8.00 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. | 60 | RM | 450 ₹27,000 | 300 ₹18,000 Lowest | 1,800 ₹1,08,000 | 1,404 ₹84,240 | 900 ₹54,000 | 1,650 ₹99,000 | 1,800 ₹1,08,000 | 500 ₹30,000 |
| 9.00 | M & L for detecting the fault of underground LT cable by using fault locator machine including excavation required for fault confirmation and opening of cable connection from panel and re connection after fault location complete all as specified and directed.
Note : The Fault locator machine shall be provided by the contractoras and when directed by engineer-in-charge. | 15 | EACH JOB | 7,000 ₹1,05,000 | 15,000 ₹2,25,000 | 6,000 ₹90,000 | 6,630 ₹99,450 | 5,500 ₹82,500 | 500 ₹7,500 Lowest | 8,500 ₹1,27,500 | 3,000 ₹45,000 |
| 10.00M&L for replacement of aluminium lugs for LT cable connection line suitable for system and fixed complete including taking down old unserviceable lugs and cables all as specified and directed of the following sizes :- | |||||||||||
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
19 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE TECH AREA AGRA
Military Engineers Services Garrison Engineer (AF) Tech Area Agra - 282008
REPAIR AND MAINT OF LT UG CABLES, CABLE JOINT AND CONNECTED ITEMS IN ZONE B AND C TECH AREA UNDER GE (AF) TECH AREA AGRA
2025_MES_714540_1
8200-1713/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF TECH ATREA AGRA
Class d category b(i)
9 documents required · 9 mandatory
₹500
Yes
GE TECH AREA AGRA
₹80,000
Yes
16 Aug 2025
26 Jun 2025
23 Jul 2025
26 Jun 2025
19 Jul 2025
12 Jul 2025
Amount
Supply and Laying double walled corrugated (DWC) HDPE duct pipe in 6 mtr lenght conforming to IS 16205 Pt-24 of approved color complete with fittings for cable protection of size 50mm outer dia and 38mm inner dia complete all as specified and directed. Make:- Astral/ Universal/ Dutron/SFMC as approved by GE.
Description all as per item No 1 above but 63mm outer dia and 50mm inner dia and ditto
Description all as per item No 1 abovebut 75mm outer dia and 63mm inner dia
Description all as per item No 1 above but 90mm outer dia and 75mm inner dia
Supply, Fix & install MCCB with factory made sheet metal enclosure with provision of cable connection for incoming and outgoing complete all as specified and directed and consisting of the followings :- a) MCCB 160 Amps, 25KA , 4 pole with thermal magnetic release -01 No b) MCCB sheet steel enclosure 'A' Frame FP - 01 No
Supply, Fix & install MCCB with factory made sheet metal enclosure with provision of cable connection for incoming and outgoing complete all as specified and directed and consisting of the followings :- a) MCCB 250 Amps, 25KA , 4 pole with thermal magnetic release -01 No b) MCCB sheet steel enclosure 'A' Frame FP - 01 No
M&L for drilling suitable dia horizontal bore holes for insertion / laying of 50/100 mm bore GI tubing of any description below/under road surface/floors etc with using manual devices as required at site including making good disturbed surface to match with the existing strata after laying pipes complete all as specified and as directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
M & L for detecting the fault of underground LT cable by using fault locator machine including excavation required for fault confirmation and opening of cable connection from panel and re connection after fault location complete all as specified and directed. Note : The Fault locator machine shall be provided by the contractoras and when directed by engineer-in-charge.
M&L for replacement of aluminium lugs for LT cable connection line suitable for system and fixed complete including taking down old unserviceable lugs and cables all as specified and directed of the following sizes :-
16 to 35 Sq mm
50 to 120 Sq mm
240 to 400 Sq mm
S&F in repair cable route indicator made out of MS sheet of size 30cmx20cm of 4mm thick with writing HT/LT cable with MS angle iron frame and two Nos legs of 1.2 m long of size 25x25x5mm fixed in ground in PCC (1:3:6) Type C-1 using 20mm graded aggregate, size15cmx15cm x15cm including painting with 02 coats of synthetic enamel paint of specified colour over one coat of red oxide primer complete all as specified and directed.
S&F in repair LED Bollards Light 10 Watt including neccessary arrangement complete all as specified and directed.
Carryout day to day rectification of external electrifical complaints such as repair, reconnection and lightening of burnt/loose cable lead in MCCB/MCB of existing LT indoor/outdoor panels and bus bar with suitable size lug/thimbles, attending external electrical no supply complaints, jointing of traced out burnt cable with suitable size of jointing kit complete all as specified and directed. Note : (a) Replacement of major items shall be measured and paid under relevant items of this schedule. (b) Repairing upto 03 points at different electrical system without any other material will be considered as one job.
M & L for repair of LT panel board/feeder pillar boxes including replacement of hinges/locking arrangments nut/bolts,welding, brazing etc of following sizes-
Supply only stainless steel hinges of size not less than 6" for fixing on existing panel board
Supply only stainless steel hinges of size not less than 4" for fixing on existing panel board
Material & labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.00mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate shall be at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of 25 x 4 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by medium 40 mm dia GI pipe connected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 40mm thick RCC pit cover reinforced with 8mm dia TMT bar at 75 mm c/c both ways and lifting arrangement by providing handles (02 Nos) of 12mm dia MS round bar and PCC chamber pit with PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) including excavation and earth work in soft/loose soil, returning, filling in with excavated soil and disposal of surplus spoil to a distance not exceeding 50m and shown in electrical Plate No 3 of SSR 2009 (Part-I) complete all as specified and directed.
Excavation in trenches in soft/ loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out etc complete all as specified and directed.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in soil etc complete all as specified and directed.
Removing excavated soil n. exc 50 m and depositing where directed at a level n.exc. 1.5 mtr above the starting point etc complete all as specified and directed.
Supply and lay in repair XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 10sq mm, 4 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed.
Supply and lay in repair XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 16sq mm, 4 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed.
Supply and lay in repair XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 25sq mm, 4 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed.
Supply and lay in repair XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 35sq mm, 3.5 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed.
Supply and lay in repair XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 50sq mm, 3.5 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed.
Supply and lay in repair XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 70sq mm, 3.5 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed.
Supply and lay in repair XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 95sq mm, 3.5 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed.
Supply and lay in repair XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size size 120sq mm, 3.5 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed.
Supply and lay in repair XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size size 240sq mm, 3.5 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed.
S&F in repair cable jointing kit suitable for LT 1100 volts cable (earthed) for out door , straight through joints, heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable etc complete all as specified and directed of the following sizes :-
10 to 50 Sqmm 3.5 core / 4 core
70 to 120 Sqmm 3.5 core
150 to 240 Sqmm 3.5 core
S&F in repair cable end jointing kit suitable for LT 1100 volts cable (earthed) for out door , heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable etc complete all as specified and directed of the following sizes :-
10 to 50 Sqmm 3.5 core / 4 core
70 to 120 Sqmm 3.5 core
150 to 240 Sqmm 3.5 core
Demolition of PCC/Black bitumen road of any description and in any position not otherwise specially provided , etc complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20 mm gradded stone aggregate for coping of poles, foundation panel board plat form etc complete all as specified and as directed including necessary from work.
M&L for rendering 10 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces etc complete all as specified and as directed.
Supply and fixing in repair 2 core, 4 Sqmm PVC insulated heavy duty electric cable unarmoured with stranded aluminium conductor etc complete all as specified and directed .
Supply and fixing in repair 2 core, 6 Sqmm PVC insulated heavy duty electric cable unarmoured with stranded aluminium conductor etc complete all as specified and directed .
Supply and fixing in repair 2 core, 10 Sqmm PVC insulated heavy duty electric cable unarmoured with stranded aluminium conductor etc complete all as specified and directed .
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 1000mm width x 1000mm Height (With Canopy & Base Channel) x 500mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 400 Sqmm for cable termination, The Feeder Pillar box shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar box shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the brick pedestal through grouting bolt. Bolts shall be grouted in PCC 1:2:4 type B1 (using 20mm graded aggregate) of suitable size of block. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation etc including dismentling / taking out old unserviceable bus bar chamber complete all as specified and directed.
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 750mm width x 750mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 300 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation etc including dismentling / taking out old unserviceable bus bar chamber complete all as specified and directed.
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 600mm width x 600mm Height (With Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 200 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation etc including dismentling / taking out old unserviceable bus bar chamber complete all as specified and directed.
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 500mm width x 500mm Height (With Canopy & Base Channel) x 300mm Depth, M.S. Channel Base Frame mounted suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 100 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation etc including dismentling / taking out old unserviceable bus bar chamber complete all as specified and directed.
CHAHAR CONTRACTOR AND SUPPLIERS (BID ID -3364006)
MUKTA AND COMPANY (BID ID -3364852)
durgey traders (BID ID -3363822)
M/s Sumer Associates (BID ID -3361935)
M/s SCHOLASTIC ENTERPRISES (BID ID -3362933)
Balaji Associate (BID ID -3362871)
GUPTA ENGINEERING WORKS (BID ID -3364491)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .