| 1.00Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. | |||||
| 2.00 | a) up to 3 mtr. Depth | 266.6 | Cum | 340 ₹90,644 Lowest | 355 ₹94,643 |
| 3.00 | b) 3 m to 6 m depth | 165.52 | Cum | 404 ₹66,869.27 Lowest | 422 ₹69,848.6 |
| 4.00 | Reinforced Cement Concrete M-35 in Piles including Pile Load Test on single Vertical Pile in accordance with IS:2911(Part-IV) ( 2 Nos ) excluding steel reinforcement complete as per Drawing and Technical Specification.MORT&H Clause 1100 & 1700 | 334.35 | Mtr | 11,194 ₹37,42,713.9 Lowest | 11,845 ₹39,60,375.75 |
| 5.00 | Providing concrete for plain/reinforced concrete M15 levelling course below pile cap complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 | 15.32 | Cum | 3,895 ₹59,671.4 Lowest | 4,120 ₹63,118.4 |
| 6.00 | Reinforced Concrete M 30 in Pile Cap including centering shutering but excluding steel complete as per Drawing and Technical Specifications section 1200,1500 & 1700. | 154.44 | Cum | 4,483 ₹6,92,363.49 Lowest | 4,740 ₹7,32,055.08 |
| 7.00Reinforced Cement Concrete M-30 in sub structure including centering shutering but excluding steel reinforcement complete as per Drawing and Technical Specification. .MORT&H Clause 1500, 1700 & 2200 | |||||
| 8.00 | (Height upto 5 m) | 116.17 | Cum | 4,984 ₹5,78,976.33 Lowest | 5,100 ₹5,92,451.7 |
| 9.00 | Providing and laying of Filter media with granular crushed aggregates as per specifications to a thickness of not less than 600 mm complete as per drawing and Technical Specification. Clause 1200. | 59.62 | Cum | 1,679 ₹1,00,100.3 Lowest | 1,750 ₹1,04,333.25 |
| 10.00 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 | 88.24 | Rmt | 157.1 ₹13,862.5 Lowest | 166 ₹14,647.84 |
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
15 Sept 2023, 5:00 pmClosed
Er. Harjot Singh
Executive Engineer Provincial Division Gurdaspur
PB06306
2023_PWDBR_127943_1
Bid No 30 Dated 01.09.2023
Open Tender
Civil Works - Bridge Construction
Item Rate
270 days
Gurdaspur
Please refer Tender documents.
8 documents required · 8 mandatory
₹30,000
Executive Engineer Provincial Division Gurdaspur
₹2.9 L
13 Oct 2023
1 Sept 2023
18 Sept 2023
1 Sept 2023
15 Sept 2023
1 Sept 2023
Amount
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
a) up to 3 mtr. Depth
b) 3 m to 6 m depth
Reinforced Cement Concrete M-35 in Piles including Pile Load Test on single Vertical Pile in accordance with IS:2911(Part-IV) ( 2 Nos ) excluding steel reinforcement complete as per Drawing and Technical Specification.MORT&H Clause 1100 & 1700
Providing concrete for plain/reinforced concrete M15 levelling course below pile cap complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Reinforced Concrete M 30 in Pile Cap including centering shutering but excluding steel complete as per Drawing and Technical Specifications section 1200,1500 & 1700.
Reinforced Cement Concrete M-30 in sub structure including centering shutering but excluding steel reinforcement complete as per Drawing and Technical Specification. .MORT&H Clause 1500, 1700 & 2200
(Height upto 5 m)
Providing and laying of Filter media with granular crushed aggregates as per specifications to a thickness of not less than 600 mm complete as per drawing and Technical Specification. Clause 1200.
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Supplying fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II), section IX and clause 2005 of MORTH specifications complete including all accessories as per drawing and technical specifications
Providing and laying reinforced cement concrete M 30 in superstructure in deck slab including centering shutering but excluding steel complete as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.MORT&H Clause 2607
Drainage Spouts complete as per drawing and Technical specification clause 1209
Furnishing and Placing Reinforced cement concrete M 40 in Anti crash Railing including centering shutering but excluding steel complete as per drawing and Technical Specification(Sr no 14.1 D of MORT&H data book)
56 mm thick wearing coat consisting of 50 mm th. Bituminous concrete ,6 mm Mastic asphaltic including tack coat. As per MORT&H Specifications
Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm. clause ( Sr no 14.16 of MOST data book ) Clause 1700
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement (Fe 500 CST /TMT bars of RINL/TATA/SAIL/TISCO/JINDAL STEEL POWER LTD and Electro Steel conforming to IS 1786 Subject to requirement of IRC:21-2000 with latest amendments) complete as per Drawing and Technical Specifications. Sr no 12.40 , 13.6 & 14.2
Supplying, fitting and placing HYSD bar reinforcement (Fe 500/500-D) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Extra rate for Steel Fe-500/550-D ( Integrated Plant Marked).
Marking of Centre line, Zebra lines with hot applied thermoplastic road marking paint meterial conforming to MORT&H clause 803.4.2 and marking complete as per clause 803 of MORT&H specifications 2004 (upto date revision)
Providing and fixing Pavement marker (Cat eyes) made out if ABS of size 128mmx110x29.5mm with nail having having 50 mm stem of ABS. The Pavement Marker shall be installed with automatic machine and epoxy "A&B" complete in all respects.
Providing and fixing of Standard Metal Delineatoras per IRC 79:2019 consisting of retro reflective area in white color using full cube corner micro prismatic non-metallic retro reflective sheeting on each side conforming with IRC 67 2012 and meeting the coefficient of retro reflection values as per ASTM D4956 Type XI table specification. The delineator shall be painted with only black color powder coat of minimum 40 microns thickness, on top of which retro reflective sheeting only in white colour shall be pasted on both sides. The structure shall have height not less than 800 mm above the ground, width not less than 100 mm and shall extend not more than 300mm below the ground while being installed. The delineator shall have grooves across the length to make the reflective sheets vandal-proof. The delineator is meant for application on gaps in median, traffic islands, dangerous bends, roundabouts, narrow bridges etc. or as desired by site engineer. (Csr 2020 item 24.66)
Pile Integrity test (3 Test on each pile)
Acceptance Load Test on bridge as per IRC: SP-51-2015 /Provision of Span load test
Approaches & Diversion Works
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 mtr. Transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with lead upto 5 kms as per Technical Specification clause 301.5
Providing and laying brick on end edging in full brick width and half brick deep including excavation, refilling and disposal of surplus earth, complete in all respects as per PWD specifications. [CSR item no 24.16]
Construction of granular sub base by providing well graded material, spreading in uniform layers on prepared surface, mixing by mix in place method at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical specification clause 401
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening type-A/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening type-B to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.
Providing and applying primer coat with bitumen emulsion (SS-1) Packed on prepared surface of granular base including cleaning of road surface and spraying primer at the rate 0.85 kg/sqm using mechanical means as per Technical specification clause 502
Providing and applying tack coat with Bitumen VG-10 using tar boiler / pressure distributor at the rate of 0.275 kg. per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical specification clause 503 ( for BM)
Providing, laying and rolling of open graded premix carpet of 20mm thickness composed of 13.2mm to 5.6mm aggregates using penetration grade bitumen (VG-30) to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, transported to site, laying and rolling with a three wheel 80-100 KN static roller capacity, finished to required level and grades to be followed by seal coat of Type ‘B as per Technical specification clause 508.
Providing and laying seal coat using bitumen VG-10 for sealing the voids in bituminous surface laid to the specified level, grade and cross fall using Type ‘B’ as per technical specification clause 510.
Provision for road signage boards as per NRIDA Guidelines (First Revision-2019) and IRC:67 & other road furniture
Retro-reflectorised Traffic Signs 900x900x900mm triangular
Providing and fixing of retro-reflectorised (Class A/Class B) cautionary, mandatory and informatory sign as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over ACP Sheet 3.00 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
Direction and Place Identification signs with size 900x600mm
Providing and erecting direction and place identification retro-reflectorised (Class A/Class B) Sign as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over over ACP Sheet 3.00 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Direction and Place Identification signs with size 1200x900mm
Providing and erecting direction and place identification retro-reflectorised (Class A/Class B) sign as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over over ACP Sheet 4 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Providing and fixing of typical PMGSY informatory sign board with Logo
Providing and fixing of typical PMGSY informatory sign board with Logo as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 and drawing. The ACP Plates of 3 mm thick, top and middle plate duly ribbted with MS flat iron 25mm x 5m size on back on edges. The lower ACP plate 4 mm will be ribbted with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be ribbted to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. with Retro-reflectorised Tape (Class A/Class B) in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Providing and fixing of Standard PMGSY Logo Sign Board Double Sided
Providing and fixing of typical PMGSY Logo as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 and drawing. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. with Retro-reflectorised Tape(Class A/Class B) in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Providing and Fixing Citizen Informatory Board of PMGSY Project
Providing and fixing of typical PMGSY Citizen informatory sign board as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 and drawing. Two ACP Plates of 4 mm thick duly ribbted with MS angle iron frame of 25mm x 25mm x 3mm. The angle iron frame will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 600mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. with Retro-reflectorised Tape (Class A/Class B) in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.
Providing and layng centre line 10 /15 mm wide with thermoplastic paint
Diversion Works
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 5000 m as per Technical Specification Clause 301.5
Laying brick soling layer on prepared sub-grade with brick on end edging according to lines, graded and cross-section shown on the drawing filling joints with sand and earth, spreading 25 mm thick layer of earth over brick soling, watering and rolliing the same with three wheel road roller 80-100 kN as per Technical Specification Clause 412
Credit of Bricks
Credit of Brick bats
Hume pipes 1000mm dia
Dismantling of existing structures
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres clause 202 (Brick Work)
RCC Work (Dismantling)
Credit of material
Bricks 20% of brick work
Brick bats 40% of brick work
Steel Recovery
Routine Maintenance after completion of construction worksb as per periodicity to Routine Maintenance mentioned in the contract data.
AMC for 1st Year (Fixed Rate =52637, bidder(s)/vendor(s) need not to quote for this)
AMC for 2ndYear (Fixed Rate =63052, bidder(s)/vendor(s) need not to quote for this)
AMC for 3rd Year (Fixed Rate =88640, bidder(s)/vendor(s) need not to quote for this)
AMC for 4th Year (Fixed Rate =104113, bidder(s)/vendor(s) need not to quote for this)
AMC for 5th Year (Fixed Rate =119585, bidder(s)/vendor(s) need not to quote for this)
SEEMAX AGGREGATE AND CONCRETE
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.50 MB
BOQ_202699.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .