Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 0 DHARAMBUGH KRALPORA BAGI MEHTAB B K PORA BUDGAM JAMMU KASHMIR 190019 | SRINAGAR | JAMMU AND KASHMIR | 190019 | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical NON RESPONSIVE |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
18 Apr 2022, 1:00 pmClosed
DGM ELECTRIC UNIT JKPCC LTD SRINAGAR
DGM ELECTRIC UNIT JKPCC LTD SRINAGAR
Internal Electrification work Public Health Center at Nunar Ganderbal
2022_PWDJK_166340_1
01/DGM/JKPCC/E/K of 2022-23
Open Tender
Electrical Works
Item Rate
30 days
GANDERBAL
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
FC JKPCC LTD A/c
₹38,000
21 Apr 2022
9 Apr 2022
18 Apr 2022
9 Apr 2022
18 Apr 2022
9 Apr 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.( Group C )
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed Pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 x 16 sqmm + 1 no.6 sqmm earth wirer .
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
3 Module (100mm X 75mm)
4 Module (125mm X 75mm)
6 Module (200mm X 75mm)
8 Module (125mm X 125mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
3 Module
4 Module
6 Module
8 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supply,installation,testing and commissioning of Ceiling/wall fans complete with double ball bearig,motorbearing,r,blades,down-rod canopies capacitor two module stepped type electronic fan regulator suitable for operation on 230V 50HZ 1-phase A.C supply complete as required
Supply,installation,testing & commissioning of 900 RPM 450mm ( Crompton Greaves trans Air or approved equivalent ) Exhaust Fan suitable for single phase 230v 50HZ AC supply Complete with motor louvers,shutters etc complete as required
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing 30 A, 240 V, TPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith30 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating,2pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply of Integral LED 4 ft luminaire with extruded almunium housing and Opal diffuser. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification. Luminaire shall be designed to emit at least 4000 nominal lumens at a system efficacy of at least 110 lumen/watt with a maximum system wattage of 40 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% and suitable for an operating voltage range of 140-270V AC. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have in house lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters
Supply of LED indoor surface/ Recess downlighter suitable for general lighting with Almunium Diecast housing with polycarbonate cover with diffused optics. The luminaire should have CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification. The fixture should have a minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 1800 lumens and maximum system wattage of 18 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 , THD <10% with inbuilt surge protection of 2.5Kv. The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection / termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Laying 0f one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required.
Above 95 sq. mm and upto 185 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X 185 sq. mm
Supplying of cables for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X 185 sq. mm A2XFY
Supply,Installation,testing and Commissioning of Cubical type L.T floor Panel board suitable for 415V 3phase 4wire 50HZ AC supply system including incomers,outgoings,bus-bar,interlocking etc,dust & vermin proof with lockable arrangement, powder coated with stand INCOMERS MCCB 250 Amp 4 Pole breaking 36 KA with spreader 1no Digital multifunctional-meter 1 no Indicating Lamps ( RYB ) 1set Current-Transformer ( 300/5A 10VA burden) class-1 1set Aluminium bus-bar 200 Amp FP E-91 Electrolutic AL 1sets. Out-Goings MCCB 100Amp 4P with Breaking capacity 36 KA 01 Nos MCB 80 Amp DP with Breaking capacity 36 KA 08 Nos MCB 40 Amp DP with Breaking capacity 12KA -8 Nos 200 Amp 4=Pole Change Over SwITCH 1 NO Load Bearing Member to be made out of 16SWG CRCA Sheet Partition to be made out of 16SWG CRCA Sheet Gland Plates to be made16 SWGmm thick Complete job.
M/S MOHAMMAD HUSSAIN BABA
MIR IRFAN ELECTRICAL/SUPPLIERS
M/S DREAMS GROUP
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .