Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC PATIALA | PATIALA | L1 | Accepted-AOC Lowest Quoted amount. | |
| 2 | L2₹20.7 L+₹75,096 (3.76%)Rejected-Finance 137 2 OLD LAL BAGH NEAR PRIMARY VICTORIA SCHOOL PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance Higher Quoted rates | |
| 3 | L3₹22.6 L+₹2.6 L (13.0%)Rejected-Finance | L3 | Rejected-Finance Highest Quoted rates |
Tender Value
₹20 L
EMD Value
₹20,000
Closing Date
9 Sept 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Incharge Civil
Verka Sector 34 A Chandigarh
Augmentation and Re-strengthening of existing 4 Nos. Foundation (60 KL to 100 KL Milk Silos) of Liquid Milk Plant at Verka Mohali Dairy ( for L and C Societies only).
2024_Coop_125768_1
PSF/Civil/12704-07
Open Tender
Civil Works - Others
Item Wise
60 days
Verka Sector 34 A Chandigarh
Please refer Tender Documents.
4 documents required · 4 mandatory
₹500
₹20,000
3 Jan 2025
19 Aug 2024
10 Sept 2024
19 Aug 2024
9 Sept 2024
19 Aug 2024
Amount
Taking out existing CC interlocking paver blocks from footpath/ central verge /pavement, including removal of rubbish etc., disposal of unserviceable material to the dumping ground,for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry or concrete in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Providing and laying Mech. mixed plain cement concrete 1:4:8 with stone aggregate (1 cement: 4 coarse sand: 8 stone aggregate 40mm gauge) including spreading, laying, ramming and consolidating as per requirements and curing etc. but excluding centering and shuttering, complete in all respects as directed by E-in-C.
Providing and fixing steel shuttering for faces of concrete foundations, footings, strips, pedestals, foundation beam, plinth beams (vertical, or battering) and columns etc, below plinth beam. Complete in all respects as directed by E-in-C.
Providing and fixing steel shuttering and Centering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc when curved complete in all respects as directed by E-in-C.
Providing and laying Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth complete in all respects as directed by E-in-C.
Providing and fixing/placing Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008),for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Re-barring (Chemical Anchor) of 12mm dia bar, hole size 16mm, depth 120mm with 14 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical complete in all respect.
Providing and applying Washed stone grit plaster on exterior walls of height upto 10 M. above ground level in two layers, under layer 12.5mm cement plaster 1:4 (1 cement : 4 coarse sand ) furrowing coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2the under layer with scratching tool, applying cementslurry on the under layer @ 2 as perapproved pattern including scrubbing andwashing, the top layer with brushes and water to expose the stone chippings, complete as per specification and direction of Engineer-in- charge.
Extra for washed stone grit plaster on circular work not exceeding 6m in radius (in two coats).
Providing and laying Mech. mixed plain cement concrete 1:4:8with stone aggregate (1 cement: 4 coarse sand: 8 stone aggregate 40mm gauge) including spreading, laying, ramming and consolidating as per requirements and curing etc. but excluding centering and shuttering, complete in all respects as directed by E-in-C.
ARNOULI CO OP L AND C SOCIETY LTD
THE SANT ATTAR SINGH COOP LABOUR AND CONSTRUCTION SOCIETY LTD AT BADBAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .