Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder. | |
| 2 | L2₹22.2 L+₹2.3 L (11.3%)Rejected-Finance | L2 | Rejected-Finance Not Lowest. | |
| 3 | L3₹22.7 L+₹2.8 L (13.9%)Rejected-Finance | L3 | Rejected-Finance Not Lowest. | |
| 4 | L4₹22.8 L+₹2.8 L (14.3%)Rejected-Finance | L4 | Rejected-Finance Not Lowest. | |
| 5 | L5₹23.3 L+₹3.3 L (16.7%)Rejected-Finance | L5 | Rejected-Finance Not Lowest. |
Tender Value
Refer Docs
EMD Value
₹38,900
Closing Date
9 Sept 2020, 6:00 pmClosed
GE Kamptee
Military Engineer Services Garrison Engineer Cantt Area Kamptee 441001
SPECIAL REPAIRS TO BLDG NO T-01A, T-362, T-40 AND SURGERY-I AND II OF BLDG NO T-294 AT MH KAMPTEE.
2020_MES_370694_1
8192/E8
Open Tender
Civil Works
Item Rate
180 days
Kamptee
Class E Cat a i
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹38,900
Yes
16 Sept 2020
20 Aug 2020
11 Sept 2020
21 Aug 2020
9 Sept 2020
4 Sept 2020
21 Aug 2020 - 3 Sept 2020
Amount
Dismantling of asbestos cement (Corrugated, semi corrugated etc.) of any thickness including ridges, hips, valleys as in roof covering complete all as specified and directed.
Dismantling of timber fillets, unframed under 40 Sq cm in section complete all as specified and directed.
S&F mild steel work such as roof trusses (framed), trussed purlins and heavy bracket framing (Beam, Tee, angle, Channel or flat section) including distance pieces, cleat etc complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and directed.
M&L for preparation of new steel surfaces of any description not otherwise described, exc 10 cm width or girth & applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for 0.50 mm thick prepainted galvalume aluminium zinc coating G.I. based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering, fixed with and including J/L hooks or self tapping screw all as per manufacturer's instructions complete all as specified and directed.
M&L for 0.50mm thick prepainted galvalume aluminium zinc coating G.I. based plain steel sheet of any colour having tensile strength of 550 Mpa as in ridges/valley, fixed with and including J/L hooks or self tapping screw all as per manufacturer's instructions complete all as specified and directed.
M&L for 6mm thick asbestos cement corrugated sheet, in roofs, wall etc and fixed with ‘L’ or 'J' hooks or cranked bolts or self taping screws with washers complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets of any thickness and wall paneling including cover fillets complete all as specified and directed.
M&L for GI powder coated snap grid framework for false ceiling comprising of the following section for making partition of 600x600 mm size fixed to wall with rawl plug and screw and hanged to roof with 4mm dia GI suspended wire of suitable length and butterfly clip of size of main Tee shall be 32mm x 24mm x 0.30mm, cross tee shall be 28mm x 24mm x 0.30mm thick and wall angle shall be 24mm x 24mm x 0.30mm thick including 4mm thick Non Asbestos, fibre cement building board of size 595x595mm size complete all as specified and directed.
S&F in repairs 4mm thick non asbestos cement plain building boards, fixed to timber framework with screws in ceiling complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed.
M&L for brick work with fly ash bricks old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and directed.
All as per item No 13 above but half brick thick wall in CM 1:4 complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc including removal of debris, complete all as specified and as directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6, finished even and fair without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 and finished even and fair including WPC as per manufacturer's instructions complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
S&F wire netting of galvanised steel wire 0.71mm dia and size of mesh is 12mm fixed in properly with suitable nails for repair of cracks at various locations in wall, beam, chajja, facia, slab, lintel etc including taking down plaster of cracked portion and making good the area by 10mm thick rendering in CM 1:3 complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in platforms etc complete all as specified and directed.
S&F pre-polished granite 18-20mm thick fixed on platform/shelves over 20mm thick screed bed in cement mortar 1:4 including necessary moulding etc complete all as specified and directed.
M&L for machine cut cudappah stone slab 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and directed.
M&L for machine cut kota stone slab flooring 18-20mm thick over cement screed base of 20mm thick in CM 1:4 laid and jointed wih grey cement slurry mixed with pigments to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed bed 10mm thick in CM 1:4 and jointed complete all as specified and directed.
Taking down door / window frame with shutter (without taking of shutter from the frame) area not exc 1.5 sqm complete all as specified and directed.
Taking down door / window frame with shutter (without taking of shutter from the frame) area exc 1.50 sqm but not exc 4 sqm complete all as specified and directed.
Taking down shutters only of any description area exc 1.00 sqm but not exc 2.00 sqm complete all as specified and directed.
M&L for MS Framed work of Fe-290 (Gde E-165) as in doors or gates of angle or other section with gusset plates, rails, braces, MS Plates etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging; also fastening and fixing complete all as specified and directed.
S&F second class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F 30mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 30mm thick 2nd class hard wood factory made glazed and skeleton shutters, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers for windows, ventilators etc, as specified in SSR part-I, Sec-08, Clause 8.24(b), complete all as specified and as directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, and fixing in opening as per specification complete all as specified and directed.
S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 4mm thick moulded laminated PVC Sheet on the front face & 4mm plain colour PVC sheet on back face, with wood free EPS & fixing in frame at site as per specification & drawing complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding and rubbish of the premises complete all as specified and directed.
M&L for coloured glazed ceramic tiles 300x450x6 to 7mm thick, in floors etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles including rendering 10mm thick in CM 1:4 complete all as specified and directed.
M&L for coloured non skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15mm thick screed bed of cement mortar (1:6) etc complete all as specified and as directed.
M&L for scratch free light shade vitrified ceramic tiles 10mm thick (square/ rectangular), polished, area of each tiles not exceeding 0.36 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and as directed.
Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15cm thickness, (Below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
M&L for PCC type D2 1:4:8 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for 75mm thick PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) as in flooring finished cement concrete surface even and smooth using extra cement complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) as in flooring finished cement concrete surface even and smooth using extra cement complete all as specified and directed.
M&L for 75mm thick cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in plinth protection finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping including weathering, throating and necessary formwork complete all as specified and directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape as required, including cranking, bending and binding with mild steel (annealed) wire not less than 0.90mm dia complete all as specified and directed.
M&L for mild steel TMT bars 8mm dia and over, cut to length, bent to shape as required, including cranking, bending and binding with mild steel (annealed) wire not less than 0.90mm dia complete all as specified and directed.
M&L for mild steel TMT bars 8 to 10mm dia as in stirrups, spacers and binders complete all as specified and directed.
M&L for form work to sides of concrete in foundations, footing base, base of columns, side and soffits of plinth beam and similar work complete all as specified and directed.
M&L for providing RCC 1:1 1/2:3 type A-1 (nominal mix) as in footing, foundation, beams, plinth beams, base for columns and mass concrete etc complete all as specified and directed.
M&L for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, and similar work complete all as specified and directed.
M&L for providing RCC 1:1 1/2:3 type A-1 (nominal mix) (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span concrete etc complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20cm wide complete all as specified and directed.
M&L for providing RCC 1:1 1/2:3 type A-1 (nominal mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likes complete all as specified and directed.
M&L for precast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, mangers, shelves and similar articles with plain faces and set in CM 1:6 complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of oil bound distemper over 3mm thick wall care putty complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of cement base paint over a coat of primer on wall etc complete all as specified and directed.
M&L for preparation of old decorative surface of walls by brooming down and applying two coats of white wash including filling cracks and holes etc complete all as specified and directed.
M&L for prepartion of new plastered surfaces and applying two coats of oil bound distemper over 3mm wall care putty complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer on wall etc complete all as specified and directed.
S&F in repairs 1000 ltrs capacity rotational moulded multi layer polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including connections complete all as specified and directed.
S&F ball brass valve, high pressure with polythene float and fly nut complete screwed for iron pipe of size 20mm dia complete all as specified and directed.
S&F GI tubing 15mm bore, medium grade with all fittings and fixed to wall including taking up or down steel tubing and connection complete all as specified and directed.
All as per item 67 above but 20mm bore complete all as specified and directed.
S&F in repairs wash hand basin (flat back or angle back) of size 550 x 400mm, white including waste pipe, chain and plug, porcelain stopper including for & pinning in ends of brackets including S&F waste pipe complete all as specified and directed.
S&F PVC connection 15mm size, 450mm long with PTMT nuts both side complete all as specified and directed.
S&F waste fittings, brass chromium plated for glazed ware sink, basins, etc with long screwed shanks and fly-nuts, flanged end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F in repair sinks with drainage board made of 1mm thick stainless steel, for kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm, bowl size 410mm x 330mm x160mm including waste pipe of 32mm dia complete all as specified and directed.
S&F in repairs 15mm dia pillar cock, fancy typre, cast copper alloy, chromium plated complete all as specified and directed.
S&F in repairs stop cock, fancy type, chromium plated, screwed down, high presure with crutch or butterfly handle screwed both ends for iron pipe of 15mm bore complete all as specified and directed.
S&F in repairs 15mm bore bib taps, fancy type, chromium plated, with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
Taking down point wiring with aluminium conductor cable of light point, fan & socket, light and power complete including light fittings any type, switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fittings, regulator etc and makinggood to the disturbed surfaces of walls / floor etc to match with existing surfaces including white washing / colour washing / distemper to match with existing wall / floor / ceiling finishes complete all as specified and directed.
Taking down sheet metal enclosure, MCB, DB, main switch etc and making good to disturbed surfaces to match with existing surfaces complete all as specified and directed.
Taking down sub main wiring of any size/capacity and making good to disturbed surfaces to match with the existing surfaces complete all as specified and directed.
M&L for point wiring 1100 volt grade single core FRLSH PVC insulated & unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marking medium grade concealed or on surface of wall / ceilling including FRLSH PVC insulated unsheathed earth wire with copper conductor of size 1.50 sqmm pressed steel terminal modular boxes sunk on wall for mounting of switches switch sockets fan regulator etc including modular white cover plate suitable for mounting modular switches, sockets, fan regulator etc complete all as specified and making good to distrubed surfaces for one light point controlled by one, one way switch. Note: Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, cieling roses and holders shall be connected to common earth dolly.
All as per item No 79 above but one ceiling /exhaust/ wall mounted fan point controlled by one switch and regulator complete all as specified and directed.
All as per item No 79 above but one 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
All as per item No 79 above but one 3 pin 5 amp socket out point on independent board complete all as specified and directed.
All as per item No 79 above but one bell/buzzer point controlled by one bell push complete all as specified and directed.
All as per item No 79 above but wiring with 4.0 sqmm multi stranded cable and earth wire with copper conductor of size 4.0 sqmm for 15 amps power point complete all as specified and directed.
All as per item No 79 above but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point complete all as specified and directed.
M&L for sub main wiring with 1100 volt grade two single core FRLSH PVC insulated unsheathed stranded copper conductor cable 2x6 sqmm with and inculding 1x6 sqmm copper conductor earth continuity wire drawing in, concealed in wall and including electrical grade non metallic rigid PVC conduit not less than 20mm dia, medium grade conealed in wall / ceiling as per site rquirement complete all as specified and directed. Note:- Accessories for point/sub main wiring like PVC junction box, bend, tee, elbow shall be of same make.
All as per item No 86 above but 2x4.0 sqmm with and including 1x4.0 sqmm copper conductor complete all as specified and directed.
All as per item No 86 above but 2x2.5 sqmm with and including 1x2.5 sqmm copper conductor complete all as specified and directed.
S&F switch, modular type, single pole, one way, 6 amp, 1 module, 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F switch, modular type, single pole, one way, 16 amp, 1 module, 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F socket, modular type, single pole, one way, 6/16 amp, 2/3 pin, 3 module, 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F socket, modular type, single pole, one way, 6 amp, 3 pin combined, 2 module, 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F modular type bell push 6 amp, 1 module, 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F modular fan step regulator, 120 watt, 2 module, 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F ceiling rose, surface type, 2/3 terminal, 5 amps complete all as specified and directed.
S&F bell ding dong, 230V, AC single phase complete all as specified and directed.
S&F highly durable surface mounted 18/20 watts LED batten/ surface constructed of fire retardant engineering grade extruded plastic and decorative end cap complete with tube rod, driver including 3 core 1.0 sqmm copper conductor cable for connection and accessories complete all as specified and directed. Make:- CG Cat part No LCTLN-20-CDL / Bajaj cat part No BLTRU 20W NW VIVA / Philips cat part No BN150W LED20S-6500 PSE OD GR.
S&F LED light fitting surface mounted bulk head luminaries 9-12W with minimum 800 lumen, IP 65, auminium housing, surge protection including drivers etc complete with all accessories and including connecting up with twin core twisted flexible cable of suitable size of 230V, 50 Hz complete all as specified and directed. Make:- Philips Cat part No Endura LED 10W, Luker Cat Part No LBKOVSL04, CG Cat part No LBH-10-CDL, Surya Cat part No SLE BLH 10W.
S&F LED batten fitting 2' length including drivers having energy consumption 9-11W, 230V, 50Hz, 6500K, not less than 800 lumen, prewired complete all as specified and directed. Make:- Philips Cat part No Slim line 9W, Luker Cat Part No LT5M09, CG Cat part No LCTLN-10-CDL.
S&F building security light LED 20-25W with lumen output 2000 with driver with rated voltage 240V, 50Hz including mounting GI, made out of 25mm dia light grade pipe 0.8m bent to shape including FI clamps, nut bolts etc complete all as specified and directed. Make:- Philips Cat part No BRP020, Luker Cat part No LST24 WH, CG Cat part No LSTS-25-CDL.
S&F sheet metal enclosure single pole & neutral for 240 volts 4/6 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed.
S&F sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed.
S&F MCB single pole 240 volt, 6 to 40 amps, 10 KA breaking capacity, 'C' series, complete all as specified and directed.
S&F MCB single pole and neutral 240 volt, 6 to 40 amps, 10 KA breaking capacity, 'C' series, complete all as specified and directed.
S&F exhaust fan, single phase, 300mm sweep, 230V, 50Hz, metallic body with bolts, nuts, washers and connected electrically complete all as specified and as directed.
M&L for earthing complete with galvanised steet earth plate electrode 600 x 600 x 6mm thick burried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr below the normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts nuts check nuts & washer of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for:- (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm. (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminium lugs etc all as specified. (e) 15mm nominal bore meduim grade GI protection pipe upto 7.50 metre long for protection of earthing lead. (f) Reguisite quantity of charcoal and common salt. (g) Connection to earthing test point and testing on completion.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.39,299.00]
M/s T.S.JOHAR
M/s B S Jain
Shri Mohan Brother
M/s Jagdish Staioners and General Stores
M/s Rahul Traders
khushal constructions
DEESHA CONSTRUCTIONS
NORTH INDIA PEST CONTROL
DE PRETTY AND CO
Bidder Name
DE PRETTY AND CO
SHUB CONSTRUTION
M/s T.S.JOHAR
DEESHA CONSTRUCTIONS
khushal constructions
M/s B S Jain
M/s Rahul Traders
Shri Mohan Brother
M/s Jagdish Staioners and General Stores
NORTH INDIA PEST CONTROL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .