Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC 3 5 POORALKOTTAI GONUR EAST VILLAGE ANDIKARAI POST METTUR DAM 636 404 | METTUR DAM | METTUR | TAMIL NADU | 636404 | L1 | Accepted-AOC Tender Accepted | |
| 2 | L2₹15.6 L+₹31,628.72 (2.07%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹15.9 L+₹59,802.40 (3.92%)Rejected-AOC ERIKKADU THERMAL POST METTUR DAM 636 406 | METTUR DAM | SALEM | TAMIL NADU | 636406 | L3 | Rejected-AOC L3 | |
| 4 | L4₹16.5 L+₹1.2 L (7.86%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹17,600
Closing Date
11 Jan 2024, 2:00 pmClosed
The Superintending Engineer
O/o The Superintending Engineer Mettur EDC, Mettur
Improvement works to the existing Hostel Building to the Technical Training and Development Centre at Mettur EDC
2024_EB_405239_1
SE/MEDC/Spec.No.OT.02/23-24
Open Tender
Civil Works
Works
120 days
Mettur
As per BQR conditions
2 documents required · 2 mandatory
₹0
₹17,600
5 Mar 2024
3 Jan 2024
11 Jan 2024
3 Jan 2024
11 Jan 2024
3 Jan 2024
3 Jan 2024 - 11 Jan 2024
Amount
Dismantling the existing AC Sheet Roofing and clearing away with head load upto 100m, stacking for reuse etc., as directed by the Engineer in charge including labour charges, lead, lift, T&P etc., complete.
Dismantling the existing Brick / Stone masonry wall and clearing away with head load upto 100m, and lead of 1km including loading, unloading transporting charges etc., as directed by the Engineer in charge including labour charges, lead, lift, T&P etc., complete.
Dismantling the existing damaged Doors & windows including removal of Frames, hinges and fastenings etc., as directed by the Engineer at site including all labour charges, lead, lift, T&Ps etc., complete.
Dismantling the existing damaged Card board false ceiling with the grid arrangements as directed by the Engineer incharge including all labour charges, lead, lift, T&Ps etc., complete.
Dismantling of existing Telecom / Electrical cable lines of various sizes as directed by the Engineer in charge including all labour charges, lead, lift, T&Ps etc., complete.
Dismantling the existing Plain Cement Concrete and clearing away with head load upto 100m, with lead of 1km including loading, unloading transporting charges etc., as directed by the Engineer in charge including labour charges, lead, lift, T&P etc., complete.
Earth work excavation in all types of soils such as earth, SDR, medium rock, dense medium rock not requiring blasting for foundation and depositing on bank with initial lead of 10m & initial lift of 2m as directed by the Engineer in charge including all labour charges, lead, lift, T&Ps etc., complete.
Providing P.C.C. 1:4:8 using 40mm HBG metal for foundation as directed by the Engineer in charge including cost of all materials, labour charges, curing, T&P, leads, lifts etc., complete.
Providing P.C.C. 1:3:6 using 20mm HBG metal for foundation and flooring as directed by the Engineer in charge including cost of all materials, labour charges, curing, T&P, lead, lift etc., complete.
Brick work in CM 1:4 using IInd class chamber burnt bricks (9"x 4 1/2" x3”) for basement and super structure as directed by the Engineer in charge including cost of all materials, scaffolding, labour charges, curing, lead, lift, T&P, etc., complete.
Plastering in CM 1:5, 12mm (P Sand) thick for interior surfaces of all walls including cost of all materials, scaffolding charges, labour charges, curing, lead, lift, T&P etc., complete.
Supplying, fabricating and fixing in position MS Posts, MS Purlins, MS Doors etc., with required accessories such as but not limited to MS Angles, Channels, Pipes, flats, Square Bars, Shafts, Sheets etc., as per approved design and as directed by the Engineer in charge including cost of fabrication, transporting, cost of all materials, labour charges, lead, lift, T&P, one coat of red oxide primer, etc., complete.
Supplying and fixing of colour coated crimp curve metal roofing sheet of 0.50mm thick of ISI make over MS structural frame work as directed by the Engineer in charge including cost of all materials, labour charges, lead, lift, Safety arrangements and equipments and T&P etc., complete.
Flooring with Stain free Vitrified tiles of approved size, make, colour and pattern over 10mm thick Cement mortar 1:3 bedding and pointing with same coloured cement in all floors as directed by the Engineer incharge at site including cost of all materials, labour charges, lead, lift, T&P etc., complete as per standard specification.
Supply and installation of Anutone (or) Euivalent Brand of Acoustical False Ceiling of subtex nubby, square edge, glass fibre core fully encapsulated ceiling tile of size 595 x 595 x 15mm having volume density 120 Kgs / m3, weight 1.8 / 2.4 / 3 kg / m2 which is suspended by using 0.3mm thick skelet trelis T15 metal grid system. Skelet trelis T15 metal grid system of 600 x 600mm module includes skelet WA15 W30 wall angle with unequal flanges of 15 / 19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the skelet MT15 W36 MainT with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Skelet CT15 W12 CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 600mm centers in the perpendicular direction to the Main T15. Finally, the skelet CT15W06 CrossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15W12 CrossT in direction parallel to the Main T15 to result in 600 x 600mm module. The subtex nubby square edge of size 595 x 595 x 15mm shall be placed into the grid size of 600 x 600mm. Ensure arrow marks behind the tiles are oriented in one direction to achieve uniform shade. The systems to achieve noise reduction coefficient not less than 0.9 NRC, so as to have an neat appearance as directed by the department offices. The cost includes, cost of material, cost of labour, scaffolding, transportation, conveyance, etc. complying to standard specication.
Colour washing with two coats of Acyrlic Distemper over a coat of water based primer including applying with necesaary Wall Putty paste for filling and making the wall smooth by thorough scrapping the existing colour washing area for interior surfaces as directed by the engineer at site including cost of all materials such as Oil bound distemper, Wall Putty paste, Primer, scaffolding, labour, lead, lift etc., complete.
Painting with two coats of approved quality enamel paint over a coat of red oxide primer including Thorough scrapping, cost of all materials, brushes, lead, lift, Scaffolding, T&Ps etc., complete.
Wiring with 3 x 2.5 sqmm (36/0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling for lights, fan and buzzers with PVC accessories in with wall with TW switch box and 5A SP flush type switchs with continuous earthing for providing 2.5 Sq.mm multistand PVC wire of PVC light point / Fan point with 5amps switch, ceiling rose, cable, pipe, etc., complete.
Wiring with 3 x 2.5 sqmm (36/0.3) PVC insulated SC unsheathed copper conductor of cable 1100V grade in suitable PVC rigid pipe in wall and ceiling with PVC accessories in flush with wall Metal switch box with 5A 3 pin modular type non interlocking CS plug with continuous earthing for providing 2.5 Sq.mm multistand PVC wire for making good of concealed portion with suitable color for concealed PVC plug point cable, pipe, etc., complete.
Wiring with 3 x 4 sqmm (56/0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe in wall and ceiling with PVC accessories in flush with wall with Metal switch box with 15A 3 pin Modular type non interlocking CS plug with continuous earthing for providing 4 Sq.mm multistand PVC wire for making good of concealed portion with suitable color for concealed PVC plug point including cost of all materials such as cables, pipes, etc, complete.
Supplying and run of 4 of 6 Sqmm (84/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe on wall and ceiling with continuous earthing for providing 6 Sq.mm multistand PVC wire including cost of all materials such as cables, pipes, etc., complete.
Supply and fixing of box type single fluorescent fitting with copper choke and condensor complete with ISI Mark of 4ft 40 watts with ballast of Higher end (Philips / Crompton) with TW round blocks on wall or ceiling with with PVC unsheathed copper laed from terminals to the including cost of all materials such as cables, pipes, etc., complete.
Supply and fixing of 1200mm (48’) AC ceiling fan confirming to ISS 374 /1979 (Bajaj / Crompton / Usha) complete with stepped electronic square modular type regulator with required length down rod as per the site condition including cost of all materials such as cables, pipes, clamps etc., complete.
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board of double door type with metal door with IP43 protection with 1 No. 32A DP MCB as incoming and 6 Nos. 6A to 32A SPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB's should be with ISI mark (like standard make).
SGST For bidders within Tamilnadu
CGST For Bidders within Tamilnadu
IGST For Bidders outside of Tamilnadu
CMR ENGINEERING WORKS
NVS and Co
JR Construction
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .